Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 8 de 8
1.
Diagnostics (Basel) ; 14(6)2024 Mar 14.
Article En | MEDLINE | ID: mdl-38535037

(1) Background: Accurate hepatic artery (HA) depiction following pediatric liver transplantation (LT) is essential for graft surveillance but challenging on ultrasound (US). This study assesses if improved HA delineation can be achieved by recording two-dimensional US volumes in Color Doppler (CD) and B-flow technique. (2) Methods: Of 42 consecutive LT, 37 cases were included, and HA delineation was retrospectively rated using a four-point score (0 = HA not detectable, 3 = HA fully detectable, separable from portal vein) within 48 h post-LT (U1) and before discharge (U2). (3) Results: Adding B-flow compared with CD alone showed superior results at neohilar (U1: 2.2 ± 1.0 vs. 1.1 ± 0.8, p < 0.0001; U2: 2.5 ± 0.8 vs. 1.5 ± 0.9, p < 0.0001) and segmental levels (U1: 2.8 ± 0.6 vs. 0.6 ± 0.8, p < 0.0001; U2: 2.8 ± 0.6 vs. 0.7 ± 0.5, p < 0.0001). (4) Conclusions: Standardized US volume recordings combining B-flow and CD can effectively delineate the HA along its vascular course in pediatric LT. The technique should be further evaluated as a standard monitoring instrument to rule out vascular complications after LT.

3.
Pediatr Radiol ; 54(2): 269-275, 2024 02.
Article En | MEDLINE | ID: mdl-38216682

BACKGROUND: Liver transplantation is the state-of-the-art curative treatment for end-stage liver disease. Imaging is a key element in the detection of intraoperative and postoperative complications. So far, only limited data regarding the best radiological approach to monitor children during liver transplantation is available. OBJECTIVE: To harmonize the imaging of pediatric liver transplantation, the European Society of Pediatric Radiology Abdominal Taskforce initiated a survey addressing the current status of imaging including the pre-, intra- and postoperative phase. This paper reports the responses related to intraoperative imaging. MATERIALS AND METHODS: An online survey, initiated in 2021, asked European centers performing pediatric liver transplantation 48 questions about their imaging approach. In total, 26 centers were contacted, and 22 institutions from 11 countries returned the survey. RESULTS: Intraoperative ultrasound (US) is used by all sites to assess the quality of the vascular anastomosis in order to ensure optimal perfusion of the liver transplant. Vessel depiction is commonly achieved using color Doppler (95.3%). Additional US-based techniques are employed by fewer centers (power angio mode, 28.6%; B-flow, 19%; contrast-enhanced US, 14.3%). Most centers prefer a collaborative approach, with surgeons responsible for probe handling, while radiologists operate the US machine (47.6%). Less commonly, the intraoperative US is performed by the surgeon alone (28.6%) or by the radiologist alone (23.8%). Timing of US, imaging frequency, and documentation practices vary among centers. CONCLUSION: Intraoperative US is consistently utilized across all sites during pediatric liver transplantation. However, considerable variations were observed in terms of the US setup, technique preferences, timing of controls, and documentation practices. These differences provide valuable insights for future optimization and harmonization studies.


Liver Transplantation , Radiology , Child , Humans , Ultrasonography , Radiography , Postoperative Complications/diagnostic imaging
4.
Pediatr Radiol ; 54(2): 276-284, 2024 02.
Article En | MEDLINE | ID: mdl-38285190

BACKGROUND: Liver transplantation is the state-of-the-art curative treatment for end-stage liver disease. Imaging is a key element in the detection of postoperative complications. So far, limited data is available regarding the best radiologic approach to monitor children after liver transplantation. OBJECTIVE: To harmonize the imaging of pediatric liver transplantation, the European Society of Pediatric Radiology Abdominal Taskforce initiated a survey addressing the current status of imaging including the pre-, intra-, and postoperative phases. This paper reports the responses related to postoperative imaging. MATERIALS AND METHODS: An online survey, initiated in 2021, asked European centers performing pediatric liver transplantation 48 questions about their imaging approach. In total, 26 centers were contacted, and 22 institutions from 11 countries returned the survey. RESULTS: All sites commence ultrasound (US) monitoring within 24 h after liver transplantation. Monitoring frequency varies across sites, ranging from every 8 h to 72 h in early, and from daily to sporadic use in late postoperative phases. Predefined US protocols are used by 73% of sites. This commonly includes gray scale, color Doppler, and quantitative flow assessment. Alternative flow imaging techniques, contrast-enhanced US, and elastography are applied at 31.8%, 18.2%, and 63.6% of sites, respectively. Computed tomography is performed at 86.4% of sites when clarification is needed. Magnetic resonance imaging is used for selected cases at 36.4% of sites, mainly for assessment of biliary abnormalities or when blood tests are abnormal. CONCLUSION: Diagnostic imaging is extensively used for postoperative surveillance of children after liver transplantation. While US is generally prioritized, substantial differences were noted in US protocol, timing, and monitoring frequency. The study highlights potential areas for future optimization and standardization of imaging, essential for conducting multicenter studies.


Liver Transplantation , Radiology , Child , Humans , Ultrasonography , Magnetic Resonance Imaging/methods , Ultrasonography, Doppler , Postoperative Complications/diagnostic imaging
5.
Pediatr Radiol ; 54(2): 260-268, 2024 02.
Article En | MEDLINE | ID: mdl-37985493

BACKGROUND: Liver transplantation is the state-of-the-art curative treatment in end-stage liver disease. Imaging is a key element for successful organ-transplantation to assist surgical planning. So far, only limited data regarding the best radiological approach to prepare children for liver transplantation is available. OBJECTIVES: In an attempt to harmonize imaging surrounding pediatric liver transplantation, the European Society of Pediatric Radiology (ESPR) Abdominal Taskforce initiated a survey addressing the current status of imaging including the pre-, intra-, and postoperative phase. This paper reports the responses on preoperative imaging. MATERIAL AND METHODS: An online survey, initiated in 2021, asked European centers performing pediatric liver transplantation 48 questions about their imaging approach. In total, 26 centers were contacted and 22 institutions from 11 countries returned the survey. From 2018 to 2020, the participating centers collectively conducted 1,524 transplantations, with a median of 20 transplantations per center per annum (range, 8-60). RESULTS: Most sites (64%) consider ultrasound their preferred modality to define anatomy and to plan surgery in children before liver transplantation, and additional cross-sectional imaging is only used to answer specific questions (computed tomography [CT], 90.9%; magnetic resonance imaging [MRI], 54.5%). One-third of centers (31.8%) rely primarily on CT for pre-transplant evaluation. Imaging protocols differed substantially regarding applied CT scan ranges, number of contrast phases (range 1-4 phases), and applied MRI techniques. CONCLUSION: Diagnostic imaging is generally used in the work-up of children before liver transplantation. Substantial differences were noted regarding choice of modalities and protocols. We have identified starting points for future optimization and harmonization of the imaging approach to multicenter studies.


Liver Transplantation , Radiology , Child , Humans , Ultrasonography , Tomography, X-Ray Computed , Magnetic Resonance Imaging/methods
7.
Rofo ; 193(1): 49-60, 2021 Jan.
Article En | MEDLINE | ID: mdl-32516824

OBJECTIVE: To compare B-flow sonography (BFS) with color Doppler sonography (CDS) for imaging of kidney transplant vascularization in children. PATIENTS AND METHODS: All children receiving a kidney transplantation who underwent a protocol-based ultrasound examination (Loqiq 9, GE Medical Systems, Milwaukee, WI, USA) using the BFS and CDS technique with equal settings and probe position between January 2013 and January 2016 were retrospectively assessed (n = 40). The obtained datasets were visually graded according to the following criteria: (I) delineation of the renal vascular tree (Grade 1 - clear demarcation of interlobar, together with arcuate and interlobular vessels; Grade 2 - clear demarcation of interlobar and cortical vessels, but no distinction of interlobular from arcuate vessels; Grade 3 - only clear demarcation of interlobar vessels, Grade 4 - insufficient demarcation) (II) delineation of cortical vessel density in ventral, lateral, and dorsal part of the transplant, (III) smallest vessel-capsule distance, and (IV) maximum cortical vessel count. Comparison between methods was performed using Fisher's exact and paired sample t-tests. RESULTS: Applying a curved transducer (C1-6), BFS showed superior delineation of the renal vascular tree (p < 0.001), a lower vessel-capsule distance (p < 0.001), a higher cortical vessel count (p < 0.001), and a higher cortical vessel density in the superficial cortex (p = 0.01) than CDS. In the dorsal and lateral aspects of the transplant, cortical vessel density was lower with BFS (both p < 0.001). Using a linear high-resolution transducer (ML 6-15), no significant differences between the methods were found. CONCLUSION: Improved imaging of kidney transplant vascularization can be achieved in children by adding BFS to a standard protocol. The BFS technique is especially beneficial for overall assessment of the renal vascular tree together with the extent of cortical vascularization on curved array images. KEY POINTS: · Depiction of vascular tree and ventral cortical vessels is improved by BFS.. · The dorso-lateral cortex was better represented with CDS because of higher penetration.. · Additional monitoring with BFS improves the monitoring of transplant viability.. CITATION FORMAT: · Dammann E, Groth M, Schild R et al. B-Flow Sonography vs. Color Doppler Sonography for the Assessment of Vascularity in Pediatric Kidney Transplantation. Fortschr Röntgenstr 2021; 193: 49 - 60.


Kidney Transplantation , Kidney/blood supply , Kidney/diagnostic imaging , Ultrasonography/methods , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Male , Ultrasonography, Doppler, Color
8.
Rofo ; 189(12): 1161-1167, 2017 Dec.
Article En | MEDLINE | ID: mdl-28683505

Purpose To evaluate femoral arteries (FAs) in infants in the context of catheter angiography with B-mode (BMS) and B-flow sonography (BFS) and to compare both methods for vessel delineation and reliability of vessel diameter measurements. Methods 21 consecutive infants who underwent ultrasound for the evaluation of FAs before or after cardiac catheterization were retrospectively included in this study. The diameter of the FAs and the maximum length of the vessel section displayed on a single ultrasound plane were recorded by two radiologists for BMS and BFS. The visual image quality was rated by one observer. Statistics included intraclass correlation coefficient, Bland-Altman analysis, Fisher´s exact test and t-test. Results The intraobserver as well as interobserver correlation was excellent for BMS (0.7922 and 0.6521) and BFS (0.8094 and 0.7637). The Bland-Altman analysis revealed limits of agreement for BMS between +/-0.73 mm (intraobserver) and +/-0.55 mm (interobserver) and for BFS between +/-0.83 mm (intraobserver) and +/-0.7 mm (interobserver). BFS allowed visualization of a longer stretch of the FA than BMS (length 3.54 +/-0.85 vs. 2.21 +/-0.9 cm, p < 0.0001). The image quality was significantly higher for BFS (p = 0.0043). Conclusion Since BFS shows excellent reproducibility for vessel measurements and superior image quality in infants, if available, BFS should be included in standard protocols when realistic measurements are required. Key Points · B-flow sonography offers high image quality for the evaluation of femoral arteries.. · Femoral artery diameter measurements performed with B-flow sonography show excellent reproducibility.. · If available, additional B-flow sonography of femoral arteries in infants is recommended.. Citation Format · Groth M, Dammann E, Arndt F et al. Comparison of B-Mode with B-Flow Sonography for the Evaluation of Femoral Arteries in Infants. Fortschr Röntgenstr 2017; 189: 1161 - 1167.


Blood Flow Velocity/physiology , Femoral Artery/diagnostic imaging , Femoral Artery/physiology , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Multimodal Imaging/methods , Female , Femoral Artery/anatomy & histology , Humans , Infant , Infant, Newborn , Male , Observer Variation , Reproducibility of Results , Sensitivity and Specificity
...