Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Am J Cardiol ; 225: 25-34, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38871156

RESUMEN

Shortening the duration of dual-antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) was shown to be effective and safe in patients at high bleeding risk (HBR). We aimed to investigate the effect of 1 versus 3-month DAPT on outcomes after drug-eluting stent in HBR patients with or without chronic kidney disease (CKD). Data from 3 prospective single-arm studies (XIENCE Short DAPT Program) enrolling HBR patients after successful coronary implantation of cobalt-chromium everolimus-eluting stent (XIENCE, Abbott) were analyzed. Subjects were eligible for DAPT discontinuation at 1 or 3 months if free from ischemic events. The primary end point was all-cause death or any myocardial infarction. The key secondary end point was Bleeding Academic Research Consortium Type 2 to 5 bleeding. Outcomes were assessed from 1 to 12 months after PCI. CKD was defined as baseline creatinine clearance <60 ml/min. Of 3,286 patients, 1,432 (43.6%) had CKD. One-month versus 3-month DAPT was associated with a similar 12-month risk of the primary outcome irrespective of CKD status (CKD: 9.5% vs 10.9%, adjusted hazard ratio 0.86, 95% confidence interval 0.60 to 1.22; no-CKD: 6.6% vs 5.6%, adjusted hazard ratio 1.15, 95% confidence interval 0.77 to 1.73; p interaction 0.299). Bleeding Academic Research Consortium 2 to 5 bleeding rates were numerically but not significantly lower with 1-month versus 3-month DAPT in both CKD (9.9% vs 12%) and no-CKD (6.4% vs 9.0%) patients. In conclusion, in HBR patients, 1-month versus 3-month DAPT was associated with a similar risk of ischemic complications and a trend toward fewer bleeding events at 12 months after PCI, irrespective of CKD status.


Asunto(s)
Stents Liberadores de Fármacos , Terapia Antiplaquetaria Doble , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria , Insuficiencia Renal Crónica , Humanos , Masculino , Femenino , Insuficiencia Renal Crónica/complicaciones , Intervención Coronaria Percutánea/métodos , Anciano , Inhibidores de Agregación Plaquetaria/uso terapéutico , Inhibidores de Agregación Plaquetaria/administración & dosificación , Persona de Mediana Edad , Estudios Prospectivos , Terapia Antiplaquetaria Doble/métodos , Hemorragia/epidemiología , Hemorragia/inducido químicamente , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Factores de Tiempo , Clopidogrel/uso terapéutico , Clopidogrel/administración & dosificación , Aspirina/administración & dosificación , Aspirina/uso terapéutico , Infarto del Miocardio/epidemiología , Causas de Muerte/tendencias , Esquema de Medicación , Factores de Riesgo
2.
EuroIntervention ; 20(10): e630-e642, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38776146

RESUMEN

BACKGROUND: A short dual antiplatelet therapy (DAPT) duration has been proposed for patients at high bleeding risk (HBR) undergoing drug-eluting coronary stent (DES) implantation. Whether this strategy is safe and effective after a non-ST-segment elevation acute coronary syndrome (NSTE-ACS) remains uncertain. AIMS: We aimed to compare the impact of 1-month versus 3-month DAPT on clinical outcomes after DES implantation among HBR patients with or without NSTE-ACS. METHODS: This is a prespecified analysis from the XIENCE Short DAPT programme involving three prospective, international, single-arm studies evaluating the safety and efficacy of 1-month (XIENCE 28 USA and Global) or 3-month (XIENCE 90) DAPT among HBR patients after implantation of a cobalt-chromium everolimus-eluting stent. Ischaemic and bleeding outcomes associated with 1- versus 3-month DAPT were assessed according to clinical presentation using propensity score stratification. RESULTS: Of 3,364 HBR patients (1,392 on 1-month DAPT and 1,972 on 3-month DAPT), 1,164 (34.6%) underwent DES implantation for NSTE-ACS. At 12 months, the risk of the primary endpoint of death or myocardial infarction was similar between 1- and 3-month DAPT in patients with (hazard ratio [HR] 1.09, 95% confidence interval [CI]: 0.71-1.65) and without NSTE-ACS (HR 0.88, 95% CI: 0.63-1.23; p-interaction=0.34). The key secondary endpoint of Bleeding Academic Research Consortium (BARC) Type 2-5 bleeding was consistently reduced in both NSTE-ACS (HR 0.57, 95% CI: 0.37-0.88) and stable patients (HR 0.84, 95% CI: 0.61-1.15; p-interaction=0.15) with 1-month DAPT. CONCLUSIONS: Among HBR patients undergoing implantation of an everolimus-eluting stent, 1-month, compared to 3-month DAPT, was associated with similar ischaemic risk and reduced bleeding at 1 year, irrespective of clinical presentation.


Asunto(s)
Síndrome Coronario Agudo , Stents Liberadores de Fármacos , Terapia Antiplaquetaria Doble , Hemorragia , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/instrumentación , Síndrome Coronario Agudo/terapia , Inhibidores de Agregación Plaquetaria/uso terapéutico , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Masculino , Persona de Mediana Edad , Anciano , Femenino , Hemorragia/inducido químicamente , Resultado del Tratamiento , Terapia Antiplaquetaria Doble/métodos , Estudios Prospectivos , Factores de Tiempo , Factores de Riesgo , Infarto del Miocardio sin Elevación del ST/terapia , Infarto del Miocardio sin Elevación del ST/mortalidad
3.
Am J Cardiol ; 214: 94-104, 2024 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-38185438

RESUMEN

This analysis aimed to evaluate the effect of 1- versus 3-month dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) in older patients. Data from 3 prospective, single-arm studies (XIENCE Short DAPT Program), including patients with high bleeding risk successfully treated with an everolimus-eluting stent (XIENCE, Abbott) were analyzed. DAPT was discontinued at 1 or at 3 months in patients free from ischemic events and adherent to DAPT. Patients were stratified according to age (≥75 and <75 years). The primary end point was all-cause death or myocardial infarction (MI). The key secondary end point was Bleeding Academic Research Consortium type 2 to 5 bleeding. The outcomes were assessed from 1 to 12 months after index PCI. Of 3,364 patients, 2,241 (66.6%) were aged ≥75 years. The risk of death or MI was similar with 1- versus 3-month DAPT in patients aged ≥75 (8.5% vs 8.0%, adjusted hazard ratio [HR] 0.95, 95% confidence interval [CI] 0.69 to 1.30) and <75 years (6.9% vs 7.8%, adjusted HR 0.97, 95% CI 0.60 to 1.57, interaction p = 0.478). Bleeding Academic Research Consortium type 2 to 5 bleeding was consistently lower with 1- than with 3-month DAPT in patients aged ≥75 years (7.2% vs 9.4%, adjusted HR 0.66, 95% CI 0.48 to 0.91) and <75 years (9.7% vs 11.9%, adjusted HR 0.86, 95% CI 0.57 to 1.29, interaction p = 0.737). In conclusion, in patients at high bleeding risk who underwent PCI, patients older and younger than 75 years derived a consistent benefit from 1- compared with 3-month DAPT in terms of bleeding reduction, with no increase in all-cause death or MI at 1 year.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Anciano , Inhibidores de Agregación Plaquetaria/uso terapéutico , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Quimioterapia Combinada , Hemorragia/epidemiología , Hemorragia/inducido químicamente , Infarto del Miocardio/epidemiología , Infarto del Miocardio/tratamiento farmacológico , Resultado del Tratamiento
4.
JACC Case Rep ; 22: 101986, 2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37790763

RESUMEN

A 65-year-old obese woman with rheumatic heart disease and restrictive lung disease presented with decompensated heart failure. Evaluation demonstrated severely thickened mitral valve leaflets, severe mitral stenosis, and moderate mitral regurgitation. She underwent successful transfemoral transseptal transcatheter mitral valve replacement with a dedicated valve resulting in improved functional status. (Level of Difficulty: Advanced.).

5.
JACC Cardiovasc Interv ; 16(20): 2498-2510, 2023 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-37804290

RESUMEN

BACKGROUND: The optimal duration of dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) in patients on long-term oral anticoagulation (OAC) therapy is still uncertain. OBJECTIVES: The aim of this analysis was to assess the effects of 1- vs 3-month DAPT in patients with and those without concomitant OAC included in the XIENCE Short DAPT program. METHODS: The XIENCE Short DAPT program enrolled patients with high bleeding risk who underwent successful PCI with a cobalt-chromium everolimus-eluting stent. DAPT was discontinued at 1 or 3 months in patients free from ischemic events and adherent to treatment. The effect of 1- vs 3-month DAPT was compared in patients with and those without OAC using propensity score stratification. The primary endpoint was all-cause death or any myocardial infarction (MI). The key secondary endpoint was Bleeding Academic Research Consortium (BARC) types 2 to 5 bleeding. Outcomes were assessed from 1 to 12 months after index PCI. RESULTS: Among 3,364 event-free patients, 1,462 (43%) were on OAC. Among OAC patients, the risk for death or MI was similar between 1- and 3-month DAPT (7.4% vs 8.8%; adjusted HR: 0.74; 95% CI: 0.49-1.11; P = 0.139), whereas BARC types 2 to 5 bleeding was lower with 1-month DAPT (adjusted HR: 0.71; 95% CI: 0.51-0.99; P = 0.046). These effects were consistent in patients with and those without OAC (P for interaction = NS). CONCLUSIONS: Between 1 and 12 months after PCI, 1-month compared with 3-month DAPT was associated with similar rates of all-cause death or MI and a reduced rate of BARC types 2 to 5 bleeding, irrespective of OAC treatment.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Stents Liberadores de Fármacos/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Quimioterapia Combinada , Anticoagulantes/efectos adversos , Infarto del Miocardio/etiología , Hemorragia/inducido químicamente
6.
J Soc Cardiovasc Angiogr Interv ; 2(2): 100562, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-39129811

RESUMEN

Background: The FlexNav delivery system (DS) features a hydrophilic coating, stability layer, and integrated sheath to facilitate valve deployment in vessel diameters ≥5.0 mm. Methods: Data were pooled from 2 concurrent prospective, multicenter, premarket studies (PORTICO IDE [n = 147] and FlexNav EU CE Mark [n = 46]) to evaluate the safety and efficacy of the FlexNav DS to deliver the Portico valve in the Global FlexNav study. The primary end point was Valve Academic Research Consortium (VARC)-2 major vascular complication rate at 30 days. These outcomes were compared with those of the commercially available valve arm from the PORTICO IDE study. Results: The Global FlexNav study enrolled 193 high- or extreme-risk subjects for sugery. The mean age was 84.8 years, and 59.6% were women, with a mean Society of Thoracic Surgeons score of 5.2%. At 1 year, the rate of all-cause mortality was 5.2%, disabling stroke 2.1%, and mild or less paravalvular leak 99.4%. The mean aortic gradient was maintained at 7.4 ± 4.3 mm Hg through 1 year. At 1 year, 96.8% of subjects were classified as New York Heart Association class I or II. A pacemaker was implanted in 15.4% of subjects at 30 days and 18.4% at 1 year. The results of the Portico valve in the Global FlexNav study are comparable with the results from the commercially available valve arm in the PORTICO IDE study. Conclusion: The FlexNav DS was shown to be safe for the delivery of the Portico valve, which demonstrated sustained treatment benefits at 1 year with low rates of all-cause mortality or disabling stroke, improved heart failure symptoms, and excellent valve performance.

7.
J Soc Cardiovasc Angiogr Interv ; 2(6Part A): 101118, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-39129892

RESUMEN

Background: Long-term outcomes after percutaneous coronary intervention (PCI) for in-stent restenosis (ISR) are poor, yet limited granular procedural data exist evaluating lesion assessment, vessel treatment, and acute procedural outcomes. Methods: The LightLab Initiative was a multicenter, prospective, observational study with contemporaneous procedural data collection during PCI procedures. Data were collected during PCIs performed by 48 interventional cardiologists at 17 US hospitals (2019-2021). Optical coherence tomography (OCT) was performed pre-PCI for lesion assessment and post-PCI for stent optimization, and results were compared between ISR and de novo lesion PCI. Results: In total, 2592 OCT-guided PCIs involving 2944 lesions were included, of which 458 procedures (17.7%) were ISR PCI. Compared with de novo lesion PCI, ISR lesions were more commonly type C (64.8% vs 52.9%) and performed via femoral artery access (46.4% vs 37.7%). Use of OCT changed operator assessment and treatment decisions more frequently in ISR PCI (94.2% vs 85.2%; P = .002). Scoring balloons (21.8% vs 2.5%), cutting balloons (16.4% vs 3.4%), and atherectomy (26.3% vs 9.9%) were used more commonly in ISR PCI (all P < .0001), and ISR PCI procedures were longer (62 vs 51 min). Moreover, the final achieved minimum stent area and percent expansion (4.4 vs 5.1 mm2 and 80% vs 83%, respectively; both P < .0001) were lower in ISR PCI. Conclusions: In this real-world cohort of patients who underwent OCT-guided PCI, ISR procedures were longer and final minimum stent area and percent expansion were lower despite greater use of advanced lesion modification. OCT frequently altered physician decision making, emphasizing its utility in potentially reducing recurrent stent failure in this high-risk population.

8.
Catheter Cardiovasc Interv ; 100 Suppl 1: S14-S24, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36661365

RESUMEN

OBJECTIVES: This study was designed to compare efficiency and quality metrics between percutaneous coronary intervention (PCI) procedures using optical coherence tomography (OCT) guided by a variable workflow versus a standardized workflow in a real-world population. BACKGROUND: The LightLab (LL) Initiative was designed to evaluate the impact of a standardized OCT workflow during PCI to address barriers to adoption. METHODS: The LL Initiative was a multicenter, prospective, observational study. PCI efficiency data were collected from 1/21/19 to 1/8/21 from 45 physicians at 17 US centers. OCT-guided PCIs were compared between baseline phase (variable workflow; N = 383) and the LL workflow utilization phase (N = 447). The LL workflow uses OCT to assess lesion Morphology, Length and Diameter, and then optimize outcomes by correcting for Medial dissection, stent mal-Apposition, and under-eXpansion (MLD MAX). Matching based on propensity scores was used to control for differences between PCIs. RESULTS: After propensity matching, 291 paired procedures were included. Integration of the LL versus variable workflow resulted in no difference in procedure time (51 min vs. 51 min, p = 0.93). There was a reduction in radiation exposure (1124 mGy vs. 1493 mGy, p < 0.0001) and contrast volume (160 cc vs. 172 cc, p < 0.001). The LL workflow decreased the proportion of underexpanded lesions (34% vs. 54%, p < 0.0001) and improved minimum stent expansion (85% vs. 79%, p < 0.0001). Number of noncompliant balloons used was reduced with the LL workflow. (2.0 vs. 1.7, p < 0.01). CONCLUSIONS: These data suggest that standardizing imaging with the LL workflow may overcome barriers to imaging and improve PCI outcomes without prolonging procedures.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Angiografía Coronaria/métodos , Tomografía de Coherencia Óptica/métodos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Flujo de Trabajo , Resultado del Tratamiento , Stents , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología
9.
J Am Coll Cardiol ; 78(21): 2060-2072, 2021 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-34794687

RESUMEN

BACKGROUND: The optimal duration of dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) among patients at high bleeding risk (HBR) is unknown. OBJECTIVES: The purpose of this analysis was to compare 1 vs 3 months of DAPT in HBR patients undergoing drug-eluting stent implantation. METHODS: The XIENCE Short DAPT program comprised 3 prospective, multicenter, single-arm studies of HBR patients treated with a short DAPT course followed by aspirin monotherapy after PCI with a cobalt-chromium everolimus-eluting stent. In this exploratory analysis, patients who received 1-month DAPT (XIENCE 28 USA and 28 Global) were compared with those on 3-month DAPT (XIENCE 90) using propensity score stratification. Ischemic and bleeding outcomes were assessed between 1 and 12 months after index PCI. RESULTS: A total of 3,652 patients were enrolled and 1,392 patients after 1-month DAPT and 1,972 patients after 3-month DAPT were eligible for the analyses. The primary endpoint of all-cause mortality or myocardial infarction was similar between the 2 groups (7.3% vs 7.5%; difference -0.2%; 95% CI: -2.2% to 1.7%; P = 0.41). The key secondary endpoint of BARC (Bleeding Academic Research Consortium) type 2-5 bleeding was lower with 1-month DAPT compared with 3-month DAPT (7.6% vs 10.0%; difference -2.5%; 95% CI: -4.6% to -0.3%; P = 0.012). Major BARC type 3-5 bleeding did not differ at 12 months (3.6% vs 4.7%; difference -1.1%; 95% CI: -2.6% to 0.4%; P = 0.082), but was lower with 1-month DAPT at 90 days (1.0% vs 2.1%; P = 0.015). CONCLUSIONS: Among HBR patients undergoing PCI, 1 month of DAPT, compared with 3 months of DAPT, was associated with similar ischemic outcomes and lower bleeding risk. (XIENCE 90 Study; NCT03218787; XIENCE 28 USA Study; NCT03815175; XIENCE 28 Global Study; NCT03355742).


Asunto(s)
Stents Liberadores de Fármacos , Terapia Antiplaquetaria Doble/métodos , Hemorragia/inducido químicamente , Hemorragia/prevención & control , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Anciano , Anciano de 80 o más Años , Aspirina/administración & dosificación , Aspirina/efectos adversos , Esquema de Medicación , Stents Liberadores de Fármacos/efectos adversos , Terapia Antiplaquetaria Doble/efectos adversos , Femenino , Estudios de Seguimiento , Hemorragia/diagnóstico , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Estudios Prospectivos , Antagonistas del Receptor Purinérgico P2Y/administración & dosificación , Antagonistas del Receptor Purinérgico P2Y/efectos adversos , Factores de Riesgo
10.
JACC Cardiovasc Interv ; 14(17): 1870-1883, 2021 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-34503737

RESUMEN

OBJECTIVES: The aim of this study was to evaluate 2 abbreviated dual-antiplatelet therapy (DAPT) regimens in patients at high bleeding risk (HBR) undergoing percutaneous coronary intervention (PCI). BACKGROUND: Current-generation drug-eluting stents are preferred over bare-metal stents for HBR patients, but their optimal DAPT management remains unknown. METHODS: The XIENCE Short DAPT program included 3 prospective, multicenter, single-arm studies enrolling HBR patients who underwent successful PCI with a cobalt-chromium everolimus-eluting stent. After 1 month (XIENCE 28 USA and XIENCE 28 Global) or 3 months (XIENCE 90) of DAPT, event-free patients discontinued the P2Y12 inhibitor. The postmarketing approval XIENCE V USA study was used as historical control in a propensity score-stratified analysis. RESULTS: A total of 3,652 patients were enrolled. The propensity-adjusted rate of the primary endpoint of all-cause mortality or myocardial infarction was 5.4% among 1,693 patients on 3-month DAPT versus 5.4% in the 12-month DAPT historical control (Pnoninferiority = 0.0063) and 3.5% among 1,392 patients on 1-month DAPT versus 4.3% in the 6-month DAPT historical control (Pnoninferiority = 0.0005). Bleeding Academic Research Consortium (BARC) types 2 to 5 bleeding was not significantly lower with 3- or 1-month DAPT, while BARC types 3 to 5 bleeding was reduced in both experimental groups. The rate of definite or probable stent thrombosis was 0.2% in XIENCE 90 (P < 0.0001 for the performance goal of 1.2%) and 0.3% in XIENCE 28. CONCLUSIONS: Among HBR patients undergoing PCI with cobalt-chromium everolimus-eluting stents, DAPT for 1 or 3 months was noninferior to 6 or 12 months of DAPT for ischemic outcomes and may be associated with less major bleeding and a low incidence of stent thrombosis.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Quimioterapia Combinada , Everolimus/efectos adversos , Hemorragia/inducido químicamente , Humanos , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento
12.
Am Heart J ; 231: 147-156, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33031789

RESUMEN

Dual antiplatelet therapy (DAPT) is key for the prevention of recurrent ischemic events after percutaneous coronary intervention (PCI); however, it increases the risk of bleeding complications. While new generation drug-eluting stents have been shown superior to bare-metal stents after a short DAPT course, the optimal DAPT duration in patients at high bleeding risk (HBR) remains to be determined. TRIAL DESIGN: The XIENCE Short DAPT program consists of three prospective, single-arm studies (XIENCE 90, XIENCE 28 Global and XIENCE 28 USA) investigating 3- or 1-month DAPT durations in HBR patients undergoing PCI with the XIENCE stent. The XIENCE 90 study is being conducted in the US and enrolled 2047 subjects who discontinued DAPT at 3 months if they were free from myocardial infarction (MI), repeat coronary revascularization, stroke, or stent thrombosis. The XIENCE 28 program includes the USA study, enrolling 642 patients in US and Canada, and the Global study, enrolling 963 patients in Europe and Asia. In XIENCE 28, patients were to discontinue DAPT at 1 month post-PCI if event-free. The primary hypothesis for both XIENCE 90 and XIENCE 28 is that a short DAPT regimen will be non-inferior to a conventional DAPT duration with respect to the composite of all-cause death or MI. Patients enrolled in the prospective multicenter post-market XIENCE V USA study will be used as historical control group in a stratified propensity-adjusted analysis. CONCLUSIONS: The XIENCE Short DAPT Program will provide insights into the safety and efficacy of 2 abbreviated DAPT regimens of 3- and 1-month duration in a large cohort of HBR patients undergoing PCI with the XIENCE stent.


Asunto(s)
Síndrome Coronario Agudo/tratamiento farmacológico , Aspirina/administración & dosificación , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Inmunosupresores/administración & dosificación , Infarto del Miocardio/prevención & control , Inhibidores de Agregación Plaquetaria/administración & dosificación , Antagonistas del Receptor Purinérgico P2Y/administración & dosificación , Aspirina/efectos adversos , Canadá , Causas de Muerte , Esquema de Medicación , Stents Liberadores de Fármacos/efectos adversos , Hemorragia/inducido químicamente , Hemorragia/prevención & control , Humanos , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/efectos adversos , Estudios Prospectivos , Antagonistas del Receptor Purinérgico P2Y/efectos adversos , Accidente Cerebrovascular , Trombosis , Estados Unidos
13.
JACC Cardiovasc Interv ; 13(21): 2467-2478, 2020 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-33153563

RESUMEN

OBJECTIVES: The aim of this study was to characterize the safety profile of an intra-annular self-expanding valve with a next-generation low-profile delivery system (DS). BACKGROUND: Key design modifications to the FlexNav DS include the addition of a hydrophilic-coated, integrated sheath and stability layer to facilitate gradual, controlled deployment in vessels with diameter ≥5 mm. METHODS: Patients were pooled from 2 concurrent prospective, multicenter, single-arm studies (FlexNav DS arm of PORTICO IDE [Portico Re-Sheathable Transcatheter Aortic Valve System U.S. IDE Trial] [n = 134] and the FlexNav EU CE Mark Study [n = 46]) for the analysis. The primary endpoint was Valve Academic Research Consortium-2-defined major vascular complications at 30 days. Clinical outcomes and valve performance were assessed through 30 days by an independent clinical events committee and an echocardiography core laboratory, respectively. RESULTS: One hundred forty high-risk and 40 extreme-risk subjects enrolled between October 15, 2018, and December 10, 2019, from 28 sites in the United States, Australia, and Europe who underwent attempted transfemoral Portico valve implantation were included. The mean age was 85.1 ± 5.6 years, 60% were women, the mean Society of Thoracic Surgeons score was 5.3%, and 96.1% presented with ≥1 frailty factor. Technical device success was 96.7%. At 30 days, the rate of major vascular complications was 5.0%, with 4.4% of complications adjudicated as access site-related (3.3% transcatheter aortic valve replacement DS access site-related). Death (0.6%) and disabling stroke (1.1%) were rare. The rate of new permanent pacemaker implantation was 15.4%. Echocardiography revealed a mean gradient of 7.1 ± 3.2 mm Hg, mean valve area of 1.77 ± 0.41 cm2, and a 4.1% rate of moderate paravalvular leak at 30 days. CONCLUSIONS: Portico valve implantation with the FlexNav DS was associated with an excellent safety profile at 30 days.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Australia , Europa (Continente) , Femenino , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
14.
JACC Cardiovasc Interv ; 10(23): 2349-2359, 2017 12 11.
Artículo en Inglés | MEDLINE | ID: mdl-29216997

RESUMEN

Significant progress has been made in the percutaneous coronary intervention technique from the days of balloon angioplasty to modern-day metallic drug-eluting stents (DES). Although metallic stents solve a temporary problem of acute recoil following balloon angioplasty, they leave behind a permanent problem implicated in very late events (in addition to neoatherosclerosis). BRS were developed as a potential solution to this permanent problem, but the promise of these devices has been tempered by clinical trials showing increased risk of safety outcomes, both early and late. This is not too dissimilar to the challenges seen with first-generation DES in which refinement of deployment technique, prolongation of dual antiplatelet therapy, and technical iteration mitigated excess risk of very late stent thrombosis, making DES the treatment of choice for coronary artery disease. This white paper discusses the factors potentially implicated in the excess risks, including the scaffold consideration and deployment technique, and outlines patient and lesion selection, implantation technique, and dual antiplatelet therapy considerations to potentially mitigate this excess risk with the first-generation thick strut Absorb scaffold (Abbott Vascular, Abbott Park, Illinois). It remains to be seen whether these considerations together with technical iterations will ultimately close the gap between scaffolds and metal stents for short-term events while at the same time preserving options for future revascularization once the scaffold bioresorbs.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Diseño de Prótesis , Toma de Decisiones Clínicas , Consenso , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Trombosis Coronaria/etiología , Difusión de Innovaciones , Medicina Basada en la Evidencia , Humanos , Selección de Paciente , Intervención Coronaria Percutánea/efectos adversos , Falla de Prótesis , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
Rev Cardiovasc Med ; 14(2-4): e136-43, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24448255

RESUMEN

Fibromuscular dysplasia (FMD) is a nonatheromatous, noninflammatory arteriopathy with segmental involvement of medium-sized arteries in multiple vascular beds. It most commonly involves the renal and carotid arteries. The etiology is unknown, although various hormonal and mechanical factors have been suggested. The disease can occur at any age but is usually diagnosed in middle-aged individuals, predominantly women. FMD is much more common than previously thought, perhaps affecting as many as 4% of adult women. Clinical manifestations of the internal carotid artery involvement are transitory ischemic attacks or cerebral infarction, as well as nonspecific symptoms such as headache and vertigo. In cases of cerebrovascular events, endovascular or surgical treatment is recommended; therefore, detection of FMD is of considerable importance. The gold standard for diagnosing FMD is catheter angiography (with the classic "string of beads" pattern), but this invasive procedure is only used for patients in whom it is clinically pertinent to proceed with revascularization. The optimal noninvasive modality for diagnosis and quantification for FMD is not known and little information has been recently published about new diagnostic modalities. Although angiography, computed tomography angiography, and magnetic resonance angiography are excellent in confirming the morphologic diagnosis of FMD, they are less accurate in assessing the hemodynamic significance of the lesions. Ultrasonography is useful in assessing the degree of carotid artery stenosis. Use of power Doppler ultrasound improves the ability to detect the morphologic features of carotid FMD.


Asunto(s)
Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Displasia Fibromuscular/diagnóstico por imagen , Ultrasonografía Doppler , Aspirina/administración & dosificación , Fármacos Cardiovasculares/administración & dosificación , Enfermedades de las Arterias Carótidas/tratamiento farmacológico , Femenino , Displasia Fibromuscular/tratamiento farmacológico , Humanos , Angiografía por Resonancia Magnética , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X , Ultrasonografía Doppler en Color
18.
J Thorac Oncol ; 3(7): 800-2, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18594329

RESUMEN

This report describes a patient diagnosed with a cardiac angiosarcoma. The patient presented with cardiac tamponade. A pericardiocentesis revealed a bloody effusion, but cytology was nondiagnostic and a chest computed tomography showed only mediastinal lymphadenopathy. His pericardial effusion recurred 3 weeks later, at which time he was found to have a large right atrial mass which proved to be a cardiac angiosarcoma. This case report underscores the difficulties encountered in the diagnosis of cardiac angiosarcoma.


Asunto(s)
Neoplasias Cardíacas/complicaciones , Hemangiosarcoma/complicaciones , Derrame Pericárdico/etiología , Taponamiento Cardíaco/etiología , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/patología , Hemangiosarcoma/diagnóstico , Hemangiosarcoma/patología , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA