Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 13(9)2024 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-38731118

RESUMEN

Aim: To assess the medium and long-term performance of the Endurant stent graft in a cohort of consecutive patients treated with this device for an abdominal aortic aneurysm (AAA) both inside and outside of the instructions for use (IFU) and to find factors influencing the outcomes. Methods: Our observational, retrospective, single-center study included all patients who consecutively underwent endovascular aneurysm repair with the Endurant stent graft from February 2009 to January 2023. Patients with an AAA to treat according to current guidelines were included. Patients were divided into two groups: Group 1 inside of the IFUs and Group 2 outside of the IFUs for the proximal aortic neck. Patients were followed up after the procedure with computed angiography tomography, ultrasound examination, and interviews. Aneurysm-related mortality, procedure-related reinterventions, and type IA and III endoleaks were considered primary endpoints. Secondary endpoints included aneurysmal sac variations and graft thrombosis. Results: A total of 795 patients were included, 650 in Group 1 and 145 in Group 2; 732 were males, and the mean age was 74 ± 8. Anamnestic baseline did not differ between the two groups. Neck length, width, and angulation were different between the two groups (all p < 0.001). A total of 40 patients had a ruptured AAA, while 56 were symptomatic. At a mean follow-up of 43 ± 39 months, aneurysm-related mortality was less than 1%, and 82 endoleak (10.5%) were observed. Overall endoleak rate and type 1A endoleak, as well as procedure-related reintervention, were significantly more frequent in Group 2. Sac regression of at least 5 mm was observed in 65.9% of cases. AAAs larger than 60.5 mm carried a higher risk of endoleak (HR: 1.025; 95% CI: 1.013-1.37; p < 0.001) and proximal necks shorter than 13.5 mm carried a higher type 1A risk (HR: 0.890; 95% CI: 0.836-0.948; p < 0.001). Patients without chronic obstructive pulmonary disease and taking lipid-lowering drugs had an overall more consistent sac-shrinking rate. Conclusions: The Endurant stent graft proves safe and reliable. Out-of-IFU treatment has poorer medium and long-term outcomes. Some conditions influence medium and long-term reintervention risk and sac behavior. Patients with bigger aneurysms, proximal necks shorter than 13.5 mm, and chronic obstructive pulmonary disease should be more carefully evaluated during follow-up. Consistent follow-up is in keeping low aneurysm-related mortality. Personalized risk profiles and peri and postoperative management strategies are needed.

2.
J Vasc Surg Cases Innov Tech ; 10(2): 101436, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38435789

RESUMEN

An aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysms (AAAs) and constitute <1% of all AAAs, which increases from 2% to 6.7% in ruptured AAAs. Unlike other aortic ruptures, most ACFs are not associated with significant blood loss on admission. The traditional treatment strategy has been open surgery, which is associated with a high mortality rate. Endovascular repair has been performed; however, the results are difficult to interpret due to the low incidence of ACFs and the absence of cases reported with a long follow-up duration. We report the case of a 78-year-old man with previous endovascular aneurysm repair performed in 2015, who presented to our emergency department 6 years later with abdominal pain. A computed tomography angiography scan showed type Ia, Ib, and II endoleaks and an ACF. The endoleaks were selectively treated, and the ACF was covered with a polytetrafluoroethylene endograft inserted in the inferior vena cava. In our single-case experience with a medium-term follow-up of 24 months, our treatment was safe and effective for ACF closure, with no further signs of endoleak or graft thrombosis. We conducted a literature review of reported cases in which a covered stent graft was used for ACF treatment. Although no guidelines are currently available regarding this rare late complication after endovascular aneurysm repair, using a covered stent placed in the inferior vena cava to treat an ACF could be a viable option in selected cases.

3.
Heart Rhythm ; 21(8): 1267-1276, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38246567

RESUMEN

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.


Asunto(s)
Anticoagulantes , Apéndice Atrial , Fibrilación Atrial , Puntaje de Propensión , Humanos , Masculino , Femenino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Apéndice Atrial/cirugía , Anciano , Anticoagulantes/administración & dosificación , Anticoagulantes/uso terapéutico , Administración Oral , Medición de Riesgo/métodos , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/epidemiología , Factores de Riesgo , Estudios de Seguimiento , Estudios Prospectivos , Incidencia , Resultado del Tratamiento , Tromboembolia/prevención & control , Tromboembolia/etiología , Tromboembolia/epidemiología , Anciano de 80 o más Años
4.
J Clin Med ; 11(19)2022 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-36233407

RESUMEN

Background: Atrial fibrillation (AF) and heart failure (HF) often coexist and synergistically contribute to an increased risk of hospitalization, stroke, and mortality. Objective: To compare the efficacy of catheter ablation (CA) versus medical therapy (MT) in HF patients with AF. Methods: Electronic databases were queried for randomized controlled trials (RCTs) of CA versus MT of AF in patients with HF. Risk ratios (RRs), mean differences (MDs), and 95% confidence intervals (CIs) were measured using the Mantel−Haenszel method. Results: A total of nine RCTs enrolling 2155 patients met the inclusion criteria. Compared to MT, CA led to a significant reduction in the composite of all-cause mortality and HF hospitalization (24.6% vs. 37.1%; RR: 0.65 (95% CI: 0.53−0.80); p < 0.0001), all-cause mortality (8.8% vs. 13.6%; RR: 0.65 (95% CI: 0.51−0.82); p = 0.0005), HF hospitalization (15.4% vs. 22.4%; (RR: 0.67 (95% CI: 0.54−0.82); p = 0.0001), AF recurrence (31.8% vs. 77.0%; RR: 0.36 (95% CI: 0.24−0.54); p < 0.0001), and cardiovascular (CV) death (4.9% vs. 8.4%; RR: 0.58 (95% CI: 0.39−0.86); p = 0.007). CA improved the left ventricular ejection fraction (MD:4.76% (95% CI: 2.35−7.18); p = 0.0001), 6 min walk test (MD: 20.48 m (95% CI: 10.83−30.14); p < 0.0001), peak oxygen consumption (MD: 3.1 2mL/kg/min (95% CI: 1.01−5.22); p = 0.004), Minnesota Living with Heart Failure Questionnaire score (MD: −6.98 (95% CI: −12−03, −1.93); p = 0.007), and brain natriuretic peptide levels (MD:−133.94 pg/mL (95% CI: −197.33, −70.55); p < 0.0001). Conclusions: In HF patients, AF catheter ablation was superior to MT in reducing CV and all-cause mortality. Further significant benefits occurred within the ablation group in terms of HF hospitalizations, AF recurrences, the systolic function, exercise capacity, and quality of life.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA