Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
Phys Med ; 124: 103421, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38968695

RESUMEN

PURPOSE: To investigate the role of dosiomics features extracted from physical dose (DPHYS), RBE-weighted dose (DRBE) and dose-averaged Linear Energy Transfer (LETd), to predict the risk of local recurrence (LR) in skull base chordoma (SBC) treated with Carbon Ion Radiotherapy (CIRT). Thus, define and evaluate dosiomics-driven tumor control probability (TCP) models. MATERIALS AND METHODS: 54 SBC patients were retrospectively selected for this study. A regularized Cox proportional hazard model (r-Cox) and Survival Support Vector Machine (s-SVM) were tuned within a repeated Cross Validation (CV) and patients were stratified in low/high risk of LR. Models' performance was evaluated through Harrell's concordance statistic (C-index), and survival was represented through Kaplan-Meier (KM) curves. A multivariable logistic regression was fit to the selected feature sets to generate a dosiomics-driven TCP model for each map. These were compared to a reference model built with clinical parameters in terms of f-score and accuracy. RESULTS: The LETd maps reached a test C-index of 0.750 and 0.786 with r-Cox and s-SVM, and significantly separated KM curves. DPHYS maps and clinical parameters showed promising CV outcomes with C-index above 0.8, despite a poorer performance on the test set and patients stratification. The LETd-based TCP showed a significatively higher f-score (0.67[0.52-0.70], median[IQR]) compared to the clinical model (0.4[0.32-0.63], p < 0.025), while DPHYS achieved a significatively higher accuracy (DPHYS: 0.73[0.65-0.79], Clinical: 0.6 [0.52-0.72]). CONCLUSION: This analysis supports the role of LETd as relevant source of prognostic factors for LR in SBC treated with CIRT. This is reflected in the TCP modeling, where LETd and DPHYS showed an improved performance with respect to clinical models.

2.
Int J Part Ther ; 12: 100100, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39022120

RESUMEN

Purpose: The aim of this study is to determine the most beneficial radiation treatment technique for pediatric patients with thoracic and abdominal neuroblastoma (NBL), through a dosimetric comparison between photon Volumetric Modulated Arc Therapy and proton Intensity-Modulated Proton Therapy treatment plans. Materials and Methods: A retrospective analysis was conducted on a multicentre case series of 19 patients with thoracic and/or abdominal NBL who underwent radiation therapy, following the recommendations of the European protocol for high-risk NBL (HR-NBL2/SIOPEN). The prescribed dose was 21.6 Gy in 12 fractions (1.8 Gy/fraction) delivered over the preoperative disease volume. The dose volume histograms were analyzed for each patient, and a Wilcoxon signed-rank test with a significance level of 0.01 was employed to assess statistical differences between the dosimetric parameters investigated. Two homogeneity indices (HI and newHI) were compared to evaluate the uniformity in dose, delivered to the adjacent vertebrae (VBs_Adj). Results: Both radiation techniques conform to the protocol regarding CTV/PTV coverage for every location. Proton therapy resulted in statistically significant dose sparing for the heart and lungs in supradiaphragmatic locations and for the contralateral kidney, liver, spleen, and bowel in subdiaphragmatic locations. For both techniques, sparing the non-adjacent vertebrae (VBs_NAdj) results more challenging, although promising results were obtained. Furthermore, the dose delivered to the VBs_Adj was not statistically different, in terms of homogeneity, for the 2 radiation techniques that both met the protocol's requirements. Conclusion: This dosimetric analysis highlights the potential of protons to reduce radiation dose to healthy tissue. These findings apply to all the investigated patients, regardless of primary tumor location, making proton therapy a valuable option for the treatment of neuroblastoma. However, a multidisciplinary assessment of each case is essential to ensure the selection of the most effective and suitable treatment modality.

3.
J Neurooncol ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38918319

RESUMEN

PURPOSE: To report the outcomes of a large series of intracranial meningiomas (IMs) submitted to proton therapy (PT) with curative intent. METHODS: We conducted a retrospective analysis on all consecutive IM patients treated between 2014 and 2021. The median PT prescription dose was 55.8 Gy relative biological effectiveness (RBE) and 66 GyRBE for benign/radiologically diagnosed and atypical/anaplastic IMs, respectively. Local recurrence-free survival (LRFS), distant recurrence-free survival (DRFS), overall survival (OS), and radionecrosis-free survival (RNFS) were evaluated with the Kaplan-Meier method. Univariable analysis was performed to identify potential prognostic factors for clinical outcomes. Toxicity was reported according to the latest Common Terminology Criteria for Adverse Events (CTCAE) version 5.0. RESULTS: Overall, 167 patients were included. With a median follow-up of 41 months (range, 6-99), twelve patients (7%) developed tumor local recurrence after a median time of 39 months. The 5-year LRFS was 88% for the entire cohort, with a significant difference between benign/radiologically diagnosed and atypical/anaplastic IMs (98% vs. 47%, p < 0.001); this significant difference was maintained also for the 5-year OS and the 5-year DRFS rates. Patients aged ≤ 56 years reported significantly better outcomes, whereas lower prescription doses and skull base location were associated with better RNFS rates. Two patients experienced G3 acute toxicities (1.2%), and three patients G3 late toxicities (1.8%). There were no G4-G5 adverse events. CONCLUSION: PT proved to be effective with an acceptable toxicity profile. To the best of our knowledge this is one of the largest series including IM patients submitted to PT.

4.
Med Phys ; 51(7): 5154-5158, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38598230

RESUMEN

PURPOSE: As carbon ion radiotherapy increases in use, there are limited phantom materials for heterogeneous or anthropomorphic phantom measurements. This work characterized the radiological clinical equivalence of several phantom materials in a therapeutic carbon ion beam. METHODS: Eight materials were tested for radiological material-equivalence in a carbon ion beam. The materials were computed tomography (CT)-scanned to obtain Hounsfield unit (HU) values, then irradiated in a monoenergetic carbon ion beam to determine relative linear stopping power (RLSP). The corresponding HU and RLSP for each phantom material were compared to clinical carbon ion calibration curves. For absorbed dose comparison, ion chamber measurements were made in the center of a carbon ion spread-out Bragg peak (SOBP) in water and in the phantom material, evaluating whether the material perturbed the absorbed dose measurement beyond what was predicted by the HU-RLSP relationship. RESULTS: Polyethylene, solid water (Gammex and Sun Nuclear), Blue Water (Standard Imaging), and Techtron HPV had measured RLSP values that agreed within ±4.2% of RLSP values predicted by the clinical calibration curve. Measured RLSP for acrylic was 7.2% different from predicted. The agreement for balsa wood and cork varied between samples. Ion chamber measurements in the phantom materials were within 0.1% of ion chamber measurements in water for most materials (solid water, Blue Water, polyethylene, and acrylic), and within 1.9% for the rest of the materials (balsa wood, cork, and Techtron HPV). CONCLUSIONS: Several phantom materials (Blue Water, polyethylene, solid water [Gammex and Sun Nuclear], and Techtron HPV) are suitable for heterogeneous phantom measurements for carbon ion therapy. Low density materials should be carefully characterized due to inconsistencies between samples.


Asunto(s)
Radioterapia de Iones Pesados , Fantasmas de Imagen , Radioterapia de Iones Pesados/instrumentación , Calibración , Tomografía Computarizada por Rayos X , Humanos
5.
Phys Med Biol ; 69(11)2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38663410

RESUMEN

Objective. This study characterized optically-stimulated luminescent dosimeter (OSLD) nanoDots for use in a therapeutic carbon beam using the Imaging and Radiation Oncology Core (IROC) framework for remote output verification.Approach. The absorbed dose correction factors for OSLD (fading, linearity, beam quality, angularity, and depletion), as defined by AAPM TG 191, were characterized for carbon beams. For the various correction factors, the effect of linear energy transfer (LET) was examined by characterizing in both a low and high LET setting.Main results. Fading was not statistically different between reference photons and carbon, nor between low and high LET beams; thus, the standard IROC-defined exponential function could be used to characterize fading. Dose linearity was characterized with a linear fit; while low and high LET carbon linearity was different, these differences were small and could be rolled into the uncertainty budget if using a single linearity correction. A linear fit between beam quality and dose-averaged LET was determined. The OSLD response at various angles of incidence was not statistically different, thus a correction factor need not be applied. There was a difference in depletion between low and high LET irradiations in a primary carbon beam, but this difference was small over the standard five readings. The largest uncertainty associated with the use of OSLDs in carbon was because of thekQcorrection factor, with an uncertainty of 6.0%. The overall uncertainty budget was 6.3% for standard irradiation conditions.Significance. OSLD nanoDot response was characterized in a therapeutic carbon beam. The uncertainty was larger than for traditional photon applications. These findings enable the use of OSLDs for carbon absorbed dose measurements, but with less accuracy than conventional OSLD audit programs.


Asunto(s)
Carbono , Carbono/química , Carbono/uso terapéutico , Radiometría/métodos , Transferencia Lineal de Energía , Incertidumbre , Dosimetría con Luminiscencia Ópticamente Estimulada/métodos , Dosificación Radioterapéutica , Humanos
6.
Phys Med ; 120: 103329, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38492331

RESUMEN

GOAL: In-beam Positron Emission Tomography (PET) is a technique for in-vivo non-invasive treatment monitoring for proton therapy. To detect anatomical changes in patients with PET, various analysis methods exist, but their clinical interpretation is problematic. The goal of this work is to investigate whether the gamma-index analysis, widely used for dose comparisons, is an appropriate tool for comparing in-beam PET distributions. Focusing on a head-and-neck patient, we investigate whether the gamma-index map and the passing rate are sensitive to progressive anatomical changes. METHODS/MATERIALS: We simulated a treatment course of a proton therapy patient using FLUKA Monte Carlo simulations. Gradual emptying of the sinonasal cavity was modeled through a series of artificially modified CT scans. The in-beam PET activity distributions from three fields were evaluated, simulating a planar dual head geometry. We applied the 3D-gamma evaluation method to compare the PET images with a reference image without changes. Various tolerance criteria and parameters were tested, and results were compared to the CT-scans. RESULTS: Based on 210 MC simulations we identified appropriate parameters for the gamma-index analysis. Tolerance values of 3 mm/3% and 2 mm/2% were suited for comparison of simulated in-beam PET distributions. The gamma passing rate decreased with increasing volume change for all fields. CONCLUSION: The gamma-index analysis was found to be a useful tool for comparing simulated in-beam PET images, sensitive to sinonasal cavity emptying. Monitoring the gamma passing rate behavior over the treatment course is useful to detect anatomical changes occurring during the treatment course.


Asunto(s)
Terapia de Protones , Humanos , Terapia de Protones/métodos , Método de Montecarlo , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Simulación por Computador , Etopósido , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
7.
Phys Imaging Radiat Oncol ; 29: 100553, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38419802

RESUMEN

Background and Purpose: Nuclear interaction correction (NIC) and trichrome fragment spectra modelling improve relative biological effectiveness-weighted dose (DRBE) and dose-averaged linear energy transfer (LETd) calculation for carbon ions. The effect of those novel approaches on the clinical dose and LET distributions was investigated. Materials and Methods: The effect of the NIC and trichrome algorithm was assessed, creating single beam plans for a virtual water phantom with standard settings and NIC + trichrome corrections. Reference DRBE and LETd distributions were simulated using FLUKA version 2021.2.9. Thirty clinically applied scanned carbon ion treatment plans were recalculated applying NIC, trichrome and NIC + trichrome corrections, using the LEM low dose approximation and compared to clinical plans (base RS). Four treatment sites were analysed: six prostate adenocarcinoma, ten head and neck, nine locally advanced pancreatic adenocarcinoma and five sacral chordoma. The FLUKA and clinical plans were compared in terms of DRBE deviations for D98%, D50%, D2% for the clinical target volume (CTV) and D50% in ring-like dose regions retrieved from isodose curves in base RS plans. Additionally, region-based median LETd deviations and global gamma parameters were evaluated. Results: Dose deviations comparing base RS and evaluation plans were within ± 1% supported by γ-pass rates over 97% for all cases. No significant LETd deviations were reported in the CTV, but significant median LETd deviations were up to 80% for very low dose regions. Conclusion: Our results showed improved accuracy of the predicted DRBE and LETd. Considering clinically relevant constraints, no significant modifications of clinical protocols are expected with the introduction of NIC + trichrome.

8.
Phys Med Biol ; 69(6)2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38373343

RESUMEN

Objective.This study addresses a fundamental limitation of in-beam positron emission tomography (IB-PET) in proton therapy: the lack of direct anatomical representation in the images it produces. We aim to overcome this shortcoming by pioneering the application of deep learning techniques to create synthetic control CT images (sCT) from combining IB-PET and planning CT scan data.Approach.We conducted simulations involving six patients who underwent irradiation with proton beams. Leveraging the architecture of a visual transformer (ViT) neural network, we developed a model to generate sCT images of these patients using the planning CT scans and the inter-fractional simulated PET activity maps during irradiation. To evaluate the model's performance, a comparison was conducted between the sCT images produced by the ViT model and the authentic control CT images-serving as the benchmark.Main results.The structural similarity index was computed at a mean value across all patients of 0.91, while the mean absolute error measured 22 Hounsfield Units (HU). Root mean squared error and peak signal-to-noise ratio values were 56 HU and 30 dB, respectively. The Dice similarity coefficient exhibited a value of 0.98. These values are comparable to or exceed those found in the literature. More than 70% of the synthetic morphological changes were found to be geometrically compatible with the ones reported in the real control CT scan.Significance.Our study presents an innovative approach to surface the hidden anatomical information of IB-PET in proton therapy. Our ViT-based model successfully generates sCT images from inter-fractional PET data and planning CT scans. Our model's performance stands on par with existing models relying on input from cone beam CT or magnetic resonance imaging, which contain more anatomical information than activity maps.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Terapia de Protones , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Terapia de Protones/métodos , Tomografía Computarizada por Rayos X/métodos , Redes Neurales de la Computación , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones , Planificación de la Radioterapia Asistida por Computador/métodos
9.
Sci Rep ; 14(1): 418, 2024 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-38172585

RESUMEN

Boron Neutron Capture Therapy (BNCT) is a radiotherapy technique based on the enrichment of tumour cells with suitable 10-boron concentration and on subsequent neutron irradiation. Low-energy neutron irradiation produces a localized deposition of radiation dose caused by boron neutron capture reactions. Boron is vehiculated into tumour cells via proper borated formulations, able to accumulate in the malignancy more than in normal tissues. The neutron capture releases two high-LET charged particles (i.e., an alpha particle and a lithium ion), losing their energy in a distance comparable to the average dimension of one cell. Thus BNCT is selective at the cell level and characterized by high biological effectiveness. As the radiation field is due to the interaction of neutrons with the components of biological tissues and with boron, the dosimetry requires a formalism to express the absorbed dose into photon-equivalent units. This work analyzes a clinical case of an adenoid cystic carcinoma treated with carbon-ion radiotherapy (CIRT), located close to optic nerve and deep-seated as a practical example of how to apply the formalism of BNCT photon isoeffective dose and how to evaluate the BNCT dose distribution against CIRT. The example allows presenting different dosimetrical and radiobiological quantities and drawing conclusions on the potential of BNCT stemming on the clinical result of the CIRT. The patient received CIRT with a dose constraint on the optic nerve, affecting the peripheral part of the Planning Target Volume (PTV). After the treatment, the tumour recurred in this low-dose region. BNCT was simulated for the primary tumour, with the goal to calculate the dose distribution in isoeffective units and a Tumour Control Probability (TCP) to be compared with the one of the original treatment. BNCT was then evaluated for the recurrence in the underdosed region which was not optimally covered by charged particles due to the proximity of the optic nerve. Finally, a combined treatment consisting in BNCT and carbon ion therapy was considered to show the consistency and the potential of the model. For the primary tumour, the photon isoeffective dose distribution due to BNCT was evaluated and the resulted TCP was higher than that obtained for the CIRT. The formalism produced values that are consistent with those of carbon-ion. For the recurrence, BNCT dosimetry produces a similar TCP than that of primary tumour. A combined treatment was finally simulated, showing a TCP comparable to the BNCT-alone with overall dosimetric advantage in the most peripheral parts of the treatment volume. Isoeffective dose formalism is a robust tool to analyze BNCT dosimetry and to compare it with the photon-equivalent dose calculated for carbon-ion treatment. This study introduces for the first time the possibility to combine the dosimetry obtained by two different treatment modalities, showing the potential of exploiting the cellular targeting of BNCT combined with the precision of charged particles in delivering an homogeneous dose distribution in deep-seated tumours.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Neoplasias de Cabeza y Cuello , Radioterapia de Iones Pesados , Humanos , Terapia por Captura de Neutrón de Boro/métodos , Boro , Carbono , Neutrones
10.
Cancers (Basel) ; 15(20)2023 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-37894434

RESUMEN

BACKGROUND: Currently, 13 Asian and European facilities deliver carbon ion radiotherapy (CIRT) for preclinical and clinical activity, and, to date, 55 clinical studies including CIRT for adult and paediatric solid neoplasms have been registered. The National Center for Oncological Hadrontherapy (CNAO) is the only Italian facility able to accelerate both protons and carbon ions for oncological treatment and research. METHODS: To summarise and critically evaluate state-of-the-art knowledge on the application of carbon ion radiotherapy in oncological settings, the authors conducted a literature search till December 2022 in the following electronic databases: PubMed, Web of Science, MEDLINE, Google Scholar, and Cochrane. The results of 68 studies are reported using a narrative approach, highlighting CNAO's clinical activity over the last 10 years of CIRT. RESULTS: The ballistic and radiobiological hallmarks of CIRT make it an effective option in several rare, radioresistant, and difficult-to-treat tumours. CNAO has made a significant contribution to the advancement of knowledge on CIRT delivery in selected tumour types. CONCLUSIONS: After an initial ramp-up period, CNAO has progressively honed its clinical, technical, and dosimetric skills. Growing engagement with national and international networks and research groups for complex cancers has led to increasingly targeted patient selection for CIRT and lowered barriers to facility access.

11.
Nanomaterials (Basel) ; 13(5)2023 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-36903670

RESUMEN

We present an investigation of the effects on BxPC3 pancreatic cancer cells of proton therapy combined with hyperthermia, assisted by magnetic fluid hyperthermia performed with the use of magnetic nanoparticles. The cells' response to the combined treatment has been evaluated by means of the clonogenic survival assay and the estimation of DNA Double Strand Breaks (DSBs). The Reactive Oxygen Species (ROS) production, the tumor cell invasion and the cell cycle variations have also been studied. The experimental results have shown that the combination of proton therapy, MNPs administration and hyperthermia gives a clonogenic survival that is much smaller than the single irradiation treatment at all doses, thus suggesting a new effective combined therapy for the pancreatic tumor. Importantly, the effect of the therapies used here is synergistic. Moreover, after proton irradiation, the hyperthermia treatment was able to increase the number of DSBs, even though just at 6 h after the treatment. Noticeably, the magnetic nanoparticles' presence induces radiosensitization effects, and hyperthermia increases the production of ROS, which contributes to cytotoxic cellular effects and to a wide variety of lesions including DNA damage. The present study indicates a new way for clinical translation of combined therapies, also in the vision of an increasing number of hospitals that will use the proton therapy technique in the near future for different kinds of radio-resistant cancers.

12.
Phys Med ; 107: 102561, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36898300

RESUMEN

PURPOSE: To fully characterize the flat panel detector of the new Sphinx Compact device with scanned proton and carbon ion beams. MATERIALS AND METHODS: The Sphinx Compact is designed for daily QA in particle therapy. We tested its repeatability and dose rate dependence as well as its proportionality with an increasing number of particles and potential quenching effect. Potential radiation damage was evaluated. Finally, we compared the spot characterization (position and profile FWHM) with our radiochromic EBT3 film baseline. RESULTS: The detector showed a repeatability of 1.7% and 0.9% for single spots of protons and carbon ions, respectively, while for small scanned fields it was inferior to 0.2% for both particles. The response was independent from the dose rate (difference from nominal value < 1.5%). We observed an under-response due to quenching effect for both particles, mostly for carbon ions. No radiation damage effects were observed after two months of weekly use and approximately 1350 Gy delivered to the detector. Good agreement was found between the Sphinx and EBT3 films for the spot position (central-axis deviation within 1 mm). The spot size measured with the Sphinx was larger compared to films. For protons, the average and maximum differences over different energies were 0.4 mm (3%) and 1 mm (7%); for carbon ions they were 0.2 mm (4%) and 0.4 mm (6%). CONCLUSIONS: Despite the quenching effect the Sphinx Compact fulfills the requirements needed for constancy checks and could represent a time-saving tool for daily QA in scanned particle beams.


Asunto(s)
Terapia de Protones , Protones , Radiometría , Carbono , Dosimetría por Película
13.
Bioengineering (Basel) ; 10(2)2023 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-36829745

RESUMEN

The generation of synthetic CT for carbon ion radiotherapy (CIRT) applications is challenging, since high accuracy is required in treatment planning and delivery, especially in an anatomical site as complex as the abdomen. Thirty-nine abdominal MRI-CT volume pairs were collected and a three-channel cGAN (accounting for air, bones, soft tissues) was used to generate sCTs. The network was tested on five held-out MRI volumes for two scenarios: (i) a CT-based segmentation of the MRI channels, to assess the quality of sCTs and (ii) an MRI manual segmentation, to simulate an MRI-only treatment scenario. The sCTs were evaluated by means of similarity metrics (e.g., mean absolute error, MAE) and geometrical criteria (e.g., dice coefficient). Recalculated CIRT plans were evaluated through dose volume histogram, gamma analysis and range shift analysis. The CT-based test set presented optimal MAE on bones (86.03 ± 10.76 HU), soft tissues (55.39 ± 3.41 HU) and air (54.42 ± 11.48 HU). Higher values were obtained from the MRI-only test set (MAEBONE = 154.87 ± 22.90 HU). The global gamma pass rate reached 94.88 ± 4.9% with 3%/3 mm, while the range shift reached a median (IQR) of 0.98 (3.64) mm. The three-channel cGAN can generate acceptable abdominal sCTs and allow for CIRT dose recalculations comparable to the clinical plans.

14.
Front Oncol ; 12: 929949, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36226070

RESUMEN

Morphological changes that may arise through a treatment course are probably one of the most significant sources of range uncertainty in proton therapy. Non-invasive in-vivo treatment monitoring is useful to increase treatment quality. The INSIDE in-beam Positron Emission Tomography (PET) scanner performs in-vivo range monitoring in proton and carbon therapy treatments at the National Center of Oncological Hadrontherapy (CNAO). It is currently in a clinical trial (ID: NCT03662373) and has acquired in-beam PET data during the treatment of various patients. In this work we analyze the in-beam PET (IB-PET) data of eight patients treated with proton therapy at CNAO. The goal of the analysis is twofold. First, we assess the level of experimental fluctuations in inter-fractional range differences (sensitivity) of the INSIDE PET system by studying patients without morphological changes. Second, we use the obtained results to see whether we can observe anomalously large range variations in patients where morphological changes have occurred. The sensitivity of the INSIDE IB-PET scanner was quantified as the standard deviation of the range difference distributions observed for six patients that did not show morphological changes. Inter-fractional range variations with respect to a reference distribution were estimated using the Most-Likely-Shift (MLS) method. To establish the efficacy of this method, we made a comparison with the Beam's Eye View (BEV) method. For patients showing no morphological changes in the control CT the average range variation standard deviation was found to be 2.5 mm with the MLS method and 2.3 mm with the BEV method. On the other hand, for patients where some small anatomical changes occurred, we found larger standard deviation values. In these patients we evaluated where anomalous range differences were found and compared them with the CT. We found that the identified regions were mostly in agreement with the morphological changes seen in the CT scan.

15.
Med Phys ; 49(12): 7802-7814, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36196033

RESUMEN

BACKGROUND: With rapid evolutions of fast and sophisticated calculation techniques and delivery technologies, clinics are almost facing a daily patient-specific (PS) plan adaptation, which would make a conventional experimental quality assurance (QA) workflow unlikely to be routinely feasible. Therefore, in silico approaches are foreseen by means of second-check independent dose calculation systems possibly handling machine log-files. PURPOSE: To validate the in-house developed GPU-dose engine, FRoG, for light ion beam therapy (protons and carbon ions) as a second-check independent calculation system and to integrate machine log-file analysis into the patient-specific quality assurance (PSQA) program. METHODS: Spot sizes, depth-dose distributions, and absolute dose calibrations were configured into FRoG and a set of nine regular-shaped targets in combination with more than 170 clinical treatment fields were tested against pinpoint ionization chamber measurements. Both the treatment planning system DICOM RTplans and machine treatment log-files were used as input for the dose kernel in water, and a 3D local γ (1 mm/2%) index was used as the main evaluation metric. RESULTS: Calculated configuration data matched experimental measurements with submillimetric agreement. For regular-shaped targets, the unsigned average relative difference between calculated and measured dose values was less than 2% for both protons and carbon ions. The mean γ passing rate (PR) was around 98% for both particle species. For clinical treatment beams, DICOM-based recalculations showed a γ-PR more than 99% for both particle species. The same level of agreement was preserved for protons when moving to log-file-based recalculations. A score of around 95% was registered for carbon ion beams, once excluding low-quality machine log-files. Unsigned average relative difference against acquired data was less than 2% also for real clinical beams. CONCLUSIONS: FRoG was proven as an accurate and reliable tool for PSQA in scanning light ion beam therapy. The proposed method allows for an extremely efficient workflow, without compromising the quality of the plan verification procedure.


Asunto(s)
Protones , Radiometría , Humanos , Dosificación Radioterapéutica , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Garantía de la Calidad de Atención de Salud/métodos , Método de Montecarlo
16.
Front Oncol ; 12: 1003494, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36313689

RESUMEN

Introduction: Radiotherapy represents a major treatment option for patients with pancreatic cancer, however, its benefits remain limited also due to the ability of cancer cells to migrate to the surrounding tissues. Low-LET ionizing radiation is well known to promote tumor cell migration and invasion, nevertheless, little data provided by studies using high-LET radiation has led to ambiguous findings. What is hypothesized to be fundamental in the modulation of migration of tumor cells exposed to ionizing radiation is the influence of the microenvironment. Therefore, the properties of cells that populate the tumor stroma cannot be ignored when studying the influence of radiation on the migratory and invasive capacity of cancer cells. This is especially important in the case of pancreatic malignancies that are characterized by an abundance of stromal cells, including cancer-associated fibroblasts, which are known to orchestrate the cross-talk with tumor cells. Aim: The current study aims to investigate whether the presence of factors released by irradiated fibroblasts affects the migratory and invasive capacity of pancreatic cancer cells exposed to different doses of photons or C-ions. Materials and methods: AsPC-1 and AG01522 cells were irradiated with the same dose of photons or C-ions at room temperature. Through Boyden chamber assay, we tested whether factors secreted by irradiated fibroblasts may influence tumor cell migration, while the invasiveness of AsPC-1 cells was assessed using matrigel precoated inserts in which medium collected from non-irradiated (0 Gy), photon and C-ion irradiated fibroblasts, was added. Data were analyzed by Student t-test using GraphPad software. The mean ± s.d. was determined with a significance level of p<0.05. Results: In the presence of conditioned medium collected from 1 Gy and 2 Gy photon irradiated fibroblasts, the number of migrated tumor cells increased (P<0.0360, P<0.0001) but decreased at 4 Gy dose (P<0.002). There was a trend of reduction in migration (P<0.0460, P<0.038, P<0.0024, P<0.0002), as well as a decrease in invasiveness (P<0.0525, P<0.0035, P<0.0868, P<0.0310) after exposure to 0.5 Gy, 1 Gy, 2 Gy and 4 Gy of C-ions. Conclusions: The presence of irradiated fibroblasts affected the invasiveness capability of pancreatic cancer cells, probably by the reciprocal release of soluble factors whose production is differently modulated after high or low-LET radiation. Understanding the effects of irradiation on the metastatic potential of pancreatic cancer cells is of utmost importance for improving the outcome and tailoring the therapeutic approach. This challenging scenario requires a continuous and multidisciplinary approach that involves clinicians together with researcher experts in oncological and radiation treatment. In the last years, including preclinical experiences in a multidisciplinary approach has proved to be a winning strategy in clinical oncological research.

17.
Radiother Oncol ; 176: 1-8, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36113776

RESUMEN

PURPOSE /OBJECTIVE: To quantify benefits of robust optimization on multiple 4DCT acquisitions combined with off-line treatment adaptation for neoadjuvant carbon ion therapy (CIRT) of pancreatic cancer. MATERIAL/METHODS: For 10 previously treated patients, 4DCTs were acquired around -15 (CTPlan), -5 (RE1), -1 (RE2) and +6 (RE3) days from RT start. Treatment plans were newly optimized to a dose prescription of 38.4 Gy(RBE) (8 fractions) with a constraint of 38 Gy(RBE) to 1% of the gastrointestinal organs at risk volume (D1%). Three strategies were tested: (A) robust optimization on CTPlan maximum exhale (0Ex) with 3 mm set-up, 3% range uncertainty, including 30%-inhale; (B) addition of the RE1-0Ex scenario; (C) plan recalculation at each REi and adaptation (RPi) according to deviation thresholds from clinical goals. The cumulative variation of target coverage and GI-OARs doses was evaluated. Duodenum contours of all 4DCTs of each patient were registered on CTPlan-0Ex. The capacity of pre-RT acquisitions to predict duodenum position was investigated by computing the intersection of contours at CTplan, RE1, or their union, with respect to subsequent 4DCTs and the CTV, coupled with increasing margin. RESULTS: (A) No recalculation exceeded the D1% constraint. (B) The inclusion of RE1-0Ex in the optimization problem improved inter-fraction robustness on a patient-specific basis, but was non-significant on average. (C) Half of the plans would be re-optimized to recover target coverage and/or minimize duodenum dose, at least once. A significant difference was observed between pre-RT duodenum contours when intersecting subsequent contours, either with a margin expansion. CONCLUSION: Anatomical variations highlighted at multiple REi proved that a fast and efficient online adaptation is essential to optimize treatment quality of CIRT for pancreatic cancer.


Asunto(s)
Radioterapia de Iones Pesados , Neoplasias Pancreáticas , Terapia de Protones , Radioterapia de Intensidad Modulada , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Órganos en Riesgo , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/radioterapia , Radioterapia de Intensidad Modulada/métodos , Terapia de Protones/métodos , Neoplasias Pancreáticas
18.
Radiol Med ; 127(9): 1046-1058, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35871428

RESUMEN

The number of oncological patients who may benefit from proton beam radiotherapy (PBT) or carbon ion radiotherapy (CIRT), overall referred to as particle radiotherapy (RT), is expected to strongly increase in the next future, as well as the number of cardiological patients requiring cardiac implantable electronic devices (CIEDs). The management of patients with a CIED requiring particle RT deserves peculiar attention compared to those undergoing conventional photon beam RT, mostly due to the potential generation of secondary neutrons by particle beams interactions. Current consensus documents recommend managing these patients as being at intermediate/high risk of RT-induced device malfunctioning regardless of the dose on the CIED and the beam delivery method used, despite the last one significantly affects secondary neutrons generation (very limited neutrons production with active scanning as opposed to the passive scattering technique). The key issues for the current review were expressed in four questions according to the Population, Intervention, Control, Outcome criteria. Three in vitro and five in vivo studies were included. Based on the available data, PBT and CIRT with active scanning have a limited potential to interfere with CIED that has only emerged from in vitro study so far, while a significant potential for neutron-related, not severe, CIED malfunctions (resets) was consistently reported in both clinical and in vitro studies with passive scattering.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Electrónica , Humanos , Protones , Estudios Retrospectivos
19.
Cancers (Basel) ; 14(11)2022 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-35681661

RESUMEN

(1) Background: In this work, we aim to provide selection criteria based on normal tissue complication probability (NTCP) models and additional explanatory dose-volume histogram parameters suitable for identifying locally advanced sinonasal cancer patients with orbital invasion benefitting from proton therapy. (2) Methods: Twenty-two patients were enrolled, and two advanced radiation techniques were compared: intensity modulated proton therapy (IMPT) and photon volumetric modulated arc therapy (VMAT). Plans were optimized with a simultaneous integrated boost modality: 70 and 56 Gy(RBE) in 35 fractions were prescribed to the high risk/low risk CTV. Several endpoints were investigated, classified for their severity and used as discriminating paradigms. In particular, when NTCP models were already available, a first selection criterion based on the delta-NTCP was adopted. Additionally, an overall analysis in terms of DVH parameters was performed. Furthermore, a second selection criterion based on a weighted sum of the ΔNTCP and ΔDVH was adopted. (3) Results: Four patients out of 22 (18.2%) were suitable for IMPT due to ΔNTCP > 3% for at least one severe toxicity, 4 (18.2%) due to ΔNTCP > 20% for at least three concurrent intermediate toxicities and 16 (72.7%) due to the mixed sum of ΔNTCP and ΔDVH criterion. Since, for some cases, both criteria were contemporary fulfilled, globally 17/22 patients (77.3%) would benefit from IMPT. (4) Conclusions: For this rare clinical scenario, the use of a strategy including DVH parameters and NTCPs when comparing VMAT and IMPT is feasible. We showed that patients affected by sinonasal cancer could profit from IMPT compared to VMAT in terms of optical and central nervous system organs at risk sparing.

20.
Front Cardiovasc Med ; 9: 849247, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35600462

RESUMEN

Background: Cardiac arrhythmias, such as ventricular tachycardia, are disruptions in the normal cardiac function that originate from problems in the electrical conduction of signals inside the heart. Recently, a non-invasive treatment option based on external photon or proton beam irradiation has been used to ablate the arrhythmogenic structures. Especially in proton therapy, based on its steep dose gradient, it is crucial to monitor the motion of the heart in order to ensure that the radiation dose is delivered to the correct location. Transthoracic ultrasound imaging has the potential to provide guidance during this treatment delivery. However, it has to be noted that the presence of an ultrasound probe on the chest of the patient introduces constraints on usable beam angles for both protons and photon treatments. This case report investigates the possibility to generate a clinically acceptable proton treatment plan while the ultrasound probe is present on the chest of the patient. Case: A treatment plan study was performed based on a 4D cardiac-gated computed tomography scan of a 55 year-old male patient suffering from refractory ventricular tachycardia who underwent cardiac radioablation. A proton therapy treatment plan was generated for the actual treatment target in presence of an ultrasound probe on the chest of this patient. The clinical acceptability of the generated plan was confirmed by evaluating standard target dose-volume metrics, dose to organs-at-risk and target dose conformity and homogeneity. Conclusion: The generation of a clinically acceptable proton therapy treatment plan for cardiac radioablation of ventricular tachycardia could be performed in the presence of an ultrasound probe on the chest of the patient. These results establish a basis and justification for continued research and product development for ultrasound-guided cardiac radioablation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA