Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 276
Filtrar
1.
Dent Mater ; 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38944559

RESUMEN

OBJECTIVE: To assess the influence of calcination process on the properties of minimally processed recycled 3Y-TZP, and to compare it with its commercial counterpart. METHODS: Non-milled 3Y-TZP waste was collected, fragmented and ball-milled to a granulometric < 5 µm. Half of the recycled powder was calcined at 900 °C. Recycled 3Y-TZP disks were uniaxially pressed and sintered to create two recycled groups: 1) Calcined and 2) Non-calcined to be compared with a commercial CAD/CAM milled 3Y-TZP. The microstructure of experimental groups was assessed through density (n = 6), scanning electron microscopy (n = 3) and energy-dispersive X-ray spectroscopy (n = 3); and the crystalline content was evaluated through X-ray diffraction (XRD) (n = 3). Optical and mechanical properties were investigated through reflectance tests (n = 10), and Vickers hardness, fracture toughness (n = 5), and biaxial flexural strength tests (n = 16), respectively. Fractographic analysis was performed to identify fracture origin and crack propagation. Statistical analyses were performed through ANOVA followed by Tukey´s test, and by Weibull statistics. RESULTS: Particle size distribution of recycled powder revealed an average diameter of ∼1.60 µm. The relative density of all experimental groups was > 98.15 % and XRD analysis exhibited a predominance of tetragonal-phase in both recycled groups, which were similar to the crystallographic pattern of the control group. Cross-section micrographs presented flaws on the non-calcined group, and a more homogeneous microstructure for the calcined and commercial groups. Commercial samples showed lower contrast-ratio and higher translucency-parameter than the recycled groups, where non-calcined presented higher translucency-parameter and lower contrast-ratio than its calcined counterpart. The commercial group presented higher fracture toughness and characteristic strength than the recycled groups. Moreover, the calcined group exhibited higher hardness, characteristic strength, and probability of survival at higher loads than the non-calcined group. Fractographic analysis depicted the presence of microstructural flaws in the non-calcined group, which may have acted as stress-raisers and led to failures at lower flexural strengths values. SIGNIFICANCE: The calcination process improved the microstructure, optical, and mechanical properties of the recycled 3Y-TZP.

3.
Toxicol In Vitro ; 98: 105847, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38759936

RESUMEN

Hydroxychloroquine (HCQ) is a safe antimalarial drug but its overdosage or inappropriate use, such as during the pandemic, may cause adverse effects once this drug is considered a potent inhibitor of autophagy. Information about HCQ's effects on the reproductive field, including gametes and initial embryos, is limited. In this study, we evaluated the effect of HCQ (1, 6, 12, and 24 µM) on pre-implantation embryo development, autophagy, and apoptosis of bovine embryos produced in vitro. A dose-response experiment showed a reduction (p < 0.05) in cleavage only at the highest concentration. Blastocyst rate was gradually reduced (p < 0.05) with the increase of HCQ dosage starting at 6 µM, with no embryo formation occurring at 24 µM. Further analysis showed that embryos treated with 12 µM of HCQ had a higher (p < 0.05) accumulation of acidic autophagic vesicles on Days 5 and 7 of development and a higher (p < 0.01) apoptotic index on Day 7. To our knowledge, this is the first study to evaluate the effects of HCQ on embryo pre-implantation development in mammals. The results contribute with more information related to the study of autophagy in embryology as well as add some discussion on HCQ toxicology and its effects on reproductive cells.


Asunto(s)
Apoptosis , Autofagia , Blastocisto , Desarrollo Embrionario , Hidroxicloroquina , Animales , Bovinos , Hidroxicloroquina/toxicidad , Desarrollo Embrionario/efectos de los fármacos , Autofagia/efectos de los fármacos , Apoptosis/efectos de los fármacos , Blastocisto/efectos de los fármacos , Femenino , Antimaláricos/toxicidad , Fertilización In Vitro , Técnicas de Cultivo de Embriones
4.
Nature ; 627(8002): 130-136, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38355793

RESUMEN

Genomic instability arising from defective responses to DNA damage1 or mitotic chromosomal imbalances2 can lead to the sequestration of DNA in aberrant extranuclear structures called micronuclei (MN). Although MN are a hallmark of ageing and diseases associated with genomic instability, the catalogue of genetic players that regulate the generation of MN remains to be determined. Here we analyse 997 mouse mutant lines, revealing 145 genes whose loss significantly increases (n = 71) or decreases (n = 74) MN formation, including many genes whose orthologues are linked to human disease. We found that mice null for Dscc1, which showed the most significant increase in MN, also displayed a range of phenotypes characteristic of patients with cohesinopathy disorders. After validating the DSCC1-associated MN instability phenotype in human cells, we used genome-wide CRISPR-Cas9 screening to define synthetic lethal and synthetic rescue interactors. We found that the loss of SIRT1 can rescue phenotypes associated with DSCC1 loss in a manner paralleling restoration of protein acetylation of SMC3. Our study reveals factors involved in maintaining genomic stability and shows how this information can be used to identify mechanisms that are relevant to human disease biology1.


Asunto(s)
Inestabilidad Genómica , Micronúcleos con Defecto Cromosómico , Animales , Humanos , Ratones , Cromosomas/genética , Daño del ADN , Inestabilidad Genómica/genética , Fenotipo , Sirtuina 1 , Mutaciones Letales Sintéticas
5.
Artículo en Inglés | MEDLINE | ID: mdl-38223952

RESUMEN

Summary: Background. Asthma control can be influenced by several factors, including obstructive sleep apnea (OSA). The literature reports variable prevalence and magnitude of OSA impact on asthma outcomes. The aim of our study is to analyze the frequency of high-risk for OSA in asthma patients and its impact on disease severity and control. Methods. We conducted a cross-sectional study at an Allergy Department with adult asthma patients recruited while undergoing routine lung function tests. Data on sex, age, body mass index, allergen sensitization, smoking habits, risk of OSA (using the Berlin questionnaire), rhinitis control (through CARAT), asthma severity (based on GINA 2023), asthma control (using the ACT), adherence to asthma treatment (through Treatment Adherence Measure) and pulmonary function test results were collected. Results. We included 216 patients, predominantly women (70.4%), with a median (P25-P75) age of 29.0 (21.0-45.0) years, of whom 28.2% were on GINA treatment levels 4-5. In 75.5% of cases asthma was controlled. High-risk for OSA was identified in 21.8% of patients. Asthma patients with high-risk for OSA were more likely to have uncontrolled [(47.8%; n = 22) vs (15.8%; n = 26); p less than 0.001] and more severe disease [(44.7%; n = 21) vs (23.7%; n = 40), p = 0.006]. In multivariable analysis, high-risk for OSA (OR 2.81 [95%CI 1.1.28-6.17], p = 0.010), sex (women) (OR 5.21 [95% CI 1.70-15.96], p = 0.004), uncontrolled rhinitis (OR 3.65 [95%CI 1.38-9.64], p = 0.009) and GINA asthma treatment steps 4-5 (OR 2.46 [95%CI 1.15-5.26], p = 0.020) were associated with uncontrolled asthma. Conclusions. It is crucial to actively investigate OSA, especially in patients with uncontrolled and more severe forms of asthma.

6.
Med Oral Patol Oral Cir Bucal ; 29(1): e103-e110, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37992144

RESUMEN

BACKGROUND: To evaluate bone regenerative capacity of cryoprotected corticocancellous allogeneic bone graft performed in type II and III post-extraction sockets for ridge preservation after twelve weeks in-vivo. MATERIAL AND METHODS: Twenty-seven type II or III bony-walled extraction sockets (mandible and maxilla) were selected for this study. Following atraumatic tooth-extraction a cryoprotected corticocancellous allogeneic bone graft material and a resorbable porcine-derived collagen membrane were used for ridge preservation. During re-entry surgery at approximately 12 weeks, bone core biopsies were obtained using a 3.2 mm trephine drill and samples were histologically processed and subjected to qualitative and quantitative histomorphometric analysis. Quantitative data was analyzed using a general linear mixed model with results presented as mean values with the corresponding 95% confidence interval values. RESULTS: Healing without incident and ridge preservation allowed for the placement of dental implants after 12 weeks in 25 out of the 27 treated socket sites. Analyses yielded an average of ~21.0±7% of old/native bone, ~17±5.5% of newly regenerated bone (total of ~38±12.8% for all bone), 0.23±0.14% of new bone presenting with nucleating sites within the matrix, ~52±5.12% of soft tissue, and 3.6±2.09% of damaged bone. The average regenerated bone was statistically analogous to that of old/native bone (p=0.355). Furthermore, an atypical histological pattern of bone regeneration was observed, with newly formed bone exhibiting "infiltration-like" behavior and with new bone nucleating sites observed within the demineralized bone matrix. CONCLUSIONS: Cryoprotected corticocancellous allogeneic bone-graft demonstrated osteoconductive, osteoinductive, and osteogenic properties, yielding unique healing patterns which does warrant further investigation.


Asunto(s)
Pérdida de Hueso Alveolar , Aumento de la Cresta Alveolar , Trasplante de Células Madre Hematopoyéticas , Animales , Porcinos , Alveolo Dental/cirugía , Aumento de la Cresta Alveolar/métodos , Regeneración Ósea , Cicatrización de Heridas , Extracción Dental , Trasplante Óseo/métodos , Pérdida de Hueso Alveolar/cirugía
7.
Artículo en Inglés | MEDLINE | ID: mdl-37992148

RESUMEN

BACKGROUND: Hierarchical micro-nano structured topography along with surface chemistry modifications of dental implants have been suggested to positively contribute to the osseointegration process. However, the effect of such surface modifications on the molecular response as well as bone formation rate and quality are still unclear, especially in the early healing period. This study aimed to evaluate the effect of coating a double acid etched (DAE) implant surface with nano-sized (20 nm) hydroxyapatite (Nano) with respect to gene expression, histologic parameters, and nanomechanical properties when compared to DAE control at 1 and 2 weeks after implant placement in a rodent femur model. MATERIAL AND METHODS: Expression of bone-related genes was determined by qRT-PCR (Col-I, Runx-2, Osx, Opn, Ocn, Alp). Histomorphometric evaluation of bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) within implant threads was performed using photomicrographs after histologic processing. Mechanical properties, reduced elastic modulus and hardness, were determined through nanoindentation. RESULTS: At 1 week, the Nano group demonstrated significantly higher expression of Col-I and Ocn compared to the DAE group, indicating upregulation of osteoprogenitor and osteoblast differentiation genes. At 2 weeks, Nano surface further exhibited enhanced gene expression of Col-I and Osx in comparison to the DAE surface, suggesting an increased mineralization of the newly formed bone. Nanoindentation analysis revealed that the Nano group presented no significant difference on the ranks of reduced elastic modulus and hardness compared to DAE for both timepoints. Histomorphometric analysis yielded no significant difference in the percentage of BIC and BAFO between the Nano and DAE surfaces at 1 and 2 weeks. However, Nano implants did present a higher mean value, ~50%, of BIC compared to DAE, ~30%, after 2 weeks in vivo. CONCLUSIONS: While no significant differences were observed in the amount and mechanical properties of newly formed bone, Nano surface positively and significantly increased the expression osteogenic genes compared to DAE surface at early healing periods.

8.
J Hazard Mater ; 455: 131649, 2023 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-37210879

RESUMEN

Environmental protection is a central concern regarding municipal solid waste incineration bottom ash (IBA) management, but the assessment of waste Hazardous Property HP14 (ecotoxicity) is still under debate. Civil engineering applications may be a suitable management strategy. This work aimed at evaluating IBA regarding mechanical behaviour and environmental hazardous potential, including a biotest battery for ecotoxicity assessment (comprising miniaturised tests), to explore its potential for safe utilization. Physical, chemical, ecotoxicological (Aliivibrio fischeri, Raphidocelis subcapitata, Lemna minor, Daphnia magna, Lepidium sativum), and mechanical (one-dimensional compressibility, shear strength) analyses were performed. The low leaching for potentially toxic metals and ions complied with European Union (EU) limit values for non-hazardous waste landfills. No relevant ecotoxicological effects were found. The biotest battery seems suitable for ecotoxicological assessment in the aquatic ecosystem, providing wide information on waste impact on different trophic/functional levels and chemical uptake routes, simultaneously involving short-duration tests and reduced amounts of waste. IBA presented more compressibility than sand, but its mixture with sand (30%:70%) was closer to sand compressibility. IBA (lower stresses) and the mixture (higher stresses) showed slightly higher shear strength than sand. Overall, IBA presented the potential for valorisation as loose aggregates from an environmental and mechanical viewpoint in a circular economy framework.


Asunto(s)
Ceniza del Carbón , Incineración , Ceniza del Carbón/química , Ecosistema , Arena , Unión Europea , Residuos Sólidos
9.
Artículo en Inglés | MEDLINE | ID: mdl-36975723

RESUMEN

Summary: Background. Drug hypersensitivity reactions are presumably immune-mediated reactions that cause reproducible signs and/or symptoms. Overdiagnosis of drug allergy, frequently self-reported, is common and carries significant limitations. We intended to analyze the frequency and impact of drug allergy in hospitalized patients. Methods. A retrospective study was conducted in an Internal Medicine ward at a tertiary hospital in Portugal. All patients with a drug allergy report admitted within a 3-year period were included. Data were collected from their electronic medical records. Results. We found that 15.4% of patients had a report of drug allergy, with antibiotics being the most common (56.4%), followed by non-steroidal anti-inflammatory drugs (21.7%) and radiocontrast media (7.0%). The allergy report affected the clinical approach of 14.5% of patients by motivating the use of second-line agents, or the eviction of necessary procedures. The usage of alternative antibiotics entailed a cost increase of 2.4 times. There were 14.7% of patients to whom the suspected drug was administered: 87.0% tolerated and 13.0% developed a reaction. Only 1.9% were referred to our Allergy and Clinical Immunology department and proceeded in their allergy study. Conclusions. In this study, a considerable number of patients had a drug allergy label on their records. This label contributed to an increase in the cost of treatment, or the avoidance of necessary exams. However, disregarding an allergy record may lead to potentially life-threatening reactions that proper risk assessment could avoid. Further investigation should always be part of the follow-up routine of these patients, and better articulation between departments should be encouraged.

10.
Oper Dent ; 48(1): 51-58, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36534034

RESUMEN

PURPOSE: To evaluate the effect of short curing time using a high-radiant emittance light on polymerization shrinkage vectors in different consistency bulk-fill composites (BFRCs) using micro-computed tomography. METHODS AND MATERIALS: Radiopaque zirconia fillers were homogeneously incorporated and functioned as radiopaque tracers into two regular-paste: TBFill (Tetric EvoCeram Bulk Fill) and TPFill (Tetric PowerFill), and two flowable (n=6): TBFlow (Tetric EvoFlow Bulk Fill) and TPFlow (Tetric PowerFlow) resin composites. Class I cavities (4 mm depth × 4 mm length × 4 mm width) were 3D-printed and filled in a single increment: TBFill and TBFlow were light-activated using a Bluephase Style 20i (10 seconds in high-mode); TPFill and TPFlow were light-activated using a Bluephase PowerCure (three seconds). The same adhesive system (Adhese Universal) was used for all groups. Microcomputed tomography scans were obtained before and after light-activation. Filler particle movement was identified by polymerization shrinkage vectors at five depths (from 0-4 mm): top, top-middle, middle, middle-bottom and bottom. RESULTS: TPFlow showed the lowest total vector displacement, followed by TBFlow, TBFill and TPFill, significantly different among each other (p<0.05). Generally, BFRCs showed decreased vector displacement with increased depth, and higher displacement at the top-surface (p<0.05). Qualitative analysis showed a similar pattern of vector magnitude and displacement for groups TBFill and TPFill, with displacement vectors on occlusal (top) surfaces toward the center of the restoration from the top to middle areas, and relatively limited displacement at the bottom. TBFlow and TPFlow showed more displacement on the occlusal (top). CONCLUSIONS: Short curing time with high-radiant emittance on fast-curing BFRCs was shown to be a feasible option in terms of vector displacement. Flowable BFRCs presented lower vector displacement than their regular-viscosity versions.


Asunto(s)
Resinas Compuestas , Caries Dental , Humanos , Microtomografía por Rayos X , Polimerizacion , Ensayo de Materiales , Curación por Luz de Adhesivos Dentales
11.
Med Oral Patol Oral Cir Bucal ; 28(1): e48-e55, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36173722

RESUMEN

BACKGROUND: Successful osseointegration of endosteal dental implants has been attributed to implant design, including the macro-, micro- and nano- geometric properties. Based on current literature pertaining to implant design, the resultant cellular and bone healing response is unknown when the thread thickness of the implants is increased, resulting in an increased contact area in implants designed with healing chambers. The aim of this study was to evaluate the effect of two implant designs with different thread profiles on the osseointegration parameters and implant stability at 3- and 6-weeks in vivo using a well-established preclinical dog model. MATERIAL AND METHODS: A total of 48 type V Ti alloy implants were divided in two groups according to their thread design (D1= +0.1x/mm and D2= +0.15x/mm) and placed in an interpolated fashion into the radii of six beagles. Insertion torque was measured at time of placement, radii were extracted for histological processing following 3- and 6-week healing intervals. Histologic and histomorphometric analyses were performed in terms of bone to implant contact (%BIC) and bone area fraction occupancy within implant threads (%BAFO). Statistical analyses were performed through a linear mixed model with fixed factors of time and implant thread design. RESULTS: Surface roughness analysis demonstrated no significant differences in Sa and Sq between D1 and D2 implant designs, which confirmed that both implant designs were homogenous except for their respective thread profiles. For insertion torque, statistically significant lower values were recorded for D1 in comparison to D2 (59.6 ± 11.1 and 78.9 ± 10.1 N⋅cm, respectively). Furthermore, there were no significant differences with respect to histological analysis and histomorphometric parameters, between D1 and D2 at both time points. CONCLUSIONS: Both thread profiles presented equivalent potential to successfully osseointegrate in the osteotomies, with D2 yielding higher mechanical retention upon placement without detrimental bone resorption.


Asunto(s)
Implantes Dentales , Oseointegración , Perros , Animales , Torque , Diseño de Prótesis Dental , Implantación Dental Endoósea/métodos , Propiedades de Superficie
12.
Med Oral Patol Oral Cir Bucal ; 27(5): e468-e475, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-35975804

RESUMEN

BACKGROUND: We aimed to histomorphometrically evaluate the effects of Leucocyte-Platelet-Rich Fibrin (L-PRF), with and without the combination of a bone grafting material, for alveolar ridge preservation using an in vivo canine model. MATERIAL AND METHODS: Seven dogs (Female Beagles, ~18-month-old) were acquired for the study. L-PRF was prepared from each individual animal by drawing venous blood and spinning them through a centrifuge at 408 RCF-clot (IntrasSpin, Intra-Lock, Boca Raton, FL). L-PRF membranes were obtained from XPression fabrication kit (Biohorizons Implant Systems, Inc., AL, USA). A split mouth approach was adopted with the first molar mesial and distal socket defects treated in an interpolated fashion of the following study groups: 1) Empty socket (negative control); 2) OSS filled defect 3) L-PRF membrane; and 4) Mix of Bio-Oss® with L-PRF. After six weeks, samples were harvested, histologically processed, and evaluated for bone area fraction occupancy (BAFO), vertical/horizontal ridge dimensions (VRD and HRD, respectively), and area of coronal soft tissue infiltration. RESULTS: BAFO was statistically lower for the control group in comparison to all treatment groups. Defects treated with Bio-Oss® were not statistically different then defects treated solely with L-PRF. Collapsed across all groups, L-PRF exhibited higher degrees of BAFO than groups without L-PRF. Defects filled with Bio-Oss® and Bio-Oss® with L-PRF demonstrated greater maintenance of VRD relative to the control group. Collapsed across all groups, Bio-Oss® maintained the VRD and resulted in less area of coronal soft tissue infiltration compared to the empty defect. Soft tissue infiltration observed at the coronal area was not statistically different among defects filled with L-PRF, Bio-Oss®, and Bio-Oss® with L-PRF. CONCLUSIONS: Inclusion of L-PRF to particulate xenograft did not promote additional bone heading at 6 weeks in vivo. However, we noted that L-PRF alone promoted alveolar socket regeneration to levels comparable to particulate xenografts, suggesting its potential utilization for socket preservation.


Asunto(s)
Regeneración Ósea , Fibrina Rica en Plaquetas , Alveolo Dental , Proceso Alveolar , Animales , Perros , Femenino , Leucocitos , Diente Molar , Extracción Dental , Alveolo Dental/cirugía
13.
Sci Rep ; 12(1): 10262, 2022 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-35715474

RESUMEN

Limited information is available about the effect of mid-pregnancy viral infections on the placental expression of efflux transporters and offspring behavior. We hypothesized that maternal exposure to polyinosinic-polycytidylic acid [poly(I:C)], a synthetic double-stranded RNA viral mimic, would impair placental cell turnover, the expression of selected ABC transporters and adult offspring behavior. C57BL/6 mice were administered poly(I:C) (10 mg/Kg;ip) or vehicle at gestational day (GD) 13.5 (mid-pregnancy). Dams were euthanized for blood collection 4 h after injection, fetal and placental collection at GD18.5 or allowed to deliver spontaneously at term. At GD 13.5, poly(I:C) induced an acute pro-inflammatory response characterized by an increase in maternal plasma levels of IL-6, CXCL-1 and CCL-2/MCP-1. At GD 18.5, poly(I:C) decreased cell proliferation/death in the labyrinthine and increased cell death in the junctional zones, characterizing a disruption of placental cell turnover. Abca1 and Abcg1 immunolabelling was decreased in the labyrinthine zone, whereas Abca1, Abcg1 and breast cancer resistance transporter (Bcrp) expression increased in the junctional zone. Moreover, adult offspring showed motor and cognitive impairments in the Rotarod and T-water maze tests. These results indicate that viral infection during mid-pregnancy may disrupt relevant placental efflux transporters, as well as placental cell turnover and offspring behavior in adult life.


Asunto(s)
Transportadoras de Casetes de Unión a ATP , Disfunción Cognitiva , Transportador de Casetes de Unión a ATP, Subfamilia G, Miembro 2/metabolismo , Transportadoras de Casetes de Unión a ATP/metabolismo , Animales , Disfunción Cognitiva/metabolismo , Femenino , Proteínas de Transporte de Membrana/metabolismo , Ratones , Ratones Endogámicos C57BL , Proteínas de Neoplasias/metabolismo , Placenta/metabolismo , Poli I-C/farmacología , Embarazo
14.
BMC Health Serv Res ; 22(1): 680, 2022 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-35597936

RESUMEN

BACKGROUND: The existing digital healthcare solutions demand a service development approach that assesses needs, experience, and outcomes, to develop high-value digital healthcare services. The objective of this study was to develop a digital transformation of the patients' follow-up service after cardiac surgery, based on a remote patient monitoring service that would respond to the real context challenges. METHODS: The study followed the Design Science Research methodology framework and incorporated concepts from the Lean startup method to start designing a minimal viable product (MVP) from the available resources. The service was implemented in a pilot study with 29 patients in 4 iterative develop-test-learn cycles, with the engagement of developers, researchers, clinical teams, and patients. RESULTS: Patients reported outcomes daily for 30 days after surgery through Internet-of-Things (IoT) devices and a mobile app. The service's evaluation considered experience, feasibility, and effectiveness. It generated high satisfaction and high adherence among users, fewer readmissions, with an average of 7 ± 4.5 clinical actions per patient, primarily due to abnormal systolic blood pressure or wound-related issues. CONCLUSIONS: We propose a 6-step methodology to design and validate a high-value digital health care service based on collaborative learning, real-time development, iterative testing, and value assessment.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Atención a la Salud , Estudios de Seguimiento , Humanos , Aprendizaje , Proyectos Piloto
15.
Med Oral Patol Oral Cir Bucal ; 27(2): e174-e180, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35218646

RESUMEN

BACKGROUND: The aim of the present study was to evaluate the effect of different concentrations of growth hormone (GH) on endosteal implant's surface at the early stages of osseointegration. MATERIAL AND METHODS: Sixty tapered acid-etched titanium implants were divided into four groups: i) Collagen, used as a control group; and three experimental groups, where after collagen coating, GH was administered directly to the surface in varying concentrations: ii) 0.265 mg, iii) 0.53 mg, and iv) 1 mg. Implants were placed in an interpolated fashion in the anterior flange of C3, C4 or C5 of 15 sheep with minimum distance of 6 mm between implants. After 3-, 6- and 12-weeks of healing samples were harvested, histologically processed, qualitatively and quantitatively assessed for bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). RESULTS: Statistical analysis as a function of time in vivo and coating resulted in no significant differences for BIC and BAFO at any evaluation time point. Histological evaluation demonstrated similar osseointegration features for all groups with woven bone formation at 3 weeks and progressive replacement of woven for lamellar bone in close contact with the implant surface and within the implant's threads. CONCLUSIONS: A single local application of growth hormone to the surface of titanium implants did not yield improved implant osseointegration independent of healing time.


Asunto(s)
Implantes Dentales , Oseointegración , Animales , Hormona del Crecimiento/farmacología , Ovinos , Propiedades de Superficie , Titanio/farmacología
16.
Med Oral Patol Oral Cir Bucal ; 26(6): e825-e833, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34564687

RESUMEN

BACKGROUND: The goal of this study was to evaluate hard tissue response following guided bone regeneration using commercially available bovine bone grafts and collagen membranes; bilayer collagen membrane and porcine pericardium-based membrane, by means of a non-destructive three-dimensional (3D) computerized volumetric analysis following microtomography reconstruction. MATERIAL AND METHODS: Bone regenerative properties of various bovine bone graft materials were evaluated in the Göttingen minipig model. Two standardized intraosseous defects (15mm x 8mm x 8mm) were created bilaterally of the mandible of eighteen animals (n=72 defects). Groups were nested within the same subject and randomly distributed among the sites: (i) negative control (no graft and membrane), (ii) bovine bone graft/bilayer collagen membrane (BOB) (iii) Bio-Oss® bone graft/porcine pericardium-based membrane (BOJ) and (iv) cerabone® bone graft/porcine pericardium-based membrane (CJ). Samples were harvested at 4, 8, and 12-week time points (n=6 animal/time point). Segments were scanned using computerized microtomography (µCT) and three dimensionally reconstructed utilizing volumetric reconstruction software. Statistical analyses were performed using IBM SPSS with a significance level of 5%. RESULTS: From a temporal perspective, tridimensional evaluation revealed gradual bone ingrowth with the presence of particulate bone grafts bridging the defect walls, and mandibular architecture preservation over time. Volumetric analysis demonstrated no significant difference between all groups at 4 weeks (p>0.127). At 8 and 12 weeks there was a higher percentage of new bone formation for control and CJ groups when compared to BOB and BOJ groups (p<0.039). The natural bovine bone graft group showed more potential for graft resorption over time relative to bovine bone graft, significantly different between 4 and 8 weeks (p<0.003). CONCLUSIONS: Volumetric analysis yielded a favorable mandible shape with respect to time through the beneficial balance between graft resorption/bone regenerative capacity for the natural bovine bone graft.


Asunto(s)
Sustitutos de Huesos , Animales , Bovinos , Regeneración Ósea , Sustitutos de Huesos/farmacología , Colágeno , Xenoinjertos , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Membranas Artificiales , Porcinos , Porcinos Enanos
17.
J Mech Behav Biomed Mater ; 123: 104690, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34385065

RESUMEN

OBJECTIVE: To characterize the effects of aging on the nanomechanical properties and 3D surface topographical parameters of an experimental Zirconia Toughened Alumina (ZTA) composite compared to its respective individual counterpart materials. METHODS: Disk-shaped specimens comprised of three material groups were processed: 1) ZTA 70/30 (70% alumina reinforced with 30% second-generation 3Y-TZP); 2) Zpex (Second-generation 3Y-TZP), and; 3) Al2O3 (High purity Alumina) (n = 10/material, 12 × 1 mm). After synthesis, ceramic powders were pressed, the green-body samples were sintered and polished. Nanoindentation testing was performed to record elastic modulus (E) and hardness (H). Interferometry was utilized to assess 3D surface roughness parameters (Sa, Sq), while X-ray diffraction (XRD) and scanning electron microscope (SEM) assessed the crystalline content and microstructure. All tests were performed before and after simulated aging (134°C, 2.2 bar, 20 h). Statistical analyses were performed using linear mixed-model and least square difference pos-hoc tests (α = 5%). RESULTS: XRD spectra indicated increase of monoclinic peaks for Zpex (~18%) relative to ZTA 70/30 (~2.5%) after aging. Additionally, aging did not affect the surface roughness parameters of ZTA 70/30 and Al2O3, although a significant increase in Sa was recorded for Zpex following aging (~90 nm) (p < 0.001). Al2O3 yielded the highest H and E values (H:21 GPa, E: 254 GPa), followed by ZTA 70/30 (H: 13 GPa, E: 214 GPa) and Zpex (H:11 GPa, E: 167 GPa), all significantly different (p < 0.03). CONCLUSION: ZTA 70/30 and Al2O3 presented high hydrothermal stability with respect to all evaluated variables, where artificial aging significantly increased the monoclinic content and surface roughness of Zpex.


Asunto(s)
Óxido de Aluminio , Itrio , Cerámica , Materiales Dentales , Ensayo de Materiales , Propiedades de Superficie , Circonio
18.
Sci Rep ; 11(1): 2429, 2021 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-33510337

RESUMEN

A correlated human red blood cell membrane fluctuation dependent on D-glucose concentration was found with dual time resolved membrane fluctuation spectroscopy (D-TRMFS). This new technique is a modified version of the dual optical tweezers method that has been adapted to measure the mechanical properties of red blood cells (RBCs) at distant membrane points simultaneously, enabling correlation analysis. Mechanical parameters under different D-glucose concentrations were obtained from direct membrane flickering measurements, complemented with membrane fluidity measurements using Laurdan Generalized Polarization (GP) Microscopy. Our results show an increase in the fluctuation amplitude of the lipid bilayer, and a decline in tension value, bending modulus and fluidity as D-glucose concentration increases. Metabolic mechanisms are proposed as explanations for the results.


Asunto(s)
Membrana Eritrocítica/fisiología , Glucosa/farmacología , Análisis Espectral , 2-Naftilamina/análogos & derivados , 2-Naftilamina/farmacología , Adulto , Fenómenos Biomecánicos , Membrana Eritrocítica/efectos de los fármacos , Humanos , Lauratos/farmacología , Fluidez de la Membrana/efectos de los fármacos , Procesamiento de Señales Asistido por Computador
19.
Dent Mater ; 36(12): e365-e374, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32943230

RESUMEN

OBJECTIVE: To evaluate the effect of aging on the microstructural, mechanical, and optical properties of an experimental zirconia-toughened alumina composite with 80%Al2O3 and 20%ZrO2 (ZTA Zpex) compared to a translucent zirconia (Zpex) and Alumina. METHODS: Disc-shaped specimens were obtained by uniaxial and isostatic pressing the synthesized powders (n = 70/material). After sintering and polishing, half of the specimens underwent aging (20 h, 134 °C, 2.2 bar). Crystalline content and microstructure were evaluated using X-ray diffraction and scanning electron microscopy, respectively. Specimens underwent biaxial flexural strength testing to determine the characteristic stress, Weibull modulus, and reliability. Translucency parameter (TP) and Contrast ratio (CR) were calculated to characterize optical properties. RESULTS: ZTA Zpex demonstrated a compact surface with a uniform dispersion of zirconia particles within the alumina matrix, and typical alumina and zirconia crystalline content. ZTA Zpex and alumina exhibited higher CR and lower TP than Zpex. ZTA Zpex and Zpex showed significantly higher characteristic stress relative to alumina. While aging did not affect optical and mechanical properties of ZTA Zpex and alumina, Zpex demonstrated a significant increase in translucency, as well as a in characteristic stress. Alumina reliability was significantly lower than others at 300 MPa, ZTA Zpex and Zpex reliability decreased at 800 MPa, except for aged Zpex. SIGNIFICANCE: While aging did not affect the mechanical nor the optical properties of ZTA Zpex and alumina, it did alter both properties of Zpex. The results encourage further investigations to engineer ZTA as a framework material for long span fixed dental prostheses specially where darkened substrates, such as titanium implant abutments or endodontically treated teeth, demand masking.


Asunto(s)
Óxido de Aluminio , Circonio , Cerámica , Materiales Dentales , Ensayo de Materiales , Reproducibilidad de los Resultados , Propiedades de Superficie
20.
Med Oral Patol Oral Cir Bucal ; 25(3): e311-e317, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32271322

RESUMEN

BACKGROUND: Modification of endosteal implants through surface treatments have been investigated to improve osseointegration. Boronization has demonstrated favorable mechanical properties, but limited studies have assessed translational, in vivo outcomes. This study investigated the effect of implant surface boronization on bone healing. MATERIAL AND METHODS: Two implant surface roughness profiles (acid etched, machined) in CP titanium (type II) alloy implants were boronized by solid-state diffusion until 10-15µm boron coating was achieved. The surface-treated implants were placed bilaterally into 5 adult sheep ilia for three and six weeks. Four implant groups were tested: boronized machined (BM), boronized acid-etched (BAA), control machined (CM), and control acid-etched (CAA). Osseointegration was quantified by calculating bone to implant contact (BIC) and bone area fraction occupancy (BAFO). RESULTS: Both implant types treated with boronization had BIC values not statistically different from machined control implants at t=3 weeks, and significantly less than acid-etched control (p<0.02). BAFO values were not statistically different for all 3-week groups except machined control (significantly less at p <0.02). BAFO had a significant downward trend from 3 to 6 weeks in both boronized implant types (p<0.03) while both control implant types had significant increases in BIC and BAFO from 3 to 6 weeks. CONCLUSIONS: Non-decalcified histology depicted intramembranous-like healing/remodeling in bone for controls, but an absence of this dynamic process in bone for boronized implants. These findings are inconsistent with in vitro work describing bone regenerative properties of elemental Boron and suggests that effects of boron on in vivo bone healing warrant further investigation.


Asunto(s)
Implantes Dentales , Oseointegración , Animales , Regeneración Ósea , Implantación Dental Endoósea , Diseño de Prótesis Dental , Ovinos , Propiedades de Superficie , Titanio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...