1.
Ultrasonics ; 54(7): 1938-44, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24856899

RESUMEN

The feasibility of using subharmonic aided pressure estimation (SHAPE) to noninvasively estimate interstitial fluid pressure (IFP) was studied. In vitro, radiofrequency signals, from 0.2 ml/l of Definity (Lantheus Medical Imaging, N Billerica, MA) were acquired within a water-tank with a Sonix RP ultrasound scanner (Analogic Ultrasound, Richmond, BC, Canada; fT/R=6.7/3.35 MHz and fT/R=10/5 MHz) and the subharmonic amplitudes of the signals were compared over 0-50 mmHg. In vivo, five swine with naturally occurring melanomas were studied. Subharmonic signals were acquired from tumours and surrounding tissue during infusion of Definity and compared to needle-based pressure measurements. Both in vitro and in vivo, an inverse linear relationship between hydrostatic pressure and subharmonic amplitude was observed with r(2)=0.63-0.95; p<0.05, maximum amplitude drop 11.36 dB at 10 MHz and -8 dB, and r(2) as high as 0.97; p<0.02 (10 MHz and -4/-8 dB most promising), respectively, indicating that SHAPE may be useful in monitoring IFP.


Asunto(s)
Líquido Extracelular/diagnóstico por imagen , Melanoma/diagnóstico por imagen , Acústica , Animales , Medios de Contraste/administración & dosificación , Diseño de Equipo , Estudios de Factibilidad , Fluorocarburos/administración & dosificación , Presión Hidrostática , Fantasmas de Imagen , Porcinos , Transductores , Ultrasonografía/métodos
2.
Ultrasonics ; 53(4): 880-8, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23347593

RESUMEN

Incident acoustic output (IAO) dependent subharmonic signal amplitudes from ultrasound contrast agents can be categorized into occurrence, growth or saturation stages. Subharmonic aided pressure estimation (SHAPE) is a technique that utilizes growth stage subharmonic signal amplitudes for hydrostatic pressure estimation. In this study, we developed an automated IAO optimization algorithm to identify the IAO level eliciting growth stage subharmonic signals and also studied the effect of pulse length on SHAPE. This approach may help eliminate the problems of acquiring and analyzing the data offline at all IAO levels as was done in previous studies and thus, pave the way for real-time clinical pressure monitoring applications. The IAO optimization algorithm was implemented on a Logiq 9 (GE Healthcare, Milwaukee, WI) scanner interfaced with a computer. The optimization algorithm stepped the ultrasound scanner from 0% to 100% IAO. A logistic equation fitting function was applied with the criterion of minimum least squared error between the fitted subharmonic amplitudes and the measured subharmonic amplitudes as a function of the IAO levels and the optimum IAO level was chosen corresponding to the inflection point calculated from the fitted data. The efficacy of the optimum IAO level was investigated for in vivo SHAPE to monitor portal vein (PV) pressures in 5 canines and was compared with the performance of IAO levels, below and above the optimum IAO level, for 4, 8 and 16 transmit cycles. The canines received a continuous infusion of Sonazoid microbubbles (1.5 µl/kg/min; GE Healthcare, Oslo, Norway). PV pressures were obtained using a surgically introduced pressure catheter (Millar Instruments, Inc., Houston, TX) and were recorded before and after increasing PV pressures. The experiments showed that optimum IAO levels for SHAPE in the canines ranged from 6% to 40%. The best correlation between changes in PV pressures and in subharmonic amplitudes (r=-0.76; p=0.24), and between the absolute PV pressures and the subharmonic amplitudes (r=-0.89; p<0.01) were obtained for the optimized IAO and 4 transmit cycles. Only for the optimized IAO and 4 transmit cycles did the subharmonic amplitudes differ significantly (p<0.01) before and after increasing PV pressures. A new algorithm to identify optimum IAO levels for SHAPE has been developed and validated with the best results being obtained for 4 transmit cycles. The work presented in this study may pave the way for real-time clinical applications of estimating pressures using the subharmonic signals from ultrasound contrast agents.


Asunto(s)
Algoritmos , Determinación de la Presión Sanguínea/métodos , Medios de Contraste/química , Compuestos Férricos/química , Hierro/química , Óxidos/química , Presión Portal/fisiología , Vena Porta/diagnóstico por imagen , Ultrasonografía/métodos , Acústica , Animales , Perros , Aumento de la Imagen/métodos
3.
Ultrasonics ; 51(8): 890-7, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21621239

RESUMEN

OBJECTIVE: To demonstrate the feasibility of simultaneous dual fundamental grayscale and subharmonic imaging on a modified commercial scanner. MOTIVATION: The ability to generate signals at half the insonation frequency is exclusive to ultrasound contrast agents (UCA). Thus, subharmonic imaging (SHI; transmitting at f(0) and receiving at f(0)/2) provides improved visualization of UCA within the vasculature via suppression of the surrounding tissue echoes. While this capability has proven useful in a variety of clinical applications, the SHI suppression of surrounding tissue landmarks (which are needed for sonographic navigation) also limits it use as a primary imaging modality. In this paper we present results using a commercial ultrasound scanner modified to allow imaging in both grayscale (f(0)=4.0 MHz) and SHI (f(0)=2.5 MHz, f(0)/2=1.25 MHz) modes in real time. METHODS: A Logiq 9 ultrasound scanner (GE Healthcare, Milwaukee, WI) with a 4C curvilinear probe was modified to provide this capability. Four commercially available UCA (Definity, Lantheus Medical Imaging, North Billerica, MA; Optison, GE Healthcare, Princeton, NJ; SonoVue, Bracco Imaging, Milan, Italy; and Sonazoid, GE Healthcare, Oslo, Norway) were all investigated in vitro over an acoustic output range of 3.34 MPa. In vivo the subharmonic response of Sonazoid was investigated in the portal veins of four canines (open abdominal cavity) and four patients with suspected portal hypertension. RESULTS: In vitro, the four UCA showed an average maximum subharmonic amplitude of 44.1±5.4 dB above the noise floor with a maximum subharmonic amplitude of 48.6±1.6 dB provided by Sonazoid. The average in vivo maximum signal above the noise floor from Sonazoid was 20.8±2.3 dB in canines and 33.9±5.2 dB in humans. Subharmonic amplitude as a function of acoustic output in both groups matched the S-curve behavior of the agent observed in vitro. The dual grayscale imaging provided easier sonographic navigation, while the degree of tissue suppression in SHI mode varied greatly on a case by case basis. CONCLUSIONS: These results demonstrate the feasibility of dual grayscale and SHI on a modified commercial scanner. The ability to simultaneously visualize both imaging modes in real time should improve the applicability of SHI as a future primary clinical imaging modality.


Asunto(s)
Medios de Contraste/farmacocinética , Hipertensión Portal/diagnóstico por imagen , Ultrasonografía/instrumentación , Albúminas/farmacocinética , Análisis de Varianza , Animales , Perros , Estudios de Factibilidad , Compuestos Férricos/farmacocinética , Fluorocarburos/farmacocinética , Humanos , Hierro/farmacocinética , Óxidos/farmacocinética , Fosfolípidos/farmacocinética , Proyectos Piloto , Hexafluoruro de Azufre/farmacocinética
4.
Vox Sang ; 31(1): 70-3, 1976.
Artículo en Inglés | MEDLINE | ID: mdl-936567

RESUMEN

A laboratory method for the indirect detection of hepatitis-B antigen (HB8Ag) based on the presence of 'anomalous' LDH isoenzyme by disc electrophoresis has been developed. The method is specific and highly sensitive when compared with existing methods.


Asunto(s)
Antígenos de la Hepatitis B/análisis , L-Lactato Deshidrogenasa , Electroforesis Discontinua , Humanos , Isoenzimas