Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Opt Lett ; 46(7): 1788-1791, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33793544

RESUMEN

Existing streak-camera-based two-dimensional (2D) ultrafast imaging techniques are limited by long acquisition time, the trade-off between spatial and temporal resolutions, and a reduced field of view. They also require additional components, customization, or active illumination. Here we develop compressed ultrafast tomographic imaging (CUTI), which passively records 2D transient events with a standard streak camera. By grafting the concept of computed tomography to the spatiotemporal domain, the operations of temporal shearing and spatiotemporal integration in a streak camera's data acquisition can be equivalently expressed as the spatiotemporal projection of an (x,y,t) datacube from a certain angle. Aided by a new, to the best of our knowledge, compressed-sensing reconstruction algorithm, the 2D transient event can be accurately recovered in a few measurements. CUTI is exhibited as a new imaging mode universally adaptable to most streak cameras. Implemented in an image-converter streak camera, CUTI captures the sequential arrival of two spatially modulated ultrashort ultraviolet laser pulses at 0.5 trillion frames per second. Applied to a rotating-mirror streak camera, CUTI records an amination of fast-bouncing balls at 5,000 frames per second.

2.
Opt Express ; 27(26): 38435-38450, 2019 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-31878611

RESUMEN

In conventional laser-scanning microscopy, images are formed by acquiring the signal from pixel to pixel. Here, we report more than one order of magnitude reduction in acquisition time of Interferometric Second Harmonic Generation (I-SHG) by scanning the phase within each pixel, to characterize the relative polarity of various samples. Using an electro-optic phase-scanner, we show that the phase-shift patterns required for interferometry can be applied at each pixel during the scanning of the sample, allowing single-scan I-SHG (1S-ISHG) measurements. Requiring exposure times comparable to standard SHG intensity images, the additional phase information of the signal can thus be retrieved in parallel to its amplitude at the time-scale of seconds. Moreover, slower modulations can be used to enhance the precision of the phase measurement, without any spatial or temporal shift between interferograms, in contrast to conventional frame phase-shifting I-SHG (standard I-SHG). This continues to extend I-SHG to dynamical processes, and opens it to large-scale studies, as well as to imaging samples where the signal-to-noise ratio is an issue.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...