Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Arthroplast Today ; 28: 101464, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39100416

RESUMEN

Background: Tibiofemoral components rotational congruency affects the total knee arthroplasty (TKA) success. The smart insert sensor (I-S) helps to establish tibial component rotation reciprocally to a fixed femoral rotation. We aimed (1) to validate the use of I-S as a possible tool to reach reproducible reciprocal femorotibial rotation (RftR) in TKA independently from anatomic landmarks, reducing outliers in combined and mismatched femorotibial rotation (CftR and MMftR, respectively) positioning and (2) to validate the "curve-on-curve" method for a specific type of asymmetrical tibial component. Methods: From February 2018, we conducted a prospective case-control study including 106 patients undergoing TKA. Patients were divided into 2 groups based on the method used to establish tibial component rotation: with the I-S use (group A, n = 53) and with the standard "curve-on-curve" technique (group B, n = 53). Rotational alignment was calculated using the Berger protocol with postoperative computed tomography scanning. Alignment parameters measured were tibial and femoral component rotations (tR, fR), the CftR, the MMftR, and the RftR. Results: Intraoperative rotation measured by I-S correlated the best with RftR (r = 0.84; P < .001) at the post-operative CT scanning. No significant differences were found between groups A and B regarding all types of rotation (fR: P = .774; tR: P = .467; CftR: P = .847) except for MMftR (P = .036) and RftR (P = .023). There were no outliers in group A but 27 and 12 outliers in group B for MMftR and CftR respectively (P < .001; P = .032). Conclusions: The TKA components' rotation established using a smart I-S intraoperatively is ascribable to the RftR at postoperative computed tomography scan. The I-S helps reduce outliers in the CftR and MMftR. An asymmetrical tibial base plate implanted using the curve-on-curve technique does not create a neutral reciprocal femorotibial rotation significantly increasing the number of cases with mismatched femorotibial internal rotation.

2.
Arthrosc Tech ; 13(6): 102826, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39036402

RESUMEN

Revision of anterior cruciate ligament reconstruction (ACL-R) presents many challenges that are not encountered in the primary setting and, therefore, requires thorough preoperative planning. Recently, there has been growing evidence showing that combining the anterolateral ligament (ALL) reconstruction with ACL-R revision reduces the risk of postoperative ACL rupture and meniscal tears, and therefore, the ALL reconstruction becomes essential to a complex ACL revision. The technique that we describe is mainly used in the setting of complex ACL revision with extensive tunnel osteolysis associated with rotational instability of the knee. This article presents a technique for a one-stage complex ACL-R revision combined with ALL reconstruction using an Achilles tendon allograft with a bone plug.

3.
Musculoskelet Surg ; 108(3): 339-345, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38967771

RESUMEN

BACKGROUND: We created a multicenter survey for Italian orthopedic surgeons on how they approach leg length discrepancy (LLD) when dealing with primary total hip arthroplasty. Aim of the study was to show how surgeons manage LLD and follow the literature recommendations during clinical practice. METHODS: The survey was composed of 25 questions divided into four sections: 1-surgeon's profile, 2-preoperative and 3-intraoperative evaluation, and 4-postoperative management. In this paper, we report results to answer Sects. 1 and 2. Absolute and relative frequencies of answers to Sects. 2 and 3 are reported. We divided the participants in subgroups based on the "surgeon's profile" and evaluated difference in the answers given. RESULTS: Absolute and relative frequencies demonstrate low agreement among participants in all phases of LLD management. We demonstrated a statistically significant difference based on the surgeon's profile regarding these questions: radiographic measure of LLD depending on working experience, p = 0.008; digital planning based on surgeons' age, p < 0.001, and workplace, p = 0.026; intraoperative anatomical landmarks based on numbers of procedures per year, p = 0.020; and use of intraoperative X-rays based on working experience, p = 0.002. CONCLUSIONS: LLD is a debated topic with no definitive recommendations. Many decisions still depend on tradition and surgeons' preference.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Diferencia de Longitud de las Piernas , Humanos , Diferencia de Longitud de las Piernas/etiología , Artroplastia de Reemplazo de Cadera/métodos , Italia , Cuidados Preoperatorios , Cuidados Intraoperatorios , Pautas de la Práctica en Medicina/estadística & datos numéricos , Cirujanos Ortopédicos , Femenino , Encuestas y Cuestionarios , Masculino
4.
J Knee Surg ; 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39084605

RESUMEN

The medial unicompartmental knee arthroplasty (mUKA) has been recognized as an excellent treatment for medial knee osteoarthritis. The posterior tibial slope (PTS) is measured radiographically with the intramedullary axis (IMA) to the tibial baseplate on the sagittal plane radiograph. However, in most computer-navigated or robotic mUKAs, the PTS is set from a transmalleolar axis (TMA).The PTS difference was evaluatedbetween the sagittal TMA and the sagittal IMA of patients undergoing a CT-based primary robotic-assisted mUKA.We retrospectively reviewed the preoperative computed tomography (CT) scans taken according to the MAKO system protocol (Stryker) of 67 patients undergoing mUKAs. We measured the angular difference between the IMA and the TMA in the sagittal plane.Using the TMA to set the PTS the estimation of the slope of the medial tibial plateau would increase by an average of 1.9 ± 3.2 degreescompared to the IMA. Furthermore, in nineknees, PTS was decreased.Tibial components implanted with the help of a CT scan-based preoperative planning MAKO will show an average of 1.9 degrees more than those measured on sagittal radiographs potentially of concern for knee kinematics. A universal language is needed to standardize the slope calculation and the respective reference axis used.

5.
Ann Jt ; 9: 20, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38690077

RESUMEN

Background and Objective: Proximal femoral replacement due to revision hip arthroplasty or catastrophic proximal femur fracture fixation failures with considerable proximal femur bone loss can lead to a substantial loss of function of the soft tissue around the hip and the abductor muscles in particular. Surgical techniques of gluteus medius repair and/or abductor mechanism reattachment/reconstruction are widely debated in the literature, but it is quite rarely dealt with in the context of megaprosthesis and femoral reconstruction, particularly in non-oncologic patients. The aim of this study is to present a narrative review of the literature on techniques for abductor reattachment in proximal femoral replacement for non-oncological reconstructions. Methods: MEDLINE, Embase, and Cochrane databases were searched by two researchers independently from inception until February 1st, 2023 (923 for MEDLINE and 963 for Embase; Cochrane is a composite of multiple databases and thus does not report a standard inception date). Articles examining proximal femoral reconstruction with megaprosthesis or allograft prosthesis were included. Studies concerning cadaver and oncologic patients were excluded. If the researchers failed to find an agreement on whether to include a study, the senior researcher would make a final decision in such cases. Data were extracted and stored, and qualitative synthesis was performed. Key Content and Findings: A total of 1,157 articles from MEDLINE, 11,187 articles from Embase, and 0 articles from Cochrane were identified. Of 12,344 articles, the structured screening process revealed 10 eligible trials. Four different types of abductor musculature reconstruction/reinsertion were identified. Conclusions: Multiple and complex revision hip arthroplasties as well as multiple surgical procedures for proximal femur fracture fixations failures may have a great impact on proximal femur bone stock condition and soft tissue preservation requiring the use of a proximal femur megaprosthesis. In such cases, the abductor mechanism reconstruction and/or reattachment is achievable with different techniques that can be resumed in four different groups: direct suture to the prosthesis, trochanteric sleeve osteotomy, muscle-to-muscle suture, and synthetic tube augmentation suture.

6.
Clin Interv Aging ; 19: 655-664, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38706637

RESUMEN

Purpose: Aim of the present study was to evaluate whether monitoring direct oral anticoagulant (DOAC) levels may improve management of anticoagulated patients who need surgery for hip fracture. Patients and Methods: A total of 147 out of 2231 (7.7%) patients with hip fracture admitted to a tertiary teaching hospital were on DOACs (group A), whereas 206 patients matched for age, sex, and type of fracture not on anticoagulant or P2Y12 platelet inhibitors were considered as control group (group B). Patients on DOACs were divided into two subgroups: A1 in which intervention was scheduled in relation to the last drug intake according to current guidelines, and A2 included patients in whom time of surgery (TTS) was defined according to DOAC levels. Neuraxial anesthesia was considered with DOAC levels <30 ng/mL, general anesthesia for levels in the range 30-50 ng/mL. Results and conclusions: TTS was significantly lower in controls than in DOAC patients: surgery within 48 hours was performed in 80.6% of group B versus 51% in group A (p<0.0001). In A2, 41 patients underwent surgery within 48 hours (56%) in comparison to 32 A1 patients (45.1%; p=0.03). TTS and length of hospitalization were on average 1 day lower in patients with assay of DOAC levels. Finally, 35/39 (89%) patients with DOAC levels <50 ng/mL had surgery within 48 hours (26 under neuraxial anesthesia, without any neurological complication, and 13 in general anesthesia). Conclusion: DOAC assay in patients with hip fracture may be useful for correct definition of time to surgery, particularly in patients who are candidates for neuraxial anesthesia. Two-thirds of patients with DOAC levels <50 ng/mL at 48 hours from last drug intake underwent uneventful neuraxial anesthesia, saving at least 24 hours in comparison to guidelines.


Asunto(s)
Anticoagulantes , Monitoreo de Drogas , Fracturas de Cadera , Humanos , Fracturas de Cadera/cirugía , Femenino , Masculino , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Monitoreo de Drogas/métodos , Administración Oral , Cuidados Preoperatorios/métodos , Tiempo de Internación , Anestesia General
7.
J Knee Surg ; 37(11): 804-811, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38677294

RESUMEN

Revision anterior cruciate ligament reconstruction (ACLR) is a challenging surgery occurring in 3 to 24% of primary reconstructions. A meticulous planning to study the precise size and location of both femoral and tibial bone tunnels is mandatory. The aim of the study was to evaluate the intra- and interoperator differences in the decision-making process between experienced surgeons after they were asked to make preoperative planning for ACL revision reconstruction with the use of both the computed tomography (CT) scan and a three-dimensional (3D)-printed model of the knee. Data collected from 23 consecutive patients undergoing revision of ACLR for graft failure at a single institute between September 2018 and February 2020 were prospectively reviewed. The double-blinded collected data were presented to three board-certificate attending surgeons. Surgeons were asked to decide whether to perform one-stage or two-stage revision ACLR based on the evaluation of the CT scan images and the 3D-printed custom-made models at two different rounds, T0 and T1, respectively, 7 days apart one from the other. Interoperator consensus following technical mistake was 52% at T0 and 56% at T1 using the CT scans, meanwhile concordance was 95% at T0 and 94% at T1 using the 3D models. Concordance between surgeons following new knee injury was 66% at T0 and 70% at T1 using CT scans, while concordance was 96% both at T0 and T1 using 3D models. Intraoperative variability using 3D models was extremely low: concordance at T0 and T1 was 98%. McNemar test showed a statistical significance in the use of 3D model for preoperative planning (p < 0.005). 3D-printed model reliability resulted to be higher compared with CT as intraoperator surgery technique selection was not modified throughout time from T0 to T1 (p < 0.005). The use of 3D-printed models had the most impact when evaluating femoral and tibial tunnels, resulting to be a useful instrument during preoperative planning of revision ACLR between attending surgeons with medium-high workflow.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Impresión Tridimensional , Reoperación , Tomografía Computarizada por Rayos X , Humanos , Femenino , Adulto , Modelación Específica para el Paciente , Masculino , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Estudios Prospectivos , Cirugía Asistida por Computador , Imagenología Tridimensional , Persona de Mediana Edad
8.
Eur J Orthop Surg Traumatol ; 34(4): 2121-2128, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38555541

RESUMEN

BACKGROUND AND PURPOSE: The aim of this study was to evaluate whether this system is associated with a reduced rate of failure and complications in patients treated for proximal femoral fractures with intramedullary nailing. MATERIALS AND METHODS: 742 Patients with AO-OTA 31-A intertrochanteric fractures were enrolled at a single Institution. Functional evaluation was assessed through the Functional Independence Measure (FIM™) instrument and Parker's New Mobility Score (NMS). Radiological follow-up included the degree of the reduction according to the Baumgartner criteria, the Tip-Apex Distance, and the shortening of the telescoping screws and its lateral protrusion. RESULTS: Pre-operative mean FIM™ and NMS were 4.3 (range 1-9) and 98.7 (range 22-126), respectively. At the 12-month follow-up the average FIM™ and NMS were 95.3 (range 22-126) and 3.7 (range 1-9), respectively. Mean shortening of the lag screws was 4.3 mm (range 1-8) and mean lateral protrusion was 1.7 mm (range 0-3). 3 Cases (0.70%) of non-consolidation requiring reoperation were recorded. 1 Case (0.24%) of these cases was also characterized by nail breakage. No case of cut-out has been reported at our follow-up. CONCLUSIONS: This dual telescoping nail system is effective and safe. The sliding of the telescoping screws within the barrel is able to decrease strain from the femoral head during weight bearing reducing the risk of cut-out.


Asunto(s)
Clavos Ortopédicos , Tornillos Óseos , Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/efectos adversos , Masculino , Femenino , Anciano , Fracturas de Cadera/cirugía , Fracturas de Cadera/diagnóstico por imagen , Estudios Retrospectivos , Anciano de 80 o más Años , Persona de Mediana Edad , Resultado del Tratamiento , Radiografía , Adulto , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología
9.
Eur J Orthop Surg Traumatol ; 34(1): 479-487, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37624410

RESUMEN

PURPOSE: The aim of this study was to evaluate the relationship between the Löwenstein Lateral view and the True Lateral view for the positioning of the cephalic hip screw, through a cadaveric study. MATERIALS AND METHODS: We placed two Kirschner wires in eight femur specimens using an Antero-Posterior view, Löwenstein Lateral view and True Lateral view. The distances between the Kirschner wires and the anterior, posterior, superior and inferior cortex were measured in all projections. The head of the femur was then sectioned, and the same macroscopic distances were measured. Finally, we could calculate the accuracy of the two radiographic lateral projections. RESULTS: When the Kirschner wire was placed in the center of the head using the Antero-Posterior and the True Lateral view, the accuracy of Antero-Posterior view was 0.9705 while the accuracy of True Lateral view and Löwenstein Lateral view was 1.1479 and 1.1584, respectively. When the Kirschner wire was placed superior on the Antero-Posterior and centrally on the True Lateral view, the accuracy of Antero-Posterior view was 0.9930 while the accuracy of True Lateral view and Löwenstein Lateral view was 1.1159 and 0.7224, respectively. CONCLUSION: When the Kirschner wire was positioned proximal in Antero-Posterior view and central in True Lateral view, only the True Lateral view showed high accuracy.


Asunto(s)
Fracturas del Fémur , Humanos , Fracturas del Fémur/cirugía , Tornillos Óseos , Fémur/cirugía , Extremidad Inferior , Cadáver , Fijación Interna de Fracturas
10.
Arthrosc Tech ; 12(11): e2093-e2098, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38094942

RESUMEN

Posterior cruciate ligament ruptures account for nearly 20% of knee ligament lesions. These may be either isolated or occur as part of multiligament injuries. In most of the cases, conservative treatment is recommended, but when operative treatment is required, this is technically demanding. Several posterior cruciate ligament reconstructive techniques have been described, but some concerns still remain regarding graft choice, tunnels position, visualization of the posterior compartment and graft fixation. We describe an arthroscopic all-inside technique using a single-bundle autologous quadriceps tendon with patellar bone block.

11.
J Clin Med ; 12(13)2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37445391

RESUMEN

(1) Background: Total Knee Arthroplasty (TKA) in patient with haemophilia (PWH) has usually been performed with the use of cobalt-chrome femoral and titanium tibial components, coupled with standard polyethylene (PE) inserts. The aim of this retrospective study was to evaluate the long-term outcomes and survival rates of TKA in a series of consecutive PWH affected by severe knee arthropathy at a single institution. (2) Methods: We followed 65 patients undergoing 91 TKA, implanted using the same implant, characterized by an oxidized zirconium femoral component, coupled with a titanium tibial component, and a highly crosslinked PE. At 1, 6, and 12 months; then every year for 5 years; and finally, every other 3 years, all patients were scored for pain (VAS), function (HJHS; KSS), ROM, and radiographic changes. Kaplan-Meier survivorship curves were used to calculate the implant survival rates. (3) Results: The mean follow-up was 12.3 years (4.2-20.6). All clinical and functional scores improved significantly from preoperatively to the latest follow-up (VAS: from 6.9 to 1.3; HJHS: from 13.4 to 1.9; KSS: from 19.4 to 79; ROM: from 42.4° to 83.6°). The overall survivorship of the implants was 97.5% at the latest follow-up. (4) Conclusions: The present series showed a high survival rate of specific implants potentially linked to the choice of an oxidized zirconium coupled with a highly crosslinked PE. We promote the use of modern implants in these patients in order to ensure long-lasting positive outcomes.

12.
Biomedicines ; 11(4)2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37189637

RESUMEN

Parathyroid hormone (PTH) is a hormone secreted by the parathyroid glands. Despite its well-known characterized anabolic and catabolic actions on the skeleton, the in vitro effects of PTH on skeletal muscle cells are limited and generally performed on animal models. The aim of this study was to evaluate the effects of a short impulse of PTH (1-84) on the proliferation and the differentiation of skeletal muscle satellite cells isolated from human biopsies. The cells were exposed for 30 min to different concentrations of PTH (1-84), from 10-6 mol/L to 10-12 mol/L. ELISA was used to assay cAMP and the myosin heavy-chain (MHC) protein. The proliferation was assayed by BrdU and the differentiation by RealTime-qPCR. A statistical analysis was performed by ANOVA followed by Bonferroni's test. No significant variations in cAMP and the proliferation were detected in the isolated cells treated with PTH. On the other hand, 10-7 mol/L PTH on differentiated myotubes has shown significant increases in cAMP (p ≤ 0.05), in the expression of myogenic differentiation genes (p ≤ 0.001), and in the MHC protein (p ≤ 0.01) vs. untreated controls. This work demonstrates for the first time the in vitro effects of PTH (1-84) on human skeletal muscle cells and it opens new fields of investigation in muscle pathophysiology.

13.
Geriatr Orthop Surg Rehabil ; 14: 21514593231170844, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37162810

RESUMEN

Introduction: Total hip arthroplasty (THA) performed for femoral neck fractures (FNFs) is becoming a more frequent treatment in the active elderly population. Since there is limited research available presenting clinical outcomes after THA using the anterior-based muscle sparing (ABMS) approach, the aim of this study was to compare this surgical approach to the direct lateral (DL) approach in patients treated by THA for FNFs. Materials and Methods: We retrospectively reviewed the data prospectively collected as a part of our "Hip Fracture Unit" and included 163 patients who underwent THA from January 2016 to January 2019 for acute displaced FNFs. Results: A total of 132 patients who completed a minimum 2-years follow up (69 in the ABMS group and 63 in DL group) were included. The ABMS group demonstrated significantly shorter time to reach milestone for hospital discharge (1.5 Days vs 2.1 days, P = .018), while no statistically significant differences were detected in peri-operative complications. At 3 months, the timed up and go test, the Harris Hip Score (HHS) and the Oxford ip Score (OHS) were significantly better (P = .024, .032 and .034, respectively) in the ABMS group compared to the DL group. No differences were found in functional outcomes (HHS and OHS) nor in complication rate at 6, 12 and 24 months. Discussion: This is one of the first studies to analyze functional results of THA performed for FNFs through an ABMS approach. Results are in line with those already present in the Literature. Conclusion: ABMS approach allows earlier mobilization and better early functional outcomes, compared to DL approach, in patients undergoing THA for acute displaced FNF. No differences are found after 6 months in functional results and complications rate.

15.
J Exp Orthop ; 10(1): 32, 2023 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-36961581

RESUMEN

PURPOSE: Robotic-assisted surgery has been recently introduced to improve biomechanical restoration, and thus better clinical and functional outcomes, after knee joint arthroplasty operations. Robotic-assisted uni-compartmental knee arthroplasty (UKA) aims indeed to improve surgical bone resection and alignment accuracy, optimized component positioning and knee balancing, relying on a series of calibration measurements performed during the surgery. These advantages focus therefore on improving the reproducibility of UKA surgeries, reducing (if not eliminating) eventual differences among high- and low-volume surgeons. The purpose of this study is to investigate and quantify the reproducibility of in-vivo measurements performed with a robotic system: the intra- and inter-observer variability of a series of measurements was therefore analyzed and compared among differently experienced operators. METHODS: Five patients were analyzed and underwent robotic-assisted UKA using a semi-active robotic system. Three different observers with different experience levels were involved to independently perform the measurements of two parameters of the preoperative knee (Hip-Knee-Ankle angle [HKAa], Internal-External Rotation) at different degrees of knee flexion. Inter-observer and intra-observer comparisons were performed. RESULTS: The average variability in the measurements obtained from the intra-observer and inter-observer comparisons were always < 0.68° for HKAa and < 2.59° for internal-external rotation, and the ICCs showed excellent agreement (> 0.75) for most cases and good agreement (> 0.60) in the remaining ones. CONCLUSION: This study demonstrated high reproducibility of the measurements obtainable in clinical environment with the robotic system. The inter-observer results furthermore showed that the level of confidence with the robotic system is not significantly influencing the measurement.

16.
J Arthroplasty ; 38(9): 1773-1778, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36822447

RESUMEN

BACKGROUND: Hip hemiarthroplasty dislocation is a devastating complication. Among other preoperative risk factors, acetabular morphology has been rarely studied. The purpose of the study was to evaluate the influence of preoperative native acetabular morphology on hemiarthroplasty dislocation. METHODS: We retrospectively reviewed 867 patients who underwent hip hemiarthroplasty for femoral neck fracture between January 1, 2014 and January 1, 2019. The 380 included patients were treated with an anterior-based muscle-sparing approach. The central-edge angle (CEA) and acetabular depth-to-width ratio (ADWR) of the fractured hip were measured preoperatively on the anteroposterior pelvic view. Receiver operating characteristic curves were performed to analyze the optimal cutoff for CEA and ADWR. Hemiarthroplasty dislocation occurred in 18 patients (4.7%), and the remaining 362 patients were used as the control group. RESULTS: No significant differences in terms of sex, age, dementia, neuromuscular disease, and body mass index were found between the 2 groups. The 18 patients who had a hip dislocation had significantly smaller mean CEA than the control group (P = .0001) (mean 36.1 ± 7.5° and 43.2 ± 5.6°, respectively) as well as ADWR (mean 34 ± 6 versus 37 ± 4, respectively) (P = .001). Using the receiver operating characteristic analysis, we report significant cutoffs of 38.5° for CEA (P = .0001) and 34.5 for the ADWR (P = .017). CONCLUSION: Higher rates of hemiarthroplasty dislocation were observed in patients who had a preoperative CEA of less than 38.5° and an ADWR of less than 34.5. Patients who have preoperative acetabular morphological risk factors for dislocation might be better candidates for a total hip arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Cuello Femoral , Hemiartroplastia , Luxación de la Cadera , Luxaciones Articulares , Humanos , Anciano , Estudios Retrospectivos , Hemiartroplastia/efectos adversos , Acetábulo/cirugía , Luxaciones Articulares/epidemiología , Luxaciones Articulares/etiología , Luxaciones Articulares/cirugía , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/complicaciones , Luxación de la Cadera/epidemiología , Luxación de la Cadera/etiología , Luxación de la Cadera/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos
17.
J Med Case Rep ; 16(1): 457, 2022 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-36494697

RESUMEN

BACKGROUND: The synovial chondromatosis is an uncommon proliferative metaplastic process of the synovial cells that can develop in any synovial joint. An isolated primary chondromatosis of the posterior compartment of the knee is uncommon and few cases are reported in literature. Our purpose is to describe a rare case of primary chondromatosis of the knee posterior compartment and report the arthroscopic loose bodies excision through a difficult posteromedial portal, avoiding the use of the accessory posterior portal, most commonly reported for approaching this disease. CASE PRESENTATION: We report a rare case of a 35-year-old Caucasian male patient with diagnosis of chondromatosis of the posterior knee compartment. The radiographs showed multiple loose bodies of the posterior compartment. The MRI revealed minimal synovial hypertrophy areas, multiple osteophytes in the intercondylar notch, and loose bodies in the posteromedial compartment. The CT allowed us to assess the bony structures, the morphology of the intercondylar notch, and the presence osteophytes of the medial and lateral femoral condyles. The CT images were crucial to plan how to reach the posterior compartments of the knee through a trans-notch passage. The patient underwent arthroscopic surgery using anteromedial, anterolateral, and posteromedial portals. The tunneling through the intercondylar osteophytes was performed to allow the arthroscope to pass trans-notch. To avoid additional accessory posterior portals, we used a 70° arthroscope to better explore the posterior knee compartment. The cartilage-like bodies were removed and synovectomy of the inflamed areas was performed. The clinical and radiological follow-up was 12 months and the patient showed excellent clinical outcomes, returning to his activities of daily living and sport activity. CONCLUSION: Our case report highlights the importance of the arthroscopic approach to treat synovial chondromatosis, despite the involvement of the posterior compartment of the knee. An optimal preoperative imaging allows to plan for the proper surgical procedure even in patients with severe osteoarthritis. Moreover, the adoption of an intercondylar notch tunneling and a 70° arthroscope can help surgeons to better explore the posterior knee compartment, avoiding an accessory posterior trans-septal portal. Therefore, a synovectomy of the inflamed foci may be useful to prevent recurrence.


Asunto(s)
Condromatosis Sinovial , Cuerpos Libres Articulares , Humanos , Masculino , Adulto , Actividades Cotidianas , Condromatosis Sinovial/diagnóstico por imagen , Condromatosis Sinovial/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Cuerpos Libres Articulares/diagnóstico por imagen , Cuerpos Libres Articulares/cirugía , Sinovectomía , Artroscopía/métodos
18.
J Orthop ; 34: 94-99, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36046757

RESUMEN

Introduction: Lesser trochanter (LT) fixation to restore the continuity of the posteromedial fragment using a cerclage wire has been reported to provide a more stable reduction in the treatment of unstable femoral neck fractures with LT involvement. However, LT fixation is not commonly performed due to the complications associated with the traditional monofilament cerclage metal wires. In this study, we investigate the clinical and radiological outcomes of a new technique for LT fixation in conjunction with Intramedullary (IM) fixation with nail and screws when compared to isolated IM fixation. The Sling Fixation Technique involves a new wiring technique and the use of a polymer-based cerclage cable characterized by iso-elastic properties that is hypothesized to provide better clinical and radiographic outcomes. Patients and methods: This prospective observational study included 30 patients who underwent proximal IM nailing from July 2019 to April 2020. Thirty consecutive patients (30) were assigned to 2 different treatment groups. Fifteen (15) patients were treated with the IM Nailing and Sling Fixation Technique and 15 with IM nailing only. Patients were comparable for demographic features, fracture pattern, age, gender and associated medical comorbidities. Clinical outcomes were analyzed in terms of time needed to achieve complete weight bearing, Harris hip score (HHS), Barthel Index (BI) and Radiographic Union Scale for Hip (RUSH). The follow-up period was one year. Results: Time for fracture healing and to achieve weight-bearing in the "Sling" group were shown to be significantly shorter than in the IM group. The Sling group showed furthermore better HHS, BI and RUSH scores when compared to the IM group at 1, 3, 6, and 12 months from the surgery. No complications such as wiring breakage, cut-outs, breakage or pullout of the fixation screws were observed; one case of heterotrophic ossification was reported. Conclusion: In cases of unstable intertrochanteric fractures of the proximal femur with lesser trochanter involvement, the Sling fixation technique using an isoelastic polymer-based wire showed superior results in terms of stability and consequently better clinical and radiographic outcomes than IM nailing only.

19.
Clin Interv Aging ; 17: 1163-1171, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35957924

RESUMEN

Background: In elderly patients with hip fracture, the prevalence of severe aortic stenosis (valve area <1 cm2) is close to 5%. Few studies have evaluated the prognostic role of aortic stenosis in hip fracture surgery and none has considered the effects of the postoperative setting (intensive care unit vs general ward) on clinical outcome. Purpose: The aim of the present study was to evaluate the factors affecting mortality in patients with severe aortic stenosis undergoing surgery for hip fracture. We also evaluated whether postoperative monitoring in the intensive care unit may affect the prognosis in comparison to return to the general ward after surgery. Patients and Methods: All 2274 patients referred for hip fracture to our tertiary teaching hospital between January 1 2015 and December 31 2019 were screened for the presence of severe aortic stenosis, defined by an aortic valve area <1.0 cm2. Results: The study included 66 patients (27 males, 39 females) with a mean±SD age of 85±7 years. The average time between trauma and surgery was 2.6±3 days. The mean aortic valve area was 0.74±0.15 cm2. Seven patients died during hospitalization (10.4%). Diabetes, having two or more comorbidities, a low degree of autonomy, heart failure, history of coronary artery disease, atrial fibrillation, postoperative delirium and pulmonary hypertension were associated with poorer outcome. In logistic multivariate analysis, the number of diseases and values of pulmonary artery pressure were the only independent factors related to mortality. In hospital mortality (12 and 9%, respectively) and complication rates were not statistically different between patients referred to the intensive care unit for postoperative monitoring and patients returned to the general ward after surgery. Conclusion: In patients undergoing hip fracture surgery, severe aortic stenosis is associated with high hospital mortality, and two or more comorbidities and pulmonary hypertension are associated with a worse prognosis. The postoperative setting (intensive care unit or general ward) does not affect outcome.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Fracturas de Cadera , Hipertensión Pulmonar , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Femenino , Fracturas de Cadera/complicaciones , Fracturas de Cadera/cirugía , Mortalidad Hospitalaria , Humanos , Hipertensión Pulmonar/complicaciones , Hipertensión Pulmonar/cirugía , Masculino , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
20.
Osteoporos Int ; 33(12): 2467-2478, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35851407

RESUMEN

Osteoporotic fractures are one of the major problems facing healthcare systems worldwide. Undoubtedly, fragility fractures of the hip represent a far greater burden in terms of morbidity, mortality, and healthcare costs than other fracture sites. However, despite the significant impact on the health and quality of life of older adults, there is a general lack of awareness of osteoporosis, which results in suboptimal care. In fact, most high-risk individuals are never identified and do not receive adequate treatment, leading to further fragility fractures and worsening health status. Furthermore, considering the substantial treatment gap and the proven cost-effectiveness of fracture prevention programs such as Fracture Liaison Services, urgent action is needed to ensure that all individuals at high risk of fragility fracture are adequately assessed and treated. Based on this evidence, the aim of our review was to (i) provide an overview and comparison of the burden and management of fragility fractures, highlighting the main gaps, and (ii) highlight the importance of using alternative approaches, both surgical and non-surgical, with the aim of implementing early prevention of osteoporotic fractures and improving the management of osteoporotic patients at imminent and/or very high risk of fracture.


Asunto(s)
Conservadores de la Densidad Ósea , Osteoporosis , Fracturas Osteoporóticas , Humanos , Anciano , Fracturas Osteoporóticas/prevención & control , Fracturas Osteoporóticas/cirugía , Calidad de Vida , Osteoporosis/complicaciones , Osteoporosis/terapia , Análisis Costo-Beneficio , Atención a la Salud , Prevención Secundaria , Conservadores de la Densidad Ósea/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA