Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Curr Opin Anaesthesiol ; 36(5): 485-490, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37552014

RESUMEN

PURPOSE OF REVIEW: To provide an overview of anesthetic techniques for innovative diagnostic and therapeutic epilepsy procedures performed on pediatric patients. RECENT FINDINGS: Recent studies have been published on the anesthetic consideration for functional MRI, robotic-assisted stereoelectroencephalography, high-intensity focused ultrasound, and magnetoencephalography. These articles describe the anesthesia management, risks, and outcome for these procedures. SUMMARY: The number of diagnostic and treatment options being used for the management of pediatric epilepsy has increased significantly. In the past few years, a handful of articles have been published, which describe the anesthetic considerations for these procedures. These studies are helpful to anesthesiologists who are planning an upcoming anesthetic or who are developing a 'best practice' model for their institution. Because unlike other diagnostic studies, failure to understand what effects anesthetics have on the brain, may negate the utility of the study. Although these new findings can be used to provide some anesthesia practice recommendations for epilepsy procedures in which the best management is still unclear, additional high-quality studies are needed.


Asunto(s)
Anestesia , Anestésicos , Epilepsia , Niño , Humanos , Anestesia/efectos adversos , Anestesia/métodos , Epilepsia/diagnóstico , Epilepsia/terapia , Encéfalo , Anestesiólogos
2.
Anesth Analg ; 125(4): 1192-1199, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28338490

RESUMEN

BACKGROUND: In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. METHODS: Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear regression model. Analysis of variance was used to determine whether the absolute log proportional error differed by the intended injection volume. Interindividual and intraindividual deviation from the intended injection volume was also characterized. RESULTS: As the intended injection volumes decreased, the absolute log proportional injection volume error increased (analysis of variance, P < .0018). The exploratory analysis revealed no significant difference in the standard deviations of the log proportional errors for injection volumes between physicians and pediatric PACU nurses; however, the difference in absolute bias was significantly higher for nurses with a 2-sided significance of P = .03. CONCLUSIONS: Clinically significant dose variation occurs when injecting volumes ≤0.5 mL. Administering small volumes of medications may result in unintended medication administration errors.


Asunto(s)
Anestesiólogos/normas , Composición de Medicamentos/métodos , Composición de Medicamentos/normas , Enfermeras y Enfermeros/normas , Preparaciones Farmacéuticas/normas , Jeringas/normas , Calibración/normas , Humanos , Inyecciones , Preparaciones Farmacéuticas/química , Tuberculina/administración & dosificación , Tuberculina/química
3.
Paediatr Anaesth ; 19(2): 138-44, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19207899

RESUMEN

OBJECTIVES: Propofol is a sedative-hypnotic drug commonly used to anesthetize children undergoing esophagogastroduodenoscopy (EGD). Dexmedetomidine is a highly selective alpha-2 adrenergic receptor agonist that has been utilized in combination with propofol to provide anesthesia. There is currently no information regarding the effect of intravenous dexmedetomidine on the propofol plasma concentration-response relationship during EGD in children. This study aimed to investigate the pharmacodynamic interaction of propofol and dexmedetomidine when used in combination for children undergoing EGD. METHODS: A total of 24 children undergoing EGD, ages 3-10 years, were enrolled in this study. Twelve children received dexmedetomidine 1 microg x kg(-1) given over 10 min as well as a continuous infusion of propofol delivered by a computer-assisted target-controlled infusion (TCI) system with target plasma concentrations ranging from 2.8 to 4.0 microg x ml(-1) (DEX group). Another group of 12 children undergoing EGD also received propofol administered by TCI targeting comparable plasma concentrations without dexmedetomidine (control group). We used logistic regression to predict plasma propofol concentrations at which 50% of the patients exhibited minimal response to stimuli (EC50 for anesthesia). RESULTS: The EC50 +/- SE values in the control and DEX groups were 3.7 +/- 0.4 microg x ml(-1) and 3.5 +/- 0.2 microg x ml(-1), respectively. There was no significant shift in the propofol concentration-response curve in the presence of dexmedetomidine. CONCLUSION: The EC50 of propofol required to produce adequate anesthesia for EGD in children was unaffected by a concomitant infusion of dexmedetomidine 1 microg x kg(-1) given over 10 min.


Asunto(s)
Dexmedetomidina/farmacocinética , Endoscopía del Sistema Digestivo , Propofol/farmacocinética , Niño , Preescolar , Dexmedetomidina/farmacología , Quimioterapia Combinada , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Propofol/farmacología , Análisis de Regresión
4.
J Educ Eval Health Prof ; 6: 3, 2009 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-20046456

RESUMEN

High-fidelity patient simulation (HFPS) has been hypothesized as a modality for assessing competency of knowledge and skill in patient simulation, but uniform methods for HFPS performance assessment (PA) have not yet been completely achieved. Anesthesiology as a field founded the HFPS discipline and also leads in its PA. This project reviews the types, quality, and designated purpose of HFPS PA tools in anesthesiology. We used the systematic review method and systematically reviewed anesthesiology literature referenced in PubMed to assess the quality and reliability of available PA tools in HFPS. Of 412 articles identified, 50 met our inclusion criteria. Seventy seven percent of studies have been published since 2000; more recent studies demonstrated higher quality. Investigators reported a variety of test construction and validation methods. The most commonly reported test construction methods included "modified Delphi Techniques" for item selection, reliability measurement using inter-rater agreement, and intra-class correlations between test items or subtests. Modern test theory, in particular generalizability theory, was used in nine (18%) of studies. Test score validity has been addressed in multiple investigations and shown a significant improvement in reporting accuracy. However the assessment of predicative has been low across the majority of studies. Usability and practicality of testing occasions and tools was only anecdotally reported. To more completely comply with the gold standards for PA design, both shared experience of experts and recognition of test construction standards, including reliability and validity measurements, instrument piloting, rater training, and explicit identification of the purpose and proposed use of the assessment tool, are required.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA