Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 16 de 16
1.
Opt Express ; 32(12): 20459-20470, 2024 Jun 03.
Article En | MEDLINE | ID: mdl-38859427

When a hollow core fiber is drawn, the core and cladding holes within the internal cane geometry are pressurized with an inert gas to enable precise control over the internal microstructure of the fiber and counteract surface tension forces. Primarily by considering the temperature drop as the fiber passes through the furnace and the geometrical transformation of the internal microstructure from preform-to-fiber, we recently established that the gas pressure within the final 'as-drawn' fiber is substantially below atmospheric pressure. We have also established that slight changes in the gas refractive index within the core and surrounding cladding holes induced by changes in gas pressure are sufficient to significantly affect both the modality and loss of the fiber. Here we demonstrate, through both simulations and experimental measurements, that the combination of these effects leads to transient changes in the fiber's attenuation when the fibers are opened to atmosphere post-fabrication. It is important to account for this phenomenon for accurate fiber characterization, particularly when long lengths of fiber are drawn where it could take many weeks for every part of the internal microstructure to reach atmospheric pressure.

2.
Sensors (Basel) ; 24(8)2024 Apr 12.
Article En | MEDLINE | ID: mdl-38676099

Label-free and multiphoton micro-endoscopy can transform clinical histopathology by providing an in situ tool for diagnostic imaging and surgical treatment in diseases such as cancer. Key to a multiphoton imaging-based micro-endoscopic device is the optical fiber, for distortion-free and efficient delivery of ultra-short laser pulses to the sample and effective signal collection. In this work, we study a new hollow-core (air-filled) double-clad anti-resonant fiber (DC-ARF) as a high-performance candidate for multiphoton micro-endoscopy. We compare the fiber characteristics of the DC-ARF with a single-clad anti-resonant fiber (SC-ARF) and a solid core fiber (SCF). In this work, while the DC-ARF and the SC-ARF enable low-loss (<0.2 dBm-1), close to dispersion-free excitation pulse delivery (<10% pulse width increase at 900 nm per 1 m fiber) without any induced non-linearities, the SCF resulted in spectral broadening and pulse-stretching (>2000% of pulse width increase at 900 nm per 1 m fiber). An ideal optical fiber endoscope needs to be several meters long and should enable both excitation and collection through the fiber. Therefore, we performed multiphoton imaging on endoscopy-compatible 1 m and 3 m lengths of fiber in the back-scattered geometry, wherein the signals were collected either directly (non-descanned detection) or through the fiber (descanned detection). Second harmonic images were collected from barium titanate crystals as well as from biological samples (mouse tail tendon). In non-descanned detection conditions, the ARFs outperformed the SCF by up to 10 times in terms of signal-to-noise ratio of images. Significantly, only the DC-ARF, due to its high numerical aperture (NA) of 0.45 and wide-collection bandwidth (>1 µm), could provide images in the de-scanned detection configuration desirable for endoscopy. Thus, our systematic characterization and comparison of different optical fibers under different image collection configurations, confirms and establishes the utility of DC-ARFs for high-performing label-free multiphoton imaging-based micro-endoscopy.

3.
Opt Express ; 32(5): 7720-7730, 2024 Feb 26.
Article En | MEDLINE | ID: mdl-38439447

Hollow-core optical fibers can offer broadband, single mode guidance in the UV-visible-NIR wavelength range, with the potential for low-loss, solarization-free operation, making them desirable and potentially disruptive for a wide range of applications. To achieve this requires the fabrication of fibers with <300nm anti-resonant membranes, which is technically challenging. Here we investigate the underlying fluid dynamics of the fiber fabrication process and demonstrate a new three-stage fabrication approach, capable of delivering long (∼350m) lengths of fiber with the desired thin-membranes.

4.
Opt Express ; 31(25): 41191-41201, 2023 Dec 04.
Article En | MEDLINE | ID: mdl-38087524

We demonstrate a multi-watt, picosecond pulse duration laser source by exploiting a cascaded Raman process to the second Stokes signal at a wavelength of 2.58 µm in a methane-filled Nested Anti-Resonant Nodeless fiber from a 1 µm disk laser source. A maximum average power of 2.89 W (14.45 µJ) is produced in a 160 cm length of custom-designed and in-house fabricated fiber filled with methane at a pressure of 2 bar. The impact of gas pressure and propagation distance on the second Stokes signal power are investigated experimentally. The experimental results are simulated by solving the Generalized Nonlinear Schrodinger Equation with the experiment carefully modelled by accounting for the impacts of pressure dependent gas-light interactions along the pressure gradient of the fiber. This work offers a laser source for a variety of applications as well as expanding the modelling space to methane filled fibers including pressure gradients, and nonlinear optical activity in the presence of infrared gas absorption.

5.
Opt Express ; 31(21): 34064-34073, 2023 Oct 09.
Article En | MEDLINE | ID: mdl-37859171

By exploiting the excellent short-term phase stability between consecutive pulses from a free-running optical parametric oscillator frequency comb, we report the first example of hollow-core fiber-delivered heterodyne spectroscopy in the 3.1-3.8 µm wavelength range. The technique provides a means of spectroscopically interrogating a sample situated at the distal end of a fiber, with all electronics and light sources situated at the proximal end and with an inherent capability to suppress spectroscopically interfering features present in the free-space and in-fiber delivery path. Using a silica anti-resonant, hollow-core delivery fiber, we demonstrate high quality transmission and attenuated total reflectance spectroscopy of a plastic sample for fiber lengths of up to 40 m, significantly exceeding the few-meter lengths typically possible using solid-core fibers. The technique opens a route to implementing multi-species spectroscopic monitoring in remote and / or hostile industrial environments and medical applications.

6.
Opt Express ; 31(19): 30227-30238, 2023 Sep 11.
Article En | MEDLINE | ID: mdl-37710569

We report the flexible on-target delivery of 800 nm wavelength, 5 GW peak power, 40 fs duration laser pulses through an evacuated and tightly coiled 10 m long hollow-core nested anti-resonant fiber by positively chirping the input pulses to compensate for the anomalous dispersion of the fiber. Near-transform-limited output pulses with high beam quality and a guided peak intensity of 3 PW/cm2 were achieved by suppressing plasma effects in the residual gas by pre-pumping the fiber with laser pulses after evacuation. This appears to cause a long-term removal of molecules from the fiber core. Identifying the fluence at the fiber core-wall interface as the damage origin, we scaled the coupled energy to 2.1 mJ using a short piece of larger-core fiber to obtain 20 GW at the fiber output. This scheme can pave the way towards the integration of anti-resonant fibers in mJ-level nonlinear optical experiments and laser-source development.

7.
Opt Express ; 30(24): 43317-43329, 2022 Nov 21.
Article En | MEDLINE | ID: mdl-36523032

We demonstrate recent progress in the development of a Raman gas sensor using a single cladding ring anti-resonant hollow core micro-structured optical fiber (HC-ARF) and a low power pump source. The HC-ARF was designed specifically for low attenuation and wide bandwidth in the visible spectral region and provided low loss at both the pump wavelength (532 nm) and Stokes wavelengths up to a Raman shift of 5000 cm-1. A novel selective core pressurization scheme was also implemented to further reduce the confinement loss, improving the Raman signal enhancement by a factor of 1.9 compared to a standard fiber filling scheme. By exploiting longer lengths of fiber, direct detection of both methane and hydrogen at concentrations of 5 and 10 ppm respectively is demonstrated and a noise equivalent limit-of-detection of 0.15 ppm is calculated for methane.

8.
Opt Lett ; 47(20): 5301-5304, 2022 Oct 15.
Article En | MEDLINE | ID: mdl-36240347

We report a high-power single-mode mid-infrared (MIR) pulse delivery system via anti-resonant hollow-core fiber (HCF) with a record delivery distance of 108 m. Near-diffraction-limited MIR light was transmitted by HCFs at wavelengths of 3.12-3.58 µm using a tunable optical parametric oscillator (OPO) as the light source. The HCFs were purged beforehand with argon in order to remove or reduce loss due to parasitic gas absorption (HCl, CO2, etc.). The minimum fiber loss values were 0.05 and 0.24 dB/m at 3.4-3.6 µm and 4.5-4.6 µm, respectively, with the 4.5-4.6 µm loss figure representing, to the best of our knowledge, a new low loss record for a HCF in this spectral region. At a coupling efficiency of ∼70%, average powers of 592 mW and 133 mW were delivered through 5 m and 108 m of HCF, respectively. Assuming the 120-ps duration of the MIR pulses remained constant over the low-dispersion HCF (theoretical maximum: 0.4 ps/nm/km), the corresponding calculated peak powers were 4.9 kW and 1.1 kW.

10.
Opt Express ; 30(5): 7044-7052, 2022 Feb 28.
Article En | MEDLINE | ID: mdl-35299476

High-resolution multi-species spectroscopy is achieved by delivering broadband 3-4-µm mid-infrared light through a 4.5-meter-long silica-based hollow-core optical fiber. Absorptions from H37Cl, H35Cl, H2O and CH4 present in the gas within the fiber core are observed, and the corresponding gas concentrations are obtained to 5-ppb precision using a high-resolution Fourier-transform spectrometer and a full-spectrum multi-species fitting algorithm. We show that by fully fitting the narrow absorption features of these light molecules their contributions can be nulled, enabling further spectroscopy of C3H6O and C3H8O contained in a Herriott cell after the fiber. As a demonstration of the potential to extend fiber-delivered broadband mid-infrared spectroscopy to significant distances, we present a high-resolution characterization of the transmission of a 63-meter length of hollow-core fiber, fully fitting the input and output spectra to obtain the intra-fiber gas concentrations. We show that, despite the fiber not having been purged, useful spectroscopic windows are still preserved which have the potential to enable hydrocarbon spectroscopy at the distal end of fibers with lengths of tens or even hundreds of meters.

11.
Appl Opt ; 61(30): 8959-8966, 2022 Oct 20.
Article En | MEDLINE | ID: mdl-36607023

One of the major challenges in the deployment of quantum communications (QC) over solid-core silica optical fiber is the performance degradation due to the optical noise generated with co-propagating classical optical signals. To reduce the impact of the optical noise, research teams are turning to new and novel architectures of solid-core and hollow-core optical fiber. We studied the impact when co-propagating a single-photon level (850 nm) and two classical optical signals (940 nm and 1550 nm) while utilizing a nested antiresonant nodeless fiber (NANF) with two low-loss windows. The 940 nm signal was shown to impact the single-photon measurement due to the silicon detector technology implemented; however, multiplexing techniques and filtering could reduce the impact. The 1550 nm signal was shown to have no detrimental impact. The results highlight that both high bandwidth optical traffic at 1550 nm and a QC channel at 850 nm could co-propagate without degradation to the QC channel.

12.
Br J Hosp Med (Lond) ; 82(12): 1-11, 2021 Dec 02.
Article En | MEDLINE | ID: mdl-34983215

The accompanying article set out why it is important to identify autistic people and the negative consequences of not recognising or understanding autism, including more severe illness and premature death. This article sets out what clinicians can do to help reduce those negative consequences by making 'reasonable adjustments' in any healthcare service in which they work.


Autistic Disorder , Autistic Disorder/epidemiology , Autistic Disorder/therapy , Delivery of Health Care , Humans
13.
Br J Hosp Med (Lond) ; 82(12): 1-7, 2021 Dec 02.
Article En | MEDLINE | ID: mdl-34983217

Recognition of autism and the associated co-occurring physical and mental health issues has increased over recent years. However, undergraduate and postgraduate curricula take time to adapt and to impact on what is delivered in training so healthcare professionals, including doctors, report little training on these topics. Doctors need to know when someone might be autistic in order to respond to them appropriately. This article sets out the reasons why recognition of autism is important and the positive impacts of recognising and understanding autism on health outcomes, service delivery and patient experience. The negative consequences of not recognising autism or understanding the impact of autistic traits on the person are also explored. A companion article then covers how practice can be made more appropriate for autistic people to improve outcomes.


Autistic Disorder , Autistic Disorder/diagnosis , Autistic Disorder/epidemiology , Autistic Disorder/therapy , Delivery of Health Care , Health Personnel , Humans
14.
Nat Commun ; 11(1): 6030, 2020 Nov 27.
Article En | MEDLINE | ID: mdl-33247139

For over 50 years, pure or doped silica glass optical fibres have been an unrivalled platform for the transmission of laser light and optical data at wavelengths from the visible to the near infra-red. Rayleigh scattering, arising from frozen-in density fluctuations in the glass, fundamentally limits the minimum attenuation of these fibres and hence restricts their application, especially at shorter wavelengths. Guiding light in hollow (air) core fibres offers a potential way to overcome this insurmountable attenuation limit set by the glass's scattering, but requires reduction of all the other loss-inducing mechanisms. Here we report hollow core fibres, of nested antiresonant design, with losses comparable or lower than achievable in solid glass fibres around technologically relevant wavelengths of 660, 850, and 1060 nm. Their lower than Rayleigh scattering loss in an air-guiding structure offers the potential for advances in quantum communications, data transmission, and laser power delivery.

15.
Opt Express ; 28(2): 1518-1525, 2020 Jan 20.
Article En | MEDLINE | ID: mdl-32121860

Using micro-optic collimator technology, we present compact, low-loss optical interconnection devices for hollow core fibers (HCFs). This approach is one of the key manufacturing platforms for commercially available fiber optic components and most forms of HCFs can readily be incorporated into this platform without the need for any substantial or complicated adaptation or physical deformation of the fiber structure. Furthermore, this technique can provide for very low Fresnel reflection interconnection between solid-core fiber and HCF and in addition provides a hermetic seal for HCFs, which can be a critical issue for many HCF applications. In this paper, several exemplar HCF components are fabricated with low insertion loss (0.5-2 dB), low Fresnel reflection (-45 dB) and high modal purity (>20 dB) using various state-of-the-art HCFs.

16.
Rev Sci Instrum ; 87(5): 053104, 2016 05.
Article En | MEDLINE | ID: mdl-27250389

Coupling light into a vacuum system is a non-trivial problem, requiring the use of a specialized feed-through. This feed-through must be both leak tight and offer a low optical loss if it is to be suitable for general use. In this paper, we report on the development of an extremely simple yet versatile, low cost, demountable optical fiber vacuum feed-through based on the modification of a standard optical fiber bulkhead connector. The modified connector was found to have a leak rate of 6.6 ± 2.1 × 10(-6) mbar l/s and an optical loss of -0.41 ± 0.28 dB, making it suitable for use in high vacuum applications.

...