Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 4 de 4
1.
Microbiol Spectr ; 11(6): e0167323, 2023 Dec 12.
Article En | MEDLINE | ID: mdl-37800931

IMPORTANCE: This manuscript describes an occurrence of false-positive GM tests in patients receiving TPN products from a manufacturer who had recently changed the supplier of the glucose component. We describe the clinical presentation of nine false-positive cases and the results of serologic and microbiological investigations of the TPN products suspected of contamination with GM. Attempts to detect GM in parenteral nutrition products were made since the detection of GM in sodium gluconate-containing solutions in 2007, but none of them identified the source of elevated GM indexes in TPN products. However, the present study demonstrated that the glucose component of the TPN products contained a high level of GM antigen, which caused false-positive GM assay results. The source of GM was glucoamylase, which was derived from A. niger in the manufacturing process. Physicians and clinical microbiology laboratories should be aware of this issue to improve interpretation and patient care.


Aspergillus , Mannans , Humans , False Positive Reactions , Immunoassay , Parenteral Nutrition, Total , Antigens, Fungal
2.
Diagn Microbiol Infect Dis ; 107(4): 116051, 2023 Dec.
Article En | MEDLINE | ID: mdl-37708643

We compared the performance of the STANDARD F and SD BIOLINE stool antigen tests in 335 patients. The performance of STANDARD F (sensitivity: 95.6%; specificity: 94%) was highly comparable to that of SD BIOLINE (sensitivity: 92.6%; specificity: 93.5%), suggesting that STANDARD F is useful for the detection of Helicobacter pylori infection.


Helicobacter Infections , Helicobacter pylori , Humans , Helicobacter Infections/diagnosis , Sensitivity and Specificity , Antigens, Bacterial , Immunologic Tests
4.
Molecules ; 26(11)2021 Jun 07.
Article En | MEDLINE | ID: mdl-34200415

Homovanillic acid (HVA) and vanillylmandelic acid (VMA) are end-stage metabolites of catecholamine and are clinical biomarkers for the diagnosis of neuroblastoma. For the first time in Korea, we implemented and validated a liquid chromatography tandem mass spectrometry (LC-MS/MS) assay to measure urinary concentrations of HVA and VMA according to Clinical and Laboratory Standards Institute guidelines. Our LC-MS/MS assay with minimal sample preparation was validated for linearity, lower limit of detection (LOD), lower limit of quantification (LLOQ), precision, accuracy, extraction recovery, carryover, matrix effect, and method comparison. A total of 1209 measurements was performed to measure HVA and VMA in spot urine between October 2019 and September 2020. The relationship between the two urinary markers, HVA and VMA, was analyzed and exhibited high agreement (89.1% agreement, kappa's k = 0.6) and a strong correlation (Pearson's r = 0.73). To our knowledge, this is the first study to utilize LC-MS/MS for simultaneous quantitation of spot urinary HVA and VMA and analyze the clinical application of both markers on a large scale for neuroblastoma patients.


Homovanillic Acid/chemistry , Neuroblastoma/diagnosis , Neuroblastoma/metabolism , Vanilmandelic Acid/chemistry , Biological Assay/methods , Biomarkers/metabolism , Child , Child, Preschool , Chromatography, Liquid/methods , Female , Follow-Up Studies , Humans , Infant , Infant, Newborn , Limit of Detection , Male , Republic of Korea , Tandem Mass Spectrometry/methods
...