Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Adv Sci (Weinh) ; 11(11): e2307148, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38161230

RESUMEN

Tolerance induction is critical for mitigating T cell-mediated inflammation. Treatments based on anti-CD3 monoclonal antibody (mAb) play a pivotal role in inducing such tolerance. Anti-CD3 mAb conjugated with dextran-coated magnetic nanoparticles (MNPs) may induce inflammatory tolerance is posited. MNPs conjugated with anti-CD3 mAb (Ab-MNPs) are characterized using transmission and scanning electron microscopy, and their distribution is assessed using a nanoparticle tracking analyzer. Compared to MNPs, 90% of Ab-MNPs increased in size from 54.7 ± 0.5 to 71.7 ± 2.7 nm. The in vitro and in vivo studies confirmed the therapeutic material as nontoxic and biocompatible. Mice are administered various dosages of Ab-MNPs before receiving concanavalin-A (ConA), an inflammation inducer. Preadministration of Ab-MNPs, as opposed to MNPs or anti-CD3 mAb alone, significantly reduced the serum levels of interferon-γ and interleukin-6 in ConA-treated mice. Additionally, the transdermal stamp patch as an effective delivery system for Ab-MNPs is validated. This study demonstrates the utility of the Ab-MNP complex in pathologies associated with T cell-mediated hyperinflammation, such as organ transplantation and COVID-19.


Asunto(s)
Inmunoconjugados , Nanopartículas de Magnetita , Animales , Ratones , Linfocitos T , Anticuerpos Monoclonales/uso terapéutico , Inmunidad Celular
2.
Adv Exp Med Biol ; 1395: 357-362, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36527662

RESUMEN

Previously, anti-CD3 antibodies delivered intravenously have been known for their negative side effects. The experimental conditions for optimal liquid production are derived from the Fc-directed conjugation of anti-CD3 foralumab antibodies and magnetic nanoparticles (Ab-MNPs). The anti-CD3 antibodies are prepared for conjugation with MNPs using SiteClick antibody labelling kits. The successful conjugation of the Ab-MNPs is confirmed using a transmission electron microscopy (TEM) image and an energy dispersive spectroscopy (EDS) analysis. The average values ​​of the moving speed of MNPs and Ab-MNPs in phosphate buffer saline (PBS) were + 3.16 pix/frame and + 6.70 pix/frame in the x-axis, respectively. This implies that MNPs with CD3 antibodies attached to the surface through biocompatible ligand functional groups has better fluidity in PBS. Afterwards, a non-clinical animal testing for the flow characteristics of Ab-MNPs inside a blood vessel is carried out to observe the effects of Ab-MNP delivery through intravenous injection.


Asunto(s)
Nanopartículas de Magnetita , Animales , Nanopartículas de Magnetita/química , Magnetismo , Microscopía Electrónica de Transmisión , Fenómenos Físicos , Anticuerpos Monoclonales
3.
Heliyon ; 8(10): e11232, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36340004

RESUMEN

The experimental autoimmune encephalomyelitis mouse model is the most commonly used animal model, and it best represents multiple sclerosis. Grancalcin (GCA) was discovered to be upregulated in EAE mice. GCA comprises 220 amino acids that have been assigned the UniprotKB ID Q8VC88. It is a calcium-binding protein that helps neutrophils adhere to fibronectin and the formation of focal adhesions. However, the protein data bank does not contain the crystal structure of mouse GCA. The current study aims to analyze the structural and physicochemical properties of GCA. Mouse GCA showed a high percentage identity (87%) with the crystal structure of des (1-52) grancalcin with bound calcium (chain A) from Homo sapiens identified by its PDB id 1k94_A. Using the SWISS-MODEL server, we used 1k94_A as a template protein to model the mouse GCA protein. Compared to the template structure 1K94, three potential binding sites for calcium-binding have been proposed, ranging from 13 to 20, 80 to 91, and 109 to 120 amino acids. On an i5 personal computer with 8GB of RAM, GROMACS 2020.1 was utilized to run a 100 ns molecular dynamics (MD) simulation. RMSD, Rg, and RMSF analysis of an MD simulation trajectory indicate a stable and compact state throughout the simulation period of modeled proteins. We found that GCA is primarily alpha helical (Class 1), with eight alpha helices. The essential dynamics analysis captures PCA and SASA, culminating in the biological motions that correspond to the last 1000 frames. These findings will aid the development of potential inhibitors as well as the determination of binding pockets and residues for drug-like molecules.

4.
J Acupunct Meridian Stud ; 15(1): 37-42, 2022 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-35770572

RESUMEN

Background: The primo vascular system can be viewed as a circulatory system that plays a therapeutic function in regenerating the body tissue. The anti-CD3 monoclonal antibody was used as an immunotherapeutic agent to treat the novel coronavirus infection (COVID-19). Objectives: In this study, we observed the effect of injecting lymph nodes with Foralumab, an anti- human CD3 epsilon therapeutic monoclonal antibody, on primo vessels. Methods: The structure and atomic stoichiometry of the antibody were determined by transmission electron microscopy and energy dispersive spectroscopy. Alcian blue dying solution was injected into the lymph nodes of the abdominal vena cava of rabbits, and the solution further flowed into the lymph vessels. Results: A primo vessel with primo nodes stained with Alcian blue was clearly visible in the lymph vessel. By injecting Foralumab into lymph nodes of rabbits with lipopolysaccharide-induced inflammation, the floating primo vessel in the lymph vessel appeared thicker and was distinctly visible. Conclusion: The observation of the primo vessel post-treated with Foralumab in the inflamed lymphatic system suggests the possibility of a functional role of the primo vascular circulatory system in pathophysiological conditions.


Asunto(s)
COVID-19 , Vasos Linfáticos , Meridianos , Azul Alcián/química , Animales , Anticuerpos Monoclonales/análisis , Inflamación , Lipopolisacáridos/efectos adversos , Lipopolisacáridos/análisis , Vasos Linfáticos/química , Conejos , Coloración y Etiquetado
5.
Adv Exp Med Biol ; 1269: 373-377, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33966245

RESUMEN

In recent years, research has been intensively carried out on the applicability of magnetic beads (MBs) and magnetic nanoparticles coupled to biological objects such as red blood cells (RBCs). The magnetoresistance (MR) of a solution of RBCs and MBs (RBCs+MBs) was evaluated when MBs migrated in the presence or absence of an external magnetic field. The pattern of distribution of the MBs, which were homogeneously suspended in deionized distilled water, varied depending on the magnitude of the external magnetic field applied between the Cu electrodes connected to the two terminals. As the magnitude of the external magnetic field is increased or decreased, MBs are split on both sides and evenly mixed, respectively. The ratios (ΔMR/MR) versus an external magnetic field for the solutions of only MBs and a mixed RBCs+MBs were -33.4% and -27.4% at ±30 Oe and ±46 Oe of coercive fields, respectively. These results show that a solution of RBCs+MBs can act like a high-resolution biosensor that detects the oxygenation state of RBCs.


Asunto(s)
Técnicas Biosensibles , Separación Inmunomagnética , Electrodos , Eritrocitos , Campos Magnéticos
6.
Adv Exp Med Biol ; 1269: 387-391, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33966247

RESUMEN

The gene expression of Prox-1 and Hif-1a for the isolated primo vessels (PVs) and composite lymphatic vessels (LVs) containing PVs (LVs + PVs) was investigated by RNA-sequencing (Seq) and quantitative polymerase chain reaction (qRT-PCR) analysis. RNA-Seq on the passed 10 samples on RNA-QC for two experimental groups with PVs and PVs + LVs proceeded to the library construction stage automatically and analyzed differentially expressed genes (DEGs). From the real-time qRT-PCR analysis data, we found the marker genes of Prox-1 and Hif-1a were enriched and decreased in an isolated PVs compared to LVs, respectively. Based on mRNA transcriptional data, Prox-1 and Hif-1a were increased and decreased in PVs compared to LVs + PVs under lipopolysaccharide (LPS) treatment and relieved by acupuncture electric stimulation (AES), respectively. This finding indicates that high and low levels of Prox-1 and Hif-1a may be involved in the function of PVs and that pathophysiological and physiological condition could progress into inflamed lymphatic endothelial cells expanding the PV within the LV.


Asunto(s)
Células Endoteliales , Vasos Linfáticos , Animales , Expresión Génica , Proteínas de Homeodominio , Subunidad alfa del Factor 1 Inducible por Hipoxia , Lipopolisacáridos , Conejos , Análisis de Secuencia de ARN
7.
Adv Exp Med Biol ; 1232: 393-399, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31893436

RESUMEN

Although the existence of the primo vasculature system has been shown in many species, including mice, rats, rabbits and humans, the biological role of this system, including expression of genes and proteins, has not yet been investigated. Especially the transcriptional action by mRNA, which is required for biological action, needs to be studied in primo vasculature biology. Differentially expressed genes in both isolated primo vessels and lymphatic vessels of rabbits were analyzed by RNA sequencing experiments. Primer efficiency and RNA purity of the primo vessels under lipopolysaccharides were confirmed prior to performing real-time qRT-PCR analysis following RNA extraction. We demonstrated that FLT4 was enriched in primo vessels and that several genes, including HSPH1 and EPHB2, were highly expressed in primo vessels compared with lymphatic vessels. Our data show that almost all genes, except HSPA4, were increased or sustained in isolated primo vessels compared with lymphatic vessels (FLT4 2.58 fold, HSPH1 1.83 fold, EPHB2 1.52 fold; whereas HSPA4 decreased 0.50 fold), suggesting primo vessels as a central regulator in diverse physiology. This implies that FLT4, HSPH1, and EPHB2 in high amounts may be involved in the functional activity of primo vessels. Our experimental data show that several genes are highly enriched in primo vessels in the lymphatic vessels of the rabbit.


Asunto(s)
Regulación de la Expresión Génica , Vasos Linfáticos , RNA-Seq , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Animales , Proteínas del Choque Térmico HSP110/genética , Vasos Linfáticos/metabolismo , ARN Mensajero/genética , Conejos , Receptor EphB2/genética , Análisis de Secuencia de ARN , Receptor 3 de Factores de Crecimiento Endotelial Vascular/genética
8.
J Acupunct Meridian Stud ; 12(1): 3-10, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29626523

RESUMEN

It is known that the primo vascular system (PVS) includes the primo nodes and vessels. However, the relevant genes in the PVS system for both pathologic and physiologic condition are poorly understood. Here, we first examined the gene expression in primo vessels (PVs) floating in lymphatic endothelium by isolation of PVS and lymphatic vessels (LVs) containing PVS. To investigate therapeutic effects, both PVs and LVs containing PVS were isolated after lipopolysaccharide injection and acupuncture electric stimulation at two acupoints Joksamni (ST36) and Hapgok (LI04) following lipopolysaccharide injection. We used reverse transcriptase-polymerase chain reaction to examine expression of lymphatic endothelial cell markers and inflammatory related genes. We found that lymphatic endothelial cell markers such as fms-related tyrosine kinase 4 (Flt4), lymphatic vessel endothelial receptor (Lyve-1), prospero homeobox protein 1 (Prox-1), and podoplanin (Pdpn) were highly expressed in PV compared to that of lymphatic endothelium, suggesting pivotal roles of PV in LV under inflammation. Furthermore, lymphatic-related genes including metal-response element-binding transcription factor 2 (Mtf2), hypoxia inducible factor (Hif1a), angiotensin II type 1 receptor (Agtr1), and angiotensin II type 2 receptor (Agtr2) were also overall increased in PV, and remarkably increased and these genes except peroxisome proliferator-activated receptor gamma (Pparg) after acupuncture electric stimulation in two acupoints implying central role of PV by gene activation.


Asunto(s)
Electroacupuntura , Endotelio Linfático , Endotelio Linfático/química , Endotelio Linfático/metabolismo , Endotelio Linfático/efectos de la radiación , Expresión Génica/efectos de la radiación , Humanos , Lipopolisacáridos , PPAR gamma/genética , PPAR gamma/metabolismo , Receptor 3 de Factores de Crecimiento Endotelial Vascular/genética , Receptor 3 de Factores de Crecimiento Endotelial Vascular/metabolismo
9.
J Acupunct Meridian Stud ; 12(1): 11-19, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30394350

RESUMEN

For the connectome of primo vascular system, some long-type primo vessels dyed with Alcian blue injected into inguinal nodes, abdominal node, and axially nodes were visualized, which passed over around the vena cava of the rabbit. The Alcian blue dye revealed primo vessels and colored blue in the rabbit lymph vessels. The length of long-type primo vessels was 18 cm on average, of which diameters were about 20-30 µm, and the lymph vessels had diameters of 100-150 µm. Three different tissues of pure primo vessel, mixed primo + lymph vessel, and only lymph vessel were made to undergo RNA-Seq analysis by next-generation sequencing. We also analyzed differentially expressed genes (DEGs) from the RNA-Seq data, in which 30 genes of the primo vessels, primo + lymph vessels, and lymph vessels were selected for primo marker candidates. From the plot of DEG analysis, 10 genes had remarkably different expression pattern on the Group 1 (primo vessel) vs Group 3 (lymph vessel). With Fragments Per Kilobase of exon per Million the cutoff p-value for each gene was < 0.05. Fragments Per Kilobase of exon per Million of the 10 genes such as IGHM, HLA-DRA, HIST1H41, LPL, CD36, SRGN, DGAT2, SNCG, CD48, and GPD1 for primo vessels compared with those of lymph vessels increased twice or thrice. These results suggest that the selected genes could be used for the specific marker to construct primo connectome of circuit system in the rabbit.


Asunto(s)
Perfilación de la Expresión Génica/métodos , Vasos Linfáticos/metabolismo , ARN Mensajero/análisis , Análisis de Secuencia de ARN/métodos , Animales , Biomarcadores/análisis , Biomarcadores/metabolismo , Vasos Linfáticos/química , ARN Mensajero/genética , ARN Mensajero/metabolismo , Conejos
10.
Adv Exp Med Biol ; 1072: 345-349, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30178369

RESUMEN

A giant magnetoresistance-spin valve (GMR-SV) having highly sensitive magnetic properties was prepared with a multilayer soft ferromagnetic/non-magnetic/pinned ferromagnetic/anti-ferromagnetic iridium manganese (IrMn) top layer (NiFe/CoFe/Cu/CoFe/IrMn) structure. Micron-sized magnetic beads (MBs) with a diameter of 1 µm immersed in a solution containing 50 mg of Co-Si-OH/ml were attached to red blood cells (RBCs) having the very low magnetization of hemoglobin (HEM) to detect a deoxidized RBC combined with MBs (RBC+MBs). The RBC+MB combinations can be captured on a single-turn µ-coil that maintains a magnetic field large enough to detect the MBs attached to the RBC. When the RBC+MBs passes through a PR µ-channel with a width of 10 µm, its stopping and starting are controlled by the electrical AC input signal applied to the single-turn µ-coil. The RBC+MBs combinations captured above the µ-device of the GMR-SV change the output signal and thus, can be used for detection. This observation implies that this device can be used as a biosensor to analyze the coupling force between the HEM and the MBs for RBCs with deformed membranes passing through a narrow capillary.


Asunto(s)
Técnicas Biosensibles/métodos , Eritrocitos/citología , Separación Inmunomagnética/métodos , Magnetismo/métodos , Humanos
11.
Sensors (Basel) ; 11(2): 1784-93, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22319381

RESUMEN

To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.


Asunto(s)
Arterias/fisiología , Determinación de la Presión Sanguínea/instrumentación , Presión Sanguínea/fisiología , Magnetismo/instrumentación , Pulso Arterial/instrumentación , Algoritmos , Electrónica , Humanos , Radio (Anatomía)/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...