Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 127
1.
Geosci Front ; 13(6): 101398, 2022 Nov.
Article En | MEDLINE | ID: mdl-37521135

Public transport environments are thought to play a key role in the spread of SARS-CoV-2 worldwide. Indeed, high crowding indexes (i.e. high numbers of people relative to the vehicle size), inadequate clean air supply, and frequent extended exposure durations make transport environments potential hotspots for transmission of respiratory infections. During the COVID-19 pandemic, generic mitigation measures (e.g. physical distancing) have been applied without also considering the airborne transmission route. This is due to the lack of quantified data about airborne contagion risk in transport environments. In this study, we apply a novel combination of close proximity and room-scale risk assessment approaches for people sharing public transport environments to predict their contagion risk due to SARS-CoV-2 respiratory infection. In particular, the individual infection risk of susceptible subjects and the transmissibility of SARS-CoV-2 (expressed through the reproduction number) are evaluated for two types of buses, differing in terms of exposure time and crowding index: urban and long-distance buses. Infection risk and reproduction number are calculated for different scenarios as a function of the ventilation rates (both measured and estimated according to standards), crowding indexes, and travel times. The results show that for urban buses, the close proximity contribution significantly affects the maximum occupancy to maintain a reproductive number of <1. In particular, full occupancy of the bus would be permitted only for an infected subject breathing, whereas for an infected subject speaking, masking would be required. For long-distance buses, full occupancy of the bus can be maintained only if specific mitigation solutions are simultaneously applied. For example, for an infected person speaking for 1 h, appropriate filtration of the recirculated air and simultaneous use of FFP2 masks would permit full occupancy of the bus for a period of almost 8 h. Otherwise, a high percentage of immunized persons (>80%) would be needed.

2.
Eur Rev Med Pharmacol Sci ; 25(17): 5483-5489, 2021 Sep.
Article En | MEDLINE | ID: mdl-34533796

OBJECTIVE: Patients with bipolar disorder (BD) experience a poor quality of life (QoL) and a weak adherence to the therapy due to the various side effects occurring during the pharmacological therapy. To date clinicians have no tools to intervene on such effects, considering them as an unavoidable part of the therapy. This review paves the way for a step forward in the management of patients with BD bridging the therapeutic gap in clinical practice. MATERIALS AND METHODS: We reviewed the literature, searching through different databases (MEDLINE, Scopus, Google Scholar). We used different keywords, including bipolar disorder, lithium and valproic acid, inositol role in bipolar disorder, side effects, inositol depletion, supplementation of inositols under lithium treatment, inositol role in metabolism, hypothyroidism, renal and cardiac functionality. In particular, we narrowed the search down to English literature, excluding works before 1980s. Regarding clinical studies, we included case reports and both preclinical and clinical studies, especially only those exhibiting a control group. The outcome of the database search was to highlight the threat of side effects and the relationship with inositol lower levels, paving the way for a step forward in the management of patients with BD. RESULTS: Based on the collected evidence, the combined administration of myo-inositol (myo-ins) and d-chiro-inositol (d-chiro-ins) is strongly recommended in order to restore levels and metabolism of inositols. Previous studies pointed out the beneficial effects of inositols in recovering pathological conditions, like polycystic ovary syndrome (PCOS), hypothyroidism, weight gain, cardiac functionality, being all these conditions related to the depletion of inositols. Furthermore, a controlled dosage of inositols, up to 6 grams/daily, may reduce the side effects caused by lithium therapy, without hindering its central therapeutic role on patients' mood. CONCLUSIONS: Considering the iatrogenic depletion of inositols, the tailored ratio 80:1 in favour of myo-ins, may become a safe and effective strategy to counteract side effects, by providing a large amount of myo-ins and an adequate one of d-chiro-ins. The clinical dosage of inositols used as dietary supplementation is 4 grams/daily, and it may allow the recovery of the side effects and improve patients' QoL, without reducing the central therapeutic effect of the pharmacological therapy.


Antimanic Agents/administration & dosage , Bipolar Disorder/drug therapy , Inositol/administration & dosage , Antimanic Agents/adverse effects , Bipolar Disorder/physiopathology , Dietary Supplements , Humans , Inositol/metabolism , Lithium Compounds/administration & dosage , Lithium Compounds/adverse effects , Medication Adherence , Quality of Life , Valproic Acid/administration & dosage , Valproic Acid/adverse effects
3.
Eur Rev Med Pharmacol Sci ; 25(6): 2785-2794, 2021 Mar.
Article En | MEDLINE | ID: mdl-33829463

OBJECTIVE: To develop a deep learning-based decision tree for the primary care setting, to stratify adult patients with confirmed and unconfirmed coronavirus disease 2019 (COVID-19), and to predict the need for hospitalization or home monitoring. PATIENTS AND METHODS: We performed a retrospective cohort study on data from patients admitted to a COVID hospital in Rome, Italy, between 5 March 2020 and 5 June 2020. A confirmed case was defined as a patient with a positive nasopharyngeal RT-PCR test result, while an unconfirmed case had negative results on repeated swabs. Patients' medical history and clinical, laboratory and radiological findings were collected, and the dataset was used to train a predictive model for COVID-19 severity. RESULTS: Data of 198 patients were included in the study. Twenty-eight (14.14%) had mild disease, 62 (31.31%) had moderate disease, 64 (32.32%) had severe disease, and 44 (22.22%) had critical disease. The G2 value assessed the contribution of each collected value to decision tree building. On this basis, SpO2 (%) with a cut point at 92 was chosen for the optimal first split. Therefore, the decision tree was built using values maximizing G2 and LogWorth. After the tree was built, the correspondence between inputs and outcomes was validated. CONCLUSIONS: We developed a machine learning-based tool that is easy to understand and apply. It provides good discrimination in stratifying confirmed and unconfirmed COVID-19 patients with different prognoses in every context. Our tool might allow general practitioners visiting patients at home to decide whether the patient needs to be hospitalized.


Algorithms , COVID-19/diagnosis , COVID-19/therapy , Decision Trees , Home Care Services/statistics & numerical data , Hospitalization/statistics & numerical data , Aged , COVID-19/epidemiology , COVID-19/virology , COVID-19 Testing , Cohort Studies , Decision Making, Computer-Assisted , Female , Follow-Up Studies , Humans , Italy/epidemiology , Machine Learning , Male , Monitoring, Physiologic , Prognosis , Retrospective Studies , SARS-CoV-2/isolation & purification
4.
Article En | MEDLINE | ID: mdl-32278291

A fast off-line FPSE-HPLC-PDA method has been reported that allows simultaneous clean up and determination of six non-steroidal anti-inflammatory drugs (NSAIDs) in saliva samples from healthy volunteers. Particularly, furprofen, indoprofen, ketoprofen, fenbufen, flurbiprofen, and ibuprofen were chromatographically resolved. Benzyl paraben was chosen as the internal standard (BzPB, IS). These target compounds were successfully extracted from human saliva using fabric phase sorptive extraction (FPSE) and then analysed in the liquid chromatographic system by means of a short analytical column (Symmetry C18, 75 × 4.6 mm, 3.5 µm) using acetonitrile (AcN) and phosphate buffer (PBS, 30 mM; pH = 2.5) as the mobile phases. The method, validated through the calculation of all analytical parameters in accordance of International Guidelines, was applied to real saliva sample analysis collected from informed volunteers. The proposed approach that included the use of sol-gel polytetrahydrofuran (sol-gel PTHF) sorbent immobilized on cellulose support and C18 stationary phase used in HPLC, showed high potential as a fast tool for future clinical and forensic applications. The herein reported results encourage potential future application of FPSE in the forensic field. Furthermore, the FPSE membrane was tested in dried saliva spot mode (DSS) in order to check its potential use as a sampling device, also for forensic applications.


Anti-Inflammatory Agents, Non-Steroidal/chemistry , Flurbiprofen/chemistry , Phenylpropionates/chemistry , Saliva/chemistry , Anti-Inflammatory Agents, Non-Steroidal/pharmacokinetics , Cellulose/chemistry , Chromatography, High Pressure Liquid , Female , Flurbiprofen/pharmacokinetics , Humans , Limit of Detection , Male , Molecular Structure , Parabens/standards , Phenylpropionates/pharmacokinetics , Solid Phase Microextraction
5.
Article En | MEDLINE | ID: mdl-32172173

The current study reports the development of a novel biofluid sampler (BFS) which is capable of sampling and sample preparation of whole blood without converting it into plasma or serum. The sampler can retain a whole blood sample from 10 to 1000 µL. Although the device shares the same working principle of dried blood spot (DBS) cards, it eliminates most of the technological shortcomings of DBS cards such as low maximum sample volume (~50 µL), sample inhomogeneity due to haematocrit, and poor physical adsorption driven analyte retention by incorporating sol-gel derived high efficiency, multi-functional sorbents on cellulose fabric substrate. The performance of BFS was tested via "Mail-in-Analysis" using three non-steroidal anti-inflammatory drugs (NSAIDs, ketoprofen, carprofen and diclofenac) as the test compounds. Human whole blood samples were fortified with the test compounds and sampled on conventional DBS cards and biofluid samplers (BFSs) in the USA. After drying the blood samples at room temperature, the samples were shipped to Italy for chromatographic analysis. The analytes were back-extracted from the DBS cards and BFSs using methanol and subsequently analysed using a short Symmetry C18 column (75 × 4.6 mm, 3.5 µm). Acetonitrile (ACN) and PBS (30 mM; pH = 2.5) were used as the mobile phases and the elution was performed under isocratic conditions. Compared to the classical dried blood spot cards (DBS), BFSs offer better performance in retaining the selected NSAIDs under conventional postal shipment. By substantially expanding the sampling capacity, eliminating most of the shortcomings of classical DBS cards and exploiting the better materials properties of sol-gel based functional sorbents, BFSs offer a new and profoundly simplified approach for whole blood sampling and analysis and is expected to change the current practice of blood analysis, allowing accurate quantitative analyses either in a local laboratory (on site) or using mail-in-analysis (off site) without compromising the quality of bioanalytical data.


Anti-Inflammatory Agents, Non-Steroidal/analysis , Carbazoles/blood , Diclofenac/blood , Ketoprofen/blood , Plasma/chemistry , Adsorption , Chromatography, High Pressure Liquid , Dried Blood Spot Testing , Hematocrit , Humans , Limit of Detection , Plasma/metabolism , Postal Service , Reproducibility of Results , Specimen Handling , Surface Properties
6.
J Ultrasound ; 21(4): 293-300, 2018 Dec.
Article En | MEDLINE | ID: mdl-30378007

PURPOSE: To assess the diagnostic effectiveness of Multiparametric ultrasound (MPUS), which includes color Doppler ultrasound (CDUS), CEUS and Shear wave elastography (SWE), for evaluating carotid plaque as compared with CT-angiography (CTA) and histology. MATERIALS AND METHODS: Forty-three consecutive patients scheduled to undergo carotid endarterectomy underwent MPUS. Then, after periods ranging from 2 days to 2 weeks, all underwent CTA. Each plaque was classified by means of dedicated scores for CEUS and SWE as compared with CTA features. At surgery, each plaque was removed in a single fragment to facilitate histological analysis, which evaluated 4 features: extension of the lipid core, thickness of the fibrous cap, inflammatory infiltrate (CD68 + and CD3 + markers) and the presence of intraplaque microvessels. For the CEUS, SWE and CTA, the following values for identifying plaque vulnerability were evaluated: sensitivity, specificity, accuracy, negative predictive value (NPV), positive predictive value (PPV) and Area under the curve (AUC). Cohen's kappa was used to evaluate the concordance between measurements in the different imaging methods. A p < 0.05 was considered statistically significant. RESULTS: At histology, 31 out of 43 plaques were identified as vulnerable because of the presence of at least one of the following criteria: fibrous cap < 200 µm, lipid core, intraplaque hemorrhage, inflammatory infiltrate or intraplaque neovascularization. CTA showed a sensitivity of 87.1%, a specificity of 100%, a PPV of 100%, an NPV of 75% and an AUC of 93.5%. SWE showed a sensitivity of 87.1%, a specificity of 66.7%, a PPV of 87.1%, an NPV of 66.7% and an AUC of 76.9%. CEUS showed a sensitivity of 87.1%, a specificity of 58.3%, a PPV of 84.4%, an NPV of 63.6% and an AUC of 72.7%. CONCLUSIONS: Multiparametric ultrasound is an effective modality to obtain comprehensive information on carotid plaques. Further studies are needed to determine whether it can be considered a diagnostic standard.


Carotid Artery Diseases/diagnostic imaging , Elasticity Imaging Techniques , Plaque, Atherosclerotic/diagnostic imaging , Ultrasonography, Doppler, Color , Carotid Artery Diseases/pathology , Carotid Artery Diseases/surgery , Computed Tomography Angiography , Contrast Media , Endarterectomy, Carotid , Humans , Plaque, Atherosclerotic/pathology , Plaque, Atherosclerotic/surgery , Risk , Sensitivity and Specificity , Ultrasonography, Doppler, Color/methods
7.
J Ultrasound ; 19(4): 281-287, 2016 Dec.
Article En | MEDLINE | ID: mdl-27965719

OBJECTIVE: To evaluate the accuracy of contrast-enhanced ultrasound (CEUS) in comparison to CT angiography (CTA) to identify and classify endoleaks following abdominal aortic aneurism repair with endoprosthesis. MATERIALS AND METHODS: A retrospective analysis of 181 patients treated with EVAR, from September 2009 to September 2014, was performed. Patients were evaluated with CEUS, CTA and angiography in the cases requiring treatment. Sac diameter, sac integrity, identification and classification of endoleaks were taken into consideration. Sensitivity, specificity, accuracy and negative predictive values were considered for each modality of endoleak identification. RESULTS: Forty-two endoleaks (23.2%; type II: 39 cases, type III: 3 cases) were documented. Sensitivity and specificity of CEUS and CT were, respectively, 97.6 and 90.5, 100 and 100%. In two cases, CEUS was able to better classify endoleaks compared to CT. CONCLUSIONS: CEUS accuracy to identify endoleaks following EVAR is similar to CT. CEUS should be considered as an effective modality for the long-term surveillance of EVAR because of its capability to correctly classify endoleaks with no ionizing radiation exposure.


Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Computed Tomography Angiography , Contrast Media , Ultrasonography , Aged , Angiography, Digital Subtraction , Blood Vessel Prosthesis Implantation , Female , Follow-Up Studies , Humans , Male , Prosthesis Failure , Sensitivity and Specificity
8.
Eur J Clin Microbiol Infect Dis ; 35(12): 2025-2031, 2016 Dec.
Article En | MEDLINE | ID: mdl-27580910

Serotyping of Streptococcus pneumoniae is essential for monitoring changes in the pneumococcal population and the impact of vaccines. Recently, various DNA-based methods have become available and are increasingly used because they are cheaper and easier to perform than the Quellung reaction. Our aim was to apply a DNA-based method, capsular sequence typing (CST), to a collection of non-viable lyophilized pneumococcal isolates dating from the 1980s to elucidate the serotypes circulating in Italy 30 years ago. As a preliminary evaluation of the method, CST was applied to 68 recent pneumococcal isolates representative of the most common serotypes circulating in Italy in invasive pneumococcal disease (IPD) previously serotyped by the Quellung reaction. CST was then applied to 132 lyophilized non-viable isolates. A serotype-specific polymerase chain reaction (PCR), using primers suggested by the Centers for Disease Control and Prevention (CDC), was performed when CST did not yield a univocal serotype. Considering the control isolates, CST concordance with the Quellung reaction was 95.6 %. For the non-viable lyophilized isolates, CST identified a univocal serotype for 59.4 % of the isolates. This percentage increased to 78.1 % if CST was combined with serotype-specific PCR. The most frequent serotypes in the collection of non-viable strains were: 3 (15.6 %), 14 (11.7 %), 35B (5.5 %), 19A (5.5 %), and 8 (4.7 %). CST proved to be a valid method for serotyping pneumococcal strains and provided information about pneumococcal serotypes present in Italy 30 years ago. The combination of CST with serotype-specific PCR was an effective strategy to identify pneumococcal serotypes that can be suggested also for routine laboratories.


Bacterial Capsules/genetics , Genotyping Techniques/methods , Molecular Typing/methods , Serogroup , Serotyping/methods , Streptococcus pneumoniae/classification , Streptococcus pneumoniae/genetics , DNA, Bacterial/chemistry , DNA, Bacterial/genetics , Humans , Italy
9.
Ultrasound ; 24(2): 104-10, 2016 May.
Article En | MEDLINE | ID: mdl-27482279

High-resolution ultrasound is the first line examination for parotid gland diffuse disease and focal lesions, normally using grey-scale and colour-Doppler ultrasound. Unfortunately, grey-scale and colour-Doppler ultrasound features of benign and malignant salivary gland lesions may overlap, particularly with benign tumors, where pleomorphic adenomas are often indistinguishable from malignant lesions. With atypical lesions, contrast-enhanced magnetic resonance imaging is usually the second level imaging modality requested. The introduction of ultrasound contrast agents has opened further possible perspectives to improve the interpretation of parotid diseases, particularly the differentiation between benign and malignant lesions. We present a review of the current literature on contrast-enhanced ultrasound for the assessment of parotid gland lesions, considering all characteristics of the technique, evidence of usefulness, future perspectives and limitations.

10.
Ultraschall Med ; 37(5): 454-471, 2016 Oct.
Article En | MEDLINE | ID: mdl-27300273

High-resolution ultrasound (US), as a readily available, cost-effective and harmless imaging technique, is appropriately the initial imaging modality for salivary gland lesions. Benign tumors are reported to present with regular and well-defined margins, a homogeneous hypoechoic structure and demarcated vessel distribution, whereas malignant lesions are irregular, heterogeneous and diffusely perfused. Ultrasound and color Doppler features of benign and malignant salivary gland lesions overlap, and many benign tumors, particularly pleomorphic adenomas, may appear irregularly shaped, with a heterogeneous echo-structure indistinguishable from a malignant lesion. Often skilled US operators are not always able to differentiate benign from malignant lesions. The introduction of US contrast agents has allowed further perspectives in the possible improvement of lesion characterization, and the emergence of US elastography, an innovative tool for assessing lesion stiffness/elasticity characteristics, has been advocated for differentiating salivary gland lesions. When lesions are atypical on US, contrast-enhanced magnetic resonance (MR) imaging is usually the definitive imaging modality. We present a current review of benign and malignant parotid gland tumors with emphasis on the role of multiparametric US and MR imaging.


Magnetic Resonance Imaging , Parotid Diseases/diagnostic imaging , Parotid Gland/diagnostic imaging , Parotid Neoplasms/diagnostic imaging , Ultrasonography , Contrast Media , Diagnosis, Differential , Humans , Image Enhancement/methods , Sensitivity and Specificity
12.
J Ultrasound ; 19(1): 25-8, 2016 Mar.
Article En | MEDLINE | ID: mdl-26941879

PURPOSE: Testis sparing surgery (TSS) is a well-known technique in the treatment of small testicular masses. Grayscale ultrasound (US), color/power Doppler US (CPDUS) and contrast-enhanced ultrasound (CEUS) are considered the best diagnostic imaging tools in those patients. Aim of this study was to assess the role of US imaging in the detection of small testicular masses in monorchid patients after orchiectomy for malignant neoplasm, and in guiding surgery to reach the target and also to differentiate lesions which presented vascular activity within the mass. METHODS: From January 2011 to October 2014, 18 patients were enrolled in this study. They had previously undergone orchiectomy and were investigated for suspected contralateral disease. During routine follow-up, all patients underwent grayscale US. If findings were positive, CPDUS and CEUS were performed and eventually all patients underwent surgery. After exteriorization of the testis, the small mass was identified by intraoperative US, and a needle was placed under US guidance. After excision of the mass, frozen section examination was performed. When malignancy was found, radical orchiectomy was performed; if histological outcome was negative, the healthy testis was conserved. RESULTS: All patients underwent grayscale US examination, which showed small hypoechoic masses. Each mass identified at US imaging was confirmed at surgery. All patients underwent CPDUS; 12/19 lesions showed blood flow while 7/19 showed absence of blood flow. At CEUS, 16/19 lesions showed enhancement and subsequent histological examination revealed that 8 were seminomas and 3 were Leydig cell tumors. In 5/19 cases CEUS showed the presence of lesions (focal inflammatory lesions) and in 3/19 cases CEUS was negative. CONCLUSIONS: TSS in monorchid patients may be a safe procedure leading to excellent results. We therefore consider it a valid alternative to radical orchiectomy, and US imaging is essential to guide the resection of non-palpable neoplasms and to exclude concomitant lesions.


Image-Guided Biopsy , Testicular Neoplasms/diagnostic imaging , Ultrasonography, Doppler, Color , Adult , Contrast Media , Gonadal Dysgenesis, 46,XY , Humans , Male , Orchiectomy , Testicular Neoplasms/surgery , Testis/abnormalities
13.
Ultraschall Med ; 37(2): 201-5, 2016 Apr.
Article En | MEDLINE | ID: mdl-25607628

PURPOSE: Ultrasound (US) is the main imaging technique in the assessment of testicular masses, as it has proved to be highly accurate in the visualization of these pathologies. Identification of a Leydig cell tumor is essential since the lesion is benign in 90% of cases. The aim of this multicenter study is to assess the effectiveness of contrast-enhanced ultrasound (CEUS) in differentiating Leydig cell tumors from seminoma using qualitative and quantitative features. MATERIALS AND METHODS: From February 2011 to December 2013, 31 patients (mean age: 34 years; range: 25 - 52) were recruited for this prospective study. Three of them were monorchid. Therefore, a total of 59 testicles were assessed. All patients underwent grayscale US, color Doppler ultrasound (CDUS), CEUS and orchiectomy. The paired one-tailed Student's t-test was carried out to differentiate between Leydig cell tumors and seminomas. RESULTS: 31 lesions suspicious for malignancy were hypoechoic on grayscale US while they did not show a typical pattern on CDUS. CEUS qualitative analysis, based on contrast enhancement pattern, during the arterial and venous phases, did not allow discrimination of Leydig cell tumors from seminoma. Quantitative analysis of time-intensity curves (TICs) demonstrated that only three parameters presented statistical significance, i. e. wash-in rate (WiR) p = 0.014, peak enhancement (PE) p = 0.001 and time to peak (TTP) p = 0.003. CONCLUSION: The vascular bed of a Leydig cell tumor is wider and the blood flow velocity is higher than that of a seminoma due to more regular neovascularization. In contrast, a seminoma presents large areas of necrosis due to irregular neovascularization. This explains the different PE and WiR values. Further studies involving larger patient populations are mandatory to confirm these encouraging preliminary results.


Contrast Media , Image Enhancement , Leydig Cell Tumor/diagnostic imaging , Seminoma/diagnostic imaging , Testicular Neoplasms/diagnostic imaging , Ultrasonography, Doppler, Color , Adult , Blood Flow Velocity , Diagnosis, Differential , Evaluation Studies as Topic , Humans , Leydig Cell Tumor/blood supply , Male , Middle Aged , Seminoma/blood supply , Testicular Neoplasms/blood supply
14.
Eur J Radiol ; 84(9): 1675-84, 2015 Sep.
Article En | MEDLINE | ID: mdl-26014102

Contrast enhanced ultrasonography (CEUS) is increasingly used for non-hepatic applications as well, so that nearly all organs have been investigated. Among them, there is a growing clinical use for a variety of pathologies of the kidney, testis, and small bowel. The possibility to differentiate benign from malignant nodes in cancer patients has been investigated. A new application is in the detection of sentinel nodes after intradermal microbubble injection. The need to distinguish thyroid nodules eligible for fine needle aspiration cytology has led to the use of CEUS in thyroid examinations as well. The potential of CEUS for prostate cancer detection has been extensively investigated, with encouraging initial results. Early promise, however, has not been fulfilled. New perspective regards evaluation of the extent of prostate tissue devascularization following ablative treatments.


Contrast Media , Genital Diseases, Male/diagnostic imaging , Image Enhancement , Intestinal Diseases/diagnostic imaging , Kidney Diseases/diagnostic imaging , Lymphatic Diseases/diagnostic imaging , Thyroid Diseases/diagnostic imaging , Female , Humans , Intestine, Small/diagnostic imaging , Kidney/diagnostic imaging , Lymph Nodes/diagnostic imaging , Male , Prostate/diagnostic imaging , Testis/diagnostic imaging , Thyroid Gland/diagnostic imaging , Ultrasonography
15.
Ultraschall Med ; 36(2): 162-7, 2015 Apr.
Article En | MEDLINE | ID: mdl-24955842

PURPOSE: To assess the best technique and the diagnostic accuracy of Quasistatic Ultrasound Elastography (QUE) in thyroid nodules. Interobserver agreement was also evaluated. MATERIALS AND METHODS: A preliminary study of 50 patients with 54 thyroid nodules was performed with quantitative software in order to define the best cut-off value of different imaging methods. All patients underwent total thyroidectomy and histopathology findings served as the standard of reference. Thereafter, 154 nodules in 137 consecutive patients were prospectively evaluated by three operators. Findings at fine-needle aspiration cytology and histopathology (N = 60) served as the standard of reference. RESULTS: The most accurate technique was the axial peri-intranodular measurement method which achieved an area under the ROC curve of 0.961 (95 %CI 0.848 - 1.00) and had an optimal cut-off value of 3.00. QUE in the differentiation of thyroid nodules showed for operator 1: sensitivity 90 % (95 %CI 73.5 - 97.9 %), specificity 92.7 % (95 %CI 86.7 - 96.6 %), LR+ 12.40 (6.54 - 23.50), LR- 0.11 (0.04 - 0.32) and accuracy 91.4 % (95 %CI 85.4 - 97.3 %); for operator 2: sensitivity 86.7 % (95 %CI 69.3 - 96.2 %), specificity 87.1 % (95 %CI 79.9 - 92.4 %), LR+ 6.72 (4.16 - 10.80), LR- 0.15 (0.06 - 0.38) and accuracy 86.9 % (95 %CI 80.0 - 93.7 %); for operator 3: sensitivity 80 % (95 %CI 61.4 - 92.3 %), specificity 83.9 % (95 %CI 76.2 - 89.9 %), LR+ 4.96 (3.20 - 7.70), LR- 0.24 (0.12 - 0.49) and accuracy 81.9 % (95 %CI 74.0 - 89.9 %). Interobserver agreement values between operator 1 and operator 2 (k = 0.79) (p < 0.05, 95 %CI 0.684 - 0.904), between operator 1 and operator 3 (k = 0.73, 95 %CI: 0.607 - 0.854) and between operator 2 and operator 3 (k = 0.71, 95 %CI: 0.584 - 0.835) were significant. CONCLUSION: QUE provides accurate quantitative evaluation of thyroid nodules with low interobserver variability.


Elasticity Imaging Techniques/methods , Image Interpretation, Computer-Assisted/methods , Software , Thyroid Nodule/diagnostic imaging , Adult , Aged , Biopsy, Fine-Needle , Cohort Studies , Female , Humans , Male , Middle Aged , Observer Variation , ROC Curve , Sensitivity and Specificity , Thyroid Gland/diagnostic imaging , Thyroid Gland/pathology , Thyroid Nodule/pathology , Thyroid Nodule/surgery , Thyroidectomy , Ultrasonography, Interventional
16.
J Ultrasound ; 17(1): 57-63, 2014 Mar.
Article En | MEDLINE | ID: mdl-24616745

PURPOSE: Contrast-enhanced ultrasound (CEUS) is the application of ultrasound contrast agents (UCAs) to traditional medical sonography. The development of UCAs allowed to overcome some of the limitations of conventional B-mode and Doppler ultrasound techniques and enabled the display of the parenchymal microvasculature. Purpose of this paper is to delineate the elements of a solid and science-based technique in the execution of urinary bladder CEUS. METHODS: We describe the technical execution of urinary bladder CEUS and the use of perfusion softwares to perform contrast enhancement quantitative analysis with generation of time-intensity curves from regions of interest. RESULTS: During CEUS, normal bladder wall shows a wash-in time of 13 s, a time to peak (TTP) >40 s, a signal intensity (SI) <45 % and a wash-out time >80 s; Low-grade urothelial cell carcinoma (UCC) shows a wash-in time of 13 s, a time to peak TTP >28 s, a SI <45 % and a wash-out time of 40 s; High-grade UCC shows a wash-in time of 13 s, a TTP >28 s, a SI >50 % and a wash-out time of 58 s. CONCLUSIONS: CEUS is a useful tool for an accurate characterization of bladder UCC although it has some drawbacks. To avoid misunderstandings, a widely accepted classification and a standardized terminology about the most significant parameters of this application should be adopted in the immediate future.

17.
Eur J Radiol ; 83(3): 442-9, 2014 Mar.
Article En | MEDLINE | ID: mdl-24495906

Nowadays ultrasound elastosonography is an established technique, although with limited clinical application, used to assess tissue stiffness, which is a parameter that in most cases is associated with malignancy. However, although a consistent number of articles have been published about several applications of elastosonography, its use in certain human body districts is still not well defined. In this paper we write on the use of elastosonography in prostate, testicle and musculo-skeletal apparatus. We report and compare the work of several authors, different type of elastosonography (shear wave, strain elastography, etc.) and instrumental data obtained in the study of both benign and malignant lesions.

18.
Eur J Radiol ; 82(11): 1892-8, 2013 Nov.
Article En | MEDLINE | ID: mdl-23928231

PURPOSE: To assess the effectiveness of semiquantitative elastosonography (Q-elastography) compared with contrast-enhanced ultrasound (CEUS) in differentiating the nature of thyroid nodules. METHODS AND MATERIALS: Forty-eight consecutive patients (35 males, 13 females, range: 34-69 years, mean: 49.4 years), candidate to surgery, previously detected at color-Doppler ultrasound (CDUS), were prospectively examined with elastosonography with dedicated semiquantitative software (Q-Elastography, Toshiba XG) and CEUS (Technos Mylab 70 Gold X, and Toshiba XG) before surgery. CEUS and elastosonography were evaluated by two investigators in consensus. Comparison between the CEUS pattern and elastonographic strain ratio observed and expected frequencies for the diagnoses was evaluated with χ(2) test or with Fisher exact test. RESULTS: Fifty-three nodules (19 papillary carcinoma, 32 hyperplasia, and 2 follicular adenoma) in 48 patients were available for analysis. Regarding echogenicity score, sensitivity, specificity, PPV and NPV of conventional US were 81%, 50%, 56%, 77%; according to Q-elastography, sensitivity, specificity, PPV and NPV were 95%, 88%, 97% and 91% respectively; whereas concerning CEUS, sensitivity specificity PPV and NPV were 79%, 91%, 83% and 89% respectively. Both CEUS and Q-elastography were more specific than US (p<0.01), with not statistical significant difference with regard to sensitivity. CONCLUSIONS: The results of the present study suggest that Q-elastography is a valuable tool in the characterization of thyroid nodules and it seems to be more sensitive than CEUS.


Elasticity Imaging Techniques/methods , Image Enhancement/methods , Phospholipids , Sulfur Hexafluoride , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/physiopathology , Adult , Aged , Contrast Media , Diagnosis, Differential , Elastic Modulus , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
19.
Eur J Radiol ; 82(11): 1904-12, 2013 Nov.
Article En | MEDLINE | ID: mdl-23816164

Nowadays ultrasound elastosonography is an established technique, although with limited clinical application, used to assess tissue stiffness, which is a parameter that in most cases is associated with malignancy. However, although a consistent number of articles have been published about several applications of elastosonography, its use in certain human body districts is still not well defined. In this paper we write on the use of elastosonography in prostate, testicle and musculo-skeletal apparatus. We report and compare the work of several authors, different type of elastosonography (shear wave, strain elastography, etc.) and instrumental data obtained in the study of both benign and malignant lesions.


Early Detection of Cancer/methods , Elasticity Imaging Techniques/methods , Image Enhancement/methods , Muscular Diseases/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Tendinopathy/diagnostic imaging , Testicular Diseases/diagnostic imaging , Female , Humans , Male
20.
J Ultrasound ; 16(3): 135-8, 2013 Jul 17.
Article En | MEDLINE | ID: mdl-24432165

Differential diagnosis of a mass in the popliteal fossa includes a number of pathologies, such as Baker's cyst, extra-articular ganglia cyst, hematoma, proliferation of adipose tissue, aneurysm of the popliteal artery, thrombosed varicose vein, gouty tophi and benign or malignant soft tissue tumors. Schwannoma is the most common benign peripheral nerve tumor. However, only a few authors have so far reported on schwannomas located on the common fibular nerve. The aim of this paper is to present contrast-enhanced ultrasound and ultrasound elastographic features of a rare case of schwannoma of the common fibular nerve as well as imaging features of a schwannoma of the peripheral nerve.

...