Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Am Chem Soc ; 145(44): 24071-24080, 2023 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-37857375

RESUMEN

The endogenous opioid system is commonly targeted in pain treatment, but the fundamental nature of neuropeptide release remains poorly understood due to a lack of methods for direct detection of specific opioid neuropeptides in situ. These peptides are concentrated in, and released from, large dense-core vesicles in chromaffin cells. Although catecholamine release from these neuroendocrine cells is well characterized, the direct quantification of opioid peptide exocytosis events has not previously been achieved. In this work, a planar carbon-fiber microelectrode served as a "postsynaptic" sensor for probing catecholamine and neuropeptide release dynamics via amperometric monitoring. A constant potential of 500 mV was employed for quantification of catecholamine release, and a higher potential of 1000 mV was used to drive oxidation of tyrosine, the N-terminal amino acid in the opioid neuropeptides released from chromaffin cells. By discriminating the results collected at the two potentials, the data reveal unique kinetics for these two neurochemical classes at the single-vesicle level. The amplitude of the peptidergic signals decreased with repeat stimulation, as the halfwidth of these signals simultaneously increased. By contrast, the amplitude of catecholamine release events increased with repeat stimulation, but the halfwidth of each event did not vary. The chromogranin dense core was identified as an important mechanistic handle by which separate classes of transmitter can be kinetically modulated when released from the same population of vesicles. Overall, the data provide unprecedented insight into key differences between catecholamine and opioid neuropeptide release from isolated chromaffin cells.


Asunto(s)
Células Cromafines , Neuropéptidos , Analgésicos Opioides/farmacología , Células Cromafines/metabolismo , Catecolaminas , Neuropéptidos/metabolismo , Neuropéptidos/farmacología , Exocitosis/fisiología
2.
ACS Sens ; 8(8): 3187-3194, 2023 08 25.
Artículo en Inglés | MEDLINE | ID: mdl-37552870

RESUMEN

Carbon fiber microelectrodes are commonly used for real-time monitoring of individual exocytosis events at single cells. Since the nature of an electrochemical signal is fundamentally governed by mass transport to the electrode surface, microelectrode geometry can be exploited to achieve precise and accurate measurements. Researchers traditionally pair amperometric measurements of exocytosis with a ∼10-µm diameter, disk microelectrode in an "artificial synapse" configuration to directly monitor individual release events from single cells. Exocytosis is triggered, and released molecules diffuse to the "post-synaptic" electrode for oxidation. This results in a series of distinct current spikes corresponding to individual exocytosis events. However, it remains unclear how much of the material escapes detection. In this work, the performance of 10- and 34-µm diameter carbon fiber disk microelectrodes was directly compared in monitoring exocytosis at single chromaffin cells. The 34-µm diameter electrode was more sensitive to catecholamines and enkephalins than its traditional, 10-µm diameter counterpart, and it more effectively covered the entire cell. As such, the larger sensor detected more exocytosis events overall, as well as a larger quantal size, suggesting that the traditional tools underestimate the above measurements. Both sensors reliably measured l-DOPA-evoked changes in quantal size, and both exhibited diffusional loss upon adjustment of cell-electrode spacing. Finite element simulations using COMSOL support the improved collection efficiency observed using the larger sensor. Overall, this work demonstrates how electrode geometry can be exploited for improved detection of exocytosis events by addressing diffusional loss─an often-overlooked source of inaccuracy in single-cell measurements.


Asunto(s)
Células Cromafines , Exocitosis , Microelectrodos , Fibra de Carbono , Exocitosis/fisiología , Catecolaminas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA