Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Int Ophthalmol ; 44(1): 186, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38643220

RESUMEN

PURPOSE: This study introduces the Order of Magnitude (OM), a cost-effective, indigenous, virtual reality-based visual field analyzer designed for detecting glaucomatous visual field loss. METHODS: The OM test employs a two-step supra-thresholding algorithm utilizing stimuli of 0.43°diameter (equivalent to Goldmann size III) at low and high thresholds. A comparative analysis was conducted against the Humphrey visual field (HVF) test, considered the gold standard in clinical practice. Participants, including those with glaucoma and normal individuals, underwent comprehensive eye examinations alongside the OM and HVF tests between April and October 2019. Diagnostic sensitivity and specificity of the OM test were assessed against clinical diagnoses made by specialists. RESULTS: We studied 157 eyes (74 glaucomatous, 83 control) of 152 participants. Results demonstrated a high level of reliability for both OM and HVF tests, with no significant difference observed (P = 0.19, Chi-square test). The sensitivity and specificity of the OM test were found to be 93% (95% CI 86-100%) and 83% (95% CI 72.4-93%), respectively, while the HVF test showed sensitivity and specificity of 98% (95% CI 93.9-100%) and 83% (95% CI 73.9-92.8%), respectively. CONCLUSION: These findings suggest that the OM test is non-inferior to the reference standard HVF test in identifying glaucomatous visual field loss.


Asunto(s)
Glaucoma , Campos Visuales , Humanos , Reproducibilidad de los Resultados , Glaucoma/diagnóstico , Pruebas del Campo Visual/métodos , Trastornos de la Visión/diagnóstico , Sensibilidad y Especificidad
2.
Eye (Lond) ; 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37968514

RESUMEN

BACKGROUND: To report 15-year incidence rate of primary open angle glaucoma (POAG) in the Andhra Pradesh Eye Disease Study (APEDS). METHODS: A population-based longitudinal study was carried out at three rural study sites. Phakic participants aged ≥40 years who participated at baseline (APEDS I) and the mean 15-year follow-up visit (APEDS III) were included. A comprehensive ophthalmic examination was performed on all participants. Mean intraocular pressure (IOP) was average of IOPs of right and left eyes. The definition of glaucoma was based on the International Society of Geographical and Epidemiological Ophthalmology (ISGEO) classification. The main outcome measure was incidence of POAG during the follow-up period in participants without glaucoma or suspicion of glaucoma at baseline. RESULTS: Data from the available and eligible participants from the original cohort (1241/2790; 44.4%) were analysed. The mean age (standard deviation) of participants at baseline was 50.2 (8.1) years; 580 (46.7%) were men. Thirty-six participants developed POAG [bilateral in 17 (47.2%)] over 15 years. The incidence rate of POAG per 100-person years (95% confidence interval) was 2.83 (2.6, 3.08). Compared to baseline, the reduction in mean IOP [median (range) mm Hg] was -0.75 (-7.5, 9) in participants with incident POAG and -2.5 (-14.5, 14.5) in those without. The inter-visit difference in mean IOP was a significant risk factor on logistic regression analysis. CONCLUSION: We report the long-term incidence of POAG in rural India. A longitudinal change in IOP, specifically a less pronounced reduction in IOP with increasing age, was a novel risk factor.

3.
Eye (Lond) ; 37(8): 1704-1710, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36085361

RESUMEN

BACKGROUND: To report the 15-year incidence rate of pseudo-exfoliation (PXF),  PXF glaucoma and regional variation among rural participants in the Andhra Pradesh Eye Disease Study (APEDS) III. METHODS: This population-based longitudinal study was carried out at three rural study sites. Individuals of all ages who participated at baseline with a mean 15-year follow-up visit were included. Detailed Comprehensive ophthalmic examination was performed on all participants. The main outcome measure was development of PXF during the follow-up period in participants who were phakic in one or both eyes without PXF at baseline. RESULTS: Among 5395 participants, 5108 (94.6%) met the inclusion criteria. There were 93 (1.82%; 95% confidence interval (CI), 1.47-2.22) cases of incident PXF. Their median baseline age (1st, 3rd quartiles) was 51 (44, 59) years and the male: female ratio was 1.3:1. There was no case of incident PXF in participants aged <30 years at baseline. The incidence rate per 100 person years (95% CI) among all ages and those aged ≥30 years at baseline was 1.73 (1.64-1.82) and 3.73 (3.53-3.93), respectively. PXF material was located on iris as well as anterior surface of lens and it was often bilateral. Participants living in two study sites and increasing age were associated with the incidence of PXF. The 15-year incidence of PXF glaucoma (95% CI) in participants ≥30 years of age at baseline was 0.33% (0.14-0.66). CONCLUSION: There is significant regional variation in incidence of PXF in south India which warrants further investigation.


Asunto(s)
Síndrome de Exfoliación , Glaucoma , Humanos , Masculino , Femenino , Adulto , Síndrome de Exfoliación/complicaciones , Incidencia , Presión Intraocular , Estudios Longitudinales , Glaucoma/diagnóstico , Glaucoma/epidemiología , Glaucoma/complicaciones
4.
Semin Ophthalmol ; 38(1): 44-51, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35989652

RESUMEN

BACKGROUND: Glaucoma is one of the leading causes of irreversible blindness across the world. Early detection is important to minimize the loss of visual function. The diagnostic tools, optical coherence tomography (OCT) and standard automated perimetry (SAP) form the keystones of the diagnosis and monitoring of the condition. However, the ability of these tools to diagnose early forms of glaucoma is limited. Adaptive optics (AO) is a technology that could help to overcome this limitation. AO technology can detect slightest changes occurring at the cellular level by compensating for ocular aberrations. METHODS: We searched PubMed for publications between 2002 and 2019 on adaptive optics in Ophthalmology. The key words were adaptive optics, lamina cribrosa, retinal nerve fiber layer defects, scanning laser ophthalmoscope and OCT. RESULTS: Out of 38 publications, 17 original articles or case series with relevance to glaucoma, and written in English were selected and reviewed. CONCLUSIONS: The AO technology, combined with various platforms such as fundus photography, scanning laser ophthalmoscopy and OCT, has been used in glaucoma patients to study the lamina cribrosa, retinal nerve fiber layer (RNFL), retinal photoreceptors as well as ocular circulation in minute detail. Imaging the subtle changes in morphology and reflectivity of RNFL at the preclinical stage may lead to early detection of glaucoma. Longitudinal monitoring of RNFL alterations in glaucoma patients is possible. At present, the technology is expensive with limited availability, and has several limitations.


Asunto(s)
Glaucoma , Enfermedades de la Retina , Humanos , Glaucoma/diagnóstico , Retina , Pruebas del Campo Visual/métodos , Oftalmoscopía/métodos , Tomografía de Coherencia Óptica/métodos , Diagnóstico Precoz , Presión Intraocular
5.
Indian J Ophthalmol ; 70(8): 2877-2882, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35918935

RESUMEN

Purpose: To compare image characteristics of retinal nerve fiber layer (RNFL) between glaucoma patients and healthy controls using adaptive optics scanning laser ophthalmoscopy (AOSLO). Methods: This was a cross-sectional pilot study with two groups: a glaucoma group with patients with moderate or severe glaucoma as per the Hodapp-Parrish-Anderson classification system and a control group with healthy individuals. The optic nerve damage in moderate glaucoma was predominantly located in only one hemisphere; the other hemisphere was un- or minimally affected on optical coherence tomography and automated perimetry and is referred to as early glaucoma. The structure of RNFL bundles and gain (%) in RNFL images with mean pixel values between 15 and 35 were analyzed. Imaging was performed one degree away from the optic disc margin at two and four cardinal clock positions in the glaucoma and control groups, respectively. The field of view was 1.3° at 2.3 µ resolution. We studied one eye per participant. Results: There were 11 glaucoma patients and 7 healthy controls. Imaging was successful at 88% of the locations in controls and early glaucoma; the reflectivity differed significantly (0.51 and 0.56, respectively, P < 0.001) but not the structure of RNFL bundles (Cohen's Kappa 0.11) between them. In patients with moderate and severe glaucoma, imaging was successful only at 46% of the locations; RNFL bundles were not discernible, and RNFL reflectivity did not differ from those with early glaucoma (P < 0.11). Conclusion: The recorded gain (%) of RNFL images obtained using AOSLO could be an objective indicator of early glaucoma.


Asunto(s)
Glaucoma , Fibras Nerviosas , Estudios Transversales , Diagnóstico Precoz , Glaucoma/diagnóstico , Humanos , Rayos Láser , Oftalmoscopía/métodos , Proyectos Piloto , Tomografía de Coherencia Óptica/métodos
6.
Br J Ophthalmol ; 106(4): 480-484, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-33293270

RESUMEN

PURPOSE: To validate estimation of Goldmann applanation tonometer (GAT) intraocular pressure (IOP) from scleral Schiotz IOP measurements using a regression model in normal eyes and eyes with type-1 keratoprostheses. METHODS: In this prospective cross-sectional study, cohort-1 had 253 normal anterior segment eyes, and cohort-2 had 100 eyes with type-1 keratoprostheses. Scleral Schiotz IOP measurements were used (in a non-linear model) to predict GAT IOP values for these eyes. Accuracy of predicted GAT IOP values was assessed using actual GAT IOP values for normal eyes, while for type-1 keratoprosthetic eyes, finger tension (FT) IOP assessments by an experienced glaucoma specialist were used. Primary outcome was agreement between FT IOP (assessed by an experienced glaucoma specialist) and predicted GAT IOP-derived clusters. RESULTS: The actual values of GAT IOP measurements in normal eyes (n=253; mean age ±SD, 51.35±15.56 years) ranged between 6 mm Hg and 62 mm Hg (mean=22±10.05 mm Hg). Estimated and actual GAT IOP values for normal eyes were very similar (mean difference=0.05 mm Hg with limits of agreement: -5.39 to 5.5 by Bland-Altman plot). Of the 100 eyes with type-1 keratoprostheses, 68 were classified as having digitally normal IOP, 28 as borderline and 4 as high. The agreement between classification by FT assessment and model-predicted GAT IOP values was substantial (Kappa=0.81, 95% CI 0.69 to 0.93). The accuracy of the model in assessing IOP was found to be 91% (95% CI 0.84 to 0.96). CONCLUSION: Scleral Schiotz IOP values along with our predictive model can be an alternative objective method to FT IOP in assessing IOP in eyes with type-1 keratoprostheses.


Asunto(s)
Glaucoma , Presión Intraocular , Niño , Córnea , Estudios Transversales , Humanos , Estudios Prospectivos , Reproducibilidad de los Resultados , Tonometría Ocular/métodos
7.
Cornea ; 41(2): 159-164, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34351729

RESUMEN

PURPOSE: To evaluate the long-term outcomes of Descemet-stripping endothelial keratoplasty (DSEK) in 52 eyes with iridocorneal endothelial (ICE) syndrome. METHODS: Retrospective study of 52 eyes of 52 patients who were diagnosed with ICE syndrome and underwent DSEK between January 2010 and December 2019 with a follow-up of at least 6 months. RESULTS: The mean age was 48.8 ± 10.8 years. Female patients (n = 33) constituted 63.5%. The median duration of follow-up was 2.4 years (range, 0.5-9.1 yrs). The mean best-corrected visual acuity improved significantly after surgery and remained stable (∼20/50) through 5 years. The mean endothelial cell loss was 28%, 37.9%, 43.6%, and 56.9% at 6 months and at 1, 2, and 3 years, respectively. Graft rejection was noted in 5 eyes (9.6%). Postoperatively, increased intraocular pressure (IOP) was seen in 17 eyes (32.7%), and 10 eyes (19.2%) underwent glaucoma surgeries. Fourteen eyes (26.9%) had secondary graft failures. The estimates of graft success were 93.6% ± 3.6% at 1 year, 85.6% ± 5.5% at 2 years, 79.3% ± 6.7% at 3 years, 69.0% ± 8.9% at 4 years, and 59.1% ± 11.9% at 5 years. Postoperative increased IOP was found to be the only significant (P = 0.05) risk factor (hazard ratio 8.92) associated with graft failure. The clinical variant of ICE syndrome did not seem to influence the graft survival (P = 0.68). CONCLUSIONS: In this study, DSEK had a success rate of ∼60% at 5 years. Increased IOP post-DSEK is a significant risk factor for graft failure. Graft survival is not affected by the clinical variant of ICE syndrome.


Asunto(s)
Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Rechazo de Injerto/epidemiología , Síndrome Endotelial Iridocorneal/cirugía , Agudeza Visual , Adulto , Anciano , Femenino , Estudios de Seguimiento , Supervivencia de Injerto , Humanos , Incidencia , India/epidemiología , Síndrome Endotelial Iridocorneal/diagnóstico , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo
8.
J Glaucoma ; 30(2): 148-156, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33955944

RESUMEN

PRECIS: We describe standardization and simplification of classic trabeculectomy combined with manual small incision cataract surgery (MSICS) to effectively manage the 2 leading and often coexisting causes of blindness and vision impairment in resource-constrained areas. PURPOSE: The purpose of this study was to describe modifications to trabeculectomy combined with MSICS and report on the outcomes of this technique. The modifications consist of standardization and simplification of the surgical steps. METHODS: Data obtained from adult patients who underwent described surgical technique at rural eye care centers across 3 Indian states between January 2018 and May 2019 were analyzed retrospectively. Complete success was intraocular pressure between 6 and 18 mm Hg without supplementary medication. Qualified success allowed up to 3 topical medication(s). Data are presented as median (first and third quartiles). RESULTS: We analyzed data of 70 eyes of 70 patients. Ophthalmology fellows performed 27 (38.5%) surgeries, whereas an experienced glaucoma specialist performed 43 (61.4%) surgeries. Patients were 63 (56, 67) years old. The preoperative intraocular pressure was 20 (16, 26) mm Hg on treatment with 3 (2, 3) antiglaucoma medications. Glaucoma was advanced by optic disc structural criteria in 58 (82.8%) eyes. Intraoperative mitomycin C was used in 5 (7.1%) eyes. Follow-up was 12.5 (6, 18) months. At 1 year, complete success (95% confidence interval) achieved was 55% (41-67), whereas qualified success was 83% (68-92) with 0 (0, 1) topical medications. The complete and qualified success rates did not differ between ophthalmology fellows and the glaucoma specialist (P=0.75 and 0.44, respectively). CONCLUSIONS: We present a straightforward, yet effective technique of combined cataract and glaucoma surgery. The technique has a potential for wider applicability, especially in the underserved regions of the world.


Asunto(s)
Catarata , Oftalmología , Trabeculectomía , Adulto , Anciano , Estudios de Seguimiento , Humanos , Presión Intraocular , Mitomicina , Estudios Retrospectivos , Resultado del Tratamiento
9.
Ophthalmol Glaucoma ; 4(3): 238-243, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34030826

RESUMEN

PURPOSE: To study the agreement between the Icare ic200 (ICare Finland Oy, Helsinki, Finland) and the Goldmann Applanation Tonometer (GAT) in the measurement of intraocular pressure (IOP) in adult eyes. DESIGN: Noninterventional, cross-sectional study. PARTICIPANTS: A total of 156 eyes of 156 adult participants with clear corneas were included. METHODS: The IOP measurements were obtained with the Icare ic200 by 1 observer followed by GAT readings by a second masked observer. The central corneal thickness (CCT) and biometry of all subjects were recorded. MAIN OUTCOME MEASURES: The agreement between Icare ic200 and GAT was measured using the Bland-Altman plot. RESULTS: The mean age ± standard deviation of subjects was 55.3 ± 13.7 years. The GAT IOP ranged from 6 to 50 mmHg with a mean IOP of 19.5 ± 8.8 mmHg. The Icare ic200 IOP ranged from 7.4 to 50 mmHg with a mean IOP of 20.8 ± 9.3 mmHg. The mean difference between the IOP measurement of GAT and Icare ic200 was -1.27 mmHg with the 95% limits of agreement (LoA) ranging from -3.4 to 0.9 mmHg for all ranges of IOP. The mean difference (95% LoA) between the IOP measurement of GAT and Icare ic200 was -1 mmHg (-3 to 1 mmHg) and -1.8 mmHg (-4 to 0.2 mmHg) for a GAT IOP ≤21 mmHg and >21 mmHg, respectively. The CCT, axial length, age, and gender did not significantly affect the difference in measurement of IOP between the 2 tonometers. However, for every 1-mmHg increase in GAT IOP, the difference between the 2 tonometers increased by 0.04 mmHg (P < 0.001). CONCLUSIONS: In our study, the Icare ic200 overestimated the IOP. The overestimation increased as the baseline IOP increased. The agreement between the IOP measurement by GAT and Icare ic200 was <2 mmHg at all ranges of IOP. The narrow LoA between the tonometers for an IOP <21 mmHg makes it a useful alternative to GAT in this pressure range.


Asunto(s)
Presión Intraocular , Tonometría Ocular , Adulto , Córnea , Estudios Transversales , Humanos , Reproducibilidad de los Resultados
10.
Semin Ophthalmol ; 36(7): 561-568, 2021 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-33750265

RESUMEN

PURPOSE: To investigate endothelial imaging patterns in ICE syndrome and correlate these with the observed clinical features in the affected eye. METHODS: Of the 70 patients of ICE syndrome referred from the glaucoma clinic between 2017 and 18, 17 patients had a clear cornea for reliable endothelial imaging were included in the study. RESULTS: Mean age was 47(range 29-63) years; 9 males and 8 females. The right eye was involved in 10 and left eye in 7 patients. Mean best corrected visual acuity was 20/30 (20/20-20/80) in the affected eye. All 17 patients had clear and compact central cornea and reasonably good vision at the time of specular microscopy. Those with best corrected visual acuity <20/20 had cataract as a co-morbidity. Endothelial abnormalities were noted in all patients and were documented using Hirst and modified Sherrard's classification system. As per the modified Sherrard's classification system, 9 eyes were categorised into total ICE, 5 eyes into subtotal ICE, in 3 eyes grading could not be applied. Of the 4 subtotal ICE, 1 was subtotal ICE (+) and 3 were subtotal ICE (-). 12/17 patients had glaucomatous disc. CONCLUSIONS: Specular microscopy provides information on the various morphological pattern of endothelial abnormalities and helps in mapping out the areas with abnormal/diseased endothelium. These have implications in the management of ICE syndrome.


Asunto(s)
Edema Corneal , Síndrome Endotelial Iridocorneal , Adulto , Córnea , Edema Corneal/diagnóstico , Endotelio Corneal , Femenino , Humanos , Síndrome Endotelial Iridocorneal/diagnóstico , Masculino , Microscopía , Persona de Mediana Edad
11.
Am J Ophthalmol ; 229: 34-44, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33667399

RESUMEN

PURPOSE: To report on the 15-year incidence of primary angle closure disease (PACD) among participants aged ≥40 years in rural southern India DESIGN: Population-based longitudinal incidence rate study METHODS: Setting: 3 rural study centres. STUDY POPULATION: Phakic participants aged ≥40 years who participated in both examination time points. OBSERVATION PROCEDURES: All participants at the baseline and at the mean 15-year follow-up visit underwent a detailed interview, anthropometry, blood pressure measurement, and comprehensive eye examination. Automated perimetry was attempted based on predefined criteria. Main outcome measures included development of any form of PACD, as defined by the International Society for Geographical and Epidemiological Ophthalmology (ISGEO), during the follow-up period in phakic participants, who did not have the disease at baseline. RESULTS: We analyzed data obtained from 1,197 (81.4% out of available 1,470) participants to calculate the incidence of the disease. The mean age (standard deviation) of the study participants at the baseline was 50.2 (8.1) years, with 670 male (45.5%) and 800 female (54.4%) participants. The incidence rate per 100 person-years (95% confidence interval) for primary angle closure suspect, primary angle closure, and primary angle closure glaucoma was 8.8 (8.4, 9.2), 6.2 (5.9, 6.6), and 1.6 (1.4, 1.8), respectively. Thus, the incidence of all forms of PACD was 16.4 (15.9, 17) per 100 person-years. On logistic regression analysis, female gender was a significant risk factor whereas presence of myopia was protective. CONCLUSIONS: This study reports long-term incidence of PACD from rural India. It has implications for eye health care policies, strategies, and planning.


Asunto(s)
Glaucoma de Ángulo Cerrado , Presión Intraocular , Femenino , Glaucoma de Ángulo Cerrado/diagnóstico , Glaucoma de Ángulo Cerrado/epidemiología , Gonioscopía , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Factores de Riesgo , Pruebas del Campo Visual
13.
J Glaucoma ; 30(1): 5-9, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32969921

RESUMEN

PRECIS: With a newly designed blade, slicing of the Ahmed glaucoma valve (AGV) leaflets helped to convert the flow-restrictive AGV into a non-flow-restrictive device. Flow characteristics by our in-vitro study confirmed the loss of resistance of AGV valve leaflets. PURPOSE: To describe a new blade to destroy the valve leaflets of AGV and to report the in-vitro flow characteristics of AGV after valve destruction. METHODS: All the newly opened AGV implants and the Aurolab aqueous drainage implants (AADI, used as controls) were tested by connecting to a 27-G cannula, open manometer, digital manometer, and automated infusion pump. Data logging was done using a digital manometer at 4 Hz using computerized software. When the AGV's flow characterization reached the steady phase, their valve functionality was destroyed by disrupting the valve leaflets, using a specially designed blade. The flow characteristics after valve slicing were compared with that of AADI. RESULTS: A total of 5 FP7 AGVs and 2 AADIs were tested. After initial resistance to flow (5, 8 mm Hg) observed in the case of AADI for 1 to 3 hours, it dropped to 1 mm Hg in both the implants. The flow-restrictive AGV showed 3 distinct phases in the flow characterization. The first phase included the transient phase followed by the steady phase wherein the pressure was 11.2±2.6 (min 7, max 14) mm Hg. The pressure resistance of the AGV dropped significantly (P<0.001) to a mean of 0.4±0.54 mm Hg (1 mm Hg in 2 devices and 0 mm Hg in 3 devices) after the valve functionality was destroyed. The average time taken for this drop in pressure resistance after valve slicing was 10.2±3.0 minutes (min 7, max 15). CONCLUSIONS: It was possible to convert the flow-restrictive AGV into a non-flow-restrictive device by destroying the functionality of the valve leaflets. The pressure of the AGVs was similar to AADI after destroying its valve functionality.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma , Catéteres , Glaucoma/cirugía , Humanos , Presión Intraocular , Implantación de Prótesis
14.
Ophthalmol Glaucoma ; 4(1): 89-94, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32801019

RESUMEN

PURPOSE: To study the agreement between the Icare ic200 (ICare Finland Oy, Helsinki, Finland) and the Goldmann Applanation Tonometer (GAT) in the measurement of intraocular pressure (IOP) in adult eyes. DESIGN: Noninterventional, cross-sectional study. PARTICIPANTS: A total of 156 eyes of 156 adult participants with clear corneas were included. METHODS: The IOP measurements were obtained with the Icare ic200 by 1 observer followed by GAT readings by a second masked observer. The central corneal thickness (CCT) and biometry of all subjects were recorded. MAIN OUTCOME MEASURES: The agreement between Icare ic200 and GAT was measured using the Bland-Altman plot. RESULTS: The mean age ± standard deviation of subjects was 55.3 ± 13.7 years. The GAT IOP ranged from 6 to 50 mmHg with a mean IOP of 19.5 ± 8.8 mmHg. The Icare ic200 IOP ranged from 7.4 to 50 mmHg with a mean IOP of 20.8 ± 9.3 mmHg. The mean difference between the IOP measurement of GAT and Icare ic200 was -1.27 mmHg with the 95% limits of agreement (LoA) ranging from -3.4 to 0.9 mmHg for all ranges of IOP. The mean difference (95% LoA) between the IOP measurement of GAT and Icare ic200 was -1 mmHg (-3 to 1 mmHg) and -1.8 mmHg (-4 to 0.2 mmHg) for a GAT IOP ≤21 mmHg and >21 mmHg, respectively. The CCT, axial length, age, and gender did not significantly affect the difference in measurement of IOP between the 2 tonometers. However, for every 1-mmHg increase in GAT IOP, the difference between the 2 tonometers increased by 0.04 mmHg (P < 0.001). CONCLUSIONS: In our study, the Icare ic200 overestimated the IOP. The overestimation increased as the baseline IOP increased. The agreement between the IOP measurement by GAT and Icare ic200 was <2 mmHg at all ranges of IOP. The narrow LoA between the tonometers for an IOP <21 mmHg makes it a useful alternative to GAT in this pressure range.


Asunto(s)
Presión Intraocular , Tonometría Ocular , Adulto , Córnea , Estudios Transversales , Humanos , Reproducibilidad de los Resultados
15.
Eye (Lond) ; 34(8): 1399-1405, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31695161

RESUMEN

OBJECTIVES: To assess the ability of teleophthalmoscopic grading of peripheral anterior chamber depth (PACD) using the van Herick (vH) technique in detecting gonioscopically occludable angle; and to determine whether combining results from vH grading and ocular biometry can improve the accuracy to diagnose gonioscopically occludable angle METHODS: This cross-sectional study was an offshoot of a rural population-based study, Glaucoma Epidemiology and Molecular Genetic Study (GLEAMS). A masked urban ophthalmologist graded digital slit lamp photographs of PACD by vH technique. Sussman four-mirror lens was used to perform dark room indentation gonioscopy. Cutoff values of the tests were, vH technique: grade ≤ 2, central anterior chamber depth (ACD), as well as axial length: ≤ 25th percentile and lens thickness ≥ 75th percentile value of the study population. RESULTS: We studied 1965 eyes of 1029 adult participants. The vH grade was ≤2 in 188 (9.5%) eyes. The angle was occludable by gonioscopy in 101 (5.1%) eyes. The performance of the vH test to rule out gonioscopically occludable angle was good [negative predictive value (NPV): 97.3%], despite low sensitivity (52.5%), while its efficacy to rule in the condition was low [positive predictive value (PPV): 28.2%] despite high specificity (92.8%). However, test combination strategy increased the PPV nearly twofold (53.8%). The calculated PPV at 10% prevalence of gonioscopically occludable angle was even higher (70.5%). CONCLUSIONS: Van Herick technique can be incorporated into a teleophthalmology program by means of slit lamp photographs of PACD. Combined vH grading and ocular biometry improved the predictability of a gonioscopically occludable angle.


Asunto(s)
Glaucoma de Ángulo Cerrado , Glaucoma , Oftalmología , Telemedicina , Adulto , Cámara Anterior , Estudios Transversales , Glaucoma de Ángulo Cerrado/diagnóstico , Glaucoma de Ángulo Cerrado/epidemiología , Glaucoma de Ángulo Cerrado/genética , Gonioscopía , Humanos , Biología Molecular
16.
Indian J Ophthalmol ; 67(11): 1870-1872, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31638052

RESUMEN

Phacotrabeculectomy is the preferred surgical management of coexisting visually significant cataract and moderate to advanced glaucoma. We report the surgical technique of a new modified fornix-based separate-site phacotrabeculectomy, with mitomycin C (MMC) application, in both primary open angle and angle closure glaucoma. In this new separate-site technique, both phaco and filtration are accommodated superiorly, side by side, hence called twin-site. This was achieved in an efficacious and safe manner with sparing of limbal stem cells without compromising safety. It is not only MMC-compatible but also has a low incidence of wound leak. The technique has no adverse consequence on the survival of the bleb, and we achieved complete success in 79.2% and total success in 93.1% in 130 eyes of 117 patients, in the intermediate term. Furthermore, the time taken for this separate-site surgical technique is comparable to published one-site procedures.


Asunto(s)
Catarata/complicaciones , Glaucoma de Ángulo Cerrado/cirugía , Glaucoma de Ángulo Abierto/cirugía , Facoemulsificación/métodos , Esclerótica/cirugía , Colgajos Quirúrgicos , Trabeculectomía/métodos , Antibióticos Antineoplásicos/farmacología , Catarata/diagnóstico , Glaucoma de Ángulo Cerrado/complicaciones , Glaucoma de Ángulo Cerrado/fisiopatología , Glaucoma de Ángulo Abierto/complicaciones , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Mitomicina/farmacología , Agudeza Visual
17.
Ophthalmic Epidemiol ; 26(6): 430-438, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31389761

RESUMEN

Purpose: To report on diagnostic accuracy of van Herick (vH) technique performed by a vision technician (VT) as well as on efficacy of a combination of vH technique and central anterior chamber depth (ACD) in detection of primary angle closure disease.Methods: Data was obtained from two cohorts; rural clinic setting (n = 111), and rural population-based research setting (n = 888). Van Herick grading was performed by a VT in first cohort and a glaucoma specialist in second cohort. A reference standard four-mirror gonioscopy was performed by a glaucoma specialist in both cohorts. We did preferential sampling. Cut-off levels for vH technique and central ACD were grade 2 and 25th percentile value, respectively. Data from one eye per participant was analyzed.Results: Three hundred and forty (34%) eyes were gonioscopically occludable. Area under receiver operating characteristic curve (95% confidence interval) for vH test was 0.83 (0.76, 0.9) and 0.81 (0.78, 0.84) in first and second cohorts, respectively. Simultaneous testing achieved sensitivity of 87.8% while sequential testing achieved specificity of 99.3%. Negative predictive value* of simultaneous testing was 98.3% compared to 96.6% of vH technique while positive predictive value* of sequential testing was 86% compared to 49.3% of vH technique. (*at 10% prevalence of gonioscopically occludable angle)Conclusions: Diagnostic accuracy of vH grading was similar when performed by a VT and a glaucoma specialist. While test combination was effective to rule in, vH technique may suffice to rule out the disease. Implications of these findings for resource-constrained regions are discussed.


Asunto(s)
Técnicas de Diagnóstico Oftalmológico , Glaucoma de Ángulo Cerrado/diagnóstico , Adulto , Anciano , Área Bajo la Curva , Estudios Transversales , Pruebas Diagnósticas de Rutina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Áreas de Pobreza , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
18.
Ophthalmic Epidemiol ; 26(6): 420-429, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31340705

RESUMEN

Purpose: L. V. Prasad Eye Institute has adopted horizontal approach of eye care delivery for the past 22 years at one of its rural secondary centers. The recent implementation of a diagonal model for enhancing glaucoma care at this center and its outcomes are reported.Methods: This was a retrospective case-control study. We included newly and consecutively diagnosed adult glaucoma patients. A comprehensive ophthalmologist provided glaucoma care. During the study period, an experienced glaucoma specialist supported the care for 2 days every month in a structured format that consisted of triaging glaucoma patients for defined protocols of therapy along with hands-on and remote online guidance to the comprehensive ophthalmologist. The data from the worst or single eye were analyzed.Results: We have included 231 patients (151 study and 80 historical controls). Sixty (75%) control patients were managed at the study center and 20 (25%) were referred. The comprehensive ophthalmologist managed 70 (48.2%) study patients and co-managed 75 (51.7%) with the glaucoma specialist. The latter changed the diagnosis in 15 eyes and altered the treatment plan in 44 eyes. Six were excluded. Successful outcome was achieved in 52 (65%) eyes in the control group and 120 (84.5%) eyes in the study group (P < .01). Additionally, study group did better in terms of case detection rate, compliance to treatment and saving on expenses for patients.Conclusion: The new model has shown better clinical outcomes of glaucoma care in an under-served geographic area. The model has the potential for wider applicability.


Asunto(s)
Atención a la Salud/organización & administración , Glaucoma/terapia , Oftalmología/organización & administración , Servicios de Salud Rural/organización & administración , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
19.
J Glaucoma ; 28(6): 507-511, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30950966

RESUMEN

PRECIS: We checked 190 tonometers every month and repaired faulty ones. Calibration error (CE) frequency reduced from 23% to 0.6% at 1 year. Tonometers needing one or >1 CE repair differed in survival but not in age. PURPOSE: The purpose of this study was to report the outcomes of a comprehensive program to maintain calibration status of the Goldmann applanation tonometer. METHODS: This prospective cohort study was carried out at 2 tertiary eye care referral centers. We included 190 slit-lamp mounted Goldmann applanation tonometers (Model AT 900 C/M). Health care providers (error checking and reporting) and clinical engineers (maintenance) participated. The team carried out CE check once a month, and repair of faulty tonometers, if any, within 24 hours. Failure of tonometer was defined as development of unacceptable CE beyond the third repair. The main outcome measures were the frequency of CE and survival function of the tonometer over 1 year. RESULTS: The median age of the tonometers was 10.7 (range, 0.2 to 25.1) years. The total number of repairs was 86. The proportion (95% confidence interval) of faulty tonometers reduced from 23.1% (17.7, 29.6) in the first month to 0.6% (0.1, 3.3) at 1 year (P<0.01). The median age of the tonometer did not differ between those needing (n=63, 9.4 y) and not needing (n=127, 10.7 y; P=0.24) repair. All tonometers requiring 1 CE repair (n=49, 25.7%) survived until 1 year. The survival of tonometers requiring >1 CE repair (n=14, 7.3%) was 40% at 1 year. CONCLUSIONS: Our in-house program maintained 92.6% tonometers error free. Number of repairs rather than age determined the need for replacement/sending back the tonometer to the manufacturer. Our simple and easy to follow maintenance program has the potential for wide application.


Asunto(s)
Utilización de Equipos y Suministros/organización & administración , Centros de Atención Terciaria/organización & administración , Tonometría Ocular/instrumentación , Tonometría Ocular/normas , Calibración , Estudios de Cohortes , Diseño de Equipo , Falla de Equipo/estadística & datos numéricos , Utilización de Equipos y Suministros/normas , Utilización de Equipos y Suministros/estadística & datos numéricos , Humanos , Presión Intraocular , Mantenimiento/métodos , Mantenimiento/organización & administración , Oftalmología/organización & administración , Oftalmología/normas , Oftalmología/estadística & datos numéricos , Evaluación de Resultado en la Atención de Salud , Evaluación de Programas y Proyectos de Salud , Estudios Prospectivos , Reproducibilidad de los Resultados , Centros de Atención Terciaria/normas , Centros de Atención Terciaria/estadística & datos numéricos , Tonometría Ocular/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...