Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 83
1.
Magn Reson Med ; 92(2): 469-495, 2024 Aug.
Article En | MEDLINE | ID: mdl-38594906

Accurate assessment of cerebral perfusion is vital for understanding the hemodynamic processes involved in various neurological disorders and guiding clinical decision-making. This guidelines article provides a comprehensive overview of quantitative perfusion imaging of the brain using multi-timepoint arterial spin labeling (ASL), along with recommendations for its acquisition and quantification. A major benefit of acquiring ASL data with multiple label durations and/or post-labeling delays (PLDs) is being able to account for the effect of variable arterial transit time (ATT) on quantitative perfusion values and additionally visualize the spatial pattern of ATT itself, providing valuable clinical insights. Although multi-timepoint data can be acquired in the same scan time as single-PLD data with comparable perfusion measurement precision, its acquisition and postprocessing presents challenges beyond single-PLD ASL, impeding widespread adoption. Building upon the 2015 ASL consensus article, this work highlights the protocol distinctions specific to multi-timepoint ASL and provides robust recommendations for acquiring high-quality data. Additionally, we propose an extended quantification model based on the 2015 consensus model and discuss relevant postprocessing options to enhance the analysis of multi-timepoint ASL data. Furthermore, we review the potential clinical applications where multi-timepoint ASL is expected to offer significant benefits. This article is part of a series published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group, aiming to guide and inspire the advancement and utilization of ASL beyond the scope of the 2015 consensus article.


Brain , Cerebrovascular Circulation , Spin Labels , Humans , Brain/diagnostic imaging , Brain/blood supply , Cerebrovascular Circulation/physiology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Magnetic Resonance Imaging/methods , Perfusion Imaging
2.
Magn Reson Med ; 90(5): 1889-1904, 2023 11.
Article En | MEDLINE | ID: mdl-37382246

PURPOSE: Arterial spin labeling (ASL) acquisitions at multiple post-labeling delays may provide more accurate quantification of cerebral blood flow (CBF), by fitting appropriate kinetic models and simultaneously estimating relevant parameters such as the arterial transit time (ATT) and arterial cerebral blood volume (aCBV). We evaluate the effects of denoising strategies on model fitting and parameter estimation when accounting for the dispersion of the label bolus through the vasculature in cerebrovascular disease. METHODS: We analyzed multi-delay ASL data from 17 cerebral small vessel disease patients (50 ± 9 y) and 13 healthy controls (52 ± 8 y), by fitting an extended kinetic model with or without bolus dispersion. We considered two denoising strategies: removal of structured noise sources by independent component analysis (ICA) of the control-label image timeseries; and averaging the repetitions of the control-label images prior to model fitting. RESULTS: Modeling bolus dispersion improved estimation precision and impacted parameter values, but these effects strongly depended on whether repetitions were averaged before model fitting. In general, repetition averaging improved model fitting but adversely affected parameter values, particularly CBF and aCBV near arterial locations in patients. This suggests that using all repetitions allows better noise estimation at the earlier delays. In contrast, ICA denoising improved model fitting and estimation precision while leaving parameter values unaffected. CONCLUSION: Our results support the use of ICA denoising to improve model fitting to multi-delay ASL and suggest that using all control-label repetitions improves the estimation of macrovascular signal contributions and hence perfusion quantification near arterial locations. This is important when modeling flow dispersion in cerebrovascular pathology.


Brain , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Spin Labels , Brain/diagnostic imaging , Brain/blood supply , Arteries , Cerebrovascular Circulation/physiology , Perfusion Imaging/methods
3.
NMR Biomed ; 36(6): e4734, 2023 06.
Article En | MEDLINE | ID: mdl-35322482

Amide proton transfer (APT) imaging, a variant of chemical exchange saturation transfer MRI, has shown promise in detecting ischemic tissue acidosis following impaired aerobic metabolism in animal models and in human stroke patients due to the sensitivity of the amide proton exchange rate to changes in pH within the physiological range. Recent studies have demonstrated the possibility of using APT-MRI to detect acidosis of the ischemic penumbra, enabling the assessment of stroke severity and risk of progression, monitoring of treatment progress, and prognostication of clinical outcome. This paper reviews current APT imaging methods actively used in ischemic stroke research and explores the clinical aspects of ischemic stroke and future applications for these methods.


Acidosis , Ischemic Stroke , Stroke , Animals , Humans , Protons , Amides , Stroke/diagnostic imaging , Magnetic Resonance Imaging/methods
4.
Magn Reson Med ; 89(4): 1323-1341, 2023 04.
Article En | MEDLINE | ID: mdl-36255158

PURPOSE: Dynamic angiography using arterial spin labeling (ASL) can provide detailed hemodynamic information. However, the long time-resolved readouts require small flip angles to preserve ASL signal for later timepoints, limiting SNR. By using time-encoded ASL to generate temporal information, the readout can be shortened. Here, the SNR improvements from using larger flip angles, made possible by the shorter readout, are quantitatively investigated. METHODS: The SNR of a conventional protocol with nine Look-Locker readouts and a 4 × $$ \times $$ 3 time-encoded protocol with three Look-Locker readouts (giving nine matched timepoints) were compared using simulations and in vivo data. Both protocols were compared using readouts with constant flip angles (CFAs) and variable flip angles (VFAs), where the VFA scheme was designed to produce a consistent ASL signal across readouts. Optimization of the background suppression to minimize physiological noise across readouts was also explored. RESULTS: The time-encoded protocol increased in vivo SNR by 103% and 96% when using CFAs or VFAs, respectively. Use of VFAs improved SNR compared with CFAs by 25% and 21% for the conventional and time-encoded protocols, respectively. The VFA scheme also removed signal discontinuities in the time-encoded data. Preliminary data suggest that optimizing the background suppression could improve in vivo SNR by a further 16%. CONCLUSIONS: Time encoding can be used to generate additional temporal information in ASL angiography. This enables the use of larger flip angles, which can double the SNR compared with a non-time-encoded protocol. The shortened time-encoded readout can also lead to improved background suppression, reducing physiological noise and further improving SNR.


Imaging, Three-Dimensional , Magnetic Resonance Angiography , Magnetic Resonance Angiography/methods , Imaging, Three-Dimensional/methods , Brain , Spin Labels , Cerebrovascular Circulation/physiology , Algorithms
5.
Sci Data ; 9(1): 543, 2022 09 06.
Article En | MEDLINE | ID: mdl-36068231

Arterial spin labeling (ASL) is a non-invasive MRI technique that allows for quantitative measurement of cerebral perfusion. Incomplete or inaccurate reporting of acquisition parameters complicates quantification, analysis, and sharing of ASL data, particularly for studies across multiple sites, platforms, and ASL methods. There is a strong need for standardization of ASL data storage, including acquisition metadata. Recently, ASL-BIDS, the BIDS extension for ASL, was developed and released in BIDS 1.5.0. This manuscript provides an overview of the development and design choices of this first ASL-BIDS extension, which is mainly aimed at clinical ASL applications. Discussed are the structure of the ASL data, focussing on storage order of the ASL time series and implementation of calibration approaches, unit scaling, ASL-related BIDS fields, and storage of the labeling plane information. Additionally, an overview of ASL-BIDS compatible conversion and ASL analysis software and ASL example datasets in BIDS format is provided. We anticipate that large-scale adoption of ASL-BIDS will improve the reproducibility of ASL research.


Brain , Magnetic Resonance Imaging , Neuroimaging , Humans , Brain/diagnostic imaging , Magnetic Resonance Imaging/standards , Neuroimaging/methods , Reproducibility of Results , Spin Labels
6.
Magn Reson Med ; 88(2): 546-574, 2022 08.
Article En | MEDLINE | ID: mdl-35452155

Amide proton transfer-weighted (APTw) MR imaging shows promise as a biomarker of brain tumor status. Currently used APTw MRI pulse sequences and protocols vary substantially among different institutes, and there are no agreed-on standards in the imaging community. Therefore, the results acquired from different research centers are difficult to compare, which hampers uniform clinical application and interpretation. This paper reviews current clinical APTw imaging approaches and provides a rationale for optimized APTw brain tumor imaging at 3 T, including specific recommendations for pulse sequences, acquisition protocols, and data processing methods. We expect that these consensus recommendations will become the first broadly accepted guidelines for APTw imaging of brain tumors on 3 T MRI systems from different vendors. This will allow more medical centers to use the same or comparable APTw MRI techniques for the detection, characterization, and monitoring of brain tumors, enabling multi-center trials in larger patient cohorts and, ultimately, routine clinical use.


Brain Neoplasms , Amides , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/pathology , Consensus , Dimaprit/analogs & derivatives , Humans , Magnetic Resonance Imaging/methods , Protons
7.
Magn Reson Med ; 88(1): 341-356, 2022 07.
Article En | MEDLINE | ID: mdl-35253936

PURPOSE: In chemical exchange saturation transfer imaging, saturation effects between - 2 to - 5 ppm (nuclear Overhauser effects, NOEs) have been shown to exhibit contrast in preclinical stroke models. Our previous work on NOEs in human stroke used an analysis model that combined NOEs and semisolid MT; however their combination might feasibly have reduced sensitivity to changes in NOEs. The aim of this study was to explore the information a 4-pool Bloch-McConnell model provides about the NOE contribution in ischemic stroke, contrasting that with an intentionally approximate 3-pool model. METHODS: MRI data from 12 patients presenting with ischemic stroke were retrospectively analyzed, as well as from six animals induced with an ischemic lesion. Two Bloch-McConnell models (4 pools, and a 3-pool approximation) were compared for their ability to distinguish pathological tissue in acute stroke. The association of NOEs with pH was also explored, using pH phantoms that mimic the intracellular environment of naïve mouse brain. RESULTS: The 4-pool measure of NOEs exhibited a different association with tissue outcome compared to 3-pool approximation in the ischemic core and in tissue that underwent delayed infarction. In the ischemic core, the 4-pool measure was elevated in patient white matter ( 1.20±0.20 ) and in animals ( 1.27±0.20 ). In the naïve brain pH phantoms, significant positive correlation between the NOE and pH was observed. CONCLUSION: Associations of NOEs with tissue pathology were found using the 4-pool metric that were not observed using the 3-pool approximation. The 4-pool model more adequately captured in vivo changes in NOEs and revealed trends depending on tissue pathology in stroke.


Ischemic Stroke , Stroke , Animals , Humans , Ischemia , Magnetic Resonance Imaging/methods , Mice , Protons , Retrospective Studies , Stroke/diagnostic imaging
8.
Clin Cancer Res ; 28(11): 2385-2396, 2022 06 01.
Article En | MEDLINE | ID: mdl-35312755

PURPOSE: Despite optimal local therapy, tumor cell invasion into normal brain parenchyma frequently results in recurrence in patients with solid tumors. The aim of this study was to determine whether microvascular inflammation can be targeted to better delineate the tumor-brain interface through vascular cell adhesion molecule-1 (VCAM-1)-targeted MRI. EXPERIMENTAL DESIGN: Intracerebral xenograft rat models of MDA231Br-GFP (breast cancer) brain metastasis and U87MG (glioblastoma) were used to histologically examine the tumor-brain interface and to test the efficacy of VCAM-1-targeted MRI in detecting this region. Human biopsy samples of the brain metastasis and glioblastoma margins were examined for endothelial VCAM-1 expression. RESULTS: The interface between tumor and surrounding normal brain tissue exhibited elevated endothelial VCAM-1 expression and increased microvessel density. Tumor proliferation and stemness markers were also significantly upregulated at the tumor rim in the brain metastasis model. T2*-weighted MRI, following intravenous administration of VCAM-MPIO, highlighted the tumor-brain interface of both tumor models more extensively than gadolinium-DTPA-enhanced T1-weighted MRI. Sites of VCAM-MPIO binding, evident as hypointense signals on MR images, correlated spatially with endothelial VCAM-1 upregulation and bound VCAM-MPIO beads detected histologically. These findings were further validated in an orthotopic medulloblastoma model. Finally, the tumor-brain interface in human brain metastasis and glioblastoma samples was similarly characterized by microvascular inflammation, extending beyond the region detectable using conventional MRI. CONCLUSIONS: This work illustrates the potential of VCAM-1-targeted MRI for improved delineation of the tumor-brain interface in both primary and secondary brain tumors.


Brain Neoplasms , Glioblastoma , Animals , Brain/diagnostic imaging , Brain/metabolism , Brain Neoplasms/metabolism , Disease Models, Animal , Glioblastoma/diagnostic imaging , Glioblastoma/metabolism , Humans , Inflammation/metabolism , Magnetic Resonance Imaging/methods , Rats , Vascular Cell Adhesion Molecule-1/metabolism
9.
Magn Reson Med ; 87(1): 85-101, 2022 01.
Article En | MEDLINE | ID: mdl-34390279

PURPOSE: In this paper, the ability to quantify cerebral blood flow by arterial spin labeling (ASL) was studied by investigating the separation of the macrovascular and tissue component using a 2-component model. Underlying assumptions of this model, especially the inclusion of dispersion in the analysis, were studied, as well as the temporal resolution of the ASL datasets. METHODS: Four different datasets were acquired: (1) 4D ASL angiography to characterize the macrovascular component and to study dispersion modeling within this component, (2) high temporal resolution ASL data to investigate the separation of the 2 components and the effect of dispersion modelling on this separation, (3) low temporal resolution ASL dataset to study the effect of the temporal resolution on the separation of the 2 components, and (4) low temporal resolution ASL data with vascular crushing. RESULTS: The model that included a gamma dispersion kernel had the best fit to the 4D ASL angiography. For the high temporal resolution ASL dataset, inclusion of the gamma dispersion kernel led to more signal included in the arterial blood volume map, which resulted in decreased cerebral blood flow values. The arterial blood volume and cerebral blood flow maps showed overall higher arterial blood volume values and lower cerebral blood flow values for the high temporal resolution dataset compared to the low temporal resolution dataset. CONCLUSION: Inclusion of a gamma dispersion kernel resulted in better fitting of the model to the data. The separation of the macrovascular and tissue component is affected by the inclusion of a gamma dispersion kernel and the temporal resolution of the ASL dataset.


Cerebrovascular Circulation , Magnetic Resonance Imaging , Arteries/diagnostic imaging , Kinetics , Magnetic Resonance Angiography , Spin Labels
10.
Front Neurol ; 12: 753284, 2021.
Article En | MEDLINE | ID: mdl-34777224

SARS-CoV-2 infection has been shown to damage multiple organs, including the brain. Multiorgan MRI can provide further insight on the repercussions of COVID-19 on organ health but requires a balance between richness and quality of data acquisition and total scan duration. We adapted the UK Biobank brain MRI protocol to produce high-quality images while being suitable as part of a post-COVID-19 multiorgan MRI exam. The analysis pipeline, also adapted from UK Biobank, includes new imaging-derived phenotypes (IDPs) designed to assess the possible effects of COVID-19. A first application of the protocol and pipeline was performed in 51 COVID-19 patients post-hospital discharge and 25 controls participating in the Oxford C-MORE study. The protocol acquires high resolution T1, T2-FLAIR, diffusion weighted images, susceptibility weighted images, and arterial spin labelling data in 17 min. The automated imaging pipeline derives 1,575 IDPs, assessing brain anatomy (including olfactory bulb volume and intensity) and tissue perfusion, hyperintensities, diffusivity, and susceptibility. In the C-MORE data, IDPs related to atrophy, small vessel disease and olfactory bulbs were consistent with clinical radiology reports. Our exploratory analysis tentatively revealed some group differences between recovered COVID-19 patients and controls, across severity groups, but not across anosmia groups. Follow-up imaging in the C-MORE study is currently ongoing, and this protocol is now being used in other large-scale studies. The protocol, pipeline code and data are openly available and will further contribute to the understanding of the medium to long-term effects of COVID-19.

11.
Neuroimage ; 238: 118236, 2021 09.
Article En | MEDLINE | ID: mdl-34091034

The mismatch in the spatial resolution of Arterial Spin Labeling (ASL) MRI perfusion images and the anatomy of functionally distinct tissues in the brain leads to a partial volume effect (PVE), which in turn confounds the estimation of perfusion into a specific tissue of interest such as gray or white matter. This confound occurs because the image voxels contain a mixture of tissues with disparate perfusion properties, leading to estimated perfusion values that reflect primarily the volume proportions of tissues in the voxel rather than the perfusion of any particular tissue of interest within that volume. It is already recognized that PVE influences studies of brain perfusion, and that its effect might be even more evident in studies where changes in perfusion are co-incident with alterations in brain structure, such as studies involving a comparison between an atrophic patient population vs control subjects, or studies comparing subjects over a wide range of ages. However, the application of PVE correction (PVEc) is currently limited and the employed methodologies remain inconsistent. In this article, we outline the influence of PVE in ASL measurements of perfusion, explain the main principles of PVEc, and provide a critique of the current state of the art for the use of such methods. Furthermore, we examine the current use of PVEc in perfusion studies and whether there is evidence to support its wider adoption. We conclude that there is sound theoretical motivation for the use of PVEc alongside conventional, 'uncorrected', images, and encourage such combined reporting. Methods for PVEc are now available within standard neuroimaging toolboxes, which makes our recommendation straightforward to implement. However, there is still more work to be done to establish the value of PVEc as well as the efficacy and robustness of existing PVEc methods.


Algorithms , Alzheimer Disease/diagnostic imaging , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Neuroimaging/methods , Alzheimer Disease/pathology , Alzheimer Disease/physiopathology , Amyloid beta-Peptides/analysis , Aniline Compounds , Brain/pathology , Brain/physiopathology , Carbon Radioisotopes , Cerebral Arteries , Cognitive Dysfunction/diagnostic imaging , Cognitive Dysfunction/pathology , Cognitive Dysfunction/physiopathology , Entorhinal Cortex/diagnostic imaging , Entorhinal Cortex/pathology , Entorhinal Cortex/physiopathology , Hippocampus/diagnostic imaging , Hippocampus/pathology , Hippocampus/physiopathology , Image Processing, Computer-Assisted/methods , Membrane Glycoproteins/analysis , Nerve Tissue Proteins/analysis , Organ Size , Perfusion , Positron-Emission Tomography , Pyridines , Pyrrolidinones , Radiopharmaceuticals , Spin Labels , Synaptic Vesicles/chemistry , Thiazoles
12.
Neurobiol Aging ; 105: 35-47, 2021 09.
Article En | MEDLINE | ID: mdl-34022537

This study examined the associations of body mass index (BMI), waist-to-hip ratio (WHR), waist circumference (WC), and physical activity (PA) with gray matter cerebral blood flow (CBFGM) in older adults. Cross-sectional data was used from the Irish Longitudinal Study on Ageing (n = 495, age 69.0 ±7.4 years, 52.1% female). Whole-brain CBFGM was quantified using arterial spin labeling MRI. Results from multivariable regression analysis revealed that an increase in BMI of 0.43 kg/m2, WHR of 0.01, or WC of 1.3 cm were associated with the same reduction in CBFGM as 1 year of advancing age. Participants overweight by BMI or with high WHR/WC reporting low/moderate PA had up to 3 ml/100g/min lower CBFGM (p ≤ .011); there was no significant reduction for those reporting high PA. Since PA could potentially moderate obesity/CBF associations, this may be a cost-effective and relatively easy way to help mitigate the negative impact of obesity in an older population, such as cerebral hypoperfusion, which is an early mechanism in vascular dementia and Alzheimer's disease.


Aging/physiology , Cerebrovascular Circulation , Exercise/physiology , Obesity/physiopathology , Aged , Alzheimer Disease/etiology , Alzheimer Disease/prevention & control , Body Mass Index , Cross-Sectional Studies , Dementia, Vascular/etiology , Dementia, Vascular/prevention & control , Female , Gray Matter/blood supply , Gray Matter/diagnostic imaging , Humans , Longitudinal Studies , Magnetic Resonance Imaging/methods , Male , Middle Aged , Obesity/complications
13.
Magn Reson Med ; 86(4): 2208-2219, 2021 10.
Article En | MEDLINE | ID: mdl-34009682

PURPOSE: Previously, multi- post-labeling delays (PLD) pseudo-continuous arterial spin labeling (pCASL) protocols have been optimized for the estimation accuracy of the cerebral blood flow (CBF) with/without the arterial transit time (ATT) under a standard kinetic model and a normal ATT range. This study aims to examine the estimation errors of these protocols under the effects of macrovascular contamination, flow dispersion, and prolonged arrival times, all of which might differ substantially in elderly or pathological groups. METHODS: Simulated data for four protocols with varying degrees of arterial blood volume (aBV), flow dispersion, and ATTs were fitted with different kinetic models, both with and without explicit correction for macrovascular signal contamination (MVC), to obtain CBF and ATT estimates. Sensitivity to MVC was defined and calculated when aBV > 0.5%. A previously acquired dataset was retrospectively analyzed to compare with simulation. RESULTS: All protocols showed underestimation of CBF and ATT in the prolonged ATT range. With MVC, the protocol optimized for CBF only (CBFopt) had the lowest sensitivity value to MVC, 33.47% and 60.21% error per 1% aBV in simulation and in vivo, respectively, among multi-PLD protocols. All multi-PLD protocols showed a significant decrease in estimation error when an extended kinetic model was used. Increasing flow dispersion at short ATTs caused increasing CBF and ATT overestimation in all protocols. CONCLUSION: CBFopt was the least sensitive protocol to prolonged ATT and MVC for CBF estimation while maintaining reasonably good performance in estimating ATT. Explicitly including a macrovascular component in the kinetic model was shown to be a feasible approach in controlling for MVC.


Cerebrovascular Circulation , Magnetic Resonance Imaging , Aged , Humans , Reproducibility of Results , Retrospective Studies , Spin Labels
14.
Front Physiol ; 12: 643725, 2021.
Article En | MEDLINE | ID: mdl-33868011

BACKGROUND: It is well-established that what is good for the heart is good for the brain. Vascular factors such as hypertension, diabetes, and high cholesterol, and genetic factors such as the apolipoprotein E4 allele increase the risk of developing both cardiovascular disease and dementia. However, the mechanisms underlying the heart-brain association remain unclear. Recent evidence suggests that impairments in vascular phenotypes and cerebrovascular reactivity (CVR) may play an important role in cognitive decline. The Heart and Brain Study combines state-of-the-art vascular ultrasound, cerebrovascular magnetic resonance imaging (MRI) and cognitive testing in participants of the long-running Whitehall II Imaging cohort to examine these processes together. This paper describes the study protocol, data pre-processing and overarching objectives. METHODS AND DESIGN: The 775 participants of the Whitehall II Imaging cohort, aged 65 years or older in 2019, have received clinical and vascular risk assessments at 5-year-intervals since 1985, as well as a 3T brain MRI scan and neuropsychological tests between 2012 and 2016 (Whitehall II Wave MRI-1). Approximately 25% of this cohort are selected for the Heart and Brain Study, which involves a single testing session at the University of Oxford (Wave MRI-2). Between 2019 and 2023, participants will undergo ultrasound scans of the ascending aorta and common carotid arteries, measures of central and peripheral blood pressure, and 3T MRI scans to measure CVR in response to 5% carbon dioxide in air, vessel-selective cerebral blood flow (CBF), and cerebrovascular lesions. The structural and diffusion MRI scans and neuropsychological battery conducted at Wave MRI-1 will also be repeated. Using this extensive life-course data, the Heart and Brain Study will examine how 30-year trajectories of vascular risk throughout midlife (40-70 years) affect vascular phenotypes, cerebrovascular health, longitudinal brain atrophy and cognitive decline at older ages. DISCUSSION: The study will generate one of the most comprehensive datasets to examine the longitudinal determinants of the heart-brain association. It will evaluate novel physiological processes in order to describe the optimal window for managing vascular risk in order to delay cognitive decline. Ultimately, the Heart and Brain Study will inform strategies to identify at-risk individuals for targeted interventions to prevent or delay dementia.

15.
Front Oncol ; 11: 648528, 2021.
Article En | MEDLINE | ID: mdl-33869047

PURPOSE: Relative cerebral blood volume (rCBV) is the most widely used parameter derived from DSC perfusion MR imaging for predicting brain tumor aggressiveness. However, accurate rCBV estimation is challenging in enhancing glioma, because of contrast agent extravasation through a disrupted blood-brain barrier (BBB), and even for nonenhancing glioma with an intact BBB, due to an elevated steady-state contrast agent concentration in the vasculature after first passage. In this study a thorough investigation of the effects of two different leakage correction algorithms on rCBV estimation for enhancing and nonenhancing tumors was conducted. METHODS: Two datasets were used retrospectively in this study: 1. A publicly available TCIA dataset (49 patients with 35 enhancing and 14 nonenhancing glioma); 2. A dataset acquired clinically at Erasmus MC (EMC, Rotterdam, NL) (47 patients with 20 enhancing and 27 nonenhancing glial brain lesions). The leakage correction algorithms investigated in this study were: a unidirectional model-based algorithm with flux of contrast agent from the intra- to the extravascular extracellular space (EES); and a bidirectional model-based algorithm additionally including flow from EES to the intravascular space. RESULTS: In enhancing glioma, the estimated average contrast-enhanced tumor rCBV significantly (Bonferroni corrected Wilcoxon Signed Rank Test, p < 0.05) decreased across the patients when applying unidirectional and bidirectional correction: 4.00 ± 2.11 (uncorrected), 3.19 ± 1.65 (unidirectional), and 2.91 ± 1.55 (bidirectional) in TCIA dataset and 2.51 ± 1.3 (uncorrected), 1.72 ± 0.84 (unidirectional), and 1.59 ± 0.9 (bidirectional) in EMC dataset. In nonenhancing glioma, a significant but smaller difference in observed rCBV was found after application of both correction methods used in this study: 1.42 ± 0.60 (uncorrected), 1.28 ± 0.46 (unidirectional), and 1.24 ± 0.37 (bidirectional) in TCIA dataset and 0.91 ± 0.49 (uncorrected), 0.77 ± 0.37 (unidirectional), and 0.67 ± 0.34 (bidirectional) in EMC dataset. CONCLUSION: Both leakage correction algorithms were found to change rCBV estimation with BBB disruption in enhancing glioma, and to a lesser degree in nonenhancing glioma. Stronger effects were found for bidirectional leakage correction than for unidirectional leakage correction.

16.
Neuroimage ; 229: 117741, 2021 04 01.
Article En | MEDLINE | ID: mdl-33454406

OBJECTIVE: To establish normative reference values for total grey matter cerebral blood flow (CBFGM) measured using pseudo-continuous arterial spin labelling (pCASL) MRI in a large cohort of community-dwelling adults aged 54 years and older. BACKGROUND: Quantitative assessment of CBFGM may provide an imaging biomarker for the early detection of those at risk of neurodegenerative diseases, such as Alzheimer's and dementia. However, the use of this method to differentiate normal age-related decline in CBFGM from pathological reduction has been hampered by the lack of reference values for cerebral perfusion. METHODS: The study cohort comprised a subset of wave 3 (2014-2015) participants from The Irish Longitudinal Study on Ageing (TILDA), a large-scale prospective cohort study of individuals aged 50 and over. Of 4309 participants attending for health centre assessment, 578 individuals returned for 3T multi-parametric MRI brain examinations. In total, CBFGM data acquired from 468 subjects using pCASL-MRI were included in this analysis. Normative values were estimated using Generalised Additive Models for Location Shape and Scale (GAMLSS) and are presented as percentiles, means and standard deviations. RESULTS: The mean age of the cohort was 68.2 ± 6.9 years and 51.7% were female. Mean CBFGM for the cohort was 36.5 ± 8.2 ml/100 g/min. CBFGM decreased by 0.2 ml/100 g/min for each year increase in age (95% CI = -0.3, -0.1; p ≤ 0.001) and was 3.1 ml/100 g/min higher in females (95% CI = 1.6, 4.5; p ≤ 0.001). CONCLUSIONS: This study is by far the largest single-site study focused on an elderly community-dwelling cohort to present normative reference values for CBFGM measured at 3T using pCASL-MRI. Significant age- and sex-related differences exist in CBFGM.


Aging/physiology , Brain/diagnostic imaging , Brain/physiology , Cerebrovascular Circulation/physiology , Gray Matter/diagnostic imaging , Gray Matter/physiology , Aged , Aged, 80 and over , Brain/blood supply , Cohort Studies , Cross-Sectional Studies , Data Analysis , Female , Gray Matter/blood supply , Humans , Ireland/epidemiology , Longitudinal Studies , Magnetic Resonance Imaging/trends , Male , Middle Aged , Prospective Studies
17.
Neuroimage ; 223: 117246, 2020 12.
Article En | MEDLINE | ID: mdl-32853814

Arterial Spin Labeling (ASL) is a non-invasive, non-contrast, perfusion imaging technique which is inherently SNR limited. It is, therefore, important to carefully design scan protocols to ensure accurate measurements. Many pseudo-continuous ASL (PCASL) protocol designs have been proposed for measuring cerebral blood flow (CBF), but it has not yet been demonstrated which design offers the most accurate and repeatable CBF measurements. In this study, a wide range of literature PCASL protocols were first optimized for CBF accuracy and then compared using Monte Carlo simulations and in vivo experiments. The protocols included single-delay, sequential and time-encoded multi-timepoint protocols, and several novel protocol designs, which are hybrids of time-encoded and sequential multi-timepoint protocols. It was found that several multi-timepoint protocols produced more confident, accurate, and repeatable CBF estimates than the single-delay protocol, while also generating maps of arterial transit time. Of the literature protocols, the time-encoded protocol with T1-adjusted label durations gave the most confident and accurate CBF estimates in vivo (16% and 40% better than single-delay), while the sequential multi-timepoint protocol was the most repeatable (20% more repeatable than single-delay). One of the novel hybrid protocols, HybridT1-adj, was found to produce the most confident, accurate and repeatable CBF estimates out of all the protocols tested in both simulations and in vivo (24%, 47%, and 28% more confident, accurate, and repeatable than single-delay in vivo). The HybridT1-adj protocol makes use of the best aspects of both time-encoded and sequential multi-timepoint protocols and should be a useful tool for accurately and efficiently measuring CBF.


Brain/blood supply , Brain/diagnostic imaging , Cerebrovascular Circulation , Magnetic Resonance Imaging/methods , Perfusion Imaging/methods , Adult , Female , Humans , Male , Monte Carlo Method , Reproducibility of Results , Spin Labels , Young Adult
18.
Neuroimage ; 219: 117031, 2020 10 01.
Article En | MEDLINE | ID: mdl-32526385

Arterial spin labeling (ASL) has undergone significant development since its inception, with a focus on improving standardization and reproducibility of its acquisition and quantification. In a community-wide effort towards robust and reproducible clinical ASL image processing, we developed the software package ExploreASL, allowing standardized analyses across centers and scanners. The procedures used in ExploreASL capitalize on published image processing advancements and address the challenges of multi-center datasets with scanner-specific processing and artifact reduction to limit patient exclusion. ExploreASL is self-contained, written in MATLAB and based on Statistical Parameter Mapping (SPM) and runs on multiple operating systems. To facilitate collaboration and data-exchange, the toolbox follows several standards and recommendations for data structure, provenance, and best analysis practice. ExploreASL was iteratively refined and tested in the analysis of >10,000 ASL scans using different pulse-sequences in a variety of clinical populations, resulting in four processing modules: Import, Structural, ASL, and Population that perform tasks, respectively, for data curation, structural and ASL image processing and quality control, and finally preparing the results for statistical analyses on both single-subject and group level. We illustrate ExploreASL processing results from three cohorts: perinatally HIV-infected children, healthy adults, and elderly at risk for neurodegenerative disease. We show the reproducibility for each cohort when processed at different centers with different operating systems and MATLAB versions, and its effects on the quantification of gray matter cerebral blood flow. ExploreASL facilitates the standardization of image processing and quality control, allowing the pooling of cohorts which may increase statistical power and discover between-group perfusion differences. Ultimately, this workflow may advance ASL for wider adoption in clinical studies, trials, and practice.


Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Algorithms , Cerebrovascular Circulation/physiology , Humans , Reproducibility of Results , Signal-To-Noise Ratio , Software , Spin Labels
19.
Eur J Radiol ; 126: 108934, 2020 May.
Article En | MEDLINE | ID: mdl-32217426

PURPOSE: To use a novel segmentation methodology based on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to define tumour subregions of liver metastases from colorectal cancer (CRC), to compare these with histology, and to use these to compare extracted pharmacokinetic (PK) parameters between tumour subregions. MATERIALS AND METHODS: This ethically-approved prospective study recruited patients with CRC and ≥1 hepatic metastases scheduled for hepatic resection. Patients underwent DCE-MRI pre-metastasectomy. Histological sections of resection specimens were spatially matched to DCE-MRI acquisitions and used to define histological subregions of viable and non-viable tumour. A semi-automated voxel-wise image segmentation algorithm based on the DCE-MRI contrast-uptake curves was used to define imaging subregions of viable and non-viable tumour. Overlap of histologically-defined and imaging subregions was compared using the Dice similarity coefficient (DSC). DCE-MRI PK parameters were compared for the whole tumour and histology-defined and imaging-derived subregions. RESULTS: Fourteen patients were included in the analysis. Direct histological comparison with imaging was possible in nine patients. Mean DSC for viable tumour subregions defined by imaging and histology was 0.738 (range 0.540-0.930). There were significant differences between Ktrans and kep for viable and non-viable subregions (p < 0.001) and between whole lesions and viable subregions (p < 0.001). CONCLUSION: We demonstrate good concordance of viable tumour segmentation based on pre-operative DCE-MRI with a post-operative histological gold-standard. This can be used to extract viable tumour-specific values from quantitative image analysis, and could improve treatment response assessment in clinical practice.


Colorectal Neoplasms/pathology , Contrast Media/pharmacokinetics , Image Enhancement/methods , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Magnetic Resonance Imaging/methods , Algorithms , Cluster Analysis , Humans , Liver/diagnostic imaging , Liver/metabolism , Liver Neoplasms/metabolism , Prospective Studies
20.
Magn Reson Med ; 84(3): 1359-1375, 2020 09.
Article En | MEDLINE | ID: mdl-32072677

PURPOSE: Chemical exchange saturation transfer (CEST) is an MRI technique sensitive to the presence of low-concentration solute protons exchanging with water. However, magnetization transfer (MT) effects also arise when large semisolid molecules interact with water, which biases CEST parameter estimates if quantitative models do not account for macromolecular effects. This study establishes under what conditions this bias is significant and demonstrates how using an appropriate model provides more accurate quantitative CEST measurements. METHODS: CEST and MT data were acquired in phantoms containing bovine serum albumin and agarose. Several quantitative CEST and MT models were used with the phantom data to demonstrate how underfitting can influence estimates of the CEST effect. CEST and MT data were acquired in healthy volunteers, and a two-pool model was fit in vivo and in vitro, whereas removing increasing amounts of CEST data to show biases in the CEST analysis also corrupts MT parameter estimates. RESULTS: When all significant CEST/MT effects were included, the derived parameter estimates for each CEST/MT pool significantly correlated (P < .05) with bovine serum albumin/agarose concentration; minimal or negative correlations were found with underfitted data. Additionally, a bootstrap analysis demonstrated that significant biases occur in MT parameter estimates (P < .001) when unmodeled CEST data are included in the analysis. CONCLUSIONS: These results indicate that current practices of simultaneously fitting both CEST and MT effects in model-based analyses can lead to significant bias in all parameter estimates unless a sufficiently detailed model is utilized. Therefore, care must be taken when quantifying CEST and MT effects in vivo by properly modeling data to minimize these biases.


Magnetic Resonance Imaging , Protons , Bias , Humans , Phantoms, Imaging
...