Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 9 de 9
1.
Environ Health Perspect ; 132(3): 37007, 2024 Mar.
Article En | MEDLINE | ID: mdl-38534131

BACKGROUND: Chronic arsenic exposure has been associated with an increased risk of cardiovascular disease; diabetes; cancers of the lung, pancreas and prostate; and all-cause mortality in American Indian communities in the Strong Heart Study. OBJECTIVE: The Strong Heart Water Study (SHWS) designed and evaluated a multilevel, community-led arsenic mitigation program to reduce arsenic exposure among private well users in partnership with Northern Great Plains American Indian Nations. METHODS: A cluster randomized controlled trial (cRCT) was conducted to evaluate the effectiveness of the SHWS arsenic mitigation program over a 2-y period on a) urinary arsenic, and b) reported use of arsenic-safe water for drinking and cooking. The cRCT compared the installation of a point-of-use arsenic filter and a mobile Health (mHealth) program (3 phone calls; SHWS mHealth and Filter arm) to a more intensive program, which included this same program plus three home visits (3 phone calls and 3 home visits; SHWS Intensive arm). RESULTS: A 47% reduction in urinary arsenic [geometric mean (GM)=13.2 to 7.0µg/g creatinine] was observed from baseline to the final follow-up when both study arms were combined. By treatment arm, the reduction in urinary arsenic from baseline to the final follow-up visit was 55% in the mHealth and Filter arm (GM=14.6 to 6.55µg/g creatinine) and 30% in the Intensive arm (GM=11.2 to 7.82µg/g creatinine). There was no significant difference in urinary arsenic levels by treatment arm at the final follow-up visit comparing the Intensive vs. mHealth and Filter arms: GM ratio of 1.21 (95% confidence interval: 0.77, 1.90). In both arms combined, exclusive use of arsenic-safe water from baseline to the final follow-up visit significantly increased for water used for cooking (17% to 53%) and drinking (12% to 46%). DISCUSSION: Delivery of the interventions for the community-led SHWS arsenic mitigation program, including the installation of a point-of-use arsenic filter and a mHealth program on the use of arsenic-safe water (calls only, no home visits), resulted in a significant reduction in urinary arsenic and increases in reported use of arsenic-safe water for drinking and cooking during the 2-y study period. These results demonstrate that the installation of an arsenic filter and phone calls from a mHealth program presents a promising approach to reduce water arsenic exposure among private well users. https://doi.org/10.1289/EHP12548.


Arsenic , Drinking Water , Humans , American Indian or Alaska Native , Arsenic/urine , Creatinine , Drinking Water/chemistry , Telemedicine
2.
Environ Health ; 22(1): 42, 2023 05 15.
Article En | MEDLINE | ID: mdl-37183246

BACKGROUND: The objective of this study was to evaluate the behavioral determinants associated with exclusive use of arsenic-safe water in the community-led Strong Heart Water Study (SHWS) arsenic mitigation program. METHODS: The SHWS is a randomized controlled trial of a community-led arsenic mitigation program designed to reduce arsenic exposure among private well users in American Indian Great Plains communities. All households received point-of-use (POU) arsenic filters installed at baseline and were followed for 2 years. Behavioral determinants selected were those targeted during the development of the SHWS program, and were assessed at baseline and follow-up. RESULTS: Among participants, exclusive use of arsenic-safe water for drinking and cooking at follow-up was associated with higher self-efficacy for accessing local resources to learn about arsenic (OR: 5.19, 95% CI: 1.48-18.21) and higher self-efficacy to resolve challenges related to arsenic in water using local resources (OR: 3.11, 95% CI: 1.11-8.71). Higher commitment to use the POU arsenic filter faucet at baseline was also a significant predictor of exclusive arsenic-safe water use for drinking (OR: 32.57, 95% CI: 1.42-746.70) and cooking (OR: 15.90, 95% CI: 1.33-189.52) at follow-up. From baseline to follow-up, the SHWS program significantly increased perceived vulnerability to arsenic exposure, self-efficacy, descriptive norms, and injunctive norms. Changing one's arsenic filter cartridge after installation was associated with higher self-efficacy to obtain arsenic-safe water for drinking (OR: 6.22, 95% CI: 1.33-29.07) and cooking (OR: 10.65, 95% CI: 2.48-45.68) and higher perceived vulnerability of personal health effects (OR: 7.79, 95% CI: 1.17-51.98) from drinking arsenic-unsafe water. CONCLUSIONS: The community-led SHWS program conducted a theory-driven approach for intervention development and evaluation that allowed for behavioral determinants to be identified that were associated with the use of arsenic safe water and changing one's arsenic filter cartridge. These results demonstrate that theory-driven, context-specific formative research can influence behavior change interventions to reduce water arsenic exposure. The SHWS can serve as a model for the design of theory-driven intervention approaches that engage communities to reduce arsenic exposure. TRIAL REGISTRATION: The SHWS is registered with ClinicalTrials.gov (Identifier: NCT03725592).


Arsenic , Drinking Water , Water Pollutants, Chemical , Humans , Arsenic/analysis , Water Pollutants, Chemical/analysis , Water Supply
3.
Sci Total Environ ; 862: 160217, 2023 Mar 01.
Article En | MEDLINE | ID: mdl-36410482

Many rural populations, including American Indian communities, that use private wells from groundwater for their source of drinking and cooking water are disproportionately exposed to elevated levels of arsenic. However, programs aimed at reducing arsenic in American Indian communities are limited. The Strong Heart Water Study (SHWS) is a randomized controlled trial aimed at reducing arsenic exposure among private well users in American Indian Northern Great Plains communities. The community-led SHWS program installed point-of-use (POU) arsenic filters in the kitchen sink of households, and health promoters delivered arsenic health communication programs. In this study we evaluated the efficacy of these POU arsenic filters in removing arsenic during the two-year installation period. Participants were randomized into two arms. In the first arm households received a POU arsenic filter, and 3 calls promoting filter use (SHWS mobile health (mHealth) & filter arm). The second arm received the same filter and phone calls, and 3 in-person home visits and 3 Facebook messages (SHWS intensive arm) for program delivery. Temporal variability in water arsenic concentrations from the main kitchen faucet was also evaluated. A total of 283 water samples were collected from 50 households with private wells from groundwater (139 filter and 144 kitchen faucet samples). Ninety-three percent of households followed after baseline had filter faucet water arsenic concentrations below the arsenic maximum contaminant level of 10 µg/L at the final visit during our 2 year study period with no difference between study arms (98 % in the intensive arm vs. 94 % in the mHealth & filter arm). No significant temporal variation in kitchen arsenic concentration was observed over the study period (intraclass correlation coefficient = 0.99). This study demonstrates that POU arsenic filters installed for the community participatory SHWS program were effective in reducing water arsenic concentration in study households in both arms, even with delivery of the POU arsenic filter and mHealth program only. Furthermore, we observed limited temporal variability of water arsenic concentrations from kitchen faucet samples collected over time from private wells in our study setting.


Arsenic , Drinking Water , Water Pollutants, Chemical , Humans , Arsenic/analysis , Environmental Monitoring , Water , American Indian or Alaska Native , Water Wells , Water Pollutants, Chemical/analysis , Water Supply , Drinking Water/analysis
4.
ACS ES T Water ; 2(10): 1772-1788, 2022 Oct 14.
Article En | MEDLINE | ID: mdl-36277121

In the United States (US), private-supply tapwater (TW) is rarely monitored. This data gap undermines individual/community risk-management decision-making, leading to an increased probability of unrecognized contaminant exposures in rural and remote locations that rely on private wells. We assessed point-of-use (POU) TW in three northern plains Tribal Nations, where ongoing TW arsenic (As) interventions include expansion of small community water systems and POU adsorptive-media treatment for Strong Heart Water Study participants. Samples from 34 private-well and 22 public-supply sites were analyzed for 476 organics, 34 inorganics, and 3 in vitro bioactivities. 63 organics and 30 inorganics were detected. Arsenic, uranium (U), and lead (Pb) were detected in 54%, 43%, and 20% of samples, respectively. Concentrations equivalent to public-supply maximum contaminant level(s) (MCL) were exceeded only in untreated private-well samples (As 47%, U 3%). Precautionary health-based screening levels were exceeded frequently, due to inorganics in private supplies and chlorine-based disinfection byproducts in public supplies. The results indicate that simultaneous exposures to co-occurring TW contaminants are common, warranting consideration of expanded source, point-of-entry, or POU treatment(s). This study illustrates the importance of increased monitoring of private-well TW, employing a broad, environmentally informative analytical scope, to reduce the risks of unrecognized contaminant exposures.

5.
J Antimicrob Chemother ; 60(6): 1258-63, 2007 Dec.
Article En | MEDLINE | ID: mdl-17934203

OBJECTIVES: The aim of this paper is to attribute Panton-Valentine leucocidin (PVL)-positive methicillin-resistant Staphylococcus aureus (MRSA) to clonal lineages by molecular typing with special reference to isolates exhibiting spa type t008/multilocus sequence type (MLST) ST8 [widely disseminated in the USA as 'community-associated MRSA (caMRSA) USA300']. METHODS: PVL-positive MRSA (n = 117) were detected among 4815 MRSA sent to the German National Reference Laboratory for typing. These isolates were analysed by PFGE, spa typing, multilocus sequence typing, grouping of SCCmec elements and PCR detection of arcA, msr(A), mph(B) and the > or =6 AT repeat unit in the SACOL0058 sequence. RESULTS: Among the 117 isolates, 80 exhibited spa type t044 (corresponding to MLST ST80) and 23 exhibited spa type t008/MLST ST8. Other spa types were sporadically represented. Further characterization of isolates exhibiting t008/ST8 by PCR [arcA, msr(A), mph(B), > or =6 AT repeat signature] indicates the arrival of caMRSA 'USA300' in Central Europe. CONCLUSIONS: caMRSA ST80 still predominate; however, caMRSA ST8 exhibiting the characteristics of the 'USA300' clone became the second most frequent. Routine detection of this clone in clinical bacteriology can be easily performed by PCR.


Bacterial Toxins/genetics , Community-Acquired Infections/epidemiology , Exotoxins/genetics , Leukocidins/genetics , Methicillin Resistance , Staphylococcal Infections/epidemiology , Staphylococcus aureus/classification , Antigens, Bacterial/genetics , Bacterial Typing Techniques , Community-Acquired Infections/microbiology , Genotype , Germany/epidemiology , Humans , Polymerase Chain Reaction/methods , Staphylococcal Infections/microbiology , Staphylococcus aureus/drug effects , Staphylococcus aureus/genetics
6.
J Antimicrob Chemother ; 57(3): 461-5, 2006 Mar.
Article En | MEDLINE | ID: mdl-16387748

OBJECTIVES: Methicillin-resistant Staphylococcus aureus (MRSA) isolates from pet animals were characterized and compared with human isolates from clonal complexes most prevalent in Central Europe. METHODS: S. aureus isolates were investigated for their in vitro susceptibility to antimicrobial agents by broth microdilution. Resistance genes and the Panton-Valentine leucocidin gene lukF-lukS were identified by PCR. All isolates were characterized by SmaI macrorestriction analysis and spa typing to assess their genomic relationships. Representative isolates were additionally analysed by multilocus sequence typing and PCR-directed SCCmec typing. RESULTS: All pet isolates carried the resistance genes mecA and erm(C) and proved to be resistant to beta-lactams and MLS(B) antibiotics. In addition, all isolates were resistant to fluoroquinolones. None of the pet isolates carried the Panton-Valentine leucocidin gene lukF-lukS. Macrorestriction analysis revealed that the pet MRSA isolates exhibited four closely related SmaI fragment patterns. Moreover, all isolates revealed spa type t032. Further analysis of representatives of the different PFGE types revealed the presence of multilocus sequence type ST22 in combination with a type IV SCCmec element. Thus, molecular typing results were similar for pet strains and human ST22 reference strains. CONCLUSIONS: Based on their strain characteristics, the MRSA isolates from pets investigated in this study closely resembled ST22 MRSA isolates which are widely disseminated in German hospitals. The results of this study indicate that cross-transmission of MRSA between pet animals and humans might have occurred.


Cat Diseases/microbiology , Dog Diseases/microbiology , Methicillin Resistance , Staphylococcal Infections/microbiology , Staphylococcal Infections/veterinary , Staphylococcus aureus/drug effects , Animals , Cats , Dogs , Genotype , Humans , Molecular Epidemiology , Phenotype , Phylogeny , Staphylococcus aureus/genetics
7.
J Microbiol Methods ; 51(1): 19-28, 2002 Sep.
Article En | MEDLINE | ID: mdl-12069886

The reproducibility of the binary typing (BT) protocol developed for epidemiological typing of Staphylococcus aureus was analyzed in a biphasic multicenter study. In a Dutch multicenter pilot study, 10 genetically unique isolates of methicillin-resistant S. aureus (MRSA) were characterized by the BT assay as presented by van Leeuwen et al. [J. Clin. Microbiol. 2001 39 (1) 328]. The BT assay, including a standardized DNA extraction protocol was performed in duplicate in eleven medical microbiology laboratories. Two different hybridization detection procedures were applied and a prelabeled DNA sample as process control was included. Only three laboratories accurately identified all strains. Divergence in technical procedures resulted in misinterpretation due to an increasing number of faint or absent hybridization signals in combination with high background staining. The binary type of the process control was determined correctly by all participating laboratories. The feasibility of the BT protocol was related directly to the skill of the laboratory personnel. On the basis of the national study, we concluded that the DNA extraction protocol needed modification to improve DNA yield and purity. Subsequently, seven European laboratories participated in an international study to determine the reproducibility of the modified BT protocol. Each center was asked to analyze 10 DNA samples previously extracted from 10 MRSA strains (phase 1) and, additionally, to analyze 10 MRSA strains, using the standardized or their in-house DNA isolation protocol (phase 2). A prelabeled DNA process control sample was included again. The binary types of all DNA samples were identified correctly by all but one laboratories. This latter laboratory diverged from the protocol by adding an excess of labeled DNA to the hybridization mixture, resulting in a high background and, therefore, noninterpretable BT results. All centers produced identical BT results for the process control. Five of the seven centers correctly identified the binary types of all 10 MRSA strains in phase 2 of the international study. Three of these centers used their in-house DNA extraction protocol. Divergence from the standard BT protocol in the remaining two centers resulted in no interpretable BT data for the 10 MRSA strains. The study demonstrated that each center that followed the BT protocol to the letter could generate reproducible results, irrespective whether or not an in-house DNA isolation protocol was used. The current BT protocol thus represents a simple method generating robust, reproducible genotype data for S. aureus strains.


Bacterial Typing Techniques/standards , Nucleic Acid Hybridization/methods , Staphylococcus aureus/classification , Bacterial Typing Techniques/methods , DNA, Bacterial/chemistry , DNA, Bacterial/genetics , Europe , Methicillin Resistance , Pilot Projects , Reproducibility of Results , Staphylococcus aureus/genetics
9.
Clin Microbiol Infect ; 3(4): 414-422, 1997 Aug.
Article En | MEDLINE | ID: mdl-11864151

OBJECTIVE: to present data on prevalence and interregional spread of methicillin-resistant Staphylococcus aureus (MRSA) in Germany. METHODS: A nationwide collection of MRSA isolates from nosocomial infections in 143 hospitals was established from isolates (n=4368) sent to a microbiological reference center during 1993--95. As chosen by distinguishable resistance phenotypes at each time of occurrence during the study period, 1830 isolates were subjected to molecular typing by means of Smal macrorestriction patterns, PCR for RNA gene spacer patterns, and PCR for patterns of DNA stretches flanked by the ERIC-2 sequence and flanked by Tn916 and ribosomal binding site. In addition, data from a multicenter study on the incidence of antibiotic resistance have been analyzed (32 centers, 637 S. aureus isolates). RESULTS: In 1995 the prevalence of MRSA among S. aureus isolates was 8.7% overall in central Europe (including Germany), in comparison to 1.7% in 1990. From 1993 until now, a continuous interregional dissemination of six epidemic strains, which were identified by molecular typing, was recorded. Besides these epidemic strains, 15 MRSA strains were identified which could not be allocated to the epidemic MRSA or to the known clonal groups of the species S. aureus. MRSA from three cases of sporadic nosocomial infections exhibited characteristics of the clonal group of S. aureus with the capacity for toxic shock syndrome formation. The pattern of one MRSA corresponded to those of the S. aureus group exhibiting phage pattern 94,96. CONCLUSIONS: The prevalence of MRSA has increased in central Europe (and Germany) during the last 5 years, to 8.7%. The main source of infection with MRSA is obviously interregional dissemination of epidemic strains. At the same time, the mecA gene has been acquired by strains previously sensitive to methicillin.

...