Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Am Anim Hosp Assoc ; 55(2): e55204, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30653363

RESUMEN

A 12 yr old male neutered beagle was presented on transfer to the intensive care unit with severe anemia, thrombocytopenia, and bruising detected 1 day after undergoing tibial plateau leveling osteotomy surgery. The patient had undergone extra-capsular stifle stabilization surgery 14 wk prior to treat ligament disease in the same knee. Laboratory testing and treatment for anemia, presumptive immune-mediated thrombocytopenia, and possible hemostatic disorder was initiated. A persistent anemia, progressive thrombocytopenia, and the development of a firm swelling and neurologic impairment in the limb raised concerns for compartment syndrome (CS). A musculoskeletal ultrasound revealed a large aneurysm in the caudal thigh surrounded by abnormal muscle tissue. The patient underwent amputation of the limb and recovered without further complication. Pathology findings were consistent with the development of femoral CS secondary to a ruptured peripheral arterial aneurysm or a pseudoaneurysm. A consumptive thrombocytopenia and regenerative anemia were attributed to periodic or progressive thrombosis of the vessel and regional hemorrhage. Postoperative CS can develop in combination with peripheral arterial aneurysm or pseudoaneurysm, and screening for vascular abnormalities as well as CS should be considered in complicated recovery from orthopedic surgery with compatible clinical signs including progressive soft tissue swelling, persistent anemia, and thrombocytopenia.


Asunto(s)
Anemia/veterinaria , Aneurisma Roto/veterinaria , Síndromes Compartimentales/veterinaria , Enfermedades de los Perros/patología , Trombocitopenia/veterinaria , Amputación Quirúrgica/veterinaria , Anemia/etiología , Aneurisma Falso/veterinaria , Aneurisma Roto/complicaciones , Animales , Síndromes Compartimentales/etiología , Síndromes Compartimentales/patología , Enfermedades de los Perros/diagnóstico , Enfermedades de los Perros/etiología , Perros , Miembro Posterior/patología , Miembro Posterior/cirugía , Masculino , Rodilla de Cuadrúpedos/cirugía , Trombocitopenia/etiología
2.
J Med Primatol ; 47(3): 192-197, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29504143

RESUMEN

Disorders of sexual development are rare in non-human primates. We report a case of true hermaphroditism in a 19-year-old, nulliparous, female baboon (Papio spp.). At necropsy, the animal was obese with adequate muscle mass and hydration. Reproductive organs appeared normal with the exception of 2 firm nodular structures in the myometrium (1-1.5 cm diameter) and a thickened, dark endocervical mucosa. Histologically, both gonads were ovotestes and contained discrete areas of ovarian and testicular tissue. There were follicles in various stages of development surrounded by ovarian stroma. Other areas contained hypoplastic seminiferous tubules lined by Sertoli cells, but lacked germ cells and spermatozoa. The uterine lesions were consistent with adenomyosis and cystic endometrial hyperplasia. Cervical lesions were consistent with atypical glandular hyperplasia and squamous metaplasia with dysplasia. We report the first case of ovotesticular disorder of sexual development (OT-DSD), or true hermaphroditism in a baboon.


Asunto(s)
Enfermedades de los Monos/patología , Trastornos Ovotesticulares del Desarrollo Sexual/patología , Papio , Animales , Femenino
3.
Appl Radiat Isot ; 122: 222-228, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28189025

RESUMEN

Mass-separated francium beams (211Fr or 213Fr) were implanted into solid targets for producing 211Rn (14.6h half-life) or 209At (5.41h), in situ. 211Rn was transferred to dodecane and isolated from contaminants, providing sources for 211At (7.21h) production by 211Rn decay (73%). 209At was recovered with high radionuclidic purity in aqueous solutions, directly. These experiments demonstrated Fr beam implantations as a novel method for producing preclinical quantities of 211Rn/211At (for therapy) and 209At (for imaging).


Asunto(s)
Astato/química , Francio/química , Radón/química , Astato/uso terapéutico , Diagnóstico por Imagen/métodos , Semivida , Peso Molecular , Soluciones , Agua
4.
Nucl Med Biol ; 48: 31-35, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28193502

RESUMEN

INTRODUCTION: The availability of 211At for targeted alpha therapy research can be increased by the 211Rn/211At generator system, whereby 211At is produced by 211Rn electron capture decay. This study demonstrated the feasibility of using generator-produced 211At to label monoclonal antibody (BC8, anti-human CD45) for preclinical use, following isolation from the 207Po contamination also produced by these generators (by 211Rn α-decay). METHODS: 211Rn was produced by 211Fr electron capture decay following mass separated ion beam implantation and chemically isolated in liquid alkane hydrocarbon (dodecane). 211At produced by the resulting 211Rn source was extracted in strong base (2N NaOH) and purified by granular Te columns. BC8-B10 (antibody conjugated with closo-decaborate(2-)) was labeled with generator-produced 211At and purified by PD-10 columns. RESULTS: Aqueous solutions extracted from the generator were found to contain 211At and 207Po, isolated from 211Rn. High radionuclidic purity was obtained for 211At eluted from Te columns, from which BC8-B10 monoclonal antibody was successfully labeled. If not removed, 207Po was found to significantly contaminate the final 211At-BC8-B10 product. High yield efficiencies (decay-corrected, n=3) were achieved for 211At extraction from the generator (86%±7%), Te column purification (70%±10%), and antibody labeling (76%±2%). CONCLUSIONS: The experimental 211Rn/211At generator was shown to be well-suited for preclinical 211At-based research. ADVANCES IN KNOWLEDGE: We believe that these experiments have furthered the knowledge-base for expanding accessibility to 211At using the 211Rn/211At generator system. IMPLICATIONS FOR PATIENT CARE: As established by this work, the 211Rn/211At generator has the capability of facilitating preclinical evaluations of 211At-based therapies.


Asunto(s)
Partículas alfa/uso terapéutico , Astato/química , Astato/uso terapéutico , Radioquímica/instrumentación , Radón/química , Astato/aislamiento & purificación , Inmunoconjugados/uso terapéutico , Marcaje Isotópico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA