Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Open Heart ; 8(1)2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33712485

RESUMEN

OBJECTIVE: To assess the atrial and ventricular diastolic function response to dobutamine stress in Fontan patients, and to relate these measurements to exercise capacity and events during the follow-up. METHODS: We performed a secondary analysis of a cross-sectional multicentre study of Fontan patients with intra-atrial lateral tunnel (ILT) or extracardiac conduit (ECC) modification. Subjects underwent cardiac MRI during rest and low-dose dobutamine stress, and cardiopulmonary exercise testing. Atrial and diastolic ventricular function parameters were derived from volume-time curves.Medical records were abstracted for a composite end-point of death, listing for transplant, arrhythmia and reintervention. Spearman's r correlation tests and Cox proportional hazards models were used to assess the relation between the dobutamine response for atrial and diastolic ventricular function and outcomes, including exercise capacity. RESULTS: We included 57 patients (26 ECC; 31 ILT) aged 12.8 (IQR (10.3-15.5)) years. During dobutamine stress atrial cyclic volume change increased (3.0 (0.4-5.9) mL/m2, p<0.001), as did early (1.9 (-1.6 to 3.6) mL/m2, p=0.001) and late emptying volume (2.2 (0.2-4.4) mL/m2, p<0.001).Ventricular early filling decreased (-1.6 (-5.7 to 0.7) mL/m2,p=0.046) and ventricular late filling increased (1.0 (-0.4 to 3.4) mL/m2,p<0.001) while stroke volume remained similar.Only for patients with the ECC modification, atrial early emptying volume increase correlated with peak oxygen uptake (ρ=0.66,p=0.002). No other parameter related to exercise capacity.During a median 7.1-year follow-up, 22 patients reached the composite endpoint. No parameter predicted events during the follow-up. CONCLUSIONS: Dobutamine stress augmented atrial reservoir and pump function for Fontan patients. Atrial early emptying reserve related to exercise capacity in ECC patients. No other atrial or diastolic ventricular function parameter related to outcomes.


Asunto(s)
Ecocardiografía de Estrés/métodos , Procedimiento de Fontan/métodos , Atrios Cardíacos/fisiopatología , Cardiopatías Congénitas/cirugía , Ventrículos Cardíacos/fisiopatología , Función Ventricular/fisiología , Adolescente , Adulto , Niño , Estudios Transversales , Femenino , Atrios Cardíacos/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Adulto Joven
2.
J Phys Chem B ; 109(2): 748-56, 2005 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-16866437

RESUMEN

Ribonucleic acid (RNA) homopolymer thin films on highly oriented pyrolytic graphite (HOPG) were prepared in ultrahigh vacuum (UHV) directly from aqueous solution by electrospray (ES) injection. The polyadenosine (poly rA) films were prepared in several steps of increasing thickness without breaking the vacuum. Before deposition and between deposition steps, the samples were characterized with photoemission spectroscopy (PES). Both X-ray and ultraviolet photoemission spectroscopy (XPS and UPS) were employed. XPS enabled the detailed measurement of core level peaks, giving insight into the chemical interaction at the interface and the layer morphology. The corresponding UP-spectra sequence allowed us to directly follow the transition from HOPG valence bands to the poly rA highest occupied molecular orbital (HOMO) structure. This enabled the determination of the poly rA ionization energy and work function as well as the charge injection barriers between the Fermi level of the HOPG substrate and the poly rA HOMO. The injection barrier between the lowest unoccupied molecular orbital (LUMO) and the HOPG Fermi level was determined using the HOMO-LUMO gap value determined by optical absorption. The results indicate that significant injection barriers exist between HOPG and the poly rA overlayer, limiting conductivity across this interface.


Asunto(s)
Adenosina/química , Grafito/química , Polímeros/química , ARN/química , Membranas Artificiales , Tamaño de la Partícula , Sensibilidad y Especificidad , Espectrofotometría/métodos , Propiedades de Superficie , Vacio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...