Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 8 de 8
1.
J Med Internet Res ; 23(7): e26151, 2021 07 12.
Article En | MEDLINE | ID: mdl-34255661

BACKGROUND: Over half a million individuals are diagnosed with head and neck cancer each year globally. Radiotherapy is an important curative treatment for this disease, but it requires manual time to delineate radiosensitive organs at risk. This planning process can delay treatment while also introducing interoperator variability, resulting in downstream radiation dose differences. Although auto-segmentation algorithms offer a potentially time-saving solution, the challenges in defining, quantifying, and achieving expert performance remain. OBJECTIVE: Adopting a deep learning approach, we aim to demonstrate a 3D U-Net architecture that achieves expert-level performance in delineating 21 distinct head and neck organs at risk commonly segmented in clinical practice. METHODS: The model was trained on a data set of 663 deidentified computed tomography scans acquired in routine clinical practice and with both segmentations taken from clinical practice and segmentations created by experienced radiographers as part of this research, all in accordance with consensus organ at risk definitions. RESULTS: We demonstrated the model's clinical applicability by assessing its performance on a test set of 21 computed tomography scans from clinical practice, each with 21 organs at risk segmented by 2 independent experts. We also introduced surface Dice similarity coefficient, a new metric for the comparison of organ delineation, to quantify the deviation between organ at risk surface contours rather than volumes, better reflecting the clinical task of correcting errors in automated organ segmentations. The model's generalizability was then demonstrated on 2 distinct open-source data sets, reflecting different centers and countries to model training. CONCLUSIONS: Deep learning is an effective and clinically applicable technique for the segmentation of the head and neck anatomy for radiotherapy. With appropriate validation studies and regulatory approvals, this system could improve the efficiency, consistency, and safety of radiotherapy pathways.


Deep Learning , Head and Neck Neoplasms , Algorithms , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/radiotherapy , Humans , Tomography, X-Ray Computed
2.
BMJ Open ; 11(6): e047709, 2021 06 28.
Article En | MEDLINE | ID: mdl-34183345

INTRODUCTION: Standards for Reporting of Diagnostic Accuracy Study (STARD) was developed to improve the completeness and transparency of reporting in studies investigating diagnostic test accuracy. However, its current form, STARD 2015 does not address the issues and challenges raised by artificial intelligence (AI)-centred interventions. As such, we propose an AI-specific version of the STARD checklist (STARD-AI), which focuses on the reporting of AI diagnostic test accuracy studies. This paper describes the methods that will be used to develop STARD-AI. METHODS AND ANALYSIS: The development of the STARD-AI checklist can be distilled into six stages. (1) A project organisation phase has been undertaken, during which a Project Team and a Steering Committee were established; (2) An item generation process has been completed following a literature review, a patient and public involvement and engagement exercise and an online scoping survey of international experts; (3) A three-round modified Delphi consensus methodology is underway, which will culminate in a teleconference consensus meeting of experts; (4) Thereafter, the Project Team will draft the initial STARD-AI checklist and the accompanying documents; (5) A piloting phase among expert users will be undertaken to identify items which are either unclear or missing. This process, consisting of surveys and semistructured interviews, will contribute towards the explanation and elaboration document and (6) On finalisation of the manuscripts, the group's efforts turn towards an organised dissemination and implementation strategy to maximise end-user adoption. ETHICS AND DISSEMINATION: Ethical approval has been granted by the Joint Research Compliance Office at Imperial College London (reference number: 19IC5679). A dissemination strategy will be aimed towards five groups of stakeholders: (1) academia, (2) policy, (3) guidelines and regulation, (4) industry and (5) public and non-specific stakeholders. We anticipate that dissemination will take place in Q3 of 2021.


Artificial Intelligence , Diagnostic Tests, Routine , Humans , London , Research Design , Research Report
5.
Nat Med ; 26(6): 892-899, 2020 06.
Article En | MEDLINE | ID: mdl-32424211

Progression to exudative 'wet' age-related macular degeneration (exAMD) is a major cause of visual deterioration. In patients diagnosed with exAMD in one eye, we introduce an artificial intelligence (AI) system to predict progression to exAMD in the second eye. By combining models based on three-dimensional (3D) optical coherence tomography images and corresponding automatic tissue maps, our system predicts conversion to exAMD within a clinically actionable 6-month time window, achieving a per-volumetric-scan sensitivity of 80% at 55% specificity, and 34% sensitivity at 90% specificity. This level of performance corresponds to true positives in 78% and 41% of individual eyes, and false positives in 56% and 17% of individual eyes at the high sensitivity and high specificity points, respectively. Moreover, we show that automatic tissue segmentation can identify anatomical changes before conversion and high-risk subgroups. This AI system overcomes substantial interobserver variability in expert predictions, performing better than five out of six experts, and demonstrates the potential of using AI to predict disease progression.


Deep Learning , Geographic Atrophy/diagnostic imaging , Tomography, Optical Coherence , Wet Macular Degeneration/diagnosis , Aged , Aged, 80 and over , Disease Progression , Early Diagnosis , Early Medical Intervention , Female , Humans , Imaging, Three-Dimensional , Macular Degeneration/diagnostic imaging , Male , Prognosis , Wet Macular Degeneration/diagnostic imaging , Wet Macular Degeneration/therapy
6.
Nature ; 577(7788): 89-94, 2020 01.
Article En | MEDLINE | ID: mdl-31894144

Screening mammography aims to identify breast cancer at earlier stages of the disease, when treatment can be more successful1. Despite the existence of screening programmes worldwide, the interpretation of mammograms is affected by high rates of false positives and false negatives2. Here we present an artificial intelligence (AI) system that is capable of surpassing human experts in breast cancer prediction. To assess its performance in the clinical setting, we curated a large representative dataset from the UK and a large enriched dataset from the USA. We show an absolute reduction of 5.7% and 1.2% (USA and UK) in false positives and 9.4% and 2.7% in false negatives. We provide evidence of the ability of the system to generalize from the UK to the USA. In an independent study of six radiologists, the AI system outperformed all of the human readers: the area under the receiver operating characteristic curve (AUC-ROC) for the AI system was greater than the AUC-ROC for the average radiologist by an absolute margin of 11.5%. We ran a simulation in which the AI system participated in the double-reading process that is used in the UK, and found that the AI system maintained non-inferior performance and reduced the workload of the second reader by 88%. This robust assessment of the AI system paves the way for clinical trials to improve the accuracy and efficiency of breast cancer screening.


Artificial Intelligence/standards , Breast Neoplasms/diagnostic imaging , Early Detection of Cancer/methods , Early Detection of Cancer/standards , Female , Humans , Mammography/standards , Reproducibility of Results , United Kingdom , United States
7.
Nat Med ; 24(9): 1342-1350, 2018 09.
Article En | MEDLINE | ID: mdl-30104768

The volume and complexity of diagnostic imaging is increasing at a pace faster than the availability of human expertise to interpret it. Artificial intelligence has shown great promise in classifying two-dimensional photographs of some common diseases and typically relies on databases of millions of annotated images. Until now, the challenge of reaching the performance of expert clinicians in a real-world clinical pathway with three-dimensional diagnostic scans has remained unsolved. Here, we apply a novel deep learning architecture to a clinically heterogeneous set of three-dimensional optical coherence tomography scans from patients referred to a major eye hospital. We demonstrate performance in making a referral recommendation that reaches or exceeds that of experts on a range of sight-threatening retinal diseases after training on only 14,884 scans. Moreover, we demonstrate that the tissue segmentations produced by our architecture act as a device-independent representation; referral accuracy is maintained when using tissue segmentations from a different type of device. Our work removes previous barriers to wider clinical use without prohibitive training data requirements across multiple pathologies in a real-world setting.


Deep Learning , Referral and Consultation , Retinal Diseases/diagnosis , Aged , Clinical Decision-Making , Female , Humans , Male , Middle Aged , Retina/diagnostic imaging , Retina/pathology , Retinal Diseases/diagnostic imaging , Tomography, Optical Coherence
8.
F1000Res ; 5: 1573, 2016.
Article En | MEDLINE | ID: mdl-27830057

There are almost two million people in the United Kingdom living with sight loss, including around 360,000 people who are registered as blind or partially sighted. Sight threatening diseases, such as diabetic retinopathy and age related macular degeneration have contributed to the 40% increase in outpatient attendances in the last decade but are amenable to early detection and monitoring. With early and appropriate intervention, blindness may be prevented in many cases. Ophthalmic imaging provides a way to diagnose and objectively assess the progression of a number of pathologies including neovascular ("wet") age-related macular degeneration (wet AMD) and diabetic retinopathy. Two methods of imaging are commonly used: digital photographs of the fundus (the 'back' of the eye) and Optical Coherence Tomography (OCT, a modality that uses light waves in a similar way to how ultrasound uses sound waves). Changes in population demographics and expectations and the changing pattern of chronic diseases creates a rising demand for such imaging. Meanwhile, interrogation of such images is time consuming, costly, and prone to human error. The application of novel analysis methods may provide a solution to these challenges. This research will focus on applying novel machine learning algorithms to automatic analysis of both digital fundus photographs and OCT in Moorfields Eye Hospital NHS Foundation Trust patients. Through analysis of the images used in ophthalmology, along with relevant clinical and demographic information, DeepMind Health will investigate the feasibility of automated grading of digital fundus photographs and OCT and provide novel quantitative measures for specific disease features and for monitoring the therapeutic success.

...