Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 291
1.
J Med Econ ; : 1-15, 2024 Jun 18.
Article En | MEDLINE | ID: mdl-38889094

Background and aimsCardiac ablation is a well-established method for treating atrial fibrillation (AF). Pulsed field ablation (PFA) is a non-thermal therapeutic alternative to radiofrequency ablation (RFA) and cryoballoon ablation (CRYO). PFA uses high-voltage electric pulses to target cells. The present analysis aims to quantify the costs, outcomes, and resources associated with these three ablation strategies for paroxysmal AF.MethodsReal-world clinical data were prospectively collected during index hospitalization by three European medical centers (Belgium, Germany, the Netherlands) specialized in cardiac ablation. These data included procedure times (pre-procedural, skin-to-skin and post-procedural), resource use, and staff burden. Data regarding complications associated with each of the three treatment options and redo procedures were extracted from the literature. Costs were collected from hospital economic formularies and published cost databases. A cost-consequence model from the hospital perspective was built to estimate the impact of the three treatment options in terms of effectiveness and costs.ResultsAcross the three centers, N = 91 patients were included over a period of 12 months. A significant difference was seen in pre-procedural time (mean ± SD, PFA: 13.6 ± 3.7 min, CRYO: 18.8 ± 6.6 min, RFA: 20.4 ± 6.4 min; p < 0.001). Procedural time (skin-to-skin) was also different across alternatives (PFA: 50.9 ± 22.4 min, CRYO: 74.5 ± 24.5 min, RFA: 140.2 ± 82.4 min; p < 0.0001). The model reported an overall cost of €216,535 per 100 patients treated with PFA, €301,510 per 100 patients treated with CRYO and €346,594 per 100 patients treated with RFA. Overall, the cumulative savings associated with PFA (excluding kit costs) were €850 and €1,301 per patient compared to CRYO and RFA, respectively.ConclusionPFA demonstrated shorter procedure time compared to CRYO and RFA. Model estimates indicate that these time savings result in cost savings for hospitals and reduce outlay on redo procedures. Clinical practice in individual hospitals varies and may impact the ability to transfer results of this analysis to other settings.

2.
J Am Heart Assoc ; 13(10): e033148, 2024 May 21.
Article En | MEDLINE | ID: mdl-38726893

BACKGROUND: Brugada syndrome (BrS) has been associated with sudden cardiac death in otherwise healthy subjects, and drug-induced BrS accounts for 55% to 70% of all patients with BrS. This study aims to develop a deep convolutional neural network and evaluate its performance in recognizing and predicting BrS diagnosis. METHODS AND RESULTS: Consecutive patients who underwent ajmaline testing for BrS following a standardized protocol were included. ECG tracings from baseline and during ajmaline were transformed using wavelet analysis and a deep convolutional neural network was separately trained to (1) recognize and (2) predict BrS type I pattern. The resultant networks are referred to as BrS-Net. A total of 1188 patients were included, of which 361 (30.3%) patients developed BrS type I pattern during ajmaline infusion. When trained and evaluated on ECG tracings during ajmaline, BrS-Net recognized a BrS type I pattern with an AUC-ROC of 0.945 (0.921-0.969) and an AUC-PR of 0.892 (0.815-0.939). When trained and evaluated on ECG tracings at baseline, BrS-Net predicted a BrS type I pattern during ajmaline with an AUC-ROC of 0.805 (0.845-0.736) and an AUC-PR of 0.605 (0.460-0.664). CONCLUSIONS: BrS-Net, a deep convolutional neural network, can identify BrS type I pattern with high performance. BrS-Net can predict from baseline ECG the development of a BrS type I pattern after ajmaline with good performance in an unselected population.


Ajmaline , Brugada Syndrome , Deep Learning , Electrocardiography , Humans , Brugada Syndrome/diagnosis , Brugada Syndrome/physiopathology , Brugada Syndrome/chemically induced , Electrocardiography/drug effects , Male , Female , Ajmaline/adverse effects , Middle Aged , Adult , Predictive Value of Tests , Retrospective Studies
3.
JACC Case Rep ; 29(12): 102356, 2024 Jun 19.
Article En | MEDLINE | ID: mdl-38764571

Catheter ablation of septal ventricular tachycardia (VT) is challenging. Pulsed field ablation is a promising technology, potentially reaching deep substrates. We report the first sequential unipolar biventricular pulsed field ablation targeting refractory septal VT. Besides, we illustrate the importance of searching underlying cardiomyopathy in patients with recurrent multiple morphology VTs and normal magnetic resonance imaging.

4.
J Clin Med ; 13(5)2024 Feb 26.
Article En | MEDLINE | ID: mdl-38592135

Sudden cardiac death (SCD) accounts for a substantial proportion of mortality in heart failure with reduced ejection fraction (HFrEF), frequently triggered by ventricular arrhythmias (VA). This review aims to analyze the pathophysiological mechanisms underlying VA and SCD in HFrEF and evaluate the effectiveness of guideline-directed medical therapy (GDMT) in reducing SCD. Beta-blockers, angiotensin receptor-neprilysin inhibitors, and mineralocorticoid receptor antagonists have shown significant efficacy in reducing SCD risk. While angiotensin-converting enzyme inhibitors and angiotensin receptor blockers exert beneficial impacts on the renin-angiotensin-aldosterone system, their direct role in SCD prevention remains less clear. Emerging treatments like sodium-glucose cotransporter 2 inhibitors show promise but necessitate further research for conclusive evidence. The favorable outcomes of those molecules on VA are notably attributable to sympathetic nervous system modulation, structural remodeling attenuation, and ion channel stabilization. A multidimensional pharmacological approach targeting those pathophysiological mechanisms offers a complete and synergy approach to reducing SCD risk, thereby highlighting the importance of optimizing GDMT for HFrEF. The current landscape of HFrEF pharmacotherapy is evolving, with ongoing research needed to clarify the full extent of the anti-arrhythmic benefits offered by both existing and new treatments.

6.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Article En | MEDLINE | ID: mdl-38310489

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Acute Kidney Injury , Atrial Fibrillation , Catheter Ablation , Hemoglobinuria , Humans , Atrial Fibrillation/surgery , Male , Female , Catheter Ablation/adverse effects , Catheter Ablation/methods , Middle Aged , Acute Kidney Injury/prevention & control , Acute Kidney Injury/etiology , Aged , Hemoglobinuria/etiology , Hemoglobinuria/prevention & control , Creatinine/blood , Retrospective Studies , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Fluid Therapy/methods
7.
Heart Rhythm ; 2024 Jan 20.
Article En | MEDLINE | ID: mdl-38246567

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.

8.
Heart Rhythm ; 21(6): 780-787, 2024 Jun.
Article En | MEDLINE | ID: mdl-38290688

BACKGROUND: Pulsed field ablation (PFA) is selective for the myocardium. However, vagal responses and reversible effects on ganglionated plexi (GP) are observed during pulmonary vein isolation (PVI). Anterior-right GP ablation has been proven to effectively prevent vagal responses during radiofrequency-based PVI. OBJECTIVE: The purpose of this study was to test the hypothesis that PFA-induced transient anterior-right GP modulation when targeting the right superior pulmonary vein (RSPV) before any other pulmonary veins (PVs) may effectively prevent intraprocedural vagal responses. METHODS: Eighty consecutive paroxysmal atrial fibrillation patients undergoing PVI with PFA were prospectively included. In the first 40 patients, PVI was performed first targeting the left superior pulmonary vein (LSPV-first group). In the last 40 patients, RSPV was targeted first, followed by left PVs and right inferior PV (RSPV-first group). Heart rate (HR) and extracardiac vagal stimulation (ECVS) were evaluated at baseline, during PVI, and postablation to assess GP modulation. RESULTS: Vagal responses occurred in 31 patients (78%) in the LSPV-first group and 5 (13%) in the RSPV-first group (P <.001). Temporary pacing was needed in 14 patients (35%) in the LSPV-first group and 3 (8%) in the RSPV-first group (P = .003). RSPV isolation was associated with similar acute HR increase in the 2 groups (13 ± 11 bpm vs 15 ± 12 bpm; P = .3). No significant residual changes in HR or ECVS response were documented in both groups at the end of the procedure compared to baseline (all P >.05). CONCLUSION: PVI with PFA frequently induced vagal responses when initiated from the LSPV. Nevertheless, an RSPV-first approach promoted transient HR increase and reduced vagal response occurrence.


Atrial Fibrillation , Catheter Ablation , Heart Rate , Pulmonary Veins , Vagus Nerve , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Catheter Ablation/methods , Middle Aged , Heart Rate/physiology , Vagus Nerve/physiopathology , Vagus Nerve/physiology , Prospective Studies , Heart Conduction System/physiopathology , Aged , Treatment Outcome , Ganglia, Autonomic/physiopathology , Ganglia, Autonomic/surgery , Follow-Up Studies
10.
JACC Clin Electrophysiol ; 10(3): 477-486, 2024 Mar.
Article En | MEDLINE | ID: mdl-38069973

BACKGROUND: Studies have reported development of pulmonary hypertension (PH) secondary to reduced LA compliance following AF ablation. OBJECTIVES: This study aimed to compare the risk of worsening of baseline PH between non-paroxysmal AF patients undergoing pulsed-field ablation (PFA) and standard radiofrequency ablation (RFA). METHODS: This multicenter study included 28 nonparoxysmal AF patients with PH undergoing a PFA-based ablation procedure after >1 failed RFA. A cohort of 28 AF patients with PH, scheduled for repeat RFA, 1:1 propensity-score matched using a multivariable logistic model, were used as the comparator group. Right heart catheterization and echocardiography were performed before and after the procedure to assess the pulmonary artery pressure (PAP). PH was defined as resting mean PAP of >20 mm Hg. RESULTS: The baseline characteristics of the PFA and propensity-matched RFA groups were comparable. The mean PAP assessments at baseline, follow-up, and change from baseline were analyzed. The groups had comparable baseline mean pulmonary artery pressures (mPAP) (P = 0.177). After adjustment for baseline mPAP in an analysis of covariance model, the least-squares means change at 3 months after ablation was -1.71 ± 1.03 mm Hg and 19.67 ± 1.03 mm Hg in PFA and RFA, respectively (P <0.001). CONCLUSIONS: In this propensity-matched population, no worsening of mPAP was detected following pulsed-field ablation in patients with pre-existing PH undergoing a repeat procedure for recurrence.


Atrial Fibrillation , Catheter Ablation , Hypertension, Pulmonary , Radiofrequency Ablation , Humans , Atrial Fibrillation/surgery , Hypertension, Pulmonary/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Radiofrequency Ablation/adverse effects , Cardiac Catheterization
11.
J Interv Card Electrophysiol ; 67(4): 827-836, 2024 Jun.
Article En | MEDLINE | ID: mdl-38102499

BACKGROUND: Catheter ablation has become an established treatment option for premature ventricular complexes (PVCs). The use of fluoroscopy exposes patients and medical staff to potentially harmful stochastic and deterministic effects of ionizing radiations. We sought to analyze procedural outcomes in terms of safety and efficacy using a "zero fluoroscopy" approach for catheter ablation of PVCs. METHODS: The present retrospective, multicenter, observational study included 131 patients having undergone catheter ablation of PVCs using "zero fluoroscopy" between 2019 and 2020 in four centers compared with another group who underwent the procedure with fluoroscopy. RESULTS: Median age was 51.0 ± 15.9 years old; males were 77 (58.8%). Among the study population, 26 (19.8%) had a cardiomyopathy. The most frequent PVC origin was right ventricular outflow tract (55%) followed by the left ventricle (16%), LVOT and cusps (13.7%), and aortomitral continuity (5.3%). Acute suppression of PVC was achieved in 127 patients (96.9%). At 12 months, a complete success was documented in 109 patients (83.2%), a reduction in PVC burden in 18 patients (13.7%), and a failure was recorded in four patients (3.1%). Only two minor complications occurred (femoral hematoma and arteriovenous fistula conservatively treated). CONCLUSIONS: The PVC ablation with a "zero" fluoroscopy approach appears to be a safe procedure with no major complications and good rates of success and recurrence in our multicenter experience.


Catheter Ablation , Ventricular Premature Complexes , Humans , Catheter Ablation/methods , Male , Ventricular Premature Complexes/surgery , Fluoroscopy , Female , Middle Aged , Retrospective Studies , Treatment Outcome , Adult
12.
Europace ; 25(11)2023 11 02.
Article En | MEDLINE | ID: mdl-37889200

AIMS: Atrial fibrillation (AF) and chronic kidney disease (CKD) often coexist and share an increased risk of thrombo-embolism (TE). CKD concomitantly predisposes towards a pro-haemorrhagic state. Our aim was to evaluate the prognostic value of CKD in patients undergoing percutaneous left atrial appendage occlusion (LAAO). METHODS AND RESULTS: A total of 2124 consecutive AF patients undergoing LAAO were categorized into CKD stage 1+2 (n = 1089), CKD stage 3 (n = 796), CKD stage 4 (n = 170), and CKD stage 5 (n = 69) based on the estimated glomerular filtration rate at baseline. The primary endpoint included cardiovascular (CV) mortality, TE, and major bleeding. The expected annual TE and major bleeding risks were estimated based on the CHA2DS2-VASc and HAS-BLED scores. A non-significant higher incidence of major peri-procedural adverse events (1.7 vs. 2.3 vs. 4.1 vs. 4.3) was observed with worsening CKD (P = 0.14). The mean follow-up period was 13 ± 7 months (2226 patient-years). In comparison to CKD stage 1+2 as a reference, the incidence of the primary endpoint was significantly higher in CKD stage 3 (log-rank P-value = 0.04), CKD stage 4 (log-rank P-value = 0.01), and CKD stage 5 (log-rank P-value = 0.001). Left atrial appendage occlusion led to a TE risk reduction (RR) of 72, 66, 62, and 41% in each group. The relative RR of major bleeding was 58, 44, 51, and 52%, respectively. CONCLUSION: Patients with moderate-to-severe CKD had a higher incidence of the primary composite endpoint. The relative RR in the incidence of TE and major bleeding was consistent across CKD groups.


Atrial Appendage , Atrial Fibrillation , Renal Insufficiency, Chronic , Stroke , Humans , Atrial Appendage/surgery , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Prognosis , Treatment Outcome , Retrospective Studies , Hemorrhage/chemically induced , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/epidemiology , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Anticoagulants/adverse effects
13.
Cardiovasc Ultrasound ; 21(1): 20, 2023 Oct 26.
Article En | MEDLINE | ID: mdl-37880719

PURPOSE: Intra-cardiac echocardiography (ICE) has become an important tool for catheter ablation. Adoption of ICE imaging is still limited because of its prohibitively high cost. Our aim was to study the safety and feasibility of ICE catheters reprocessing and its environmental and financial impact. METHODS: This was a single center retrospective analysis of all consecutive electrophysiology procedures in which ICE catheters were used from 2015 to 2022. In total, 1128 patients were studied (70.6% male, mean age was 57.9 ± 13.2 years). The majority of procedures were related to atrial fibrillation ablation (84.6%). RESULTS: For the whole cohort, 57 new ICE catheters were used. Consequently one catheter could be used for 19.8 procedures. New catheters were only used when the image obtained by reused probes was not satisfactory. There were no cases of ICE probe steering mechanism malfunction, no procedure related infections and no allergic reactions that could be attributed to the resterilization process. In total, there was 8.6% of complications not related to ICE imaging. Financially, ICE probe reprocessing resulted with 90% cost reduction (> 2 millions of Euros savings for the studied period) and 95% waste reduction (639.5 kg less, mostly non degradable waste was produced). CONCLUSION: Our data suggests that ICE catheter reprocessing is feasible and safe. It seems that risk of infection is not increased. Significant economic and environmental savings could be achieved by ICE catheters reprocessing. Furthermore, ICE reprocessing could allow more extensive ICE usage resulting in safer procedures with a potential reduction of serious complications.


Atrial Fibrillation , Echocardiography , Humans , Male , Adult , Middle Aged , Aged , Female , Echocardiography/methods , Retrospective Studies , Feasibility Studies , Catheters , Electrophysiology , Treatment Outcome
14.
J Cardiovasc Electrophysiol ; 34(11): 2393-2397, 2023 Nov.
Article En | MEDLINE | ID: mdl-37792572

INTRODUCTION: Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed-field ablation (PFA) selectively targets the myocardium and seems associated with only negligible effects on the autonomic nervous system (ANS). However, little is known about the dynamic effects of PFA on the GP immediately after PVI. This study sought to investigate the degree and acute vagal modulation induced by the FarapulseTM PFA system during PVI compared with single-shot thermal ablation. METHODS: A total of 76 patients underwent first-time PVI with either FarapulseTM PFA (PFA group, n = 40) or cryoballoon ablation (thermal ablation group, n = 36) for paroxysmal atrial fibrillation (AF). The effect on the ANS in the two groups was assessed before and after PVI with extracardiac vagal stimulation (ECVS). To capture any transient effects of PFA on the ANS, in a subgroup of PFA patients ECVS was repeated at three predefined timepoints: (1) before PVI (T0); (2) immediately after PVI (T1); and (3) 10 min after the last energy application (T2). RESULTS: Despite similar baseline values, the vagal response induced by ECVS after PVI almost disappeared in the thermal ablation group but persisted in the PFA group (thermal group: 840 [706-1090] ms, p < .001 compared to baseline; PFA group: 11 466 [8720-12 293] ms, p = .70 compared to baseline). Intraprocedural vagal reactions (defined as RR increase >50%, transitory asystole, or atrioventricular block) occurred more frequently with PFA than thermal ablation (70% vs. 28%, p = .001). Moreover, heart rate 24 h post-PVI increased more with thermal ablation than with PFA (16.5 ± 9.0 vs. 2.6 ± 6.1 beats/min, p < .001). In the subgroup of PFA patients undergoing repeated ANS modulation assessment (n = 11), ECVS demonstrated that PFA determined a significant acute suppression of the vagal response immediately after PVI (p < .001 compared to baseline), which recovered almost completely within 10 min. CONCLUSION: PVI with the FarapulseTM PFA system is associated with only transitory and short-lasting vagal effects on the ANS which recover almost completely within a few minutes after ablation. The impact of this phenomenon on AF outcome needs to be further investigated.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Autonomic Nervous System/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Vagus Nerve/surgery , Heart Rate , Catheter Ablation/adverse effects , Treatment Outcome
15.
J Clin Med ; 12(19)2023 Sep 28.
Article En | MEDLINE | ID: mdl-37834900

Previous clinical studies on pulmonary vein isolation (PVI) with radiofrequency balloons (RFB) reported safe and effective procedures for a 20 s RF delivery via posterior electrodes. Recent recommendations from the manufacturer suggest reducing the application time to 15 s on the posterior wall (PW) when facing the esophagus region. Here, we retrospectively assess whether 15 s of RF delivery time on posterior electrodes is safe while still ensuring lesion metrics of sufficient quality. This retrospective study included 133 patients with paroxysmal and persistent atrial fibrillation who underwent PVI using an RFB (Heliostar, Biosense Webster, Inc., Irvine, CA, USA) at two European centers. The ablation protocol was set for an RF duration of 20 s/60 s for the posterior/anterior electrodes. A multielectrode temperature probe was systematically used. In the case of an esophageal temperature rise (ETR) above 42 °C (ETR+), an endoscopic evaluation was performed. All posterior electrode lesion metric dynamics (temperature (T) and impedance (Z)) were collected from the RFB generator and analyzed offline. In total, 2435 posterior electrode applications were analyzed. With an RF delivery of 19.8 (19.7-19.8) s, the median impedance drop was 18.4 (12.2-25.2) Ω, while the temperature rise was 11.1 (7.1-14.9) °C. Accordingly, impedance (84.6 (79.3-90.2) Ω) and temperature plateaus (38 (35.3-41.1) °C) were reached at 13.9 (10.6-16) s and 16.4 (12.6-18.5) s, respectively. Overall, 99.6% and 95.8% of electrodes reached 90% (16.6 Ω) and 95% (17.5 Ω) of their impedance drops within 15 s of RF delivery, while 97.2% and 92.8% achieved 90% (34.2 °C) and 95% (36.1 °C) of their temperature rise to reach the plateaus within 15 s of RF delivery. An ETR >42 °C occurred in 37 (30.1%) patients after 17.7 ± 2.3 s of RF delivery. In the ETR+ group, the impedance drop and temperature rise on the posterior electrodes were higher compared to patients where ETR was <42 °C. Two asymptomatic thermal esophageal injuries were observed. In conclusion, 15 s of RF delivery on the posterior electrodes provides a good balance between safety, with no esophageal temperature rise, and efficacy with high-profile lesion metrics.

16.
Am J Cardiol ; 207: 100-107, 2023 11 15.
Article En | MEDLINE | ID: mdl-37734298

Although pulmonary vein (PV) isolation (PVI) is the cornerstone for atrial fibrillation (AF) ablation, no data exist comparing PV anatomy between AF subtypes directly. We aimed to compare PV anatomic characteristics between paroxysmal (PAF) and persistent AF (PeAF) in a matched population using cardiac computed tomography (CCT). Fifty-eight PeAF patients (with CCT prior first AF ablation procedure, absence of valvular disease/previous cardiac intervention), and 58 age-, sex-, body surface area-matched PAF patients were evaluated for left atrial (LA) and PV anatomy: ostial area, ovality index (OVI), transverse/frontal angles. In PeAF vs PAF group, beside higher LA volume index (LAVI), PVs' ostial areas were significantly larger (between 64 - 101 mm2, P < 0.001 for all PVs; remaining valid after LAVI adjustment for left superior [LS], left inferior [LI], and right inferior [RI]PV); left PVs were less oval (0.7 - 0.11 OVI decrease, P =0.039 for LSPV; P = 0.012 for LIPV); LSPV (P = 0.019), LIPV (P < 0.001), RIPV (P = 0.029) were more posteriorly directed; whereas LSPV (P = 0.002), and right superior PV (P = 0.043) were more superiorly directed. Incidence of anatomic variations or early branching was not different. This study showed significant anatomical PV differences between patients with PeAF and PAF, in terms of PV orientation, ostial size and ovality. Anticipating such anatomical differences may aid in choosing the adequate catheter design and technology for PeAF ablation.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Radiography , Heart Atria/diagnostic imaging , Catheter Ablation/methods , Tomography , Treatment Outcome
17.
Article En | MEDLINE | ID: mdl-37756702

OBJECTIVES: Brugada syndrome is a life-threatening disease with an arrhythmogenic substrate located in the epicardium of right ventricle outflow tract. Therefore, the correct region identification is crucial for a successful ablation procedure. Various mapping techniques can be adopted to elaborate this issue, but they were all initially developed for endovascular use. METHODS: In this study, we analysed 21 consecutive hybrid video-assisted thoracoscopic ablation of Brugada syndrome, performed using different mapping systems to identify the ablation target and confirm the elimination of arrhythmogenic substrate; 35 maps have been analysed. RESULTS: Acute success of epicardial right ventricle outflow tract ablation has been achieved in 100% of procedures, no periprocedural complications have been observed; HD Grid catheter showed higher area identification speed and faster fractionated potentials visualization; Rhythmia system has demonstrated the best map density; Carto 3 system showed a significant advantage in patient preparation time, but mapping speed was reduced due to focal catheter use only. CONCLUSIONS: All tested electro anatomical mapping systems can be used for hybrid video-assisted thoracoscopic ablation with same clinical success; however, accuracy and efficacy of mapping systems are heterogenous and highly dependent on proper patient preparation, mapping system and physician skills.

18.
Europace ; 25(9)2023 08 02.
Article En | MEDLINE | ID: mdl-37671682

AIMS: Cryoballoon (CB) ablation is the mainstay of single-shot pulmonary vein isolation (PVI). A radiofrequency balloon (RFB) catheter has recently emerged as an alternative. However, these two technologies have not been compared. This study aims to evaluate the freedom from atrial tachyarrhythmias (ATas) at 1 year: procedural characteristics, efficacy, and safety of the novel RFB compared with CB for PVI in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: This prospective multi-centre study included consecutive patients with symptomatic drug-resistant paroxysmal AF who underwent PVI with RFB or CB between July 2021 and January 2022 from three European centres. A total of 375 consecutive patients were included, 125 in the RFB group and 250 in the CB. Both groups had comparable clinical characteristics. At 12.33 ± 4.91 months, ATas-free rates were 83.20% and 82.00% in the RFB and CB groups, respectively (P > 0.05). Compared with the CB group, the RFB group showed a shorter procedure time [59.91 (45.80-77.12) vs. 77.0 (35.13-122.71) min (P < 0.001)], dwell time [19.59 (14.41-30.24) vs. 27.03 (17.11-57.21) min (P = 0.04)], time to isolation, and thermal energy delivery in all pulmonary veins (P < 0.001). First-pass isolation was comparable. No major complications occurred in either group, with no stroke, atrio-oesophageal fistula, or permanent phrenic nerve injury. Transient phrenic nerve palsy occurred more frequently with CB than RFB (7.20% vs. 3.20%; P = 0.02). Oesophageal temperature rise occurred in 21 (16.8%) patients in the RFB group, and gastroscopy showed erythema in two of them with complete recovery after 30 days. CONCLUSIONS: The RFB appears to have a safety and efficacy profile similar to that of the CB for PVI. Shorter procedural times appear to be driven by shorter left atrial dwell and thermal delivery times.


Atrial Appendage , Atrial Fibrillation , Esophageal Fistula , Pulmonary Veins , Humans , Prospective Studies
19.
JACC Clin Electrophysiol ; 9(10): 2096-2105, 2023 10.
Article En | MEDLINE | ID: mdl-37565952

BACKGROUND: Patients with Brugada syndrome (BrS) have an increased risk of arrhythmias, including atrial tachyarrhythmias (ATas). OBJECTIVES: The purpose of this study was to assess underlying atrial cardiomyopathy in BrS and the effect of ajmaline (AJM) test on the atrium of BrS patients using electrocardiogram imaging (ECGI). METHODS: All consecutive patients diagnosed with BrS in a monocentric registry were screened and included if they met the following criteria: 1) BrS diagnosed following current recommendations; and 2) ECGI map performed before and after AJM with a standard protocol. Consecutive patients with no structural heart disease or BrS who had undergone ECGI were included as a control group. Genetic analysis for SCN5A was performed in all BrS patients. Total atrial conduction time (TACT) and local atrial conduction time (LACT) were calculated from atrial ECGI. The primary endpoint was ATas during follow-up. RESULTS: Forty-three consecutive BrS patients and 40 control patients were included. Both TACT and LACT were significantly prolonged in BrS patients compared with control patients. Furthermore, TACT and LACT were significantly higher after AJM administration and in BrS patients who were carriers of a pathogenic/likely pathogenic SCN5A variant. After a mean follow-up of 40.9 months, 6 patients experienced a first ATa occurrence (all in the BrS group, 13.9%). TACT was the only independent predictor of ATas with a cutoff of >138.5 ms (sensitivity 0.92 [95% CI: 0.83-0.98], specificity 0.70 [95% CI: 0.59-0.81]). CONCLUSIONS: ECGI-calculated TACT and LACT are significantly prolonged in BrS patients compared with control patients, and in BrS patients after AJM. This may be consistent with a concealed atrial cardiomyopathy in BrS.


Atrial Fibrillation , Brugada Syndrome , Cardiomyopathies , Humans , Brugada Syndrome/diagnostic imaging , Brugada Syndrome/genetics , Atrial Fibrillation/complications , Atrial Fibrillation/diagnostic imaging , Electrocardiography/methods , Ajmaline
20.
Cardiol Rev ; 2023 Jul 18.
Article En | MEDLINE | ID: mdl-37462720

This systematic review and meta-analysis aims to evaluate the predictive value of total atrial conduction time (TACT) assessed by tissue Doppler echocardiography (PA-TDI) in atrial fibrillation (AF) recurrence in patients following a rhythm-control strategy. A systematic approach following Preferred Reporting Items for Systematic Reviews and Meta-Analyses reporting guidelines was applied in electronic databases (Pubmed, Cochrane Library, and Web of Science), supplemented by scanning through studies' references. TACT was compared using a random-effects model and presented as a difference in means (MD). The primary endpoint was AF recurrence. Seven publications were included in this systematic review. The mean age of the patients ranged from 55 years to 72 years. Prolonged TACT was associated with AF recurrence [MD, 23.12 msec; 95% confidence interval (CI), 11.54-34.71; I2 = 95%]. Subgroup analysis showed that prolonged TACT was strongly associated with AF recurrence in persistent AF cohorts undergoing electrical cardioversion (MD, 26.56; 95% CI, 15.51-37.6; I2 = 86%), while in patients with paroxysmal AF (PAF) undergoing catheter ablation, the results were not statistically significant (MD, 11.48; 95% CI, -1.19 to 24.14; I2 = 90%). The summary area under the curve (sAUC) using a random-effects model was 0.89 (95% CI, 0.80-0.99). TACT is a valuable echocardiographic parameter that can predict AF recurrence in patients following a rhythm-control strategy. Protocol registration:https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42022353018.

...