Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 295
1.
Article En | MEDLINE | ID: mdl-38749449

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

2.
Eur Heart J ; 2024 May 15.
Article En | MEDLINE | ID: mdl-38747246

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤ 75 years of age, including both tricuspid and bicuspid AS. METHODS: The NOTION-2 trial enrolled and 1:1 randomized low-risk patients aged ≤ 75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke or rehospitalization (related to the procedure, valve or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group (absolute risk difference 3.1%; 95% confidence interval [CI], -2.7% to 8.8%; hazard ratio (HR) 1.4, 95% CI: 0.7 to 2.9; p=0.3). Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation and moderate-or-greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0, 95% CI: 0.5 to 2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8, 95% CI: 0.8 to 18.5) treated with TAVI or surgery, respectively (P for interaction=0.1). CONCLUSIONS: Among low-risk patients aged ≤ 75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at one year was similar between TAVI and surgery. TAVI outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134).

5.
Article En | MEDLINE | ID: mdl-38795093

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.

6.
Int J Cardiol Heart Vasc ; 52: 101423, 2024 Jun.
Article En | MEDLINE | ID: mdl-38784048

Background: Blood levels of N-terminal pro-B-type natriuretic peptide (NT-proBNP) has been suggested as a future guidance tool for the selection of patients for aortic valve replacement. This study aimed to examine how levels of NT-proBNP pre-transcatheter aortic valve implantation (TAVI) is associated with one-year rates of heart failure (HF) admission and mortality following TAVI. Methods: With Danish nationwide registries, we identified all patients undergoing TAVI from 2014 to 2021 who had at least one recorded NT-pro-BNP measurement within one year before TAVI. Patients were compared by quartiles of pre-TAVI NT-proBNP: quartile 4 (high NT-proBNP group) vs quartile 1-3 (low NT-proBNP group). Comparisons of all-cause mortality and HF-admissions were conducted using Kaplan-Meier analysis, cumulative incidence, and Cox analysis, as appropriate. Results: We identified 1,140 patients undergoing first-time TAVI with a recorded NT-pro-BNP; 846 (74.2 %) with a low NT-proBNP (<420 pmol/L) (55.0 % male, median age 81 year) and 294 (25.8 %) with a high NT-proBNP (≥420 pmol/L) (53.1 % male, median age 82 year). A high versus low NT-proBNP was associated with increased one-year cumulative incidence of HF-admissions (9.1 % vs. 23.1 %, adjusted HR 2.00 [95 % CI, 1.40-2.85]) and all-cause mortality (6.0 % vs. 14.6 %, adjusted HR 1.95 [95 % CI: 1.24-3.07]). A high NT-proBNP was associated with higher rates of outcomes irrespective of previously known atrial fibrillation, HF, chronic kidney disease, and hypertension. Conclusion: In patients undergoing TAVI, a baseline NT-proBNP ≥ 420 pmol/L was associated with increased one-year rates of HF-admission and mortality post-TAVI and may be utilized to identify a high-risk population.

7.
Article En | MEDLINE | ID: mdl-38764320

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. AIMS: To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. METHODS: COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. RESULTS: Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of ≥mild AR. CONCLUSIONS: COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.

8.
Am J Cardiol ; 221: 102-109, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38636623

Transcatheter aortic valve implantation (TAVI) is an established treatment strategy in aortic valve disease. Infolding, as a nonuniform expansion of the prosthesis leading to introflection of part of the device circumference, is a complication specific to self-expandable prostheses. The aim of the study is to determine incidence, predictors, treatment strategy, and outcomes of infolding during Medtronic Evolut TAVI (Minneapolis, MN, US). Between January 2018 and March 2022, all patients treated with Evolut TAVI were included in a multicenter observational retrospective study. According to the occurrence of infolding, the enrolled cohort was divided into 2 groups; periprocedural characteristics and 30-day outcomes were compared. A total of 1,470 patients were included; 23 infolding cases (1.6%) were detected. Preprocedural imaging showed larger aortic anatomy and greater calcium burden in the infolding group. Infolding occurred mostly with Evolut Pro+ and size 34 mm and was diagnosed before full prosthesis release in 78.3%. The rate of moderate-to-severe paravalvular regurgitation was higher in the infolding group (21.7% vs 1.9%, p <0.001). Short-term follow-up showed greater all-cause and cardiovascular mortality (respectively, 4.3% vs 0.7% and 4.3% vs 0.6%, p <0.05) and higher rate of pacemaker implantation (33.3% vs 15.7%, p = 0.042) in case of infolding. High right cusp calcium score and resheathing maneuvers were independent predictors of infolding. In conclusion, prosthesis infolding is a TAVI complication burdened by worse cardiovascular outcomes. Prompt intraprocedural infolding diagnosis is pivotal, especially in case of great native valve calcium burden and resheathing maneuvers, to safely overcome this complication by prosthesis recapture or postdilation.


Aortic Valve Stenosis , Heart Valve Prosthesis , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Retrospective Studies , Aged, 80 and over , Aortic Valve Stenosis/surgery , Incidence , Aged , Prosthesis Failure , Postoperative Complications/epidemiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/epidemiology
9.
Article En | MEDLINE | ID: mdl-38626921

Intraprocedural multimodality imaging, combining TEE with CT-fluoro fusion and ICE, can promote TTVR procedural success by improved guidance of critical steps of the device implantation.

10.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Article En | MEDLINE | ID: mdl-38629416

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Dysfunction, Left , Humans , Aortic Valve/surgery , Heart Ventricles , Stroke Volume , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Ventricular Function, Left , Multicenter Studies as Topic , Clinical Studies as Topic
11.
Catheter Cardiovasc Interv ; 103(5): 766-770, 2024 Apr.
Article En | MEDLINE | ID: mdl-38564317

BACKGROUND: Cardiac damage has gained increasing attention as a valid prognostic marker of mortality after transcatheter aortic valve replacement (TAVR). However, studies investigating the possible association between cardiac damage and hospitalization burden in TAVR patients are lacking. AIMS: This study aimed to investigate the impact of baseline cardiac damage on the hospitalization burden before, during, and after TAVR in an all-comers population. METHODS: All consecutive patients who underwent TAVR between 2016 and 2020 were included. Electronic medical records of all patients were examined to validate cardiovascular (CV) and heart failure (HF) related hospitalizations from 6 months before to 1 year after TAVR. Baseline cardiac damage was defined according to the staging classification by Généreux et al. RESULTS: Among 1397 TAVR patients, 94 (6.7%) had stage 0, 368 (26.4%) stage 1, 736 (52.7%) stage 2, 115 (8.2%) stage 3, and 84 (6.0%) stage 4 cardiac damage. Patients with more advanced cardiac damage at baseline had more HF hospitalizations within 6 months before TAVR (p < 0.01) and with a longer length of stay (LoS) (p < 0.01). Regarding the index TAVR admission, there was no difference in procedure time (p = 0.26) or LoS (p = 0.18) between groups. Still, TAVR patients with more advanced baseline cardiac damage had a higher risk of CV and HF rehospitalization after TAVR (p < 0.05). CONCLUSIONS: Baseline cardiac damage in patients undergoing TAVR has an impact on the pre- and post-procedural cardiovascular hospitalization burden. However, the cardiac damage status does not affect the TAVR procedure time or index TAVR admission length of stay.


Aortic Valve Stenosis , Heart Failure , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/epidemiology , Treatment Outcome , Hospitalization , Length of Stay , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
12.
Int J Cardiol ; 408: 132098, 2024 Aug 01.
Article En | MEDLINE | ID: mdl-38679168

BACKGROUND: Percutaneous left atrial appendage occlusion (LAAO) is increasingly used for stroke prevention in patients with atrial fibrillation and anticoagulant-related complications. Yet, real-life studies evaluating changes in patient characteristics and indications for LAAO remain scarce. METHODS: To evaluate changes in patient characteristics and indications for LAAO defined as 2-year history of intracerebral bleeding, any ischemic stroke/systemic embolism (SE), any non-intracerebral bleeding, other indication, and 1-year mortality. All patients undergoing percutaneous LAAO in Denmark from 2013 to 2021 were stratified into the following year groups: 2013-2015, 2016-2018, and 2019-2021. RESULTS: In total, 1465 patients underwent LAAO. Age remained stable (2013-2015: 74 years versus 2019-2021: 75 years). Patients' comorbidity burden declined, exemplified by CHA2DS2-VASc ≥4 and HAS-BLED ≥3 decreased from 56.7% and 63.7% in 2013-2015 to 40.3% and 45.8% in 2019-2021. Indications for LAAO changed over time with other indication comprising 44.7% in 2019-2021; up from 26.9% in 2013-2015. Conversely, fewer patients had an indication of any ischemic stroke/SE (2013-2015: 30.8% vs 2019-2021: 20.3%) or any non-intracerebral bleeding (2013-2015: 29.4% vs 2019-2021: 23.4%). 1-year mortality was 11.3% for any non-intracerebral bleeding and 6.2% for other indication. CONCLUSION: The LAAO patient-profile has changed considerably. Age remained stable, while comorbidity burden decreased during the period 2013-2021. LAAO is increasingly used in patients with no clinical event history and mortality differs according to indication. Selection of patients to LAAO should be done carefully, and contemporary real-life studies investigating clinical practice could add important insights.


Atrial Appendage , Atrial Fibrillation , Humans , Atrial Appendage/surgery , Male , Aged , Female , Atrial Fibrillation/mortality , Atrial Fibrillation/surgery , Aged, 80 and over , Denmark/epidemiology , Mortality/trends , Stroke/mortality , Stroke/prevention & control , Middle Aged , Cardiac Catheterization/trends , Cardiac Catheterization/methods , Follow-Up Studies , Registries
13.
Article En | MEDLINE | ID: mdl-38448258

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.

14.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Article En | MEDLINE | ID: mdl-38479968

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Registries , Stroke/etiology
15.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Article En | MEDLINE | ID: mdl-38479966

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Aortic Valve Stenosis , Embolic Protection Devices , Ischemic Stroke , Stroke , Transcatheter Aortic Valve Replacement , Humans , Ischemic Stroke/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Treatment Outcome , Stroke/diagnostic imaging , Stroke/etiology , Stroke/prevention & control , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
16.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Article En | MEDLINE | ID: mdl-38401656

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Aortic Valve Stenosis , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Male , Female , Aortic Valve Stenosis/surgery , Sex Factors , Aged, 80 and over , Aged , Treatment Outcome , Postoperative Complications/epidemiology , Aortic Valve/surgery
18.
Eur Heart J ; 45(13): 1116-1124, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38321820

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become a viable treatment option for patients with severe aortic valve stenosis across a broad range of surgical risk. The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize patients at lower surgical risk to TAVI or surgical aortic valve replacement (SAVR). The aim of the present study was to report clinical and bioprosthesis outcomes after 10 years. METHODS: The NOTION trial randomized 280 patients to TAVI with the self-expanding CoreValve (Medtronic Inc.) bioprosthesis (n = 145) or SAVR with a bioprosthesis (n = 135). The primary composite outcome was the risk of all-cause mortality, stroke, or myocardial infarction. Bioprosthetic valve dysfunction (BVD) was classified as structural valve deterioration (SVD), non-structural valve dysfunction (NSVD), clinical valve thrombosis, or endocarditis according to Valve Academic Research Consortium-3 criteria. Severe SVD was defined as (i) a transprosthetic gradient of 30 mmHg or more and an increase in transprosthetic gradient of 20 mmHg or more or (ii) severe new intraprosthetic regurgitation. Bioprosthetic valve failure (BVF) was defined as the composite rate of death from a valve-related cause or an unexplained death following the diagnosis of BVD, aortic valve re-intervention, or severe SVD. RESULTS: Baseline characteristics were similar between TAVI and SAVR: age 79.2 ± 4.9 years and 79.0 ± 4.7 years (P = .7), male 52.6% and 53.8% (P = .8), and Society of Thoracic Surgeons score < 4% of 83.4% and 80.0% (P = .5), respectively. After 10 years, the risk of the composite outcome all-cause mortality, stroke, or myocardial infarction was 65.5% after TAVI and 65.5% after SAVR [hazard ratio (HR) 1.0; 95% confidence interval (CI) 0.7-1.3; P = .9], with no difference for each individual outcome. Severe SVD had occurred in 1.5% and 10.0% (HR 0.2; 95% CI 0.04-0.7; P = .02) after TAVI and SAVR, respectively. The cumulative incidence for severe NSVD was 20.5% and 43.0% (P < .001) and for endocarditis 7.2% and 7.4% (P = 1.0) after TAVI and SAVR, respectively. No patients had clinical valve thrombosis. Bioprosthetic valve failure occurred in 9.7% of TAVI and 13.8% of SAVR patients (HR 0.7; 95% CI 0.4-1.5; P = .4). CONCLUSIONS: In patients with severe AS and lower surgical risk randomized to TAVI or SAVR, the risk of major clinical outcomes was not different 10 years after treatment. The risk of severe bioprosthesis SVD was lower after TAVR compared with SAVR, while the risk of BVF was similar.


Aortic Valve Stenosis , Endocarditis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Myocardial Infarction , Stroke , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Aged, 80 and over , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Myocardial Infarction/etiology , Stroke/epidemiology , Stroke/etiology , Endocarditis/surgery , Thrombosis/etiology
19.
EuroIntervention ; 20(2): e158-e167, 2024 Jan 15.
Article En | MEDLINE | ID: mdl-38224253

BACKGROUND: Both surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) are Class Ia recommended therapies for specific subgroups of severe aortic stenosis (AS) patients in the latest 2021 European guidelines. AIMS: We aimed to report on the multidisciplinary Heart Team evaluation process and real-world practice of treating severe symptomatic AS in East Denmark in the context of the latest European guideline recommendations. METHODS: All consecutive patients with severe AS referred for intervention in 2021 (N=672) were discussed in a multidisciplinary Heart Team meeting. All patients (100%) had a cardiac computed tomography (CT) analysis prior to the meeting. Baseline characteristics, Heart Team decision-making, final treatment and 30-day clinical outcomes were prospectively recorded. RESULTS: The majority of severe AS patients (N=456, 68%) were referred for TAVI following discussion in the Heart Team. Ultimately, 94% of patients (N=632) received the Heart Team-recommended treatment. Patients undergoing TAVI (N=439) were significantly older (78.4±6.7 vs 67.2±8.3 years; p<0.001) and more comorbid than patients undergoing SAVR (N=189). The overall 30-day clinical outcomes were satisfactory for both treatment groups (overall 30-day mortality: 1.1%). The mean index hospitalisation length was markedly longer in the SAVR group (8.6±8.3 days) as compared to the TAVI group (1.8±3.2 days). CONCLUSIONS: TAVI was routinely performed in low surgical risk patients in 2021 with two-thirds of all severe AS patients undergoing TAVI, thereby applying the latest European guidelines. A dedicated Heart Team meeting, including CT evaluation for all AS patients, is needed to make individualised management decisions in this new era of aortic valve interventions.


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Heart , Hospitalization , Patients , Aortic Valve Stenosis/surgery
20.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38244892

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Aortic Valve Stenosis , Balloon Valvuloplasty , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Balloon Valvuloplasty/methods , Calcium , Treatment Outcome , Retrospective Studies , Prosthesis Design
...