Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Environ Res ; 250: 118514, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38373545

RESUMEN

Osteoporosis is the most common bone disease, characterized by decreased bone mineral density (BMD) and often associated to decreased muscle mass and function. Metal exposure plays a role in the pathophysiology of osteoporosis and affects also muscle quality. The aim of this study was to assess the association between metal levels in bone and muscle samples and the degeneration of these tissues. A total of 58 subjects (30 male and 28 female) was enrolled and classified in osteoporotic (OP, n = 8), osteopenic (Ope, n = 30) and healthy (CTR, n = 20) subjects, according to BMD measures. Femoral head bone samples and vastus lateralis muscle samples were collected during hip arthroplasty surgeries. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) analysis showed increased levels of Al, Cd and Pb in OP and Ope bone tissue compared to CTR subjects (p = 0.04, p = 0.005 and p = 0.01, respectively). Whereas, increased levels of Co, Cd and Pb were measured in OP and Ope muscle tissues, compared to CTRs (p < 0.001, p = 0.02 and p = 0.01, respectively). In addition, Al, Cd and Pb levels in bone and Cd and Co levels in muscle were negatively correlated with BMD. A negative association among Co, Cd, Cr and Hg levels and muscle fibers diameter was also observed in muscle tissues. This study assessed that metal exposure can affects bone and muscle tissue quality and may contribute to the onset and progression of musculoskeletal diseases such as osteoporosis. Therefore, it is important to implement metal exposure assessment and their impact on disease development, in order to manage and prevent metal accumulation effects on bone and muscle quality.


Asunto(s)
Densidad Ósea , Osteoporosis , Humanos , Proyectos Piloto , Femenino , Masculino , Osteoporosis/metabolismo , Osteoporosis/inducido químicamente , Anciano , Persona de Mediana Edad , Metales/metabolismo , Metales/análisis , Huesos/metabolismo , Huesos/química , Músculo Esquelético/metabolismo
2.
Life (Basel) ; 13(6)2023 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-37374131

RESUMEN

We quantitatively and qualitatively evaluated the bacterial contamination of mobile phones (MPs) in relation to users' demographics, habits, and device characteristics by administering questionnaires to 83 healthcare university students and sampling their MPs by following a cross-sectional design. The heterotrophic plate count (HPC) at 22 °C (HPC 22 °C) and 37 °C (HPC 37 °C), Enterococci, Gram-negative bacteria, and Staphylococci were evaluated. Higher bacterial loads were detected for HPC 37 °C and Staphylococci (416 and 442 CFU/dm2, respectively), followed by HPC 22 °C, Enterococci, and Gram-negative bacteria; the vast majority of samples were positive for HPC 37 °C, HPC 22 °C, and Staphylococci (98%), while Enterococci (66%) and Gram-negative bacteria (17%) were detected less frequently. A statistically significant positive correlation (r = 0.262, p < 0.02) was found between the European head specific absorption rate (SAR) and both HPC 37 °C and Staphylococci; Enterococci showed a strong, significant correlation with HPC 37 °C, HPC 22 °C, and Gram-negative bacteria (r = 0.633, 0.684, 0.884) and a moderate significant correlation with Staphylococci (r = 0.390). Significant differences were found between HPC 22 °C and the type of internship attendance, with higher loads for Medicine. Students with a daily internship attendance had higher HPC 22 °C levels than those attending <6 days/week. Our study showed that bacteria can survive on surfaces for long periods, depending on the user's habits and the device's characteristics.

3.
PLoS One ; 18(3): e0282019, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36961857

RESUMEN

INTRODUCTION: Healthcare-associated infections (HAIs) and antimicrobial resistance (AMR) are major public health threats in upper- and lower-middle-income countries. Electronic health records (EHRs) are an invaluable source of data for achieving different goals, including the early detection of HAIs and AMR clusters within healthcare settings; evaluation of attributable incidence, mortality, and disability-adjusted life years (DALYs); and implementation of governance policies. In Italy, the burden of HAIs is estimated to be 702.53 DALYs per 100,000 population, which has the same magnitude as the burden of ischemic heart disease. However, data in EHRs are usually not homogeneous, not properly linked and engineered, or not easily compared with other data. Moreover, without a proper epidemiological approach, the relevant information may not be detected. In this retrospective observational study, we established and engineered a new management system on the basis of the integration of microbiology laboratory data from the university hospital "Policlinico Tor Vergata" (PTV) in Italy with hospital discharge forms (HDFs) and clinical record data. All data are currently available in separate EHRs. We propose an original approach for monitoring alert microorganisms and for consequently estimating HAIs for the entire period of 2018. METHODS: Data extraction was performed by analyzing HDFs in the databases of the Hospital Information System. Data were compiled using the AREAS-ADT information system and ICD-9-CM codes. Quantitative and qualitative variables and diagnostic-related groups were produced by processing the resulting integrated databases. The results of research requests for HAI microorganisms and AMR profiles sent by the departments of PTV from 01/01/2018 to 31/12/2018 and the date of collection were extracted from the database of the Complex Operational Unit of Microbiology and then integrated. RESULTS: We were able to provide a complete and richly detailed profile of the estimated HAIs and to correlate them with the information contained in the HDFs and those available from the microbiology laboratory. We also identified the infection profile of the investigated hospital and estimated the distribution of coinfections by two or more microorganisms of concern. Our data were consistent with those in the literature, particularly the increase in mortality, length of stay, and risk of death associated with infections with Staphylococcus spp, Pseudomonas aeruginosa, Klebsiella pneumoniae, Clostridioides difficile, Candida spp., and Acinetobacter baumannii. Even though less than 10% of the detected HAIs showed at least one infection caused by an antimicrobial resistant bacterium, the contribution of AMR to the overall risk of increased mortality was extremely high. CONCLUSIONS: The increasing availability of health data stored in EHRs represents a unique opportunity for the accurate identification of any factor that contributes to the diffusion of HAIs and AMR and for the prompt implementation of effective corrective measures. That said, artificial intelligence might be the future of health data analysis because it may allow for the early identification of patients who are more exposed to the risk of HAIs and for a more efficient monitoring of HAI sources and outbreaks. However, challenges concerning codification, integration, and standardization of health data recording and analysis still need to be addressed.


Asunto(s)
Antiinfecciosos , Infección Hospitalaria , Humanos , Inteligencia Artificial , Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , Hospitales Universitarios , Factores de Riesgo
4.
Healthcare (Basel) ; 10(11)2022 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-36421594

RESUMEN

The burden, microbial etiology and clinical impact of hospital-acquired respiratory infections (HARIs) were determined at an Italian teaching hospital over a 12-month period. For this purpose, overall ordinary hospitalizations ≥ 2 days of subjects over 18 years old with discharge from 1 January 2018 to 31 December 2018 were examined by cross-referencing demographic and clinical data from hospital discharge forms with microbiological data from the computer system of the Microbiology Unit. We identified 329 individuals with HARIs (96 females and 233 males; median age 70 years, range 18−93), who represented » of the total hospital-acquired infections (HAIs) in the period. The inpatient setting was medical and surgical in similar proportions (169 vs. 160, respectively) and the mean hospital stay was 38.9 ± 33.6 days. One hundred and forty patients (42.6% of the total sample) were suffering from one or more chronic diseases. A total of 581 microorganisms (82 antibiotic-resistant and 499 non-resistant) were detected in HARI patients. The most common isolated species were Staphylococcus aureus (16.7%), Klebsiella pneumoniae (13.3%), Pseudomonas spp. (12.6%) and Acinetobacter baumannii (10.5%), followed by Enterobacter spp. (5.3%), Escherichia coli (5.2%) and Enterococcus spp. (4.8%). One hundred and sixty-seven individuals (49.0% of the total) had polymicrobial infections. One hundred thirty-one patients (39.8% of the total) underwent endotracheal intubation and mechanical ventilation and 62.6% of them died, compared to 17.7% of the non-intubated patients. Multivariable analysis confirmed a positive correlation between death and increased age (p = 0.05), surgical MDC (p = 0.007), number of microorganisms over the sample mean (p = 0.001), the presence of chronic diseases (p = 0.046), and intubation and mechanical ventilation (p < 0.0001). A positive correlation between intubation and antibiotic-resistant organisms (p = 0.003) was also found. HARIs are still a major public health problem and require constant surveillance due to their severe clinical outcome.

5.
Ig Sanita Pubbl ; 79(2): 92-110, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35781296

RESUMEN

Legionella and Pseudomonas aeruginosa are pathogens that live and multiply in water systems and resist disinfection through biofilm formation. As suggested by some studies, we wanted to verify whether the presence of P. aeruginosa can lead to a less frequent presence of Legionella in water systems of retirement homes and group homes. We collected 123 hot water and biofilm samples from showerheads. Samples were tested by selective culture methods, and Heterotrophic Plate Counts were determined. Legionella and P. aeruginosa were found in 35% and 39% of distal points, respectively. The presence of P. aeruginosa was significantly inversely correlated with the presence of Legionella when considering both matrices together (p<0.01), water samples only (p=0.02), and biofilm samples only (p=0.04). The inverse relationship was strong for L. pneumophila sg1 (Odds Ratio 0.182, p=0.002), while it is no longer verified when only L. pneumophila serogroups 2-14 are considered. The implications for the development of environmental investigations and risk management are discussed.


Asunto(s)
Legionella pneumophila , Legionella , Humanos , Pseudomonas aeruginosa , Instituciones Residenciales , Agua , Microbiología del Agua , Abastecimiento de Agua
6.
Toxicol Appl Pharmacol ; 446: 116056, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35537546

RESUMEN

The study of developmental effect of xenobiotics in humans is limited and often relies on epidemiological data. Whether and to which extent potentially toxic compounds may cross the placental barrier, and whether adverse effects on embryo development are the consequence of direct or indirect placental-mediated action is debated. The availability of in vitro models simulating the feto-maternal interface could contribute to elucidate this issue. Here, we report the development of a novel in vitro model using murine blastocyst derived trophoblast stem cells (TSC) to mimic the placental barrier and mouse embryoid bodies (EBs) to represent the embryonic tissues. We demonstrate that this model can be used for translocation studies, as well as embryotoxicity assessment of titanium dioxide nanoparticles (TiO2NPs). By evaluating trans-epithelial electrical resistance, translocation of fluorescein isothiocyanate-dextran beads and expression of junctional complex proteins, we show that TSCs cultured on transwell inserts under differentiating condition form syncytia. We also show that TiO2NPs administered in the upper transwell compartment are able to reach the lower compartment and interfere with EB differentiation when no TSC are cultured on the insert. On the contrary, when TSC are present, NPs translocate to a lesser extent and do not affect EB development. These results indicate that the proposed in vitro model is suitable to study the correlation between translocation and toxicity of TiO2NPs and suggest a direct effect of the particles on EB development. We propose that this model could be exploited to study developmental effect of other xenobiotics.


Asunto(s)
Nanopartículas del Metal , Placenta , Titanio , Animales , Femenino , Nanopartículas del Metal/toxicidad , Ratones , Placenta/metabolismo , Embarazo , Titanio/toxicidad , Xenobióticos/metabolismo
7.
Materials (Basel) ; 14(10)2021 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-34064903

RESUMEN

Bacterial adhesion to the surface of orthodontic materials is an important step in the formation and proliferation of plaque bacteria, which is responsible for enamel demineralization and periodontium pathologies. With the intent of investigating if adhesive resins used for bracket bonding are prone to bacteria colonization, the surface roughness of these materials has been analyzed, combining information with a novel methodology to observe the internal structures of orthodontic composites. Scanning electron microscopy, combined with focus ion bean micromachining and stylus profilometry analyses, were performed to evaluate the compositional factors that can influence specific pivotal properties facilitating the adhesion of bacteria to the surface, such as surface roughness and robustness of three orthodontic adhesive composite resins. To confirm these findings, contact angle measurements and bacteria incubation on resin slide have been performed, evaluating similarities and differences in the final achievement. In particular, the morphological features that determine an increase in the resins surface wettability and influence the bacterial adhesion are the subject of speculation. Finally, the focused ion beam technique has been proposed as a valuable tool to combine information coming from surface roughness with specific the internal structures of the polymers.

9.
Microorganisms ; 8(7)2020 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-32707676

RESUMEN

Mobile phones (MPs) are commonly used both in the personal and professional life. We assessed microbiological contamination of MPs from 108 students in healthcare professions (HPs), in relation to their demographic characteristics and MPs handling habits, collected by means of a questionnaire. Cultural and biochemical tests were performed, and statistical analyses were carried out. Staphylococci were present in 85% of MPs, Enterococci in 37%, Coliforms in 6.5%; E. coli was never detected. Staphylococcus epidermidis was the most frequently isolated staphylococcal species (72% of MPs), followed by S. capitis (14%), S. saprophyticus, S. warneri, S. xylosus (6%), and by S. aureus (4%). Heterotrophic Plate Counts (HPC) at 37 °C, ranged from 0 to 1.2 × 104 CFU/dm2 (mean = 362 CFU/dm2). In univariate analysis, the male gender only was significantly associated with higher HPCs and enterococcal contamination. Multiple linear regression models explained only 17% and 16% of the HPC 37 °C and staphylococcal load variability, respectively. Developing specific guidelines for a hygienic use of MPs in clinical settings, for preventing cross-infection risks, is advisable, as well as introducing specific training programs to HP students. MPs decontamination procedures could also be implemented in the community.

10.
Microorganisms ; 8(4)2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32244685

RESUMEN

Respiratory tract infections account for high morbidity and mortality around the world. Fragile patients are at high risk of developing complications such as pneumonia and may die from it. Limited information is available on the extent of the circulation of respiratory viruses in the hospital setting. Most knowledge relates to influenza viruses (FLU) but several other viruses produce flu-like illness. The study was conducted at the University Hospital Policlinico Tor Vergata, Rome, Italy. Clinical and laboratory data from hospitalized patients with respiratory tract infections during the period October 2016-March 2019 were analysed. The retrospective analysis included 17 viral agents detected by FilmArray test and clinical data from medical records and hospital discharge sheets. Models were adjusted for relevant confounders such as clinical severity and risk of death, socio-demographic characteristics and surgical procedures. From a total of 539 specimens analysed, 180 (33.39%) were positive for one or more respiratory viruses. Among them, 83 (46.1 %) were positive for influenza viruses (FLU), 36 (20%) rhino/enteroviruses (RHV/EV), 17 (9.44%) human coronaviruses (HCOV-229E, -HKU1, -NL63, and -OC43), 17 (9.44%) respiratory syncytial virus, 15 (8.33%) human metapneumovirus (HMPV), 8 (4.44%) parainfluenza viruses (PIV) and 4 (2.22%) adenoviruses (ADV). The distribution of viral agents varied across age groups and month of detection. The positive specimens were from 168 patients [102 M, 66 F; median age (range): 64 years (19-93)]. Overall, 40% of them had a high-grade clinical severity and a 27% risk of death; 27 patients died and 22 of them (81.5%) had received a clinical diagnosis of pneumonia. Respiratory viral infections may have a severe course and a poor prognosis in hospitalized patients, due to underlying comorbidities. Monitoring the circulation of respiratory viruses in hospital settings is important to improve diagnosis, prevention and treatment.

11.
Sci Rep ; 9(1): 12598, 2019 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-31467322

RESUMEN

Virological analysis is time-consuming and expensive. The aim of this work is to demonstrate the applicability of laser-induced fluorescence (LIF) to the classification of viruses, reducing the time for this analysis and its costs. Experimental tests were performed in which different viruses were irradiated with a UV laser emitting at 266 nm and the emitted spectra were recorded by a spectrometer. The classification techniques show the possibility of discriminating viruses. Although the application of the LIF technique to biological agents has been thoroughly studied by many researchers over the years, this work aims at validating for the first time its applicability to virological analyses. The development of a fast virological analysis may revolutionize this field, allowing fast responses to epidemiologic events, reducing their risks and improving the efficiency of monitoring environments. Moreover, a cost reduction may lead to an increase in the monitoring frequency, with an obvious enhancement of safety and prevention.


Asunto(s)
Monitoreo del Ambiente/métodos , Rayos Láser , Picornaviridae/clasificación , Espectrometría de Fluorescencia , Redes Neurales de la Computación , Máquina de Vectores de Soporte , Factores de Tiempo
12.
Data Brief ; 19: 2364-2373, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30229110

RESUMEN

The data presented in this article are related to the research paper titled "Prevalence of Legionella in retirement homes and group homes water distribution systems" (De Filippis, 2018) [3]. Most of the cases of Legionella infection are sporadic and occur in community-dwellers. Hot water and biofilm samples from the showerheads of 26 retirement homes and 9 group homes hosting closed communities were collected, in order to evaluate the prevalence of Legionella and generic water quality parameters (Heterotrophic Plate Counts at 22 °C and 37 °C). Samples were tested by culture method for the presence of Legionella. Confirmation and identification were carried out through Latex test and PCR. Further data about buildings' number of floors and rooms were collected, and put in relation to the presence of Legionella through constructing contingency tables and performing exact fisher׳s or Chi-square tests. Cold (< 30 °C) water samples are analyzed apart.

13.
Sci Total Environ ; 643: 715-724, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29957436

RESUMEN

BACKGROUND: Although historically the focus has been placed above all on hospital infections and travel-associated outbreaks, most of the cases of Legionella infection are sporadic and occur in community-dwellers. OBJECTIVES: To evaluate the presence and load of Legionella in hot water systems of non-healthcare facilities that host closed communities. Furthermore, we tried to verify the association between Heterotrophic Plate Counts (HPCs) and presence of Legionella. METHODS: We collected hot water and biofilm samples from the showerheads of retirement homes and group homes. Samples were tested by culture method for the presence of Legionella. Confirmation and identification were carried out through Latex test and PCR. We determined the HPCs at 22 and 37 °C by the pour plate method. Statistics performed through STATA. RESULTS: We collected 140 hot water and biofilm samples, 95 from 26 retirement homes and 35 from 9 group homes. Legionella was found in 36.8% samples collected from retirement homes and only in 10.3% group homes' samples (p = 0.01). Legionella was identified more frequently in water than in biofilm (29.8% vs 16.9%); just in one case the pathogen was found in the biofilm only. L. pneumophila sg 1 was the pathogen more frequently isolated (65.8%), with an average load of 2720 CFU/L (SD = 8393 CFU/L). We have often noticed a high microbial contamination (67% of HPCs >200 CFU/mL) and identified a higher prevalence of Legionella for intermediate values of HPC 22 °C (p = 0.011). 32% of people hosted in retirement homes were exposed to Legionella. CONCLUSIONS: Colonization of water-systems of retirement homes and group homes is anything but occasional, and in our survey it mainly affects the former, moreover often due to L. pneumophila sg 1. The search for the pathogen in the biofilm has proved to be of little use. The relationship between HPC and Legionella deserves further studies.


Asunto(s)
Exposición a Riesgos Ambientales/estadística & datos numéricos , Hogares para Grupos , Legionella , Jubilación , Microbiología del Agua , Abastecimiento de Agua , Calor , Humanos , Legionella pneumophila , Enfermedad de los Legionarios/epidemiología , Prevalencia , Agua
14.
J Water Health ; 15(3): 402-409, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28598344

RESUMEN

Critical environments, including water systems in recreational settings, represent an important source of Legionella pneumophila infection in humans. In order to assess the potential risk for legionellosis, we analyzed Legionella contamination of water distribution systems in 36 recreational facilities equipped with swimming pools. One hundred and sixty water samples were analyzed from shower heads or taps located in locker rooms or in bathrooms. By culture method and polymerase chain reaction, 41/160 samples were positive for Legionella from 12/36 recreational centers. Hotels (57.1%) and sports centers (41.2%) were the most contaminated. L. pneumophila serotypes 2-14 (25/41) were more frequently found than serotype 1 (10/41). Samples at temperature ≥30 °C were more frequently positive than samples at temperature <30 °C (n = 39 vs n = 2, p < 0.00001). The presence of L. pneumophila was investigated by comparison with heterotrophic plate count (HPC), an indicator of water quality. The presence of L. pneumophila was associated more frequently with high and intermediate HPC load at 37 °C, therefore should be considered a potential source when HPC at 37 °C is >10 CFU/mL. Maintenance, good hygiene practices, interventions on the hydraulic system and regular controls must be implemented to minimize exposure to L. pneumophila infection risk.


Asunto(s)
Legionella pneumophila/aislamiento & purificación , Piscinas , Cuartos de Baño , Microbiología del Agua , Italia , Legionella pneumophila/clasificación , Legionella pneumophila/inmunología , Ciudad de Roma , Abastecimiento de Agua
15.
Ig Sanita Pubbl ; 63(1): 21-9, 2007.
Artículo en Italiano | MEDLINE | ID: mdl-17401447

RESUMEN

The aim of this study was to evaluate the quality of dialysis water used in dialysis units of various hospitals and private clinics in Rome and the Lazio region (Italy). The study was performed between January 2000 and December 2004. A total of 507 samples were analysed, 205 of which obtained from public hospitals and 302 from privately-owned medical facilities. Microbiological analysis was performed as specified by the 1995 Decree of the Lazio Region n degrees 1650, which also sets threshold values for bacterial contamination and minimum frequency of inspections. The decree also specifies the modalities and frequency of disinfection of dialysis water treatment and distribution systems. The findings show a superior microbiological quality of dialysis water in privately-owned dialysis units. This may be due to several factors but especially to a more regular maintenance and disinfection of the water treatment systems. Overall, over half of the samples analysed, in both types of facilities, showed bacterial loads well below the set limits. In our view, however, bacterial limits for dialysis water are too high especially considering the fact that they are the same limits set by previous regulations for drinkable water. Haemodialysis patients are exposed to large volumes of water used for the production of dialysis fluids during a treatment session. It is therefore clearly important that more stringent limits for bacterial contamination be introduced.


Asunto(s)
Contaminación de Medicamentos , Soluciones para Hemodiálisis , Diálisis Renal , Instituciones de Atención Ambulatoria , Hospitales , Humanos , Italia , Sector Privado
16.
Ig Sanita Pubbl ; 61(5): 467-74, 2005.
Artículo en Italiano | MEDLINE | ID: mdl-17206217

RESUMEN

In 1995 the regional council of the Lazio region passed Decree N.1650 which regulates the maintenance of dialysis equipment and sets limiting values for microbiological and chemical parameters used to assess the quality of water used for dialysis fluids. As regards the microbiological parameters, limiting values were set for total bacterial count and endotoxins. However, in recent literature, serious health effects following dialysis have been described; these suggest the advisability of including testing for more specific microorganisms and of testing greater samples of dialysis water. In this study, conducted over 2 years, in addition to normal microbiological parameters, dialysis fluids were tested for the presence of bacteria of the Pseudomonas species. Results show that samples which met the standards for dialysis water set by legislation were actually found to be contaminated by Pseudomonas species.


Asunto(s)
Pseudomonas aeruginosa/aislamiento & purificación , Diálisis Renal , Microbiología del Agua , Agua/normas , Recuento de Colonia Microbiana , Endotoxinas/análisis , Humanos , Italia , Prueba de Limulus , Control de Calidad , Microbiología del Agua/normas
17.
Ig Sanita Pubbl ; 59(6): 365-72, 2003.
Artículo en Italiano | MEDLINE | ID: mdl-15116148

RESUMEN

The microbiological quality of the air indoor is influenced from various factors and one of the most important is represented from the maintenance of the conditioning systems. In this study it has been estimated the effectiveness of an intervention of cleaning and maintenance on the systems of conditioning of an university building executing sampling before and after such intervention. The two results were confronted and it is observed as the maintenance of the air conditioners has influenced on the quality of the air indoor.


Asunto(s)
Aire Acondicionado/instrumentación , Microbiología del Aire , Contaminación del Aire Interior , Contaminación de Equipos , Mantenimiento/estadística & datos numéricos , Universidades , Contaminación de Equipos/prevención & control , Contaminación de Equipos/estadística & datos numéricos , Laboratorios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA