Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Bioanalysis ; 11(18s): 1-228, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31565956

RESUMEN

The 13th GCC Closed Forum for Bioanalysis was held in New Orleans, Louisiana, USA on April 5th, 2019. This GCC meeting was organized to discuss the contents of the 2019 ICH M10 Bioanalytical Method Validation Draft Guideline published in February 2019 and consolidate the feedback of the GCC members. In attendance were 63 senior-level participants from eight countries representing 44 bioanalytical CRO companies/sites. This event represented a unique opportunity for CRO bioanalytical experts to share their opinions and concerns regarding the ICH M10 Bioanalytical Method Validation Draft Guideline and to build unified comments to be provided to the ICH.


Asunto(s)
Biomarcadores/análisis , Guías como Asunto , Humanos , Reproducibilidad de los Resultados , Proyectos de Investigación
2.
Bioanalysis ; 11(12): 1129-1138, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31319683

RESUMEN

The 12th GCC Closed Forum was held in Philadelphia, PA, USA, on 9 April 2018. Representatives from international bioanalytical Contract Research Organizations were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at the meeting included: critical reagents; oligonucleotides; certificates of analysis; method transfer; high resolution mass spectrometry; flow cytometry; recent regulatory findings and case studies involving stability and nonclinical immunogenicity. Conclusions and consensus from discussions of these topics are included in this article.


Asunto(s)
Certificación , Técnicas de Química Analítica , Citometría de Flujo , Espectrometría de Masas , Oligonucleótidos/análisis , Control Social Formal , Sociedades Científicas , Indicadores y Reactivos/química
3.
Bioanalysis ; 11(7): 645-653, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30993999

RESUMEN

Over the last decade, the use of biomarker data has become integral to drug development. Biomarkers are not only utilized for internal decision-making by sponsors; they are increasingly utilized to make critical decisions for drug safety and efficacy. As the regulatory agencies are routinely making decisions based on biomarker data, there has been significant scrutiny on the validation of biomarker methods. Contract research organizations regularly use commercially available immunoassay kits to validate biomarker methods. However, adaptation of such kits in a regulated environment presents significant challenges and was one of the key topics discussed during the 12th Global Contract Research Organization Council for Bioanalysis (GCC) meeting. This White Paper reports the GCC members' opinion on the challenges facing the industry and the GCC recommendations on the classification of commercial kits that can be a win-win for commercial kit vendors and end users.


Asunto(s)
Bioensayo/métodos , Biomarcadores/análisis , Bioensayo/normas , Descubrimiento de Drogas , Humanos , Ligandos , Preparaciones Farmacéuticas/química , Preparaciones Farmacéuticas/metabolismo , Preparaciones Farmacéuticas/normas , Control de Calidad , Juego de Reactivos para Diagnóstico , Estándares de Referencia , Sociedades Farmacéuticas , Encuestas y Cuestionarios
4.
Bioanalysis ; 10(7): 433-444, 2018 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-29701066

RESUMEN

The 11th Global CRO Council Closed Forum was held in Universal City, CA, USA on 3 April 2017. Representatives from international CRO members offering bioanalytical services were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The second CRO-Pharma Scientific Interchange Meeting was held on 7 April 2017, which included Pharma representatives' sharing perspectives on the topics discussed earlier in the week with the CRO members. The issues discussed at the meetings included cumulative stability evaluations, matrix stability evaluations, the 2016 US FDA Immunogenicity Guidance and recent and unexpected FDA Form 483s on immunogenicity assays, the bioanalytical laboratory's role in writing PK sample collection instructions, biosimilars, CRO perspectives on the use of chiral versus achiral methods, hybrid LBA/LCMS assays, applications of fit-for-purpose validation and, at the Global CRO Council Closed Forum only, the status and trend of current regulated bioanalytical practice in China under CFDA's new BMV policy. Conclusions from discussions of these topics at both meetings are included in this report.


Asunto(s)
Bioensayo/métodos , Biomarcadores/análisis , Biosimilares Farmacéuticos/uso terapéutico , China , Humanos , Proyectos de Investigación
5.
Bioanalysis ; 9(7): 505-516, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28339299

RESUMEN

The 10th Global CRO Council (GCC) Closed Forum was held in Orlando, FL, USA on 18 April 2016. In attendance were decision makers from international CRO member companies offering bioanalytical services. The objective of this meeting was for GCC members to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at this closed forum included reporting data from failed method validation runs, GCP for clinical sample bioanalysis, extracted sample stability, biomarker assay validation, processed batch acceptance criteria, electronic laboratory notebooks and data integrity, Health Canada's Notice regarding replicates in matrix stability evaluations, critical reagents and regulatory approaches to counteract fraud. In order to obtain the pharma perspectives on some of these topics, the first joint CRO-Pharma Scientific Interchange Meeting was held on 12 November 2016, in Denver, Colorado, USA. The five topics discussed at this Interchange meeting were reporting data from failed method validation runs, GCP for clinical sample bioanalysis, extracted sample stability, processed batch acceptance criteria and electronic laboratory notebooks and data integrity. The conclusions from the discussions of these topics at both meetings are included in this report.


Asunto(s)
Biomarcadores/análisis , Técnicas de Química Analítica/normas , Recolección de Datos/normas , Guías como Asunto , Preparaciones Farmacéuticas/análisis , Estabilidad de Medicamentos , Regulación Gubernamental , Humanos , Informe de Investigación
6.
Bioanalysis ; 8(6): 487-95, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26916197

RESUMEN

The 9th GCCClosed Forum was held just prior to the 2015 Workshop on Recent Issues in Bioanalysis (WRIB) in Miami, FL, USA on 13 April 2015. In attendance were 58 senior-level participants, from eight countries, representing 38 CRO companies offering bioanalytical services. The objective of this meeting was for CRO bioanalytical representatives to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues selected at this year's closed forum include CAPA, biosimilars, preclinical method validation, endogenous biomarkers, whole blood stability, and ELNs. A summary of the industry's best practices and the conclusions from the discussion of these topics is included in this meeting report.


Asunto(s)
Biomarcadores/análisis , Biosimilares Farmacéuticos/análisis , Evaluación Preclínica de Medicamentos/métodos , Biomarcadores/sangre , Registros Electrónicos de Salud , Laboratorios , Sociedades Médicas , Estudios de Validación como Asunto
7.
Bioanalysis ; 6(18): 2385-90, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25384591

RESUMEN

The topic of incurred sample stability (ISS) has generated considerable discussion within the bioanalytical community in recent years. The subject was an integral part of the seventh annual Workshop on Recent Issues in Bioanalysis (WRIB) held in Long Beach, CA, USA, in April 2013, and at the Global CRO Council for Bioanalysis (GCC) meeting preceding it. Discussion at both events focused on the use of incurred samples for ISS purposes in light of results from a recent GCC survey completed by member companies. This paper reports the consensus resulting from these discussions and serves as a useful reference for depicting ISS issues and concerns, summarizing the GCC survey results and providing helpful recommendations on ISS in the context of bioanalytical method development and application.


Asunto(s)
Pruebas de Química Clínica , Recolección de Datos , Reproducibilidad de los Resultados
10.
Bioanalysis ; 4(17): 2117-26, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23013394

RESUMEN

An open letter written by the Global CRO Council for Bioanalysis (GCC) describing the GCC survey results on stability data from co-administered and co-formulated drugs was sent to multiple regulatory authorities on 14 December 2011. This letter and further discussions at different GCC meetings led to subsequent recommendations on this topic of widespread interest within the bioanalytical community over the past 2 years.


Asunto(s)
Combinación de Medicamentos , Preparaciones Farmacéuticas/análisis , Tecnología Farmacéutica/normas , Biomarcadores/análisis , Cromatografía Líquida de Alta Presión/métodos , Estabilidad de Medicamentos , Regulación Gubernamental , Guías como Asunto , Humanos , Espectrometría de Masas en Tándem/métodos
12.
Bioanalysis ; 4(7): 763-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22512795

RESUMEN

The Global CRO Council for Bioanalysis (GCC) was formed in September 2010. Since then, the representatives of the member companies come together periodically to openly discuss bioanalysis and the regulatory challenges unique to the outsourcing industry. The 4th GCC Closed Forum brought together experts from bioanalytical CROs to share and discuss recent issues in regulated bioanalysis, such as the impact of coadministered drugs on stability, some differences between European Medicines Agency and US FDA bioanalytical guidance documents and lessons learned following recent Untitled Letters. Recent 483s and agency findings, as well as issues on method carryover, were also part of the topics discussed.


Asunto(s)
Técnicas de Química Analítica/normas , Guías como Asunto , Organizaciones sin Fines de Lucro/normas , United States Food and Drug Administration/normas , Métodos Analíticos de la Preparación de la Muestra , Calibración , Química Farmacéutica , Documentación , Combinación de Medicamentos , Estabilidad de Medicamentos , Europa (Continente) , Estándares de Referencia , Reproducibilidad de los Resultados , Estados Unidos
14.
Bioanalysis ; 3(24): 2721-7, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22185271

RESUMEN

The 3rd Global CRO Council Closed Forum was held on the 3rd and 4th July 2011 in Guildford, United Kingdom, in conjunction with the 19th International Reid Bioanalytical Forum. In attendance were 21 senior-level representatives from 19 CROs on behalf of nine European countries and, for many of the attendees, this occasion was the first time that they had participated in a GCC meeting. Therefore, this closed forum was an opportunity to increase awareness of the aim of the GCC and how it works, share information about bioanalytical regulations and audit findings from different agencies, their policies and procedures and also to discuss some topics of interest and aim to develop ideas and provide recommendations for bioanalytical practices at future GCC meetings in Europe.


Asunto(s)
Preparaciones Farmacéuticas/análisis , Tecnología Farmacéutica/organización & administración , Biomarcadores/análisis , Cromatografía Líquida de Alta Presión , Regulación Gubernamental , Hemólisis , Humanos , Espectrometría de Masas en Tándem
15.
Bioanalysis ; 2(12): 2001-9, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21110743

RESUMEN

BACKGROUND: Dapagliflozin is an inhibitor of sodium-glucose co-transporter 2 (SGLT-2) in development for the treatment of Type 2 diabetes. To support toxicology studies, LC-MS/MS methods were developed and validated for the quantitation of dapagliflozin in rat plasma. RESULTS: The assay uses solid phase extraction and LC-MS/MS analysis in negative ion electrospray ionization mode. Because dapagliflozin readily forms adducts in the presence of formic acid, the mobile phases were simple mixtures of water and acetonitrile. The assay was validated in the concentration range of 5-2000 ng/ml with good intra- and inter-day precisions and acceptable sample stability. CONCLUSION: The validated assay was successfully applied to the quantitation of dapagliflozin in plasma in support of preclinical studies in both normal and diabetic rats.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Modelos Animales de Enfermedad , Inhibidores Enzimáticos/sangre , Glucósidos/sangre , Espectrometría de Masas/métodos , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Acetonitrilos/química , Animales , Compuestos de Bencidrilo , Inhibidores Enzimáticos/metabolismo , Glucósidos/metabolismo , Ratas , Ratas Zucker , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Transportador 2 de Sodio-Glucosa/metabolismo , Extracción en Fase Sólida/métodos , Agua/química
16.
Artículo en Inglés | MEDLINE | ID: mdl-15922678

RESUMEN

Zalcitabine (ddC), lamivudine (3TC), didanosine (ddI), stavudine (d4T), carbovir (CBV), zidovudine (AZT), tenofovir (PMPA) and its administrated form (tenofovir diisoproxyl fumarate, TDF), are nucleosides currently approved in HIV therapy. To facilitate pharmacokinetics studies, a specific reversed-phase high-performance liquid chromatography (HPLC) method was developed for their analysis in rat plasma. The method involved a quantitative recovery of these drugs from rat plasma by solid-phase extraction on Oasis HLB Waters cartridges followed by optimised HPLC separation on an Atlantis dC18 column with acetic acid-hydroxylamine buffer (ionic strength 5mM, pH 7)-acetonitrile elution gradient. Quantitation was performed by HPLC/UV at 260 nm. Linear calibration curves were obtained within a 30-10,000 ng/mL plasma concentration range. Correlation coefficients (r2) greater than 0.992 were obtained by least-squares regression and limits of quantification were in 30-90 ng/mL concentration range. Quantitative parameters (accuracy, intra-day repeatability and inter-day reproducibility) yielded satisfactory results. Finally, a new buffer, obtained with acetic acid and hydroxylamine, has been tested in HPLC/ESI-MS/MS and appears to be an efficient volatile buffer in the medium 5-7 pH range. Indeed, at pH 7 and low ionic strength (5 mM), its buffer capacity is one hundred times higher to that obtained for the usual acetic acid/ammonia buffer.


Asunto(s)
Antirretrovirales/sangre , Cromatografía Líquida de Alta Presión/métodos , Didesoxinucleósidos/sangre , Espectrometría de Masa por Ionización de Electrospray/métodos , Ácido Acético/química , Animales , Tampones (Química) , Concentración de Iones de Hidrógeno , Hidroxilamina/química , Ratas , Espectrofotometría Ultravioleta
17.
J Mass Spectrom ; 38(8): 879-90, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12938109

RESUMEN

The pharmacokinetics of intracellular drugs have recently aroused new interest because monitoring a drug's behaviour near the site of action can enhance knowledge of its efficacy and toxicity. Liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) is particularly attractive for intracellular analytes. Very few papers deal precisely with special features encountered in intracellular drug assay or with how closely the assay matches the actual recommendations. Particular problems are encountered mainly because the analytes are located intracellularly. This mainly concerns the handling of biological media, including provision of blank samples using Ficoll gradient separation, cell counts, optimisation of cell lysis, sample extraction, plotting standard curves using either fmol/10(6) cells or fmol/ml of extract or fmol/sample, the matrix effect as a function of the number of cells, stability before and during cell separation, as well as in storage conditions using clinical samples, biological matrix replacement and interference by endogenous compounds. This paper describes a strategy for the full validation and routine use of an LC/MS/MS assay applied to the simultaneous intracellular determination of the triphosphorylated anabolites of didanosine (2',3'-dideoxyadenosine triphosphate or ddA-TP) and stavudine (2',3'-didehydro-3'-deoxythymidine triphosphate or d4T-TP), two nucleoside reverse transcriptase inhibitors of HIV, in human peripheral blood mononuclear cells (PBMCs), as a guide for further LC/MS/MS assay of intracellular drugs.


Asunto(s)
Fármacos Anti-VIH/farmacocinética , Cromatografía Líquida de Alta Presión/métodos , Didanosina/farmacocinética , Leucocitos Mononucleares/metabolismo , Espectrometría de Masa por Ionización de Electrospray/métodos , Estavudina/farmacocinética , Didanosina/análisis , Didesoxiadenosina/análisis , Leucocitos Mononucleares/química , Estavudina/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA