Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Biomed Opt ; 27(12): 126003, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36530345

RESUMEN

Significance: Mueller matrix polarimetry (MMP) and spatial frequency domain imaging (SFDI) are wide-field optical imaging modalities that differentiate tissue primarily by structure alignment and photon transport coefficient, respectively. Because these effects can be related, combining MMP and SFDI may enhance tissue differentiation beyond the capability of each modality alone. Aim: An instrument was developed to combine MMP and SFDI with the goal of testing whether it enhances contrast of features in reflection mode. Approach: The instrument was constructed using liquid crystal elements for polarization control, a digital light processing projector for generating sinusoidal illumination patterns, and a digital camera for imaging. A theoretical analysis shows that the SFD Mueller matrix is complex-valued and does not follow the same behavior as a regular Mueller matrix. Images were acquired from an anisotropic tissue phantom, an optical fiber bundle, and cerebellum, thalamus, and cerebrum tissues. Results: The measurement results suggest that singly scattered, few scattered, and diffusely scattered photon paths can be distinguished in some of the samples investigated. The combined imaging modality yields additional spatial frequency phase information, which highlights paths having only a few scattering events. Conclusions: The combination of MMP and SFDI offers contrast mechanisms inaccessible by each modality used alone.


Asunto(s)
Imagen Óptica , Fantasmas de Imagen , Imagen Óptica/métodos , Anisotropía , Análisis Espectral
2.
Opt Lett ; 45(8): 2168-2171, 2020 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-32287183

RESUMEN

Reflectance Mueller matrix (MM) polarimetry is being used to characterize biological media in multiple clinical applications. The origin of the reflectance polarimetric data is often unclear due to the impact of multiple scattering and tissue heterogeneity. We have developed a new, to the best of our knowledge, multimodal imaging technique combining MM reflectance, MM digital confocal imaging, and co-registered nonlinear microscopy techniques. The instrument unveils the origin of reflectance polarimetric signature in terms of confocal reflectance data. The reconstructed reflected MM demonstrates the capability of our method to provide depth-resolved 3D polarization response from complex biological media in terms of depolarization, retardance, and orientation parameters.


Asunto(s)
Microscopía/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados
3.
J Biomed Opt ; 24(3): 1-12, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30851015

RESUMEN

Calibration, quantification, and standardization of the polarimetric instrumentation, as well as interpretation and understanding of the obtained data, require the development and use of well-calibrated phantoms and standards. We reviewed the status of tissue phantoms for a variety of applications in polarimetry; more than 500 papers are considered. We divided the phantoms into five groups according to their origin (biological/nonbiological) and fundamental polarimetric properties of retardation, depolarization, and diattenuation. We found that, while biological media are generally depolarizing, retarding, and diattenuating, only one of all the phantoms reviewed incorporated all these properties, and few considered at least combined retardation and depolarization. Samples derived from biological tissue, such as tendon and muscle, remain extremely popular to quickly ascertain a polarimetric system, but do not provide quantifiable results aside from relative direction of their principal optical axis. Microspheres suspensions are the most utilized phantoms for depolarization, and combined with theoretical models can offer true quantification of depolarization or degree of polarization. There is a real paucity of birefringent phantoms despite the retardance being one of the most interesting parameters measurable with polarization techniques. Therefore, future work should be directed at generating truly reliable and repeatable phantoms for this metric determination. Diattenuating phantoms are rare and application-specific. Given that diattenuation is considered to be low in most biological tissues, the lack of such phantoms is seen as less problematic. The heterogeneity of the phantoms reviewed points to a critical need for standardization in this field. Ultimately, all research groups involved in polarimetric studies and instruments development would benefit from sharing a limited set of standardized polarimetric phantoms, as is done earlier in the round robin investigations in ellipsometry.


Asunto(s)
Imagen Óptica/instrumentación , Fantasmas de Imagen , Dispersión de Radiación , Anisotropía , Microesferas
4.
J Biomed Opt ; 23(12): 1-9, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-30088376

RESUMEN

Annually, about 15 million preterm infants are born in the world. Of these, due to complications resulting from their premature birth, about 1 million would die before the age of five. Since the high incidence of preterm birth (PTB) is partially due to the lack of effective diagnostic modalities, methodologies are needed to determine risk of PTB. We propose a noninvasive tool based on polarized light imaging aimed at measuring the organization of collagen in the cervix. Cervical collagen has been shown to remodel with the approach of parturition. We used a full-field Mueller matrix polarimetric colposcope to assess and compare cervical collagen content and structure in nonpregnant and pregnant women in vivo. Local collagen directional azimuth was used and a total of eight cervices were imaged.


Asunto(s)
Cuello del Útero/diagnóstico por imagen , Colposcopía/métodos , Anisotropía , Birrefringencia , Colágeno/química , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Recien Nacido Prematuro , Embarazo , Nacimiento Prematuro , Medición de Riesgo , Tomografía de Coherencia Óptica
6.
J Biomed Opt ; 22(8): 1-9, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28853246

RESUMEN

Preterm birth (PTB) presents a serious medical health concern throughout the world. There is a high incidence of PTB in both developed and developing countries ranging from 11% to 15%, respectively. Recent research has shown that cervical collagen orientation and distribution changes during pregnancy may be useful in predicting PTB. Polarization imaging is an effective means to measure optical anisotropy in birefringent materials, such as the cervix's extracellular matrix. Noninvasive, full-field Mueller matrix polarimetry (MMP) imaging methodologies, and optical coherence tomography (OCT) imaging were used to assess cervical collagen content and structure in nonpregnant porcine cervices. We demonstrate that the highly ordered structure of the nonpregnant porcine cervix can be observed with MMP. Furthermore, when utilized ex vivo, OCT and MMP yield very similar results with a mean error of 3.46% between the two modalities.


Asunto(s)
Anisotropía , Cuello del Útero/química , Colágeno/química , Matriz Extracelular/química , Nacimiento Prematuro/etiología , Tomografía de Coherencia Óptica/métodos , Animales , Birrefringencia , Femenino , Análisis Espectral , Porcinos
7.
J Biomed Opt ; 21(7): 71109, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26934019

RESUMEN

Mueller matrix polarimetry and polarization-sensitive optical coherence tomography (PS-OCT) are two emerging techniques utilized in the assessment of tissue anisotropy. While PS-OCT can provide cross-sectional images of local tissue birefringence through its polarimetric sensitivity, Mueller matrix polarimetry can be used to measure bulk polarimetric properties such as depolarization, diattenuation, and retardance. To this day true quantification of PS-OCT data can be elusive, partly due to the reliance on inverse models for the characterization of tissue birefringence and the influence of instrumentation noise. Similarly for Mueller matrix polarimetry, calculation of retardance or depolarization may be influenced by tissue heterogeneities that could be monitored with PS-OCT. Here, we propose an instrument that combines Mueller matrix polarimetry and PS-OCT. Through the co-registration of the two systems, we aim at achieving a better understanding of both modalities.


Asunto(s)
Colágeno/química , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía de Coherencia Óptica/métodos , Animales , Pollos , Válvulas Cardíacas/fisiología , Modelos Teóricos , Papio , Tendones/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...