1.
Heliyon ; 10(4): e26001, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38404873

RESUMEN

Mass reduction of mechanical systems is a recurrent objective in engineering, which is often reached by removing material from its mechanical parts. However, this material removal leads to a decrease of mechanical performances for the parts, which must be minimized and controlled to avoid a potential system failure. To find a middle-ground between material removing and mechanical performances), material must be kept only in areas where it is necessary, for example using stress-driven material removal methods. These methods use the stress field to define the local material removal based on two local parameters: the local volume fraction vf and the structural anisotropy orientation ß. These methods may be based on different types of cellular structure patterns: lattice-based or bio-inspired. The long-term objective of this study is to improve the performance of stress-driven methods by using the most efficient pattern. For this purpose, this study investigates the influence of vf and ß on the mechanical stiffness of three planar cellular structures called Periodic Stress-Driven Material Removal (PSDMR) structures. The first, taken from the literature, is bio-inspired from bone and based on a square pattern. The second, developed in this study, is also bio-inspired from bone but based on a rectangular pattern. The third is a strut-based lattice pattern well documented in the literature for its isotropic behavior. These three patterns are compared in this study in terms of relative longitudinal stiffness, obtained through linear elastic compressive tests by finite element analysis. It is highlighted that each PSDMR pattern has a specific domain in which it performs better than the two others. In future works, these domains could be used in stress-driven material removal methods to select the most adequate pattern or a mix of them to improve the performances of parts.

2.
Sci Rep ; 10(1): 5277, 2020 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-32210280

RESUMEN

Arthroplasty is a surgical procedure to restore the function of the joint of patient suffering from knee osteoarthritis. However, postoperative functional deficits are reported even after a rehabilitation program. In order to determine the origin of functional deficits of patient suffering from knee osteoarthritis and total knee arthroplasty, we developed a rodent model including a chemically-induced-osteoarthritis and designed a knee prosthesis (Ti6Al4V/PEEK) biomechanically and anatomically adapted to rat knee joint. Dynamic Weight-Bearing, gait kinematics, H-reflex from vastus medialis muscle and activities from metabosensitive III and IV afferent fibers in femoral nerve were assessed at 1 and 3 months post-surgery. Results indicate that knee osteoarthritis altered considerably the responses of afferent fibers to their known activators (i.e., lactic acid and potassium chloride) and consequently their ability to modulate the spinal sensorimotor loop, although, paradoxically, motor deficits seemed relatively light. On the contrary, results indicate that, after the total knee arthroplasty, the afferent responses and the sensorimotor function were slightly altered but that motor deficits were more severe. We conclude that neural changes attested by the recovery of the metabosensitive afferent activity and the sensorimotor loop were induced when a total knee replacement was performed and that these changes may disrupt or delay the locomotor recovery.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Cetonas , Prótesis de la Rodilla , Osteoartritis de la Rodilla/cirugía , Polietilenglicoles , Titanio , Vías Aferentes/fisiología , Aleaciones , Animales , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Benzofenonas , Modelos Animales de Enfermedad , Nervio Femoral/lesiones , Nervio Femoral/fisiopatología , Marcha , Trastornos Neurológicos de la Marcha/etiología , Trastornos Neurológicos de la Marcha/fisiopatología , Reflejo H , Ácido Yodoacético/toxicidad , Masculino , Músculo Esquelético/fisiopatología , Osteoartritis de la Rodilla/inducido químicamente , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/fisiopatología , Polímeros , Complicaciones Posoperatorias/etiología , Distribución Aleatoria , Ratas , Recuperación de la Función , Soporte de Peso
3.
J Biomed Mater Res B Appl Biomater ; 106(3): 1156-1164, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28556590

RESUMEN

Despite the worldwide high prevalence of total joint arthroplasty (TJA), life expectancy of prosthesis remains limited by mechanical and chemical constraint which promote wear debris production, surrounding tissues damage and finally prosthesis loosening. Such results could be amplified by neuro-myoelectrostimulation (NMES; widely used to reduce neuromuscular deficits observed following TJA surgery). It was previously described in an in vivo experiment that interactions between NMES and Ti6Al4V implant are deleterious for both implant and surrounding muscles. The purpose of the present study was to compare the biocompatibility of four common orthopedic biomaterials, two metallic (Ti6Al4V, CrCo) and two nonmetallic (PEEK, Al2 O3 ) alloys, fixed on rat tibial crest in which the surrounding muscles were electrostimulated. Muscle cell death rate was not found significantly increased, with or without electrical stimulation for nonmetallic implants. Contrary to Ti6Al4V alloy, the CrCo implant did not induce destruction of the surrounding muscle. However, cell viability decreased for both metallic alloys when NMES was applied but within a greater significant extent for Ti6Al4V implant. Otherwise, when NMES was applied, implant-to-bone adhesion significantly decreased for Ti6Al4V while no significant difference was found for PEEK, Al2 O3 , and CrCo. Statistical analyses reveal also a lesser adhesion strength for Ti6Al4V compared with CrCo when NMES was applied. Selecting the most suitable material in term of biocompatibility remains a major concern and non-metallic materials seems to be more appropriated in regard to electrical currents used for post TJA care. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1156-1164, 2018.


Asunto(s)
Materiales Biocompatibles , Estimulación Eléctrica , Ensayo de Materiales , Adhesividad , Aleaciones , Óxido de Aluminio/química , Animales , Artroplastia de Reemplazo , Benzofenonas , Huesos/patología , Supervivencia Celular , Cetonas/química , Masculino , Fibras Musculares Esqueléticas/patología , Músculo Esquelético/fisiología , Polietilenglicoles/química , Polímeros , Diseño de Prótesis , Ratas , Ratas Sprague-Dawley , Titanio/química
4.
J Biomed Mater Res B Appl Biomater ; 106(1): 104-111, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27875027

RESUMEN

New fusionless devices are being developed to get over the limits of actual spinal surgical treatment, based on arthrodesis. However, due to their recentness, no standards exist to test and validate those devices, especially concerning the wear. A new tribological first approach to the definition of an in vitro wear protocol to study wear of flexible and sliding spinal devices is presented in this article, and was applied to a new concept. A simplified synthetic spine portion (polyethylene) was developed to reproduce a simple supra-physiological spinal flexion (10° between two vertebrae). The device studied with this protocol was tested in wet environment until 1 million cycles (Mc). We obtained an encouraging estimated wear volume of same order of magnitude compared to similar devices. An associated finite element (FE) numerical model has permitted to access contact information and study the effect of misalignment of one screw. First results could point out how to improve the design and suggest that a vertical misalignment of a screw (under or over-screwing) has more impact than a horizontal one. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 104-111, 2018.


Asunto(s)
Implantes Experimentales , Modelos Biológicos , Columna Vertebral , Análisis de Elementos Finitos , Humanos
5.
Int J Mol Sci ; 18(7)2017 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-28696371

RESUMEN

Nowadays, salt consumption appears to be drastically above the recommended level in industrialized countries. The health consequences of this overconsumption are heavy since high-salt intake induces cardiovascular disease, kidney dysfunction, and stroke. Moreover, harmful interaction may also occur with orthopaedic devices because overconsumption of salt reinforces the corrosive aspect of biological tissues and favors bone resorption process. In the present study, we aimed to assess the in vivo effect of three weeks of a high-salt diet, associated (or not) with two weeks of the neuro-myoelectrostimulation (NMES) rehabilitation program on the biocompatibility of four biomaterials used in the manufacture of arthroplasty implants. Thus, two non-metallic (PEEK and Al2O3) and two metallic (Ti6Al4V and CrCo) compounds were implanted in the rat tibial crest, and the implant-to-bone adhesion and cell viability of two surrounded muscles, the Flexor Digitorum (FD) and Tibialis Anterior (TA), were assessed at the end of the experiment. Results indicated lower adhesion strength for the PEEK implant compared to other biomaterials. An effect of NMES and a high-salt diet was only identified for Al2O3 and Ti6Al4V implants, respectively. Moreover, compared to a normal diet, a high-salt diet induced a higher number of dead cells on both muscles for all biomaterials, which was further increased for PEEK, Al2O3, and CrCo materials with NMES application. Finally, except for Ti6Al4V, NMES induced a higher number of dead cells in the directly stimulated muscle (FD) compared to the indirectly stimulated one (TA). This in vivo experiment highlights the potential harmful effect of a high-salt diet for people who have undergone arthroplasty, and a rehabilitation program based on NMES.


Asunto(s)
Materiales Biocompatibles/química , Cloruro de Sodio Dietético/efectos adversos , Aleaciones , Óxido de Aluminio/química , Animales , Benzofenonas , Supervivencia Celular/efectos de los fármacos , Humanos , Cetonas/química , Masculino , Polietilenglicoles/química , Polímeros , Ratas , Ratas Sprague-Dawley , Titanio/química
6.
PLoS One ; 11(1): e0146873, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26761710

RESUMEN

AIM OF THE STUDY: High-salt consumption has been widely described as a risk factor for cardiovascular, renal and bone functions. In the present study, the extent to which high-salt diet could influence Ti6Al4V implant surface characteristic, its adhesion to rat tibial crest, and could modify muscle cell viability of two surrounding muscles, was investigated in vivo. These parameters have also been assessed following a NMES (neuro-myoelectrostimulation) program similar to that currently used in human care following arthroplasty. RESULTS: After a three-week diet, a harmful effect on titanium implant surface and muscle cell viability was noted. This is probably due to salt corrosive effect on metal and then release of toxic substance around biologic tissue. Moreover, if the use of NMES with high-salt diet induced muscles damages, the latter were higher when implant was added. Unexpectedly, higher implant-to-bone adhesion was found for implanted animals receiving salt supplementation. CONCLUSION: Our in vivo study highlights the potential dangerous effect of high-salt diet in arthroplasty based on titanium prosthesis. This effect appears to be more important when high-salt diet is combined with NMES.


Asunto(s)
Músculos/fisiología , Prótesis e Implantes , Cloruro de Sodio Dietético/efectos adversos , Titanio/química , Aleaciones , Animales , Artroplastia , Presión Sanguínea , Supervivencia Celular , Materiales Biocompatibles Revestidos , Dieta , Estimulación Eléctrica , Masculino , Músculos/patología , Oseointegración/fisiología , Implantación de Prótesis , Ratas , Ratas Sprague-Dawley , Factores de Riesgo , Propiedades de Superficie , Tibia/patología
7.
J Biomed Mater Res B Appl Biomater ; 103(8): 1594-601, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25533414

RESUMEN

Electrical currents have deleterious effects on biomedical metallic implants. However, following arthroplasty, neuro-myoelectrostimulation (NMES) is often used in patient rehabilitation. Such a rehabilitation technique could compromise patient recovery through deleterious effects on metallic alloys and biological tissues. The purpose of our study was to assess the effects of NMES on a Ti6Al4V implant placed in a rat tibial crest and the surrounding muscle tissues. This in vivo study allowed to bring to the fore the prosthesis behavior under mechanical and electromagnetic loads induced by NEMS stimulation. After 3 weeks, implant-to-bone adhesion significantly decreased in stimulated animals compared with nonstimulated animals. Surface mapping indicated titanium implant degradation after NMES. Furthermore, NMES alone did not induce muscle damage contrary to that found in implanted animals. The muscle damage rate was significantly higher in implanted and stimulated animals compared with implanted-only animals. It seems obvious that rehabilitation programs using the NMES technique could induce early deterioration of biomaterial employed for surgical implants. Clinicians should reconsider the use of NMES as a rehabilitation technique for patients with titanium prostheses.


Asunto(s)
Sustitutos de Huesos , Ensayo de Materiales , Células Musculares/metabolismo , Músculo Esquelético/metabolismo , Prótesis e Implantes , Tibia/metabolismo , Titanio , Aleaciones , Animales , Células Musculares/patología , Músculo Esquelético/patología , Ratas , Tibia/patología
SELECCIÓN DE REFERENCIAS