Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Br J Radiol ; 89(1058): 20150603, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26585543

RESUMEN

OBJECTIVE: To determine if subsets of patients may benefit from smaller or larger margins when using laser setup and bony anatomy verification of breast tumour bed (TB) boost radiotherapy (RT). METHODS: Verification imaging data acquired using cone-beam CT, megavoltage CT or two-dimensional kilovoltage imaging on 218 patients were used (1574 images). TB setup errors for laser-only setup (dlaser) and for bony anatomy verification (dbone) were determined using clips implanted into the TB as a gold standard for the TB position. Cases were grouped by centre-, patient- and treatment-related factors, including breast volume, TB position, seroma visibility and surgical technique. Systematic (Σ) and random (σ) TB setup errors were compared between groups, and TB planning target volume margins (MTB) were calculated. RESULTS: For the study population, Σlaser was between 2.8 and 3.4 mm, and Σbone was between 2.2 and 2.6 mm, respectively. Females with larger breasts (p = 0.03), easily visible seroma (p ≤ 0.02) and open surgical technique (p ≤ 0.04) had larger Σlaser. Σbone was larger for females with larger breasts (p = 0.02) and lateral tumours (p = 0.04). Females with medial tumours (p < 0.01) had smaller Σbone. CONCLUSION: If clips are not used, margins should be 8 and 10 mm for bony anatomy verification and laser setup, respectively. Individualization of TB margins may be considered based on breast volume, TB and seroma visibility. ADVANCES IN KNOWLEDGE: Setup accuracy using lasers and bony anatomy is influenced by patient and treatment factors. Some patients may benefit from clip-based image guidance more than others.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/radioterapia , Tomografía Computarizada de Haz Cónico/métodos , Errores de Configuración en Radioterapia/prevención & control , Adulto , Anciano , Anciano de 80 o más Años , Puntos Anatómicos de Referencia , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Posicionamiento del Paciente , Fotones , Interpretación de Imagen Radiográfica Asistida por Computador , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen , Reino Unido
2.
Radiother Oncol ; 109(3): 482-6, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24128804

RESUMEN

BACKGROUND AND PURPOSE: To measure the geometric uncertainty resulting from intra-fraction motion and intra-observer image matching, for patients having image-guided prostate radiotherapy on TomoTherapy. MATERIAL AND METHODS: All patients had already been selected for prostate radiotherapy on TomoTherapy, with daily MV-CT imaging. The study involved performing an additional MV-CT image at the end of treatment, on 5 occasions during the course of 37 treatments. 54 patients were recruited to the study. A new formula was derived to calculate the PTV margin for intra-fraction motion. RESULTS: The mean values of the intra-fraction differences were 0.0mm, 0.5mm, 0.5mm and 0.0° for LR, SI, AP and roll, respectively. The corresponding standard deviations were 1.1mm, 0.8mm, 0.8mm and 0.6° for systematic uncertainties (Σ), 1.3mm, 2.0mm, 2.2mm and 0.3° for random uncertainties (σ). This intra-fraction motion requires margins of 2.2mm in LR, 2.1mm in SI and 2.1mm in AP directions. Inclusion of estimates of the effect of rotations and matching errors increases these margins to approximately 4mm in LR and 5mm in SI and AP directions. CONCLUSIONS: A new margin recipe has been developed to calculate margins for intra-fraction motion. This recipe is applicable to any measurement technique that is based on the difference between images taken before and after treatment.


Asunto(s)
Neoplasias de la Próstata/patología , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Masculino , Movimiento (Física) , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen , Radioterapia de Intensidad Modulada/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA