Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Clin Chim Acta ; 520: 71-75, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34052205

RESUMEN

Dysbetalipoproteinemia (DBL) is an uncommon condition characterized by a mixed hyperlipidemia due to accumulation of remnant lipoproteins and is highly atherogenic. Typically, DBL is an autosomal recessive condition requiring an additional metabolic stress with reduced apolipoprotein E (apoE) function. However, DBL is also described in patients with multiple myeloma without the characteristic apoE2/E2 mutation seen in familial DBL. Although the underlying pathogenesis in these cases is not fully characterized, it is thought to occur due to interference with apoE function by antibodies produced from clonal plasma cells. Such cases are referred to as hyperlipidemic myeloma (HLM) and have rarely been described in the literature. To our knowledge there is no prior description of HLM in HIV positive patients in Africa. We describe a case of HLM in an African woman with underlying HIV infection who presented with phenotypic and biochemical features of DBL that responded poorly to lipid lowering therapy.


Asunto(s)
Infecciones por VIH , Hiperlipoproteinemia Tipo III , Mieloma Múltiple , África , Apolipoproteína E2 , Apolipoproteínas E , Femenino , Humanos , Hiperlipoproteinemia Tipo III/genética , Triglicéridos
3.
Clin Chem Lab Med ; 59(8): 1409-1420, 2021 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-33711217

RESUMEN

OBJECTIVES: The prevalence of chronic kidney disease is rising rapidly in low- and middle-income countries. Serum creatinine and estimation of glomerular filtration rate (GFR) are critical diagnostic tools, yet access to centralised laboratory services remains limited in primary care resource-limited settings. The aim of this study was to evaluate point-of-care (POC) technologies for serum creatinine measurement and to compare their performance to a gold standard measurement using iohexol measured GFR (mGFR). METHODS: POC creatinine was measured using iSTAT® and StatSensor® devices in capillary and venous whole blood, and laboratory creatinine was measured using the compensated kinetic Jaffe method in 670 participants from a rural area in South Africa. GFR estimating equations Chronic Kidney Disease Epidemiology Collaboration and Modification of Diet in Renal Disease (CKD-EPI and MDRD) for POC and laboratory creatinine were compared to iohexol mGFR. RESULTS: Calculated GFR for laboratory and POC creatinine measurements overestimated GFR (positive bias of 1.9-34.1 mL/min/1.73 m2). However, all POC devices had less positive bias than the laboratory Jaffe method (1.9-14.7 vs. 34.1 for MDRD, and 8.4-19.9 vs. 28.6 for CKD-EPI). Accuracy within 30% of mGFR ranged from 0.56 to 0.72 for POC devices and from 0.36 to 0.43 for the laboratory Jaffe method. POC devices showed wider imprecision with coefficients of variation ranging from 4.6 to 10.2% compared to 3.5% for the laboratory Jaffe method. CONCLUSIONS: POC estimated GFR (eGFR) showed improved performance over laboratory Jaffe eGFR, however POC devices suffered from imprecision and large bias. The laboratory Jaffe method performed poorly, highlighting the need for laboratories to move to enzymatic methods to measure creatinine.


Asunto(s)
Insuficiencia Renal Crónica , Creatinina , Receptores ErbB , Tasa de Filtración Glomerular , Humanos , Yohexol , Sistemas de Atención de Punto , Insuficiencia Renal Crónica/diagnóstico , Sudáfrica
4.
BMC Nephrol ; 22(1): 103, 2021 03 20.
Artículo en Inglés | MEDLINE | ID: mdl-33743616

RESUMEN

BACKGROUND: The prevalence of chronic kidney disease (CKD) is predicted to rise over the next few decades. In resource-limited settings access to central laboratory services is limited. Point-of-care (POC) urine dipstick testing offers the potential to detect markers of kidney damage (albuminuria) as well as markers of other disease processes. We evaluated the diagnostic accuracy of the semi-quantitative albumin-creatinine ratio (ACR) Sysmex UC-1000 POC urine dipstick system as well as the extent of other abnormal dipstick findings in urine. METHODS: 700 participants from a rural area in South Africa were screened for albuminuria. A spot urine sample was used to measure POC and central laboratory ACR. We determined the sensitivity, specificity, positive predictive value and negative predictive value of the POC ACR, and recorded dipstick parameters. RESULTS: The prevalence of albuminuria was 11.6% (95%CI; 9.3-14.2). Those with albuminuria had higher mean diastolic (82 vs 79 mmHg, p = 0.019) and systolic (133 vs 128 mmHg, p = 0.002) blood pressures and a higher proportion of diabetes mellitus (17.6 vs 4.9%, p < 0.001). The sensitivity of the POC ACR system was 0.79, specificity 0.84, positive predictive value 0.39 and negative predictive value 0.97. The sensitivity improved to 0.80, 0.85, 0.85 and 0.89 in those with elevated blood pressure, diabetes mellitus, HIV positive status, and those 65 years and older, respectively. Abnormalities other than albuminuria were detected in 240 (34.3%) of the samples; 88 (12.6%) were positive for haematuria, 113 (16.1%) for leucocytes, 66 (9.4%) for nitrites and 27 (3.9%) for glycosuria. CONCLUSION: Our study shows that POC ACR has good negative predictive value and could be used to rule out albuminuria when screening for CKD. Additionally, a high proportion of participants had other urine abnormalities detected with dipsticks which may reflect kidney disease or co-morbid untreated genitourinary pathology such as urinary tract infections or endemic schistosomiasis with important implications for CKD.


Asunto(s)
Albuminuria/orina , Creatinina/orina , Pruebas en el Punto de Atención , Urinálisis/métodos , Adulto , Femenino , Recursos en Salud , Humanos , Masculino , Persona de Mediana Edad , Atención Primaria de Salud , Estudios Prospectivos , Reproducibilidad de los Resultados , Sudáfrica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...