1.
Int J Cardiol ; 408: 132112, 2024 Aug 01.
Article En | MEDLINE | ID: mdl-38697399

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is an alternative to conventional surgery to treat severe mitral disease but its use is limited by the risk of left ventricular outflow tract obstruction (LVOTO). Screening depends on ECG-gated computed tomography (CT) that is not widely available and requires contrast. We developed and validated a transthoracic echocardiographic (TTE) method to assess the risk of LVOTO after TMVR with the Tendyne System. METHODS: We measured the LVOT longitudinal area on preoperative TTE dataset of patients screened for TMVR. The LVOT was measured as the box-area included by the aortic valve annulus, the anterior mitral leaflet (AML), the c-septum distance line, and the respective length of the AML on the interventricular septum. We analyzed the correlation between the TTE LVOT-box and the CT-measured neoLVOT area. Prediction performance for eligible patients was tested with ROC curves. RESULTS: Thirty-nine patients were screened, out of 14 patients (36%) not eligible for TMVR, 8 had risk of LVOTO. We found a linear correlation between the TTE LVOT-box and the CT-measured Neo-LVOT (r = 0.6, p = 0.002). ROC curve showed that the method is specific and sensitive and the cut-off value of the measure LVOT-box is 350 mm2. CONCLUSIONS: The proposed method is reliable to evaluate the risk of LVOTO after TMR with the Tendyne System. It is quick and easy and can be used as a first-line assessment in the outpatient clinic. Patients with LVOT-box <350 mm2 should not be further screened with ECG-gated cardiac CT.


Echocardiography , Ventricular Outflow Obstruction , Humans , Female , Male , Echocardiography/methods , Aged , Risk Assessment/methods , Ventricular Outflow Obstruction/diagnostic imaging , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Middle Aged , Retrospective Studies , Cardiac Catheterization/methods , Aged, 80 and over , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery
3.
Ann Cardiothorac Surg ; 13(2): 146-154, 2024 Mar 29.
Article En | MEDLINE | ID: mdl-38590988

The onset of atrial fibrillation (AF) has a direct association with left atrial appendage (LAA) function, as demonstrated by recent studies demonstrating the link between left atrial (LA) wall fibrosis, impaired contractility, and the development of AF. Non-valvular AF (NVAF) affects almost 30 million people worldwide, with this number expected to increase in the next 20 years. It is the main cause of ischemic stroke, with significant subsequent economic and social impact. Currently, the mainstay of stroke prevention in patients with NVAF is oral anticoagulation (OAC), which reduces the incidence of ischemic events at the stake of increased hemorrhagic events. Despite the introduction and widespread use of direct oral anticoagulants (DOACs), which almost completely replaced vitamin K antagonists (VKAs), the adherence to OAC is still low, hindering the efficacy of stroke prevention. Percutaneous LAA occlusion (LAAO) is now indicated (class IIB) in patients with NVAF at increased ischemic risk who cannot undergo OAC. Recently published data demonstrated that a reduced dose of DOAC after percutaneous LAAO is superior to long-term dual antiplatelet therapy (DAPT) for stroke prevention in the mid-term. One of the possible pitfalls of percutaneous LAAO is postprocedural peri-device leaks (PDLs) that have been associated with increased thromboembolic events. According to LAAOS III results, surgical LAAO during cardiac surgery brings a 33% reduction in risk of stroke at five years, independently from the OAC regimen with a high rate of complete appendage occlusion. The combination of surgical LAAO and reduced dose DOAC might ensure adequate embolic prevention, lowering the hemorrhagic risk. The present manuscript aims to describe the rationale and design of the Minimally Invasive Left Atrial Appendage Occlusion Plus REduced Dose DOAC To Prevent Stroke In Patients With Atrial Fibrillation Randomized Clinical Trial (LAAO-PlusRE).

4.
J Clin Med ; 13(6)2024 Mar 10.
Article En | MEDLINE | ID: mdl-38541805

Background: An unexplained condition that follows transcatheter aortic valve implantation (TAVI) is platelet count reduction (PR). According to published research, patients with balloon-expandable valves (BEVs) had a greater PR than those with self-expandable valves (SEVs). Objectives: The purpose of this study was to investigate the incidence and clinical effects of PR following TAVI. Methods: In total, 1.122 adult TAVI patients were enrolled. Propensity score matching was carried out in a 1:1 ratio between patients with BEVs and those with SEVs. The analysis included changes in platelet count, in-hospital mortality, and early postoperative adverse events. Results: Notably, 632 patients were matched (BEV:316; SEV:316). All patients' post-procedural platelet counts changed according to a parabolic curve, using a mixed regression model for repeated analyses (estimate = -0.931; standard error = 0.421; p = 0.027). The platelet count varied comparably in patients with BEVs and SEVs (estimate = -4.276, standard error = 4.760, p = 0.369). The average time for obtaining the nadir platelet count value was three days after implantation (BEV: 146 (108-181) vs. SEV: 149 (120-186); p = 0.142). Overall, 14.6% of patients (92/632) had post-procedural platelet count <100,000/µL. There was no difference between the two prosthesis types (BEV:51/316; SEV:41/316; p = 0.266). Thrombocytopenia was found to be significantly linked to blood product transfusions, lengthier stays in the intensive care unit and hospital, and in-hospital mortality. Conclusions: TAVI, irrespective of the type of implanted valve, is linked to a significant but temporary PR. Thrombocytopenia increases the risk of serious complications and in-hospital death in TAVI patients. To explore and clarify the causes and associated effects, further prospective research is necessary.

5.
Circulation ; 149(15): 1172-1182, 2024 Apr 09.
Article En | MEDLINE | ID: mdl-38410954

BACKGROUND: Recent guidelines redefined exercise pulmonary hypertension as a mean pulmonary artery pressure/cardiac output (mPAP/CO) slope >3 mm Hg·L-1·min-1. A peak systolic pulmonary artery pressure >60 mm Hg during exercise has been associated with an increased risk of cardiovascular death, heart failure rehospitalization, and aortic valve replacement in aortic valve stenosis. The prognostic value of the mPAP/CO slope in aortic valve stenosis remains unknown. METHODS: In this prospective cohort study, consecutive patients (n=143; age, 73±11 years) with an aortic valve area ≤1.5 cm2 underwent cardiopulmonary exercise testing with echocardiography. They were subsequently evaluated for the occurrence of cardiovascular events (ie, cardiovascular death, heart failure hospitalization, new-onset atrial fibrillation, and aortic valve replacement) during a follow-up period of 1 year. Findings were externally validated (validation cohort, n=141). RESULTS: One cardiovascular death, 32 aortic valve replacements, 9 new-onset atrial fibrillation episodes, and 4 heart failure hospitalizations occurred in the derivation cohort, whereas 5 cardiovascular deaths, 32 aortic valve replacements, 1 new-onset atrial fibrillation episode, and 10 heart failure hospitalizations were observed in the validation cohort. Peak aortic velocity (odds ratio [OR] per SD, 1.48; P=0.036), indexed left atrial volume (OR per SD, 2.15; P=0.001), E/e' at rest (OR per SD, 1.61; P=0.012), mPAP/CO slope (OR per SD, 2.01; P=0.002), and age-, sex-, and height-based predicted peak exercise oxygen uptake (OR per SD, 0.59; P=0.007) were independently associated with cardiovascular events at 1 year, whereas peak systolic pulmonary artery pressure was not (OR per SD, 1.28; P=0.219). Peak Vo2 (percent) and mPAP/CO slope provided incremental prognostic value in addition to indexed left atrial volume and aortic valve area (P<0.001). These results were confirmed in the validation cohort. CONCLUSIONS: In moderate and severe aortic valve stenosis, mPAP/CO slope and percent-predicted peak Vo2 were independent predictors of cardiovascular events, whereas peak systolic pulmonary artery pressure was not. In addition to aortic valve area and indexed left atrial volume, percent-predicted peak Vo2 and mPAP/CO slope cumulatively improved risk stratification.


Aortic Valve Stenosis , Atrial Fibrillation , Heart Failure , Humans , Middle Aged , Aged , Aged, 80 and over , Prognosis , Echocardiography, Stress/methods , Atrial Fibrillation/diagnosis , Atrial Fibrillation/complications , Prospective Studies , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Cardiac Output , Heart Failure/complications , Oxygen
6.
Article En | MEDLINE | ID: mdl-38327179

BACKGROUND AND AIMS: Mechanical complications (MCs) are rare but potentially fatal sequelae of acute myocardial infarction (AMI). Surgery, though challenging, is considered the treatment of choice. The authors sought to study early and long-term results of patients undergoing surgical treatment for post-AMI MCs. METHODS: Patients undergone surgical treatment for post-infarction MCs between 2001 through 2019 in 27 centers worldwide were retrieved from the database of CAUTION study. In-hospital and long-term mortality were the primary outcomes. Cox proportional hazards regression models were used to determine independent factors associated with overall mortality. RESULTS: The study included 720 patients. The median age was 70.0 [62.0-77.0] years, with a male predominance (64.6%). The most common MC encountered was ventricular septal rupture (VSR) (59.4%). Cardiogenic shock was seen on presentation in 56.1% of patients. In-hospital mortality rate was 37.4%; in more than 50% of cases, the cause of death was low cardiac output syndrome (LCOS). Late mortality occurred in 133 patients, with a median follow-up of 4.4 [1.0-8.6] years. Overall survival at 1, 5 and 10 years was 54.0%, 48.1% and 41.0%, respectively. Older age (p < 0.001) and postoperative LCOS (p < 0.001) were independent predictors of overall mortality. For hospital survivors, 10-year survival was 65.7% and was significant higher for patients with VSR than those with papillary muscle rupture (long-rank P = 0.022). CONCLUSIONS: Contemporary data from a multicenter cohort study show that surgical treatment for post-AMI MCs continues to be associated with high in-hospital mortality rates. However, long-term survival in patients surviving the immediate postoperative period is encouraging.Trial registration number: NCT03848429.

7.
J Thorac Cardiovasc Surg ; 167(1): 152-154, 2024 01.
Article En | MEDLINE | ID: mdl-35570018
8.
J Clin Med ; 12(23)2023 Nov 29.
Article En | MEDLINE | ID: mdl-38068466

Background: Platelet count reduction (PR) is a common but unclear phenomenon that occurs after aortic bioprosthesis valve implantation (bio-AVR). This study aimed to investigate the occurrence and clinical impact of PR in patients receiving stented, rapid deployment (RDV), or stentless bioprostheses. Methods: 1233 adult bio-AVR patients were enrolled. Platelet count variation, early post-operative adverse events, and in-hospital mortality were analysed. Results: 944 patients received a stented valve, an RDV was implanted in 218 patients, and 71 patients had a stentless bioprosthesis. In all groups, the platelet count at discharge was lower than the baseline values (p < 0.001). The percentage of PR was 27% in the stented group, 56% in the RDV group, and 55% in the stentless group. A higher platelet reduction, reaching the minimum platelet value, was observed in the RDV (mean: -30.84, standard error (SE): 5.91, p < 0.001) and stentless (mean: 22.54, SE: 9.10, p = 0.03) groups compared to the stented group. A greater PR occurred as the size of the bioprosthesis increased in RDV (p = 0.01), while platelet count variation was not directly proportional to the stented bioprosthesis size (p < 0.001). PR was not affected by cardiopulmonary bypass (mean: -0.00, SE: 0.001, p = 0.635) or cross-clamp (mean: -0.00, SE: 0.002, p = 0.051) times in any of the groups. RDV subjects experienced more in-hospital adverse events. PR was found to be associated with ischemic strokes in the overall population. Conclusions: Bio-AVR is associated with significant but transient PR. RDV patients more likely experience significant PR and related adverse clinical events. PR is associated with ischemic strokes, regardless of the bioprosthesis type.

9.
Front Immunol ; 14: 1210098, 2023.
Article En | MEDLINE | ID: mdl-37426661

Introduction: Preformed antibodies against αGal in the human and the presence of αGal antigens on the tissue constituting the commercial bioprosthetic heart valves (BHVs, mainly bovine or porcine pericardium), lead to opsonization of the implanted BHV, leading to deterioration and calcification. Murine subcutaneous implantation of BHVs leaflets has been widely used for testing the efficacy of anti-calcification treatments. Unfortunately, commercial BHVs leaflets implanted into a murine model will not be able to elicit an αGal immune response because such antigen is expressed in the recipient and therefore immunologically tolerated. Methods: This study evaluates the calcium deposition on commercial BHV using a new humanized murine αGal knockout (KO) animal model. Furtherly, the anti-calcification efficacy of a polyphenol-based treatment was deeply investigated. By using CRISPR/Cas9 approach an αGal KO mouse was created and adopted for the evaluation of the calcific propensity of original and polyphenols treated BHV by subcutaneous implantation. The calcium quantification was carried out by plasma analysis; the immune response evaluation was performed by histology and immunological assays. Anti-αGal antibodies level in KO mice increases at least double after 2 months of implantation of original commercial BHV compared to WT mice, conversely, the polyphenols-based treatment seems to effectively mask the antigen to the KO mice's immune system. Results: Commercial leaflets explanted after 1 month from KO mice showed a four-time increased calcium deposition than what was observed on that explanted from WT. Polyphenol treatment prevents calcium deposition by over 99% in both KO and WT animals. The implantation of commercial BHV leaflets significantly stimulates the KO mouse immune system resulting in massive production of anti-Gal antibodies and the exacerbation of the αGal-related calcific effect if compared with the WT mouse. Discussion: The polyphenol-based treatment applied in this investigation showed an unexpected ability to inhibit the recognition of BHV xenoantigens by circulating antibodies almost completely preventing calcific depositions compared to the untreated counterpart.


Bioprosthesis , Calcinosis , Animals , Swine , Cattle , Humans , Mice , Mice, Knockout , Antibody Formation , Bioprosthesis/adverse effects , Calcium , Antigens , Heart Valves , Models, Animal , Antibodies
10.
Antibiotics (Basel) ; 12(7)2023 Jul 14.
Article En | MEDLINE | ID: mdl-37508286

Aspergillus endocarditis represents the second etiological cause of prosthetic endocarditis following Candida spp. On the other hand, native-valve endocarditis due to Aspergillus are anecdotally reported with increasing numbers in the last decade due to new diagnostic technologies such as polymerase chain reaction (PCR) on samples like valve tissue or entire blood. We performed a review of the literature presenting one case report observed at Pisa University Hospital. Seventy-four case reports have been included in a period between 1950-2022. Immunocompromised status (patients with solid tumor/oncohematological cancer or transplanted patients) was confirmed to be the main risk factor for this rare opportunistic infection with a high rate of metastatic infection (above all, central nervous system) and mortality. Diagnosis relies on serum galactomannan and culture with PCR on valve tissue or whole blood. Cardiac surgery was revealed to be a life-saving priority as well as appropriate antifungal therapy including b-liposomal amphotericin or new triazoles (isavuconazole). The endocarditis team, facing negative blood culture endocarditis affecting an immunocompromised patient, should investigate this difficult-to-treat pathogen.

11.
Front Cardiovasc Med ; 10: 1120323, 2023.
Article En | MEDLINE | ID: mdl-37255710

The Neochord procedure is a viable option to treat degenerative mitral valve regurgitation in selected patients. Left ventricle reverse remodeling can cause neochord-relative elongation and reprolapse of the treated leaflet, leading to failure. We present a clinical case of extensive ventricle reverse remodeling after neochord implantation and the first-in-man off-pump surgical retensioning of the previously implanted artificial chords.

12.
Front Cardiovasc Med ; 10: 1047244, 2023.
Article En | MEDLINE | ID: mdl-37034321

Objectives: The present study aims to assess and describe the intracardiac blood flow dynamic in patients with mitral regurgitation (MR), repaired mitral valves (MV) and mitral valve prostheses using vector flow mapping (VFM). Methods: Patients with different MV pathologies and MV disease treatments were analysed. All patients underwent 2D transthoracic echocardiography, and images for flow visualization were acquired in VFM mode in an apical three-chamber view and four-chamber view. Vectors and vortices were qualitatively analyzed. Results: thirty-two (32) patients underwent 2D transthoracic echocardiography (TTE) with VFM analysis. We evaluated intracardiac flow dynamics in 3 healthy subjects, 10 patients with MR (5 degenerative, 5 functional), 4 patients who underwent MV repair, 5 who underwent MV replacement (3 biological, 2 mechanical), 2 surgically implanted transcatheter heart valve (THV), 2 transcatheter edge-to-edge MV repair with MitraClip (TEER), 3 transcatheter MV replacement (TMVR) and 3 transapical off-pump MV repair with NeoChord implantation. Blood flow patterns are significantly altered in patients with MV disease and MV repair compared to control patients. MV repair is superior to replacement in restoring more physiologicalpatterns, while TMVR reproducesan intraventricular flowcloser to normal than surgical MVR and TEER. Conclusions: Intracardiac flow patterns can be clearly defined using VFM. Restoration of a physiological blood flow pattern inside the LV directly depends on the procedure used to address MV disease.

13.
Front Cardiovasc Med ; 10: 1121488, 2023.
Article En | MEDLINE | ID: mdl-37063967

The AngioVac System (AngioDynamics, Latham, NY) was developed for the treatment of right-sided heart and intravenous masses. Lately, it has been employed to deal with left-sided heart masses, in particular, native valve endocarditis (NVE) and valve prostheses endocarditis (VPE) in high-risk patients. Left-sided heart endocarditis has a high morbidity, and it also has a high mortality when open heart surgery is performed. Recently, patients presenting with left NVE and VPE have been treated with the off-label use of the AngioVac System even if the solution presents a considerable cerebral embolization risk issue due to the risk of fragmentation rather than a complete en-bloc aspiration of the masses. A percutaneous cerebral embolism protection system is currently used in TAVI procedures, especially when the native valve presents extensive calcifications and consequent significant embolic risks. We hereby present a clinical case series of a combined utilization of the AngioVac System and cerebral embolism protection system Triguard (Keystone Heart Ltd., Herzliya, Israel) to treat left NVE and VPE in prohibitive-surgical-risk patients.

15.
Artif Organs ; 47(8): 1386-1394, 2023 Aug.
Article En | MEDLINE | ID: mdl-37039965

BACKGROUND: Post-acute myocardial infarction papillary muscle rupture (post-AMI PMR) may present variable clinical scenarios and degree of emergency due to result of cardiogenic shock. Veno-arterial extracorporeal life support (V-A ECLS) has been proposed to improve extremely poor pre- or postoperative conditions. Information in this respect is scarce. METHODS: From the CAUTION (meChanical complicAtion of acUte myocardial infarcTion: an InternatiOnal multiceNter cohort study) database (16 different Centers, data from 2001 to 2018), we extracted adult patients who were surgically treated for post-AMI PMR and underwent pre- or/and postoperative V-A ECLS support. The end-points of this study were in-hospital survival and ECLS complications. RESULTS: From a total of 214 post-AMI PMR patients submitted to surgery, V-A ECLS was instituted in 23 (11%) patients. The median age was 61.7 years (range 46-81 years). Preoperatively, ECLS was commenced in 10 patients (43.5%), whereas intra/postoperative in the remaining 13. The most common V-A ECLS indication was post-cardiotomy shock, followed by preoperative cardiogenic shock and cardiac arrest. The median duration of V-A ECLS was 4 days. V-A ECLS complications occurred in more than half of the patients. Overall, in-hospital mortality was 39.2% (9/23), compared to 22% (42/219) for the non-ECLS group. CONCLUSIONS: In post-AMI PMR patients, V-A ECLS was used in almost 10% of the patients either to promote bridge to surgery or as postoperative support. Further investigations are required to better evaluate a potential for increased use and its effects of V-A ECLS in such a context based on the still high perioperative mortality.


Cardiomyopathies , Extracorporeal Membrane Oxygenation , Heart Valve Diseases , Myocardial Infarction , Adult , Humans , Middle Aged , Aged , Aged, 80 and over , Extracorporeal Membrane Oxygenation/methods , Shock, Cardiogenic/etiology , Shock, Cardiogenic/surgery , Cohort Studies , Papillary Muscles/surgery , Myocardial Infarction/complications , Cardiomyopathies/complications , Heart Valve Diseases/complications
16.
J Am Heart Assoc ; 12(6): e026943, 2023 03 21.
Article En | MEDLINE | ID: mdl-36892041

Background Myocardial revascularization has been advocated to improve myocardial function and prognosis in ischemic cardiomyopathy (ICM). We discuss the evidence for revascularization in patients with ICM and the role of ischemia and viability detection in guiding treatment. Methods and Results We searched for randomized controlled trials evaluating the prognostic impact of revascularization in ICM and the value of viability imaging for patient management. Out of 1397 publications, 4 randomized controlled trials were included, enrolling 2480 patients. Three trials (HEART [Heart Failure Revascularisation Trial], STICH [Surgical Treatment for Ischemic Heart Failure], and REVIVED [REVascularization for Ischemic VEntricular Dysfunction]-BCIS2) randomized patients to revascularization or optimal medical therapy. HEART was stopped prematurely without showing any significant difference between treatment strategies. STICH showed a 16% lower mortality with bypass surgery compared with optimal medical therapy at a median follow-up of 9.8 years. However, neither the presence/extent of left ventricle viability nor ischemia interacted with treatment outcomes. REVIVED-BCIS2 showed no difference in the primary end point between percutaneous revascularization or optimal medical therapy. PARR-2 (Positron Emission Tomography and Recovery Following Revascularization) randomized patients to imaging-guided revascularization versus standard care, with neutral results overall. Information regarding the consistency of patient management with viability testing results was available in ≈65% of patients (n=1623). No difference in survival was revealed according to adherence or no adherence to viability imaging. Conclusions In ICM, the largest randomized controlled trial, STICH, suggests that surgical revascularization improves patients' prognosis at long-term follow-up, whereas evidence supports no benefit of percutaneous coronary intervention. Data from randomized controlled trials do not support myocardial ischemia or viability testing for treatment guidance. We propose an algorithm for the workup of patients with ICM considering clinical presentation, imaging results, and surgical risk.


Cardiomyopathies , Heart Failure , Myocardial Ischemia , Ventricular Dysfunction, Left , Humans , Tomography, X-Ray Computed , Myocardial Ischemia/complications , Myocardial Ischemia/surgery , Myocardial Ischemia/diagnosis , Myocardial Revascularization/methods , Heart Failure/diagnosis , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/surgery , Ischemia
18.
CVIR Endovasc ; 6(1): 7, 2023 Feb 21.
Article En | MEDLINE | ID: mdl-36809454

BACKGROUND: The Najuta stent-graft (Kawasumi Laboratories Inc., Tokyo, Japan) is usually easily advanced to the correct deployment position in the ascending aorta thanks to the pre-curved delivery J-sheath with all fenestrations automatically oriented towards the supra-aortic vessels. Aortic arch anatomy and delivery system stiffness could however represent limitations for proper endograft advancement, especially when the aortic arch bends sharply. The aim of this technical note is to report a series of bail-out procedures that could be useful to overcome the difficulties encountered during the Najuta stent-graft advancement up to the ascending aorta. MAIN BODY: The insertion, positioning and deployment of a Najuta stent-graft requires a through-and-through guidewire technique using a .035″ 400 cm hydrophilic nitinol guidewire (Radifocus™ Guidewire M Non-Vascular, Terumo Corporation, Tokyo, Japan) with right brachial and both femoral accesses. When standard maneuver to put the endograft tip into the aortic arch, some bail-out procedures can be applied to obtain proper positioning. Five techniques are described into the text: positioning of a coaxial extra-stiff guidewire; positioning of a long introducer sheath down to the aortic root from the right brachial access; inflation of a balloon inside the ostia of the supra-aortic vessels; inflation of a balloon inside the aortic arch (coaxial to the device); and transapical access technique. This is a troubleshooting guide for allowing physicians to overcome various difficulties with the Najuta endograft as well as for other similar devices. SHORT CONCLUSION: Technical issues in advancing the delivery system of Najuta stent-graft could occur. Therefore, the rescue procedures described in this technical note could be useful to guarantee the correct positioning and deployment of the stent-graft.

19.
J Thorac Cardiovasc Surg ; 165(3): 1045-1046, 2023 03.
Article En | MEDLINE | ID: mdl-35624052
20.
J Clin Med ; 13(1)2023 Dec 27.
Article En | MEDLINE | ID: mdl-38202159

BACKGROUND: Infective endocarditis (IE) is a serious disease, and in many cases, surgery is necessary. Whether the type of prosthesis implanted for aortic valve replacement (AVR) for IE impacts patient survival is a matter of debate. The aim of the present study is to quantify differences in long-term survival and recurrence of endocarditis AVR for IE according to prosthesis type among patients aged 40 to 65 years. METHODS: This was an analysis of the INFECT-REGISTRY. Trends in proportion to the use of mechanical prostheses versus biological ones over time were tested by applying the sieve bootstrapped t-test. Confounders were adjusted using the optimal full-matching propensity score. The difference in overall survival was compared using the Cox model, whereas the differences in recurrence of endocarditis were evaluated using the Gray test. RESULTS: Overall, 4365 patients were diagnosed and operated on for IE from 2000 to 2021. Of these, 549, aged between 40 and 65 years, underwent AVR. A total of 268 (48.8%) received mechanical prostheses, and 281 (51.2%) received biological ones. A significant trend in the reduction of implantation of mechanical vs. biological prostheses was observed during the study period (p < 0.0001). Long-term survival was significantly higher among patients receiving a mechanical prosthesis than those receiving a biological prosthesis (hazard ratio [HR] 0.546, 95% CI: 0.322-0.926, p = 0.025). Mechanical prostheses were associated with significantly less recurrent endocarditis after AVR than biological prostheses (HR 0.268, 95%CI: 0.077-0.933, p = 0.039). CONCLUSIONS: The present analysis of the INFECT-REGISTRY shows increased survival and reduced recurrence of endocarditis after a mechanical aortic valve prosthesis implant for IE in middle-aged patients.

...