Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Acad Emerg Med ; 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39107969
2.
J Clin Ultrasound ; 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38822664

RESUMEN

Aortic dissection (AD) is a rare and potentially fatal condition that may be diagnosed late. During an emergency or elective abdominal ultrasound (US) examination, when going to evaluate the abdominal aorta for other reasons, it may happen that we find ourselves suspecting an AD. It is therefore important to know the US characteristics of this pathology to avoid wrong or missed diagnoses. Here, we present our practical experience regarding the application of US in the study of the abdominal aorta, which allowed us on several occasions to find an unexpected dissection in patients brought to our attention for other reasons.

3.
West J Emerg Med ; 25(2): 268-274, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38596929

RESUMEN

Introduction: Numerous studies have demonstrated the accuracy of point-of-care ultrasound (POCUS). Portable, handheld devices have expanded the clinical scope of POCUS at a fraction of the cost of traditional, cart-based models. There is a paucity of data assessing the diagnostic accuracy of portable devices. Our objective in this study was to compare the diagnostic accuracy of a portable device with a cart-based model. Methods: This was an institutional review board-approved, observational, prospective, randomized clinical trial (NCT05196776) of a convenience sample of adult patients who presented to a university-based health system. Patients who required a cardiac, lung, renal, aorta, or biliary POCUS were randomized to a portable device or to a cart-based model. We hypothesized that the cart-based model would have a 90% diagnostic accuracy vs 70% for the handheld device. To detect a 20% difference, the sample size was calculated to be 98, with 49 patients randomized to each arm. We used standard 2x2 tables to calculate test characteristics with 95% confidence intervals (CI). Results: A total of 110 patients were enrolled, with 56 patients randomized to the cart-based model and 54 to the handheld device. The sensitivity, specificity, and diagnostic accuracy of the cart-based vs handheld were 77.8% (40-97.2) vs 92.9% (66.1-99.8), 91.5% (79.6-97.6) vs 92.3% (79.1-98.4%), and 89.3% (78.1-96) vs 92.5% (81.8-97.9), respectively. Conclusion: The diagnostic accuracy of a portable, handheld device is similar to that of a cart-based model.


Asunto(s)
Pruebas en el Punto de Atención , Proyectos de Investigación , Adulto , Humanos , Estudios Prospectivos , Ultrasonografía
4.
Acad Emerg Med ; 31(2): 112-118, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38010071

RESUMEN

OBJECTIVES: An aortic dissection (AoD) is a potentially life-threatening emergency with mortality rates exceeding 50%. While computed tomography angiography remains the diagnostic standard, patients may be too unstable to leave the emergency department. Investigators developed a point-of-care ultrasound (POCUS) protocol combining transthoracic echocardiography (TTE) and the abdominal aorta. The study objective was to determine the test characteristics of this protocol. METHODS: This was an institutional review board-approved, multicenter, prospective, observational, cohort study of a convenience sample of adult patients. Patients suspected of having an AoD received a TTE and abdominal aorta POCUS. Three sonographic signs suggested AoD: a pericardial effusion, an intimal flap, or an aortic outflow track diameter measuring more than 35 mm. Investigators present continuous and categorical data as medians with interquartile ranges or proportions with 95% confidence intervals (CIs) and utilized standard 2 × 2 tables on MedCalc (Version 19.1.6) to calculate test characteristics with 95% CI. RESULTS: Investigators performed 1314 POCUS examinations, diagnosing 21 Stanford type A and 23 Stanford type B AoD. Forty-one of the 44 cases had at least one of the aforementioned sonographic findings. The protocol has a sensitivity of 93.2% (95% CI 81.3-98.6), specificity of 90.9 (95% CI 89.2-92.5), positive and negative predictive values of 26.3% (95% CI 19.6-33.9) and 99.7% (95% CI 99.2-100), respectively, and an accuracy of 91% (95% CI 89.3-92.5). CONCLUSIONS: The SPEED protocol has an overall sensitivity of 93.2% for AoD.


Asunto(s)
Disección Aórtica , Ecocardiografía , Adulto , Humanos , Disección Aórtica/diagnóstico por imagen , Estudios de Cohortes , Estudios Prospectivos , Ultrasonografía
6.
Acad Emerg Med ; 29(2): 159-163, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34608713

RESUMEN

OBJECTIVES: Arthrocentesis is commonly performed in the emergency department, but success rates vary based on location. Presently, there is a paucity of data assessing the utility of ultrasound-guided (USG) medium-sized joint arthrocentesis. The objective of this study was to compare the success of USG and landmark-guided (LMG) medium-sized joint arthrocentesis. METHODS: This was a single-center, prospective, randomized clinical trial (NCT03327584) of a convenience sample of adult patients who presented to an urban, university hospital with > 105,000 visits annually. Patients with a suspected medium-sized joint effusion (defined as elbow, wrist, or ankle) undergoing arthrocentesis were randomized into LMG or USG using the GE Logiq e linear transducer (4-10 MHz). The following patients were excluded: on anticoagulation, with soft tissue infection overlying the joint, or involving an artificial joint. Statistical analysis included the Fisher exact, Mann-Whitney U-test, and t-test. RESULTS: Overall, 44 patients were enrolled with 23 patients randomized into the LMG group and 21 patients into the USG arm. USG was significantly better than LMG with an overall success of 94.1% versus 60% for LMG (difference = 34.1%, 95% confidence interval [CI] = 4.90 to 58.83). USG first-pass success was 82.4% versus 46.7% for LMG (difference = 35.7%, 95% CI = 2.76 to 60.37) and a mean of 1.35 attempts versus 2.00 for LMG (difference = 0.65, 95% CI = 0.005 to 1.296). Of the 14 LMG failures, eight had no effusion present on USG crossover. Four patients in the USG group had no effusion present. CONCLUSIONS: Ultrasound guidance improved first-pass and overall successful arthrocentesis of medium-sized joint effusions.


Asunto(s)
Artrocentesis , Ultrasonografía Intervencional , Adulto , Servicio de Urgencia en Hospital , Humanos , Estudios Prospectivos , Ultrasonografía
7.
Emerg Radiol ; 28(5): 1041-1043, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33890187

RESUMEN

Intussusception is an intestinal emergency caused by the telescoping of proximal bowel into an adjacent distal bowel segment. Nearly 50% of cases are missed on initial presentation leading to an increased risk of intestinal obstruction, ischemia, and perforation. The authors present two cases of pediatric intussusception whereby point-of-care ultrasound expedited the diagnosis and treatment in a non-pediatric dedicated emergency department. Given the risks of an undiagnosed intussusception and its nonspecific presentations, a prompt and precise diagnosis remains crucial to its successful management. The ubiquity and accuracy of point-of-care ultrasound make it an ideal adjunct for the diagnosis of intussusception.


Asunto(s)
Obstrucción Intestinal , Intususcepción , Niño , Humanos , Intususcepción/diagnóstico por imagen , Sistemas de Atención de Punto , Ultrasonografía
8.
J Emerg Med ; 60(5): 615-625, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33722414

RESUMEN

BACKGROUND: The viral illness severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), more commonly known as Coronavirus 2019 (COVID-19), has become a global pandemic, infecting over 100 million individuals worldwide. OBJECTIVES: The objective of this study was to compare the test characteristics of point-of-care lung ultrasound (LUS) with chest x-ray study (CXR) at radiographically detecting COVID-19 pneumonia. METHODS: This was a single-center, prospective, observational study at an urban university hospital with > 105,000 patient visits annually. Patients ≥ 18 years old, who presented to the Emergency Department with predefined signs and symptoms of COVID-19, were eligible for enrollment. Each patient received an LUS using a portable, handheld ultrasound followed by a single-view, portable anteroposterior CXR. Patients with an abnormal LUS or CXR underwent a non-contrast-enhanced computed tomography scan (NCCT). The primary outcome was the radiographic diagnosis of COVID-19 pneumonia on NCCT. RESULTS: One hundred ten patients underwent LUS, CXR, and NCCT; 99 LUS and 73 CXRs were interpreted as positive; 81 NCCTs were interpreted as positive, providing a prevalence of COVID-19 pneumonia of 75% (95% confidence interval [CI] 66-83.2) in our study population. LUS sensitivity was 97.6% (95% CI 91.6-99.7) vs. 69.9% (95% CI 58.8-79.5) for CXR. LUS specificity was 33.3% (95% CI 16.5-54) vs. 44.4% (95% CI 25.5-64.7) for CXR. LUS positive predictive value and negative predictive value were 81.8% (95% CI 72.8-88.9) and 81.8% (95% CI 48.2-97.7), respectively, vs. 79.5% (95% CI 68.4-88), and 32.4% (95% CI 18-49.8), respectively, for CXR. CONCLUSION: LUS was more sensitive than CXR at radiographically identifying COVID-19 pneumonia.


Asunto(s)
COVID-19/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Radiografía Torácica/métodos , SARS-CoV-2/aislamiento & purificación , Ultrasonografía/métodos , COVID-19/epidemiología , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19 , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nasofaringe/virología , Neumonía/diagnóstico por imagen , Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Prevalencia , Estudios Prospectivos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2/genética
9.
J Emerg Med ; 60(2): 210-215, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33097355

RESUMEN

BACKGROUND: Emergency physicians are frequently required to identify and triage patients with increased intracranial pressure (ICP). Idiopathic intracranial hypertension (IIH) is a possible cause that must be considered. Its prognosis depends on prompt recognition and treatment, and progression of the disease can lead to permanent vision loss and considerable morbidity. Point-of-care ultrasound can rapidly identify elevated ICP. Measurements of the optic nerve sheath diameter (ONSD) and optic disc elevation (ODE) can act as surrogates for ICP. CASE SERIES: We describe five cases in which ultrasound was used to identify increased ICP and aid clinical decision-making. In several of the cases, ultrasound was used to confirm a suspicion for IIH and initiate therapy while awaiting the results of a more time-consuming and technically challenging test, such as lumbar puncture or optical coherence tomography. One of the patients was pregnant, and sonographic evidence of elevated ICP helped avoid exposing the patient to unnecessary radiation. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Ultrasound is a quick and versatile tool for screening patients with neurologic symptoms, and when integrated into the proper clinical context, can reduce the use of more invasive tests. It can be particularly useful in patients with pathology that may not show abnormalities on computed tomography scan or in whom lumbar puncture is technically difficult, making patients at risk for IIH well-suited to examination by ultrasound. We use a cutoff of 5 mm for ONSD and 0.6 mm for ODE, though there are no universally agreed on cutoff values.


Asunto(s)
Hipertensión Intracraneal , Seudotumor Cerebral , Servicio de Urgencia en Hospital , Humanos , Hipertensión Intracraneal/diagnóstico por imagen , Presión Intracraneal , Nervio Óptico/diagnóstico por imagen , Sistemas de Atención de Punto , Seudotumor Cerebral/diagnóstico por imagen , Ultrasonografía
10.
J Emerg Med ; 60(2): 216-219, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33092972

RESUMEN

BACKGROUND: A cesarean scar pregnancy (CSP) is a clinically important form of ectopic pregnancy that carries a high risk of maternal morbidity and mortality. As the rate of cesarean sections has risen, this diagnosis is becoming an increasingly important consideration for providers caring for patients in early pregnancy. CASE REPORT: We present three cases of CSPs in which point-of-care ultrasound expedited the diagnosis and treatment in the emergency department. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Given the risks of an undiagnosed CSP, the increasing incidence of CSP, and the number of effective treatment options available in early gestation, the prompt and accurate diagnosis of CSP remains crucial to its successful management. As such, it is an important diagnosis for the emergency physician to consider when evaluating a patient in early pregnancy.


Asunto(s)
Cicatriz , Embarazo Ectópico , Cesárea/efectos adversos , Cicatriz/complicaciones , Femenino , Humanos , Sistemas de Atención de Punto , Embarazo , Embarazo Ectópico/diagnóstico por imagen , Ultrasonografía
11.
J Emerg Med ; 59(6): 911-917, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32917440

RESUMEN

BACKGROUND: More than 10 million arterial lines are placed annually worldwide, many of which happen in the emergency department. Before the introduction of point-of-care ultrasound, landmark-guided palpation (LMGP) was considered standard of care. OBJECTIVE: The objective of this study is to compare ultrasound-guided (USG) and LMGP of radial arterial line cannulation by novice emergency medicine interns. METHODS: This was a single-center, prospective, randomized controlled trial (NCT03326739) of a convenience sample of adult patients who presented to an urban, university hospital with 100,000 visits annually. There was no funding for this study. Patients who required an arterial line were blindly randomized into LMGP or USG groups. Only novice emergency medicine interns, defined as interns with <15 previous placements, who were not blinded, performed the cannulation. Statistical analyses included t and Fisher exact tests. RESULTS: Forty patients were enrolled with 20 patients randomized to each group. USG had a first-pass success of 75% vs. 0% for LMGP (p < 0.00001) and an overall success of 100% vs. 15% for LMGP (p < 0.00001), a mean of 1.30 attempts vs. 2.95 attempts for LMGP (a difference of 1.65; p < 0.0001), and a mean time for placement of 264 s vs. 524 s for LMGP (a difference of 260; p = 0.0025). Of the failed LMGP, USG crossover was 100% successful with a mean of 1.37 attempts (95% confidence interval 0.58-2.16) and 180 s for placement (95% confidence interval 97.92-262.08). Five percent of LMGP had a complication vs. 0% for USG (p = 1.0). CONCLUSIONS: USG improved first-pass and overall success of radial arterial line cannulation while reducing time to access and attempts when used by novice emergency medicine interns.


Asunto(s)
Cateterismo Periférico , Medicina de Emergencia , Dispositivos de Acceso Vascular , Adulto , Humanos , Palpación , Estudios Prospectivos , Ultrasonografía Intervencional
12.
J Emerg Med ; 59(5): 693-698, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32826122

RESUMEN

BACKGROUND: Physical examination for peritonsillar abscess (PTA) has limited sensitivity. Traditional management involves blind needle aspiration, which has a false negative rate of 10-24%. A randomized controlled trial by Costantino et al. demonstrated that point-of-care ultrasound (POCUS) improves PTA management. OBJECTIVES: Compare the use and impact of POCUS between patient cohorts prior to and after the trial by Costantino et al. METHODS: Retrospective cohort study of adult patients diagnosed with PTA. Cohort 1 presented to the emergency department (ED) January 2007-December 2008. Cohort 2 presented between January 2013 and December 2014. Data were separated into those with POCUS vs. without ultrasound (NUS). Primary endpoint was POCUS utilization. Secondary endpoints were successful aspiration, otolaryngology (ear, nose, and throat [ENT]) consultation, computed tomography (CT) imaging, unscheduled return visits, and length of stay (LOS). The Fisher's exact and t-tests analyzed data. RESULTS: Cohort 1 enrolled 48 patients, vs. 114 patients for cohort 2. Twelve patients in cohort 1 had a POCUS (25%) vs 89 in cohort 2 (78%) (p < 0.0001; odds ratio [OR] 0.09 (95% confidence interval [CI] 0.04-0.20). Emergency physician (EP) successful aspiration: 89.1% POCUS vs. 24.5% NUS (p < 0.0001; OR 25 [95% CI 10-59]). Combined EP/ENT successful aspiration: 99.0% POCUS vs. 80.3% NUS (p < 0.0001; OR 24 [95% CI 3-193]). ENT consultation:12.9% POCUS vs. 65.6% NUS (p < 0.0001; OR 0.07 [95% CI 0.03-0.17]). CT usage: 23.8% POCUS vs. 37.7% NUS (p = 0.07; OR 0.51 [95% CI 0.25-1.02]). Return visits: 3.96% POCUS vs. 18.0% NUS (p = 0.004; OR 0.18 [95% CI 0.05-0.61]). CONCLUSION: POCUS use has increased for PTA treatment, improves aspiration, and decreases consultations, CTs, return visits, and LOS.


Asunto(s)
Absceso Peritonsilar , Adulto , Servicio de Urgencia en Hospital , Medicina Basada en la Evidencia , Humanos , Absceso Peritonsilar/diagnóstico por imagen , Absceso Peritonsilar/terapia , Sistemas de Atención de Punto , Estudios Retrospectivos , Ultrasonografía
13.
Clin Pract Cases Emerg Med ; 4(1): 79-82, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32064433

RESUMEN

Acute aortic occlusion is an emergent vascular condition not encountered routinely. Given its varied presentations, including neurovascular deficits and mimicking an acute abdomen, the diagnosis is often delayed causing increased morbidity and mortality. We present a case of acute abdominal aortic occlusion masquerading as sudden onset lower extremity pain and weakness in an 86-year-old female requiring emergent thrombectomy. This is only the second case report to discuss the use of point-of-care ultrasound to expedite diagnosis and management.1.

14.
J Emerg Med ; 56(3): 323-326, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30638648

RESUMEN

BACKGROUND: Internal jugular venous thrombosis (IJVT) is an uncommon condition rarely diagnosed in the outpatient setting. IJVT carries significant morbidity and mortality and must be considered in the differential diagnosis for new-onset neck pain and swelling, especially in the emergency setting. Paget-Schroetter syndrome (PSS), or primary thrombosis secondary to effort, is an uncommon, likely under-recognized etiology of thrombosis. We report a case of PSS extending from the right subclavian vein into the right internal jugular vein, suspected based upon patient history and physical examination and confirmed by point-of-care ultrasound (POCUS). We then review the presentation, causes, and diagnostic standards for PSS. CASE REPORT: We present a case of a 79-year-old man who presented to the Emergency Department with acute right-sided neck pain 1 day after playing the saxophone for 4 h the prior evening. POCUS confirmed Paget-Schroetter syndrome, or primary effort thrombosis of the internal jugular vein. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: To our knowledge, this is the first documented case of PSS resulting from venous stasis with prolonged Valsalva maneuver and vascular trauma with activity of playing the saxophone. The significance of this case is the unusual etiology of a rare presentation and the ability to diagnose this condition quickly and accurately with POCUS.


Asunto(s)
Música , Trombosis Venosa Profunda de la Extremidad Superior/complicaciones , Trombosis de la Vena/etiología , Anciano , Anticoagulantes/uso terapéutico , Servicio de Urgencia en Hospital/organización & administración , Humanos , Venas Yugulares/fisiopatología , Masculino , Sistemas de Atención de Punto/tendencias , Ultrasonografía/métodos , Trombosis Venosa Profunda de la Extremidad Superior/fisiopatología , Trombosis de la Vena/fisiopatología
15.
Clin Pract Cases Emerg Med ; 2(4): 300-303, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30443611

RESUMEN

Aortic dissections have a vast array of clinical presentations that rarely follow traditional teachings. Dissections are rapidly fatal conditions requiring immediate diagnosis and treatment to reduce morbidity and mortality. We present a case of an acute aortic dissection presenting as abrupt onset, atraumatic leg pain with absent distal extremity pulses. The prompt use of point-of-care ultrasound detected an intimal flap within the abdominal aorta allowing immediate surgical consultation and intervention.

16.
Clin Pract Cases Emerg Med ; 2(2): 169-170, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29849272
17.
J Emerg Med ; 55(1): e1-e4, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29753570

RESUMEN

BACKGROUND: Febrile urinary tract infections (UTIs) include a spectrum of pathologies from uncomplicated pyelonephritis to urosepsis, including xanthogranulomatous pyelonephritis (XGP). Most febrile UTIs are treated with antibiotics alone, but studies indicate nearly 12% of cases of presumed simple pyelonephritis require emergent urologic intervention. How to identify these individuals, while limiting unnecessary advanced imaging and delays in diagnosis, challenges all emergency providers. We review the diagnosis and management of XGP, as well as the evidence regarding the role of renal ultrasound in the identification of complicated presentations of febrile UTIs. CASE REPORT: We present a case of XGP, a complicated febrile UTI requiring immediate urologic intervention, diagnosed by point-of-care ultrasound. A 40-year-old female presented in severe sepsis and complaining of flank pain. Prompt bedside ultrasound demonstrated hydronephrosis, expediting definitive urologic treatment via percutaneous nephrostomy tube placement. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: With a mortality rate exceeding 40%, obstructed pyonephrosis requires prompt decompression. Given its exceptional sensitivity for identifying hydronephrosis and ability to detect abscesses and emphysematous changes, we advocate a point-of-care ultrasound-first approach to screen for cases of complicated febrile UTIs in order to expedite treatment and limit radiation in uncomplicated presentations.


Asunto(s)
Pielonefritis Xantogranulomatosa/diagnóstico , Ultrasonografía/métodos , Adulto , Antibacterianos/uso terapéutico , Servicio de Urgencia en Hospital/organización & administración , Femenino , Dolor en el Flanco/etiología , Humanos , Sistemas de Atención de Punto , Pielonefritis Xantogranulomatosa/diagnóstico por imagen , Pielonefritis Xantogranulomatosa/mortalidad , Sepsis/tratamiento farmacológico , Sepsis/etiología
19.
Acad Emerg Med ; 22(5): 597-9, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25900052
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA