Forensic Sci Int ; 359: 112001, 2024 Jun.
Article En | MEDLINE | ID: mdl-38714107

BACKGROUND: Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions. METHODS: A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I2 statistic was used to assess heterogeneity. RESULTS: A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases. CONCLUSIONS: Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.


Defibrillators, Implantable , Pacemaker, Artificial , Humans , Pacemaker, Artificial/adverse effects , Arrhythmias, Cardiac , Equipment Failure
2.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38696701

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Defibrillators, Implantable , Electric Countershock , Propensity Score , Registries , Humans , Female , Male , Middle Aged , Aged , Sex Factors , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Risk Factors , Treatment Outcome , Arrhythmias, Cardiac/therapy , Risk Assessment , Europe , Time Factors , Death, Sudden, Cardiac/prevention & control
3.
Heart Rhythm ; 2024 May 27.
Article En | MEDLINE | ID: mdl-38810922

BACKGROUND: Pulsed field ablation (PFA) and very-high power short-duration(vHPSD) radiofrequency ablation are the most recently introduced technologies for atrial fibrillation (AF) ablation. The procedural performance, safety, and effectiveness of PFA versus vHPSD is currently unknown. OBJECTIVE: To compare PFA with vHPSD for the treatment of paroxysmal/persistent AF. METHODS: We conducted an observational, multicenter study enrolling 534 consecutive patients (63±9years, 36% female) with paroxysmal (n=368,69%) or persistent (n=166,31%) AF undergoing ablation using either PFA (Farawave; n=192) or vHPSD (90W/4sec; QDOT Micro; n=342) between 2020 and 2023. Atrial tachyarrhythmia (AT) recurrence after a 1-month blanking period was the primary efficacy endpoint and was assessed both overall and in propensity score-matched patients. The primary safety endpoint was a composite of procedure-related complications. RESULTS: Successful PVI was achieved in all patients, with shorter procedure duration (PFA,70 min; vHPSD,100 min; p<0.001), but with longer fluoroscopy time (PFA,15 min; vHPSD,7 min; p<0.001) in PFA group. PFA was associated with more frequent use of general anesthesia (p<0.001). Primary safety outcome events occurred in 19 patients(3.5%), with similar prevalence in both groups (PFA,4%; vHPSD,3%; p=0.745). After a median follow-up of 12(9-12) months, survival free from recurrent AT was similar between the PFA and vHPSD groups, both overall (12-month estimate: PFA,75%; vHPSD,76%; log-rank p=0.73) and in propensity score-matched patients (n=342; 12-month estimate: PFA,75%; vHPSD,77%; log-rank p=0.980). CONCLUSION: In a large, multicenter experience, PFA was associated with more common use of general anesthesia, shorter procedural times, and longer fluoroscopy exposure compared to vHPSD ablation, with both techniques displaying superimposable safety/efficacy.

4.
Article En | MEDLINE | ID: mdl-38814252

BACKGROUND: Catheter ablation (CA) of atrial fibrillation is routinely used to obtain rhythm control. Evidence suggest that catheter ablation should be done during uninterrupted oral anticoagulation. METHODS: Italian Registry in the setting of atrial fibrillation ablation with rivaroxaban (IRIS) is an Italian multicenter, non-interventional, prospective study which enrolled 250 consecutive atrial fibrillation patients eligible for catheter ablation on rivaroxaban. The decision for rivaroxaban management was left to the physician: uninterrupted or shortly interrupted prior to Catheter ablation. Patients received a follow-up visit at 1 month and 12 months after the procedure. RESULTS: The primary outcome, represented by all-cause death and systemic embolism at 1 month and 12 months was characterized by one transient ischemic attack and one myocardial infarction in the first 30 days. Both events happened in patients with shortly interrupted strategy (P=0.147), and both in patients who underwent radiofrequency ablation (P=0.737). In the primary safety outcome represented by major bleeding we did not register any event in the 12-month follow-up. The secondary outcome constituted by minor bleeding registered 1 event, after the first 30 days since CA. CONCLUSIONS: IRIS is the biggest real-life data registry regarding CA ablation on rivaroxaban in Italian setting, proving the safety and efficacy of rivaroxaban.

5.
Article En | MEDLINE | ID: mdl-38814525

BACKGROUND: Recent data on pulsed field ablation (PFA) for atrial fibrillation (AF) ablation suggest a progressive reduction in procedural times. Real-world data regarding the relationship between the learning curve of PFA and clinical outcomes are scarce. The objective was to evaluate the PFA learning curve and its impact on acute outcomes. METHODS: Consecutive patients undergoing AF ablation with the FARAPULSE™ PFA system were included in a prospective, non-randomized multicenter study. Procedural times were stratified on the operators' learning curve. Comparative analysis of skin-to-skin time was conducted with radiofrequency (RF) and cryoablation (CB) pulmonary vein isolation (PVI) procedures performed by the same operators in the previous year. RESULTS: Among 752 patients, 35.1% were females, and 66.9% had paroxysmal AF; mean age was 62.2 ± 10 years. A total of 62.5% of procedures were performed by operators with > 20 PFA procedures. Both time to PVI (25.6 ± 10 min vs 16.5 ± 8, p < 0.0001) and fluoroscopy time (19.8 ± 8 min vs 15.9 ± 8 min, p = 0.0045) significantly improved after 10 associated with consistent linear trend towards procedural time reduction (R2 0.92-0.68 across various procedural metrics). Current PFA skin-to-skin time was lower than the historical skin-to-skin one in 217 (62.4%) procedures; it was similar in 112 (32.2%) cases and higher than the historical skin-to-skin one in 19 (5.5%). No major complications were reported. CONCLUSIONS: In this nationwide multicentric experience, the novel PFA system proved to be fast, safe, and acutely effective in both paroxysmal and persistent AF patients. The learning curve appears to be rapid, as improvements in procedural parameters were observed after only a few procedures. CLINICAL TRIAL REGISTRATION: Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA). URL: http://clinicaltrials.gov/ Identifier: NCT05617456.

6.
J Clin Med ; 13(5)2024 Feb 27.
Article En | MEDLINE | ID: mdl-38592178

Although mitral valve prolapse (MVP) is the most prevalent valvular abnormality in Western countries and generally carries a good prognosis, a small subset of patients is exposed to a significant risk of malignant ventricular arrhythmias (VAs) and sudden cardiac death (SCD), the so-called arrhythmic MVP (AMVP) syndrome. Recent work has emphasized phenotypical risk features of severe AMVP and clarified its pathophysiology. However, the appropriate assessment and risk stratification of patients with suspected AMVP remains a clinical conundrum, with the possibility of both overestimating and underestimating the risk of malignant VAs, with the inappropriate use of advanced imaging and invasive electrophysiology study on one hand, and the catastrophic occurrence of SCD on the other. Furthermore, the sports eligibility assessment of athletes with AMVP remains ill defined, especially in the grey zone of intermediate arrhythmic risk. The definition, epidemiology, pathophysiology, risk stratification, and treatment of AMVP are covered in the present review. Considering recent guidelines and expert consensus statements, we propose a comprehensive pathway to facilitate appropriate counseling concerning the practice of competitive/leisure-time sports, envisioning shared decision making and the multidisciplinary "sports heart team" evaluation of borderline cases. Our final aim is to encourage an active lifestyle without compromising patients' safety.

7.
J Clin Med ; 13(7)2024 Mar 24.
Article En | MEDLINE | ID: mdl-38610635

There are no investigations about the outcomes of idiopathic PVC catheter ablation (CA) in athletes compared to the sedentary population. We conducted a prospective single-centre observational study. The primary and secondary procedural outcomes were the post-ablation reduction of premature ventricular contractions (PVCs) in an athletes vs. non-athletes group and in agonist vs. leisure-time athletes. The third was the evaluation of the resumption of physical activity and the improvement of symptoms in agonist and leisure-time athletes. From January 2020 to October 2022 we enrolled 79 patients with RVOT/LVOT/fascicular PVC presumed origin. The median percentage of decrease between the pre-procedure and post-procedure Holter monitoring in the non-athletes group was 96 (IQR 68-98) and 98 in the athletes group (IQR 92-99) (p = 0.08). Considering the athletes, the median percentage of decrease in the number of PVCs was 98 (IQR 93-99) and 98 (IQR 87-99), respectively, in leisure-time and agonistic athletes (p = 0.42). Sixteen (70%) leisure time and seventeen (90%) agonist athletes (p = 0.24) have resumed physical activity 3 months after PVC CA; among agonistic athletes, 59% have resumed competitive physical activity. Many leisure-time (88%) and agonist (70%) athletes experienced an improvement in symptoms after ablation. PVC CA was effective and safe in both groups, reducing symptoms and allowing a quick and safe return to sports activities in athletes.

8.
Europace ; 26(4)2024 Mar 30.
Article En | MEDLINE | ID: mdl-38584394

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electric Countershock/adverse effects , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
9.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Article En | MEDLINE | ID: mdl-38674259

Background and Objectives: Cardiac magnetic resonance (CMR) imaging has become an essential instrument in the study of cardiomyopathies; it has recently been integrated into the diagnostic workflow for cardiac amyloidosis (CA) with remarkable results. An additional emerging role is the stratification of the arrhythmogenic risk by scar analysis and the possibility of merging these data with electro-anatomical maps. This is made possible by using a software (ADAS 3D, Galgo Medical, Barcelona, Spain) able to provide 3D heart models by detecting fibrosis along the whole thickness of the myocardial walls. Little is known regarding the applications of this software in the wide spectrum of cardiomyopathies and the potential benefits have yet to be discovered. In this study, we tried to apply the ADAS 3D in the context of CA. Materials and Methods: This study was a retrospectively analysis of consecutive CMR imaging of patients affected by CA that were treated in our center (Marche University Hospital). Wherever possible, the data were processed with the ADAS 3D software and analyzed for a correlation between the morphometric parameters and follow-up events. The outcome was a composite of all-cause mortality, unplanned cardiovascular hospitalizations, sustained ventricular arrhythmias (VAs), permanent reduction in left ventricular ejection fraction, and pacemaker implantation. The secondary outcomes were the need for a pacemaker implantation and sustained VAs. Results: A total of 14 patients were deemed eligible for the software analysis: 8 patients with wild type transthyretin CA, 5 with light chain CA, and 1 with transthyretin hereditary CA. The vast majority of imaging features was not related to the composite outcome, but atrial wall thickening displayed a significant association with both the primary (p = 0.003) and the secondary outcome of pacemaker implantation (p = 0.003). The software was able to differentiate between core zones and border zones of scars, with the latter being the most extensively represented in all patients. Interestingly, in a huge percentage of CMR images, the software identified the highest degree of core zone fibrosis among the epicardial layers and, in those patients, we found a higher incidence of the primary outcome, without reaching statistical significance (p = 0.18). Channels were found in the scar zones in a substantial percentage of patients without a clear correlation with follow-up events. Conclusions: CMR imaging plays a pivotal role in cardiovascular diagnostics. Our analysis shows the feasibility and applicability of such instrument for all types of CA. We could not only differentiate between different layers of scars, but we were also able to identify the presence of fibrosis channels among the different scar zones. None of the data derived from the ADAS 3D software seemed to be related to cardiac events in the follow-up, but this might be imputable to the restricted number of patients enrolled in the study.


Amyloidosis , Cardiomyopathies , Cicatrix , Magnetic Resonance Imaging , Humans , Male , Pilot Projects , Female , Cardiomyopathies/diagnostic imaging , Amyloidosis/diagnostic imaging , Amyloidosis/complications , Aged , Cicatrix/diagnostic imaging , Retrospective Studies , Middle Aged , Magnetic Resonance Imaging/methods , Software
11.
J Clin Med ; 13(7)2024 Apr 03.
Article En | MEDLINE | ID: mdl-38610866

Background: The management of cardiogenic shock (CS) after ACS has evolved over time, and the development of a multidisciplinary team-based approach has been shown to improve outcomes, although mortality remains high. Methods: All consecutive patients with ACS-CS admitted at our CICU from March 2012 to July 2021 were included in this single-center retrospective study. In 2019, we established a "shock team" consisting of a cardiac intensivist, an interventional cardiologist, an anesthetist, and a cardiac surgeon. The primary outcome was in-hospital mortality. Results: We included 167 patients [males 67%; age 71 (61-80) years] with ischemic CS. The proportion of SCAI shock stages from A to E were 3.6%, 6.6%, 69.4%, 9.6%, and 10.8%, respectively, with a mean baseline serum lactate of 5.2 (3.1-8.8) mmol/L. Sixty-six percent of patients had severe LV dysfunction, and 76.1% needed ≥ 1 inotropic drug. Mechanical cardiac support (MCS) was pursued in 91.1% [65% IABP, 23% Impella CP, 4% VA-ECMO]. From March 2012 to July 2021, we observed a significative temporal trend in mortality reduction from 57% to 29% (OR = 0.90, p = 0.0015). Over time, CS management has changed, with a significant increase in Impella catheter use (p = 0.0005) and a greater use of dobutamine and levosimendan (p = 0.015 and p = 0.0001) as inotropic support. In-hospital mortality varied across SCAI shock stages, and the SCAI E profile was associated with a poor prognosis regardless of patient age (OR 28.50, p = 0.039). Conclusions: The temporal trend mortality reduction in CS patients is multifactorial, and it could be explained by the multidisciplinary care developed over the years.

12.
Eur Heart J Open ; 4(2): oeae023, 2024 Mar.
Article En | MEDLINE | ID: mdl-38645408

Aims: Albeit often asymptomatic, heart involvement in systemic sclerosis (SSc) represents a negative prognostic factor, accounting for nearly one-fourth of all deaths. Global longitudinal strain (GLS) is accurate in detecting heart involvement in patients with SSc and no overt cardiac disease and allows early detection and longitudinal monitoring, but its association with clinical endpoints has not been tested so far. The primary outcome was the association between left and right GLS and mortality for all causes. The secondary outcome was the association between left and right GLS and hospitalizations. Methods and results: A prospective longitudinal study enrolling all consecutive patients with SSc without structural heart disease or previous cardiovascular event.A total of 164 patients were enrolled, of whom 19 (11.5%) died during follow-up and 48 (29.3%) were hospitalized. Both left (LV) and right ventricle (RV) GLS at enrolment were independently associated with an increased risk of death for all causes and hospitalizations. Patients with biventricular GLS impairment, respectively, had a 4.2-, 4.9-, and 13.9-fold increased risk of death when compared with patients with only LV, only RV, or no impairment (P < 0.001). The incidence of hospitalization in patients with biventricular GLS impairment was nearly four times higher when compared with patients with only LV or only RV impairment, and nine times higher when compared with normal biventricular GLS (P < 0.001). Conclusion: Biventricular GLS is associated with an increased risk of death and hospitalization in patients with SSc during a median of 3-year follow-up, acting as a reliable and accurate prognostic tool in everyday practice.

13.
Medicina (Kaunas) ; 60(4)2024 Mar 22.
Article En | MEDLINE | ID: mdl-38674168

The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.


Defibrillators, Implantable , Magnetic Resonance Imaging , Pacemaker, Artificial , Humans , Defibrillators, Implantable/standards , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/instrumentation , Arrhythmias, Cardiac/diagnostic imaging
14.
J Clin Med ; 13(6)2024 Mar 18.
Article En | MEDLINE | ID: mdl-38541971

Ventricular tachycardias (VTs) and electrical storms (ES) are life-threatening conditions mostly seen in the setting of structural heart disease (SHD). Traditional management strategies, predominantly centered around pharmacological interventions with antiarrhythmic drugs, have demonstrated limited efficacy in these cases, whereas catheter ablation is related with more favorable outcomes. However, patients with hemodynamically unstable, recurrent VT or ES may present cardiogenic shock (CS) that precludes the procedure, and catheter ablation in patients with SHD portends a multifactorial intrinsic risk of acute hemodynamic decompensation (AHD), that is associated with increased mortality. In this setting, the use of mechanical circulatory support (MCS) systems allow the maintenance of end-organ perfusion and cardiac output, improving coronary flow and myocardial mechanics, and minimizing the effect of cardiac stunning after multiple VT inductions or cardioversion. Although ablation success and VT recurrence are not influenced by hemodynamic support devices, MCS promotes diuresis and reduces the incidence of post-procedural kidney injury. In addition, MCS has a role in post-procedural mortality reduction at long-term follow-up. The current review aims to provide a deep overview of the rationale and modality of MCS in patients with refractory arrhythmias and/or undergoing VT catheter ablation, underlining the importance of patient selection and timing for MCS and summarizing reported clinical experiences in this field.

15.
Article En | MEDLINE | ID: mdl-38519418

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.

16.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Article En | MEDLINE | ID: mdl-38445836

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Brugada Syndrome , Defibrillators, Implantable , Pacemaker, Artificial , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Brugada Syndrome/therapy , Electrocardiography/methods , Electrocardiography, Ambulatory/methods , Adult
17.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Article En | MEDLINE | ID: mdl-38310489

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Acute Kidney Injury , Atrial Fibrillation , Catheter Ablation , Hemoglobinuria , Humans , Atrial Fibrillation/surgery , Male , Female , Catheter Ablation/adverse effects , Catheter Ablation/methods , Middle Aged , Acute Kidney Injury/prevention & control , Acute Kidney Injury/etiology , Aged , Hemoglobinuria/etiology , Hemoglobinuria/prevention & control , Creatinine/blood , Retrospective Studies , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Fluid Therapy/methods
18.
JACC Clin Electrophysiol ; 10(3): 487-498, 2024 Mar.
Article En | MEDLINE | ID: mdl-38206263

BACKGROUND: Desmoplakin (DSP) pathogenic/likely pathogenic (P/LP) variants are associated with malignant phenotypes of arrhythmogenic cardiomyopathy (DSP-ACM). Reports of outcomes after ventricular tachycardia (VT) ablation in DSP-ACM are scarce. OBJECTIVES: In this study, the authors sought to report on long-term outcomes of VT ablation in DSP-ACM. METHODS: Patients with P/LP DSP variants at 9 institutions undergoing VT ablation were included. Demographic, clinical, and instrumental data as well as all ventricular arrhythmia (VA) events were collected. Sustained VAs after the index procedure were the primary outcome. A per-patient before and after ablation comparison of rates of VA episodes per year was performed as well. RESULTS: Twenty-four DSP-ACM patients (39.3 ± 12.1 years of age, 62.5% male, median 6,116 [Q1-Q3: 3,362-7,760] premature ventricular complexes [PVCs] per 24 hours, median 4 [Q1-Q3: 2-11] previous VA episodes per patient at ablation) were included. Index procedure was most commonly endocardial/epicardial (19/24) The endocardium of the right ventricle (RV), the left ventricle (LV), or both ventricles were mapped in 8 (33.3%), 9 (37.5%), and 7 (29.2%) cases, respectively. Low voltage potentials were found in 10 of 15 patients in the RV and 11 of 16 in the LV. Endocardial ablation was performed in 18 patients (75.0%). Epicardial mapping in 19 patients (79.2%) identified low voltage potentials in 17, and 16 received epicardial ablation. Over the following 2.9 years (Q1-Q3: 1.8-5.5 years), 13 patients (54.2%) experienced VA recurrences. A significant reduction in per-patient event/year before and after ablation was observed (1.4 [Q1-Q3: 0.5-2.4] to 0.1 [Q1-Q3: 0.0-0.4]; P = 0.009). Two patients needed heart transplantation, and 4 died (3 of heart failure and 1 noncardiac death). CONCLUSIONS: VT ablation in DSP-ACM is effective in reducing the VA burden of the disease, but recurrences are common. Most VT circuits are epicardial, with both LV and RV low voltage abnormalities. Heart failure complicates clinical course and is an important cause of mortality.


Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Catheter Ablation , Heart Failure , Tachycardia, Ventricular , Humans , Male , Middle Aged , Female , Desmoplakins , Treatment Outcome , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/surgery , Cardiomyopathies/etiology , Catheter Ablation/methods , Heart Failure/etiology
19.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Article En | MEDLINE | ID: mdl-38246594

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Cardiomyopathy, Dilated , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Electric Countershock/adverse effects , Arrhythmogenic Right Ventricular Dysplasia/complications , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/therapy , Registries , Treatment Outcome
20.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Article En | MEDLINE | ID: mdl-38195003

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Arrhythmogenic Right Ventricular Dysplasia , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/epidemiology , Arrhythmogenic Right Ventricular Dysplasia/therapy , Retrospective Studies , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Risk Factors , North America/epidemiology , Europe/epidemiology
...