Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
World J Clin Cases ; 9(22): 6443-6449, 2021 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-34435010

RESUMEN

BACKGROUND: In recent years, the rate of immunosuppressed patients has increased rapidly. Invasive fungal infections usually occur in these patients, especially those who have had hematological malignances and received chemotherapy. Fusariosis is a rare pathogenic fungus, it can lead to severely invasive Fusarium infections. Along with the increased rate of immune compromised patients, the incidence of invasive Fusarium infections has also increased from the past few years. Early diagnosis and therapy are important to prevent further development to a more aggressive or disseminated infection. CASE SUMMARY: We report a case of a 19-year-old male acute B-lymphocytic leukemia patient with fungal infection in the skin, eyeball, and knee joint during the course of chemotherapy. We performed skin biopsy, microbial cultivation, and molecular biological identification, and the pathogenic fungus was finally confirmed to be Fusarium solani. The patient was treated with oral 200 mg voriconazole twice daily intravenous administration of 100 mg liposomal amphotericin B once daily, and surgical debridement. Granulocyte colony-stimulating factor was administered to expedite neutrophil recovery. The disseminated Fusarium solani infection eventually resolved, and there was no recurrence at the 3 mo follow-up. CONCLUSION: Our case illustrates the early detection and successful intervention of a systemic invasive Fusarium infection. These are important to prevent progression to a more aggressive infection. Disseminate Fusarium infection requires the systemic use of antifungal agents and immunotherapy. Localized infection likely benefits from surgical debridement and the use of topical antifungal agents.

2.
World J Clin Cases ; 9(8): 1996-2000, 2021 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-33748252

RESUMEN

BACKGROUND: The incidence of infection with Mycobacterium abscessus (M. abscessus) has increased in recent years. This increase is partly associated with invasive cosmetic procedures. CASE SUMMARY: The purpose of this case summary is to increase clinicians' awareness of M. abscessus infection and reduce mycobacterial infection caused by cosmetic procedures. We report the case of a 45-year-old woman who received acetyl hexapeptide-8 (argireline) injections in the forehead and temples, and erythema, nodules, and abscesses appeared at the injection sites after one week. The pus specimens were examined by microbiological culture and confirmed to be positive for M. abscessus. Clarithromycin 500 mg twice daily and moxifloxacin 400 mg once daily were administered for 5 mo and the lesions gradually subsided. CONCLUSION: We report here for the first time a case of infection with M. abscessus after argireline injection. This condition is easily misdiagnosed as a common bacterial infection. Microbiological examinations are helpful for diagnosis and standardized cosmetic procedures can prevent infection with M. abscessus.

3.
Int J Clin Pract ; 75(4): e13732, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32975347

RESUMEN

BACKGROUND: Radiofrequency ablation in patients with atrial fibrillation (AF) is effective but hampered by pulmonary veins reconnection because of insufficient lesions. High power shorter duration ablation (HPSD) was seen to increase efficacy and safety. This analysis aimed to evaluate the clinical benefits of HPSD in patients with AF. METHODS: The Medline, PubMed, Embase, and the Cochrane Library databases were searched for studies comparing HPSD and Low power longer duration (LPLD) ablation. RESULTS: A total of seven trials with 2023 patients were included in the analysis. Pooled analyses demonstrated that HPSD showed a benefit of first-pass pulmonary vein isolation (PVI) [risk ratio (RR): 1.27; 95% confidence interval (CI): 1.18-1.37, P < .001]. HPSD could reduce recurrence of atrial arrhythmias (RR: 0.70; 95% CI: 0.50-0.98, P = .04). Additionally, HPSD was more beneficial in terms of procedural time [Weighted Mean Difference, (WMD): -44.62; 95% CI, -63.00 to -26.23, P < .001], ablation time (WMD: -21.25; 95% CI: -25.36 to -17.13, P < .001), and fluoroscopy time (WMD: -4.13; 95% CI: -7.52 to -0.74, P < .001). Moreover, major complications and esophageal thermal injury (ETI) were similar between two groups (RR: 0.75; 95% CI: 0.44-1.30, P = .31) and (RR: 0.64; 95% CI: 0.17-2.39, P = .51). CONCLUSION: HPSD was safe and efficient for treating AF with clear advantages of procedural features, it also showed benefits of higher first-pass PVI and reducing recurrence of atrial arrhythmias compared with the LPLD. Moreover, major complications and ETI were similar between two groups.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Humanos , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
4.
Clin Cardiol ; 43(12): 1631-1640, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33107625

RESUMEN

BACKGROUND: High power shorter duration (HPSD) ablation seen to increase efficacy and safety treating of atrial fibrillation (AF); however, comparative data between HPSD and low power longer duration (LPLD) ablation are limited. HYPOTHESIS: We thought that HPSD might bring more clinical benefits. The aim of this meta-analysis was to evaluate the clinical benefits of HPSD in patients with AF. METHODS: The Medline, PubMed, Embase, and the Cochrane Library databases were searched for studies comparing HPSD and LPLD ablation. RESULTS: Ten trials with 2467 patients were included in the analysis. Pooled analyses demonstrated that HPSD showed a benefit of first-pass pulmonary vein isolation (PVI) (risk ratio [RR]: 1.20; 95% confidence interval [CI]: 1.10-1.31, P < .001) and recurrence of atrial arrhythmias (RR: 0.73; 95% CI: 0.58-0.91, P = .005). Additionally, HPSD could reduce procedural time (weighted mean difference [WMD]: -42.93; 95% CI, -58.10 to -27.75, P < .001), ablation time (WMD: -21.01; 95% CI: -24.55 to -17.47, P < .001), and fluoroscopy time (WMD: -4.11; 95% CI: -6.78 to -1.45, P < .001). Moreover, major complications and esophageal thermal injury (ETI) were similar between two groups (RR: 0.75; 95% CI: 0.44-1.30, P = .31) and (RR: 0.57; 95% CI: 0.21-1.51, P = .26). CONCLUSIONS: HPSD was safe and efficient for treating AF. Compared with LPLD, HPSD was associated with advantages of procedural features, higher first-pass PVI and reducing recurrence of atrial arrhythmias. Moreover, major complications and ETI were similar between two groups.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/fisiopatología , Venas Pulmonares/cirugía , Fibrilación Atrial/fisiopatología , Humanos , Recurrencia , Resultado del Tratamiento
5.
World J Clin Cases ; 8(17): 3853-3858, 2020 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-32953864

RESUMEN

BACKGROUND: Facial cosmetic procedures become popular for people with a desire to have a younger appearance, and cosmetic technology has developed rapidly over the past several decades. However, increasing complications related to cosmetic injections have been reported, and infection is one of the most serious problems and can cause anxiety and facial injury. We here report a case of Majocchi's granuloma (MG) caused by Trichophyton rubrum after facial injection of hyaluronic acid. CASE SUMMARY: A 37-year-old woman presented to our hospital with a history of red papules, nodules, and abscesses on her left zygomatic arch for 2 mo. She had received a cosmetic injection of hyaluronic acid on the left side of her face prior to the appearance of the lesions. MG caused by Trichophyton rubrum after facial injection of hyaluronic acid was diagnosed based on morphology and molecular biological identification. In vitro antifungal susceptibility testing was conducted according to the Clinical and Laboratory Standards Institute M38-A2 method. Minimal inhibitory concentrations were used to evaluate the antifungal susceptibility. The antifungal agents and their minimal inhibitory concentrations for the strain were terbinafine (< 0.5 µg/mL), itraconazole (0.06 µg/mL), amphotericin B (0.25 µg/mL), fluconazole (32 µg/mL), voriconazole (0.125 µg/mL), posaconazole (0.125 µg/mL), and isavuconazole (0.06 µg/mL). We initially administered 250 mg/d oral terbinafine for 2 mo, but the patient still had painful papules, nodules and abscesses on her face. Then, we adjusted the treatment to itraconazole 400 mg/d for 8 wk based on the in vitro antifungal susceptibility testing results. The skin lesions improved significantly, and there was no recurrence during follow-up. CONCLUSION: This case revealed that facial injection of hyaluronic acid may cause serious MG. Antifungal susceptibility testing should be considered in the treatment of MG caused by Trichophyton rubrum.

6.
Medicine (Baltimore) ; 99(23): e19977, 2020 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-32501965

RESUMEN

The clinical outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) in prior coronary artery bypass graft (pCABG) patients have been investigated; however, the results are inconsistent.The present meta-analysis compared the clinical outcomes of CTO PCI in patients with and without prior CABG (nCABG). The endpoints included technical success, procedural success, all-cause mortality, myocardial infarction (MI), major bleeding, coronary perforation, pericardial tamponade, emergency CABG, and vascular access complication.A total of 7 studies comprising of 11099 patients were included in this meta-analysis. The results showed that compared to nCABG patents, pCABG patients were associated with lower technical success (82.3% versus 87.8%; OR, 0.60; 95% CI, 0.53-0.68; P < .00001; I = 0%) and procedural success (80.4% versus 86.2%; OR, 0.61; 95% CI, 0.53-0.70; P < .00001; I = 10%); a higher risk of all-cause mortality (OR, 2.95; 95% CI, 1.56-5.57; P = 0.0008; I = 0%), MI (OR, 2.30; 95% CI, 1.40-3.80; P = .001; I = 5%), and coronary perforation (OR, 2.16; 95% CI, 1.51-3.08; P < 0.0001; I = 52%). On the other hand, the risk of pericardial tamponade (OR, 0.42; 95% CI, 0.15-1.18; P = .10; I = 21%), major bleeding (OR, 1.51; 95% CI, 0.90-2.53; P = .11; I = 0%), vascular access complication (OR, 1.50; 95% CI, 0.93-2.41; P = .10; I = 0%), and emergency CABG (OR, 0.99; 95% CI, 0.25-3.91; P = .99; I = 0%) was similar in both groups.Compared to nCABG patients, pCABG patients had lower CTO PCI success rates, higher rates of in-hospital mortality, MI, and coronary perforation, and similar risk of pericardial tamponade and vascular complication rates.


Asunto(s)
Puente de Arteria Coronaria/estadística & datos numéricos , Oclusión Coronaria/cirugía , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Complicaciones Posoperatorias/epidemiología , Taponamiento Cardíaco/etiología , Hemorragia/etiología , Humanos , Infarto del Miocardio/etiología , Estudios Observacionales como Asunto , Proyectos de Investigación , Factores de Riesgo , Metaanálisis como Asunto
7.
Clin Cardiol ; 43(5): 500-507, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31943264

RESUMEN

BACKGROUND: Limited comparative data are available regarding catheter ablation (CA) of atrial fibrillation (AF) using second-generation cryoballoon (CB-2) vs radiofrequency (RF) ablation in elderly patients (>75-year-old). HYPOTHESIS: CB-2 ablation may demonstrate different outcomes compared with that using RF ablation for elderly patients with AF. METHOD: Elderly patients with symptomatic drug-refractory AF were included in the study. Pulmonary vein isolation was performed in all patients. RESULTS: A total of 324 elderly patients were included (RF: 176, CB-2:148) from September 2016 to April 2019. The CB-2 was associated with shorter procedure time and left atrial dwell time (112.9 ± 11.1 vs 135.1 ± 9.9 minutes, P < .001; 53.7 ± 8.9 vs 65.1.9 ± 9.0 minutes, P < .001), but marked fluoroscopy utilization (22.1 ± 3.3 vs 18.5 ± 3.6 minutes, P < .001). Complications occurred in 3.3% (CB-2) and 6.2% (RF) of patients with no significant different (P = .307). The length of stay after ablation was shorter, but the costs were higher in the CB-2 group (1.94 vs 2.53 days, P < .001 and 91 132.6 ± 3723.5 vs 81 149.4 ± 6824.1 CNY, P < .001) compared to the RF group. Additionally, the rate of early recurrence of atrial arrhythmia was lower in the CB-2 group (14.2 vs 23.3%, P = .047), but the long-term success rate was similar between two groups. CONCLUSIONS: CB-2 is associated with shorter procedure time, left atrial dwell time, and length of stay after ablation, but its costs and fluoroscopy time are greater than the RF group. Moreover, the rate of complications and long-term success are similar between the two groups.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/estadística & datos numéricos , Ablación por Radiofrecuencia/estadística & datos numéricos , Anciano , Ablación por Catéter/estadística & datos numéricos , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Venas Pulmonares/cirugía , Factores de Riesgo , Irrigación Terapéutica/estadística & datos numéricos , Factores de Tiempo , Resultado del Tratamiento
8.
J Interv Card Electrophysiol ; 59(3): 557-564, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31893337

RESUMEN

PURPOSE: Limited comparative data are available regarding catheter ablation (CA) of atrial fibrillation (AF) using second-generation cryoballoon (CB-2) vs. radiofrequency (RF) ablation in elderly patients (> 75 years old). The present study aimed to compare the costs and clinical outcomes in elderly patients using these two strategies. METHODS: Elderly patients with symptomatic drug-refractory paroxysmal/short-lasting persistent AF were included in the study. Pulmonary vein isolation (PVI) was performed in all patients. RESULTS: A total of 324 elderly patients were included (RF,176; CB-2,148) from September 2016 to April 2019. The CB-2 was associated with shorter procedure time and left atrial dwell time (112.9 ± 11.1 vs. 135.1 ± 9.9 min, P < 0.001; 53.7 ± 8.9 vs. 65.1.9 ± 9.0 min, P < 0.001) but marked fluoroscopy utilization (22.1 ± 3.3 vs. 18.5 ± 3.6 min, P < 0.001). Complications occurred in 3.3% (CB-2) and 6.2% (RF) of patients with no significant different (p = 0.307). The length of stay after ablation was shorter, but the costs were higher in the CB-2 group (1.94 vs. 2.53 days, P < 0.001 and 91,132.6 ± 3723.5 vs. 81,149.4 ± 6824.1 CNY, P < 0.001) compared to the RF group. Additionally, the rate of early recurrence of atrial arrhythmia (ERAA) was lower in the CB-2 group (14.2 vs. 23.3%, P = 0.047), but the long-term success rate was similar between two groups. CONCLUSIONS: CB-2 is associated with shorter procedure time, left atrial dwell time, and length of stay after ablation, as well as lower ERAA, but its costs and fluoroscopy time are greater than the RF group. Moreover, the rate of complications and long-term success is similar between the two groups.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , China/epidemiología , Femenino , Humanos , Masculino , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
9.
Appl Radiat Isot ; 155: 108948, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31655352

RESUMEN

A measurement method of 85Kr using an internal gas proportional counter (IGPC) is presented in this study. The operation conditions of the IGPC were determined and optimized, including the operating voltage, pressure, sample volume, interference from other gas components such as nitrogen or air, and mitigation of the memory effect. The IGPC was calibrated using certified standards, and the detection efficiency was approximately 58% for typical samples. A lower limit of detection of approximately 0.11 MBq/m3(Kr) was achieved after counting for 5 h with 1 mL pure Kr, corresponding to the atmospheric activity concentration of 0.18 Bq/m3 (air). It was shown that the IGPC could be used effectively for measuring 85Kr.

10.
Clin Cardiol ; 43(3): 267-274, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31743474

RESUMEN

BACKGROUND: The ThermoCool Smarttouch Surroundflow catheter (STSFc) is an advanced catheter, which integrating contact force sensing and surroundflow technology. However, comparative data between STSFc and contact force sensing catheter (Thermocool SmartTouch catheter [STc]) are limited. HYPOTHESIS: We thought that STSFc might bring more clinical benefits. The aim of this meta-analysis was to compare the safety and efficiency between the STSFc and the STc for treatment of atrial fibrillation (AF). METHODS: The Medline, PubMed, Embase, and Cochrane Library databases were searched for studies comparing STSFc and STc. RESULTS: Four trials involving 727 patients were included in the study. Pool-analyses demonstrated that, as compared STc ablation, STSFc ablation was more beneficial in terms of procedural times (standard mean difference [SMD]: -0.22; 95% confidence interval [CI], -0.37 to -0.07, P = .005) and irrigation fluid volume (SMD: -1.94; 95% CI, -2.65 to -1.22, P < .0001). There was no significant difference between STSFc and STc (risk ratio [RR]: 1.02; 95% CI: 0.86 to 1.21, P = .79) for free from AF. Evidence of complications were low and similar for both groups (RR: 0.83; 95% CI: 0.19-3.55, P = .80). Additionally, patients administered STSFc ablation tended to have shorter fluoroscopic times (SMD: -0.20; 95% CI, -0.63-0.23, P = .21). CONCLUSIONS: STSFc ablation was associated with reducing procedural times and irrigation fluid volume. Further, STSFc ablation tended to shorten fluoroscopic times. Therefore, STSFc ablation would be a better choice for AF patients especially in patients with heart failure.


Asunto(s)
Fibrilación Atrial/cirugía , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Irrigación Terapéutica/instrumentación , Transductores de Presión , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Temperatura , Irrigación Terapéutica/efectos adversos , Resultado del Tratamiento
11.
Coron Artery Dis ; 31(3): 208-214, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31703014

RESUMEN

BACKGROUND: Several studies have evaluated the long-term clinical outcomes of periprocedural myocardial injury for chronic total occlusions patients. However, the results of these studies were inconsistent. To determine whether the periprocedural myocardial injury has adverse effects on long-term clinical outcomes in chronic total occlusion patients undergoing percutaneous coronary intervention. METHODS: We searched Cochrane Library, PubMed, and Embase for eligible articles from their date of inception up to March 2019. Long-term clinical outcomes included major adverse cardiac events, all-cause death, cardiac death, myocardial infarction, and target vessel revascularization. Odds ratios with 95% confidence intervals were calculated as summary statistics by using Review Manager software. RESULTS: A total of 8 observational studies involving 5879 chronic total occlusions patients were included in this meta-analysis. These results of this meta-analysis indicated that periprocedural myocardial injury was associated with a higher risk of major adverse cardiac events (odds ratio, 1.94; 95% confidence interval, 1.22-3.08; P = 0.005), a higher risk of all-cause death (odds ratio, 1.30; 95% confidence interval, 1.02-1.64; P = 0.03), a higher risk of cardiac death (odds ratio, 2.59; 95% confidence interval, 1.41-4.78; P = 0.002), a higher risk of myocardial infarction (odds ratio, 3.07; 95% confidence interval, 1.90-4.98; P < 0.00001), and a higher risk of target vessel revascularization (odds ratio, 2.07; 95% confidence interval, 1.35-3.16; P=0.0008) than non-periprocedural myocardial injury. CONCLUSION: Periprocedural myocardial injury was associated with significantly increased risk of major adverse cardiac events, all-cause death, cardiac death, myocardial infarction, and target vessel revascularization in chronic total occlusion patients undergoing percutaneous coronary intervention at long-term follow-up.


Asunto(s)
Oclusión Coronaria/cirugía , Complicaciones Intraoperatorias/epidemiología , Mortalidad , Infarto del Miocardio/epidemiología , Isquemia Miocárdica/epidemiología , Miocardio , Intervención Coronaria Percutánea , Enfermedades Cardiovasculares/mortalidad , Enfermedad Crónica , Humanos , Revascularización Miocárdica/estadística & datos numéricos , Oportunidad Relativa , Periodo Perioperatorio , Pronóstico , Factores de Riesgo , Resultado del Tratamiento
12.
J Thromb Thrombolysis ; 50(1): 201-210, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31686297

RESUMEN

Cumulative reports comparing the efficacy and safety outcomes between uninterrupted NOACs and vitamin K antagonists (VKA) in AF ablation had been freshly published. This meta-analysis aimed at offering a more comprehensive evaluation between these two anticoagulants in uninterrupted strategy. We searched in PUBMED, EMBASE, and Cochrane Library (inception to June 10, 2019) for eligible studies. Fixed-effects model was preferred in pooled analysis if I2 < 50%. Publication bias was also evaluated. A total of 23 studies involving 12,725 individuals were analyzed in this literature. There were no difference between uninterrupted NOACs and VKA groups in incidence of Stroke/TIA (RR 0.98, 95% CI 0.54-1.77, P = 0.93, I2 = 0%), silent cerebral embolism (RR 1.09, 95% CI 0.82-1.43, P = 0.56, I2 = 0%), minor bleeding complication (RR 0.97, 95% CI 0.83-1.14, P = 0.73, I2 = 0%), cardiac tamponade (RR 0.95, 95% CI 0.63-1.42, P = 0.80, I2 = 0%). Uninterrupted NOACs was associated with significantly lower major bleeding incidence (RR 0.67, 95% CI 0.49-0.92, P = 0.01, I2 = 0%), pericardial effusion (RR 0.75, 95% CI 0.56-1.00, P = 0.048, I2 = 9%). In sub-analysis, no difference was found in all sub-analyses for Stroke/TIA while significant major bleeding risk reduction in uninterrupted NOACs was identified in the subgroup of CHA2DS2-VASc score ≥ 2 and target activated clotting time (ACT) > 300 s. In conclusions, uninterrupted NOACs was more effective than uninterrupted VKA in reducing major bleeding and pericardial effusion risk without increasing thromboembolism risk, and the benefits of uninterrupted NOACs on major bleeding complication could be more pronounced if CHA2DS2-VASc score ≥ 2 or target ACT > 300 s.


Asunto(s)
Anticoagulantes , Fibrilación Atrial/terapia , Ablación por Catéter , Hemorragia , Tromboembolia , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Anticoagulantes/clasificación , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Hemorragia/inducido químicamente , Hemorragia/prevención & control , Humanos , Ajuste de Riesgo , Tromboembolia/etiología , Tromboembolia/prevención & control
13.
Kardiol Pol ; 78(1): 20-29, 2020 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-31688837

RESUMEN

BACKGROUND: Clinical outcomes of catheter ablation for persistent atrial fibrillation (AF) remain discouraging. AIM: This meta­analysis aimed to compare cryoballoon ablation (CBA) with radiofrequency ablation (RFA) for persistent AF. METHODS: A systematic search of the PubMed, EMBASE, and Cochrane Library databases was performed for studies comparing the outcomes between CBA and RFA. Seven trials including 934 patients were analyzed. RESULTS: There were no differences between groups in terms of freedom from atrial arrhythmia (risk ratio [RR], 1.04; 95% CI, 0.93-1.15; P = 0.52; I2 = 0%), procedural complications (RR, 0.91; 95% CI, 0.52-1.59; P = 0.74; I2 = 0%), atrial fibrillation or atrial tachycardia relapse during the blanking period (RR, 0.73; 95% CI, 0.50-1.06; P = 0.1; I2 = 9%), repeat ablation (RR, 0.74; 95% CI, 0.45-1.21; P = 0.23; I2 = 62%), and vascular complications (RR, 0.98; 95% CI, 0.42-2.27; P = 0.97; I2 = 0%). Cryoballoon ablation increased the incidence of conversion to sinus rhythm during ablation (RR, 1.69; 95% CI, 1.01-2.83; P = 0.046; I2 = 0%) and phrenic nerve palsy (PNP; RR, 3.05; 95% CI, 0.95-9.8; P = 0.06; I2 = 0%), while RFA increased the risk of cardiac tamponade (RR, 0.27; 95% CI, 0.06-1.25; P = 0.09; I2 = 0%). Subanalyses revealed a lower incidence of recurrent atrial arrhythmia and repeat ablation during CBA without touch­up RFA in pulmonary vein isolation. CONCLUSIONS: CBA provides an alternative technique for persistent AF ablation. It might reduce the risk of repeat ablation and cardiac tamponade but increase the risk of PNP.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
14.
Medicine (Baltimore) ; 98(19): e15490, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31083185

RESUMEN

BACKGROUND: Lead-related complication is an important drawback of trans-venous implantable cardioverter-defibrillators (TV-ICD). The subcutaneous ICD (S-ICD) was developed to overcome ICD lead associated complications; however, whether the S-ICD confers enhanced clinical benefits compared with TV-ICD remains unclear. The present systematic review and meta-analysis aimed to assess TV-ICD and S-ICD for safety, efficacy, and in-hospital outcomes in the prevention of sudden cardiac death (SCD) in patients not requiring pacing. METHODS: The Medline, PubMed, EmBase, and Cochrane Library databases were searched for studies comparing TV-ICD and S-ICD. RESULTS: A total of 9 eligible studies, including 5 propensity-matched case-control, 3 retrospective, and 1 cross-sectional studies were identified, assessing 7361 patients in all. Pool analyses demonstrated that SICD were associated with lower lead-related complication rates [odds ratio (OR) = 0.13; 95% confidence interval [CI] 0.05-0.33; I = 0%], and S-ICD was more beneficial in terms of reducing ICD shocks [OR = 0.48; 95% CI 0.32-0.72, I = 4%]. In addition, the patients administered S-ICD tend to have shorter length of hospital stay after implantation (SMD = -0.06; 95% CI -0.11 to 0.00, I = 0%) and reduce total complication rates (OR = 0.72; 95% CI 0.50-1.03; I = 18%), non-decreased quality of life (QoL). Moreover, both devices appeared to perform equally well with respect to infection rate and death. CONCLUSIONS: Available overall data suggested that S-ICD is associated with reducing lead-related complications, ICD shocks. In addition, S-ICD has tendency to shorten hospitalization and reduce total complications, although the difference is no significant. Equivalent death rate, infection, and QoL were found between 2 groups. Therefore, S-ICD could be considered an alternative approach to TV-ICD in appropriate patients for SCD prevention.


Asunto(s)
Enfermedades Cardiovasculares/terapia , Desfibriladores Implantables , Desfibriladores Implantables/efectos adversos , Falla de Equipo , Humanos , Complicaciones Posoperatorias
15.
IEEE Int Conf Rehabil Robot ; 2017: 919-924, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28813938

RESUMEN

The most important step for lower extremity exoskeleton is to infer human motion intent (HMI), which contributes to achieve human exoskeleton collaboration. Since the user is in the control loop, the relationship between human robot interaction (HRI) information and HMI is nonlinear and complicated, which is difficult to be modeled by using mathematical approaches. The nonlinear approximation can be learned by using machine learning approaches. Gaussian Process (GP) regression is suitable for high-dimensional and small-sample nonlinear regression problems. GP regression is restrictive for large data sets due to its computation complexity. In this paper, an online sparse GP algorithm is constructed to learn the HMI. The original training dataset is collected when the user wears the exoskeleton system with friction compensation to perform unconstrained movement as far as possible. The dataset has two kinds of data, i.e., (1) physical HRI, which is collected by torque sensors placed at the interaction cuffs for the active joints, i.e., knee joints; (2) joint angular position, which is measured by optical position sensors. To reduce the computation complexity of GP, grey relational analysis (GRA) is utilized to specify the original dataset and provide the final training dataset. Those hyper-parameters are optimized offline by maximizing marginal likelihood and will be applied into online GP regression algorithm. The HMI, i.e., angular position of human joints, will be regarded as the reference trajectory for the mechanical legs. To verify the effectiveness of the proposed algorithm, experiments are performed on a subject at a natural speed. The experimental results show the HMI can be obtained in real time, which can be extended and employed in the similar exoskeleton systems.


Asunto(s)
Dispositivo Exoesqueleto , Extremidad Inferior/fisiología , Aprendizaje Automático , Dispositivos de Autoayuda , Algoritmos , Diseño de Equipo , Humanos , Articulación de la Rodilla/fisiología , Movimiento/fisiología , Distribución Normal
16.
Cell Physiol Biochem ; 42(1): 115-125, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28494466

RESUMEN

OBJECTIVE: This study aimed to explore the effects of STAT3 targeting by let-7a on T-cell proliferation and IFN-γ secretion in psoriasis. METHODS: From January 2013 to January 2015, 40 patients with psoriasis (psoriasis group) and 38 volunteers undergoing plastic surgery (control group) were enrolled in this study. Pearson correlation analysis was performed to evaluate the correlation between let-7a and STAT3 expression. T-cells were isolated and subjected to different transfection methods. A dual luciferase reporter assay was carried out to confirm STAT3 as a target gene of let-7a. Let-7a, STAT3 and IFN-γ mRNA expression was detected by quantitative real-time fluorescent polymerase chain reaction (qRT-PCR), and pSTAT3 protein levels were determined by Western blot. T-cell proliferation was evaluated with a cell counting kit-8 (CCK-8) assay. RESULTS: The level of STAT3 mRNA and pSTAT3 was higher, but let-7a expression was lower in the psoriasis group than the control group. Pearson correlation analysis indicated that STAT3 expression was negatively correlated with let-7a expression. T-cells transfected with inhibitors exhibited greater IFN-γ mRNA expression and T-cell proliferation than transfected T-cells and T-cells transfected with a non-sense sequence, while T-cells transfected with let-7a mimics exhibited lower IFN-γ mRNA expression and T-cell proliferation than transfected T-cells and T-cells transfected with a non-sense sequence. This suggested that siRNA-STAT3 could reverse the increase in IFN-y mRNA expression and T-cell proliferation induced by let-7a inhibitors. CONCLUSION: Our results demonstrated that let-7a inhibits T-cell proliferation and IFN-γ secretion by down-regulating STAT3 in psoriasis.


Asunto(s)
Interferón gamma/metabolismo , MicroARNs/metabolismo , Psoriasis/genética , Psoriasis/patología , Factor de Transcripción STAT3/genética , Factor de Transcripción STAT3/metabolismo , Adulto , Antagomirs/metabolismo , Secuencia de Bases , Estudios de Casos y Controles , Proliferación Celular , Células Cultivadas , Regulación hacia Abajo , Femenino , Humanos , Interferón gamma/genética , Masculino , MicroARNs/antagonistas & inhibidores , MicroARNs/genética , Persona de Mediana Edad , Psoriasis/metabolismo , Interferencia de ARN , ARN Interferente Pequeño/metabolismo , Factor de Transcripción STAT3/antagonistas & inhibidores , Alineación de Secuencia , Índice de Severidad de la Enfermedad , Linfocitos T/citología , Linfocitos T/metabolismo
17.
J Interv Card Electrophysiol ; 48(3): 351-366, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28063111

RESUMEN

PURPOSE: The present systematic review and meta-analysis aimed to assess and compare the safety and efficacy of radiofrequency (RF) and cryoballoon (CB) ablation for paroxysmal atrial fibrillation (PAF). RF and CB ablation are two frequently used methods for pulmonary vein isolation in PAF, but which is a better choice for PAF remains uncertain. METHODS: A systematic review was conducted in Medline, PubMed, Embase, and Cochrane Library. All trials comparing RF and CB ablation were screened and included if the inclusion criteria were met. RESULTS: A total of 38 eligible studies, 9 prospective randomized or randomized controlled trials (RCTs), and 29 non- RCTs were identified, adding up to 15,496 patients. Pool analyses indicated that CB ablation was more beneficial in terms of procedural time [standard mean difference = -0.58; 95% confidence interval (CI), -0.85 to -0.30], complications without phrenic nerve injury (PNI) [odds ratio (OR) = 0.79; 95% CI, 0.67-0.93; I 2 = 16%], and recrudescence (OR = 0.83; 95% CI, 0.70-0.97; I 2 = 63%) for PAF; however, the total complications of CB was higher than RF. The subgroup analysis found that, compared with non-contact force radiofrequency (non-CF-RF), both first-generation cryoballoon (CB1) and second-generation cryoballoon (CB2) ablation could reduce complications with PNI, procedural time, and recrudescence. However, the safety and efficacy of CB2 was similar to those of CF-RF. CONCLUSION: Available overall and subgroup data suggested that both CB1 and CB2 were more beneficial than RF ablation, and the main advantages were reflected in comparing them with non-CF-RF. However, CF-RF and CB2 showed similar clinical benefits.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/estadística & datos numéricos , Criocirugía/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Fibrilación Atrial/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Prevalencia , Factores de Riesgo
18.
Medicine (Baltimore) ; 96(48): e8947, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29310391

RESUMEN

BACKGROUND: Premature ventricular contractions (PVCs) originating from aortic sinus cusps is not infrequent and can be eliminated effectively by radiofrequency ablation with rare complications. However, after a review of the medical literature, and to our knowledge, this is the first case of successful idiopathic aortic sinus cusps-PVC-ablation using a 3-dimensional (3D) mapping system in an adult with dextrocardia. METHODS: A 62-year-old male with dextrocardia and situs inversus underwent catheter ablation of frequent PVCs. The electrocardiograms (ECG) were recorded by placement of the electrodes in reversed positions. The PVCs exhibited left bundle branch block and inferior axis QRS morphology with transition at leads V2-V3. The activation mapping indicated the earliest site of ventricular activation between the left and right aortic sinus cusps, highlighting that catheter ablation was successful at this point. RESULTS: The catheter ablation was successful between the left and right aortic sinus cusps, and the PVCs were not detected for the subsequent 30 min following the procedure as well as for the rest of the hospital stay. CONCLUSION: Combined with ECG electrodes in reversed positions and 3D electroanatomical mapping system, catheter ablation of PVCs originating from aortic sinus cusps in patients with dextrocardia can be safely and effectively performed.


Asunto(s)
Ablación por Catéter , Dextrocardia/complicaciones , Seno Aórtico/cirugía , Complejos Prematuros Ventriculares/cirugía , Dextrocardia/diagnóstico por imagen , Dextrocardia/fisiopatología , Electrocardiografía , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Seno Aórtico/diagnóstico por imagen , Seno Aórtico/fisiopatología , Complejos Prematuros Ventriculares/complicaciones , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/fisiopatología
19.
Pacing Clin Electrophysiol ; 39(12): 1404-1409, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27807872

RESUMEN

Heart failure (HF) is associated with changes in cardiac substrate utilization and energy metabolism, including a decline in high-energy phosphate content, mitochondrial dysfunction, and phosphotransfer enzyme deficiency. A shift toward glucose metabolism was noted in the end stage of HF in animals, although HF in humans may not be associated with a shift toward predominant glucose utilization. Deficiencies of micronutrients are well-established causes of cardiomyopathy. Correction of these deficits can improve heart function. The genes governing the energy metabolism were predominantly underexpressed in nonischemic cardiomyopathy and hypertrophic cardiomyopathy but were overexpressed in ischemic cardiomyopathy. Cardiac resynchronization therapy (CRT) has been proven to increase cardiac efficiency without increasing myocardial oxygen consumption. Altered myocardial metabolism is normalized by CRT to improve ventricular function.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/prevención & control , Insuficiencia Cardíaca/fisiopatología , Corazón/fisiopatología , Enfermedades Metabólicas/prevención & control , Enfermedades Metabólicas/fisiopatología , Medicina Basada en la Evidencia , Femenino , Glucosa/metabolismo , Humanos , Masculino , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...