Clin Chem Lab Med ; 62(5): 861-869, 2024 Apr 25.
Article En | MEDLINE | ID: mdl-37999449

OBJECTIVES: To evaluate the performance of the Academia-Government Collaboration for Laboratory Medicine Standardization in Korea (KR-STDZN) based on data from KR-STDZN proficiency testing (KR-STDZN-PT) for creatinine over eight years (2015-2022). METHODS: We used KR-STDZN-PT data of creatinine tests from 2015 to 2022. Acceptance of the participating institutions' test results was assessed by calculating the acceptance performance as absolute bias (absBias%), total coefficient of variance (tCV%), and total error (TE%) for each sample using six measurements from each institution and true values of each reference material. The test result was considered acceptable when absBias%, tCV%, and TE% were <5.10, <3.20, and <11.40 %, respectively. The proportion of acceptable institutions among all participating institutions in each round was defined as the acceptance rate. Improvements in absBias%, tCV%, and TE% were analyzed using creatinine concentration ranges in samples. RESULTS: The number of participating institutions increased from 2015 to 2017 but remained consistent since 2018. The acceptance rates for absBias% and TE% increased from 52.2 and 77.6 %, in 2015 and to 90.7 and 96.3 %, in 2022, respectively. The acceptance rate for tCV% remained in the 90 % range for eight years. When creatinine <3 mg/dL, mean absBias%, and mean TE% improved significantly in 2021-2022 compared to 2015-2016 (p<0.05). When creatinine >3 mg/dL, acceptance performance did not improve. Mean tCV% remained consistent annually regardless of creatinine concentration. No significant variations in test methods were observed. CONCLUSIONS: The collaboration between academia and the government improved creatinine testing quality. Nevertheless, KR-STDZN must be expanded and refined.


Academia , Laboratory Proficiency Testing , Humans , Creatinine , Reference Standards , Government
2.
Ann Lab Med ; 43(2): 167-173, 2023 03 01.
Article En | MEDLINE | ID: mdl-36281510

Background: Accurate measurement of glycated hemoglobin (HbA1c) is crucial for a diabetes diagnosis and subsequent patient management. The detection method and presence of variant Hb can interfere with HbA1c measurements. We evaluated the HbA1c-measuring performance of the DxC 700 AU (Beckman Coulter, Brea, CA, USA) immunoassay-based device in comparison with another immunoassay device and the reference method. Methods: A total of 120 normal and 14 variant Hb samples were analyzed using the Cobas c 513 (Roche Diagnostics, Mannheim, Germany) and DxC 700 AU analyzers. Variant Hb samples were also analyzed using the reference method, along with 20 normal samples. The accuracy, precision, linearity, and carryover were determined. Results: DxC 700 AU results strongly correlated with those of Cobas c 513 and exhibited accuracy in comparison with the reference method. The within-run, between-run, between-day, and total imprecision (%CV) values for the low- and high-concentration control materials were below 2%. The results of DxC 700 AU were linear over a wide HbA1c range (3.39%-18.30%). Although DxC 700 AU performed well in the presence of variant Hb, the HbA1c concentration was underestimated in the presence of fetal Hb. The possibility of interference from a high HbH proportion could not be ruled out. Conclusions: The overall analytical performance of DxC 700 AU was acceptable. The device is accurate, precise, and linear over a wide HbA1c concentration range. Although DxC 700 AU results highly correlated with those of Cobas c 513, caution should be exercised in cases of high HbF and HbH concentrations.


Hematologic Tests , Humans , Glycated Hemoglobin/analysis , Chromatography, High Pressure Liquid , Immunoassay/methods
...