Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
J Cardiovasc Surg (Torino) ; 65(3): 195-204, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39007553

RESUMEN

BACKGROUND: In contemporary clinical practice, carotid artery stenting (CAS) is increasingly becoming a multispecialty field, joining operators of various training backgrounds, which bring forth their unique expertise, patient management philosophies, and procedural preferences. The best practices and approaches, however, are still debated. Therefore, real-world insights on different operator preferences and related outcomes are of utmost value, yet still rather scarce in the available literature. METHODS: Using the data collected in the ROADSAVER observational, European multicenter CAS study, a prespecified comparative analysis evaluating the impact of the operator's specialization was performed. We used major adverse event (MAE) rate at 30-day follow-up, defined as the cumulative incidence of any death or stroke, and its components as outcome measures. RESULTS: A total of 1965 procedures were analyzed; almost half 878 (44.7%) were performed by radiologists (interventional/neuro), 717 (36.5%) by cardiologists or angiologists, and 370 (18.8%) by surgeons (vascular/neuro). Patients treated by surgeons were the oldest (72.9±8.5), while radiologists treated most symptomatic patients (58.1%) and more often used radial access (37.2%). The 30-day MAE incidence achieved by cardiologists/angiologists was 2.0%, radiologists 2.5%, and surgeons 1.9%; the observed differences in rates were statistically not-significant (P=0.7027), even when adjusted for baseline patient/lesion and procedural disparities across groups. The corresponding incidence rates for death from any cause were 1.0%, 0.8%, and 0.3%, P=0.4880, and for any stroke: 1.4%, 2.3%, and 1.9%, P=0.4477, respectively. CONCLUSIONS: Despite the disparities in patient selection and procedural preferences, the outcomes achieved by different specialties in real-world, contemporary CAS practice remain similar when using modern devices and techniques.


Asunto(s)
Procedimientos Endovasculares , Radiólogos , Stents , Accidente Cerebrovascular , Humanos , Anciano , Masculino , Femenino , Resultado del Tratamiento , Europa (Continente) , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/epidemiología , Factores de Tiempo , Factores de Riesgo , Estenosis Carotídea/terapia , Estenosis Carotídea/mortalidad , Estenosis Carotídea/cirugía , Cirujanos , Pautas de la Práctica en Medicina , Cardiólogos , Anciano de 80 o más Años , Disparidades en Atención de Salud , Especialización , Competencia Clínica , Persona de Mediana Edad , Medición de Riesgo
2.
J Vasc Surg ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38604319

RESUMEN

OBJECTIVE: In two randomized controlled trials, the outcomes of endovascular treatment of complex femoropopliteal arterial lesions were compared with bypass surgery and considered a valid alternative treatment. The aim of this study was to compare both endovascular treatment options with the hypothesis that implantation of heparin-bonded self-expanding covered stents (Viabahn [SECS]) or drug-eluting stents (ZilverPTX [DES]) are related to similar clinical outcomes at 1-year follow-up. METHODS: In a post-hoc analysis, the SuperB trial and Zilverpass databases were merged. Patients in the endovascular treatment arms were included, and data was analyzed in an intention-to-treat (ITT) and a per-protocol (PP) fashion. Data included baseline and lesion characteristics, procedural details, and follow-up data. The primary endpoint of this study was primary patency at 1-year follow-up. The secondary endpoints were secondary patency, target lesion revascularization (TLR), limb loss, and all-cause mortality. RESULTS: A total of 176 patients were included; 63 in the SECS arm and 113 in the DES arm. Through 1-year follow-up, there were no significant differences in primary patency (ITT: 63.4% vs 71.1%: P = .183 and PP: 60.8% vs 71.1%; P = .100). Secondary patency rates were not significantly different in the ITT analysis (86.5% vs 95.1%; P = .054), but in the PP analysis, there was a significant difference in favor of the DES group (SECS, 85.6% vs DES, 95.1%; P = .038). There was no significant difference in freedom from TLR between groups (79.6% vs 77.0%; P = .481). No major amputations were performed in the SECS group, and two were performed in the DES group (1.8%). Survival rate was 98.2% in the SECS group, and 91.3% in the DES group after 1-year follow-up (P = .106). Based on diagnosis (intermittent claudication vs chronic limb-threatening ischemia) no differences between patients with intermittent claudication and chronic limb-threatening ischemia were observed in primary patency, secondary patency and freedom from TLR. CONCLUSIONS: Treatment of complex femoropopliteal arterial disease with the heparin-bonded Viabahn endoprosthesis and the Zilver PTX drug-eluting stent are related to similar primary and secondary patency, and TLR rates at 1 year, except for secondary patency in the PP analysis. This study further supports the endovascular treatment of long complex lesions in the femoropopliteal artery.

4.
Eur J Vasc Endovasc Surg ; 67(6): 923-932, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38447693

RESUMEN

OBJECTIVE: There is a need for improved outcomes in the endovascular treatment of patients suffering from chronic limb threatening ischaemia (CLTI), highly calcified lesions, and chronic total occlusions (CTOs). The helical centreline self expanding BioMimics 3D stent might be particularly useful in these high risk subsets, combining flexibility and fracture resistance with radial strength. Herein, the performance of the BioMimics 3D stent was assessed in these high risk subsets. METHODS: MIMICS-3D is a prospective, multicentre, European real world registry. This was a post hoc analysis, comparing patients with CLTI vs. intermittent claudication (IC), lesions with bilateral calcification vs. those without (peripheral arterial calcium scoring system [PACSS] 3,4 vs. PACSS 0 - 2), and CTO vs. no CTO. Propensity score matching was performed to reduce the impact of baseline variables. The 36 month endpoints were clinically driven target lesion revascularisation (CD-TLR), death, major target limb amputation, and stent patency. RESULTS: A total of 507 patients were enrolled. At 36 months, patients with CLTI had lower freedom from major amputation than patients with IC (92.6% vs. 100%, p < .001). In terms of primary patency, patients with CTO had lower patency rates than those without (63.9% vs. 77.8%, p = .003), but the difference reduced after propensity score matching (70.5% vs. 76.8%, p = .43). Primary patency was not impaired for patients with PACSS 3,4 or patients with CLTI. Freedom from CD-TLR was not significantly different among the groups and was 73.8% for CLTI vs. 78.9% for IC (p = .15), 77.6% for PACSS 3,4 vs. 78.7% for PACSS 0 - 2 (p = .55), and 75.6% for CTO vs. 81.0% for no CTO (p = .11). CONCLUSIONS: The outcome of the MIMICS-3D registry suggests that the BioMimics 3D stent is effective in the endovascular treatment of complex femoropopliteal lesions and in CLTI. Future randomised controlled trials should confirm its non-inferiority or superiority compared with existing alternatives.


Asunto(s)
Aleaciones , Sistema de Registros , Humanos , Masculino , Femenino , Anciano , Estudios Prospectivos , Persona de Mediana Edad , Amputación Quirúrgica , Resultado del Tratamiento , Isquemia Crónica que Amenaza las Extremidades/cirugía , Enfermedad Arterial Periférica/fisiopatología , Enfermedad Arterial Periférica/terapia , Enfermedad Arterial Periférica/diagnóstico por imagen , Diseño de Prótesis , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Grado de Desobstrucción Vascular , Recuperación del Miembro , Factores de Tiempo , Anciano de 80 o más Años , Stents , Europa (Continente) , Factores de Riesgo , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia
5.
J Clin Med ; 13(6)2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38541860

RESUMEN

Background: The BIO REACT study is designed to investigate the incremental value of Extravascular UltraSound (EVUS) added to conventional angiography, compared to conventional angiography only for the identification of Flow-Limiting Dissections (FLD) and to evaluate the safety and efficacy of the REsponse Adapted Combination Therapy (REACT) for the treatment of femoropopliteal lesions. Methods: The primary endpoints were the specificity and sensitivity of EVUS added to angiography for the detection of FLD. Secondary endpoints were primary patency of the REACT therapy within 12 months, fCD-TLR, freedom from MAE, major target limb amputations (mTLA) and survival rates within 24 months. Results: A total of 150 patients were included. EVUS added to angiography had an overall sensitivity of 29% and specificity of 93% for the detection of FLD. There was no PSVR cut-off offering a clinically acceptable trade-off between meaningful sensitivity and specificity values for the detection of FLD. At 12 months, treatment with the REACT resulted in primary patency and fCD-TLR of 81.6% and 94.3%, respectively. In addition, freedom from MAE was 94.3% at 12 months. At 24 months, the survival rate was 94.0%. No mTLA was reported up to the 24-month follow-up. Conclusions: The addition of DUS to angiography showed limited value for detecting FLD in femoropopliteal artery disease.

7.
JACC Cardiovasc Interv ; 16(23): 2900-2914, 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-38092496

RESUMEN

BACKGROUND: There is a scarcity of published head-to-head comparisons between different paclitaxel-coated angioplasty balloons. More prospective safety data to support the health care economic reimbursement processes are needed. OBJECTIVES: The aim of this study was to report the safety and efficacy of the Passeo-18 Lux drug-coated balloon (DCB) (Biotronik AG) for the treatment of symptomatic peripheral artery disease caused by stenosis, restenosis, or occlusion of the femoral and/or popliteal arteries. METHODS: A total of 302 patients were randomized 1:1 and assigned to the Passeo-18 Lux DCB (study device) group or the IN.PACT Admiral DCB (control device, Medtronic Vascular) group for testing of noninferiority. The primary efficacy endpoint was freedom from clinically driven target lesion revascularization at 12 months. The primary safety endpoint was a composite of freedom from device-/procedure-related death through 30 days postindex procedure, major target limb amputation, and clinically driven target vessel revascularization at 12 months. RESULTS: At 12 months, 130 of 134 patients in the IN.PACT Admiral group had freedom from clinically driven target lesion revascularization (97.0%) compared with 137 of 141 patients in the Passeo-18 Lux group (97.2%). The primary safety endpoint showed 96.3% in the control group vs 95.7% in the study device group. The null hypothesis of inferiority on both efficacy and safety was rejected. The Kaplan-Meier estimate of primary patency at 1 year was 88.7% in the control arm vs 91.5% in the study device arm. CONCLUSIONS: The Passeo-18 Lux and the IN.PACT Admiral DCBs demonstrate comparable results with excellent effectiveness and safety through 12 months for femoropopliteal interventions.


Asunto(s)
Angioplastia de Balón , Enfermedad Arterial Periférica , Humanos , Arteria Femoral/diagnóstico por imagen , Resultado del Tratamiento , Paclitaxel/efectos adversos , Estudios Prospectivos , Materiales Biocompatibles Revestidos , Factores de Tiempo , Arteria Poplítea/diagnóstico por imagen , Angioplastia de Balón/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Grado de Desobstrucción Vascular
8.
Cardiovasc Intervent Radiol ; 46(10): 1348-1358, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37670198

RESUMEN

PURPOSE: To report the 60-month safety and effectiveness results of a multicenter, prospective, randomized controlled trial comparing the ZILVER PTX paclitaxel-eluting stent to prosthetic above-the-knee bypass for the treatment of symptomatic TransAtlantic Inter-Society Consensus (TASC) C and D femoropopliteal lesions. MATERIALS AND METHODS: Patients were enrolled between October 2013 and July 2017. One of the secondary outcomes was primary patency at 60 months, defined as no evidence of binary restenosis or occlusion within the target lesion or bypass graft based on a duplex ultrasound peak systolic velocity ratio < 2.4 and no clinically-driven target lesion revascularization (TLR) in endovascular cases or reintervention to restore flow in the bypass at 60 months. Survival rates after 5 years were also analyzed. RESULTS: 220 patients (mean age 68.6 ± 10.5 years; 159 men) were included and randomized to ZILVER PTX (n = 113, 51.40%) or BYPASS group (n = 107, 48.60%). The 60-month primary patency rate was 49.3% for the ZILVER PTX group versus 40.7% for the bypass group (p = 0.6915). Freedom from TLR was 63.8% for the ZILVER PTX group versus 52.8% for the bypass group (p = 0.2637). At 5 years, no significant difference in survival rate could be seen between the ZILVER PTX and the bypass group (69.1% vs. 71% respectively, p = 0.5503). CONCLUSION: Even at 5 years, non-inferior safety and effectiveness results of the ZILVER PTX could be seen. These findings confirmed that the use of ZILVER PTX stents can be considered as a valid alternative for bypass surgery when treating long and complex femoropopliteal lesions.


Asunto(s)
Stents Liberadores de Fármacos , Enfermedad Arterial Periférica , Masculino , Humanos , Persona de Mediana Edad , Anciano , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/cirugía , Grado de Desobstrucción Vascular , Recurrencia Local de Neoplasia , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Stents , Paclitaxel , Diseño de Prótesis
9.
Expert Rev Med Devices ; 20(9): 715-720, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37486180

RESUMEN

INTRODUCTION: Radial access is the standard of care for nearly all cardiac catheterization procedures. It improves patient satisfaction, reduces the length of stay, and is associated with fewer complications. However, few devices and tools are available for the treatment of peripheral arterial disease via a transradial approach (TRA). The S.M.A.R.T. RADIANZ Vascular Stent System is among the RADIANZ suite of products, which is aimed at expanding the portfolio of devices to treat peripheral arterial disease. AREAS COVERED: In this Expert review, the following areas will be covered: (1) Current Landscape of peripheral vascular intervention (PVI) using TRA (2) Detailed description of the S.M.A.R.T. RADIANZ Vascular Stent System. (3) Ongoing clinical trials to evaluate safety of this approach. (4) Future directions and current regulatory status. EXPERT OPINION: TRA for PVI is a promising approach. It holds the possibility of substantially improving the care of patients with peripheral arterial disease (PAD). Numerous challenges must be overcome to realize the full potential of a radial-to-peripheral (RTP) approach. The length of devices and the small sheath size are the main constraints of this approach. The results of the ongoing RADIANCY trial will demonstrate the safety, in selected patients, of the RADIANZ suite of products.


Asunto(s)
Cateterismo Periférico , Procedimientos Endovasculares , Enfermedad Arterial Periférica , Humanos , Resultado del Tratamiento , Arteria Radial/cirugía , Cateterismo Periférico/métodos , Enfermedad Arterial Periférica/cirugía , Stents
10.
J Cardiovasc Surg (Torino) ; 64(4): 413-421, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37162238

RESUMEN

BACKGROUND: To report the 3-year safety and effectiveness results of a multicenter, prospective, randomized controlled trial comparing the ZILVER PTX paclitaxel-eluting stent to surgical bypass and to conduct a health economic analysis up to 3-year follow-up of the two treatment modalities. METHODS: This is a study in symptomatic TransAtlantic Inter-Society Consensus (TASC) C and D femoropopliteal lesions comparing endovascular ZILVER PTX stenting vs. surgical bypass surgery using a prosthetic graft (ClinicalTrials.gov identifier NCT01952457). Between October 2013 and July 2017, 220 patients (mean age 68.6±10.5 years; 159 men) were enrolled and randomized to the ZILVER PTX treatment group (113, 51.40%) or the bypass treatment group (107, 48.60%). One of the secondary outcomes was primary patency at 3-year, defined as no evidence of binary restenosis or occlusion within the target lesion or bypass graft based on a duplex ultrasound peak systolic velocity ratio <2.4 and no clinically-driven target lesion revascularization (TLR) in endovascular cases or reintervention to restore flow in the bypass. An economic analysis was conducted to analyze the cost differences between ZILVER PTX and bypass, which shows the perspective of the public authority/organization that pays for healthcare in the two countries (payor), Germany and USA. RESULTS: The 3-year primary patency rate was 53.30% (95% CI 61.40% to 45.20%) for the ZILVER PTX group vs. 58.20% (95% CI 67.10% to 49.30%) for the bypass arm (P=0.9721). Freedom from TLR at 3-year was 62.80% (95% CI 72.60% to 53%) for the ZILVER PTX group vs. 65.30% (95% CI 75.40% to 55.20%) for the bypass group (P=0.635). There was also no significant difference (P=0.358) in survival rate at 3-year between the ZILVER PTX group 78.50%, (95% CI to 87.70% to 69.30%) and the bypass group 87.40% (95% CI 97.6% to 77.2%). None of the deaths was categorized as related to the procedure or device. The economic analysis, taking into account procedural-, hospitalization- and reintervention costs, showed a clear cost-benefit for Zilver PTX in both investigated countries up to 3-year follow-up: Germany (Bypass €9446 per patient versus ZILVER PTX €5755) and USA (Bypass $26,373 per patient versus ZILVER PTX $19,186). CONCLUSIONS: The non-inferior safety and effectiveness results of the ZILVER PTX stent were associated with lower costs for the payer and confirmed that ZILVER PTX stent treatment can be considered as a valid alternative for bypass surgery in long and complex femoropopliteal lesions.


Asunto(s)
Stents Liberadores de Fármacos , Enfermedad Arterial Periférica , Masculino , Humanos , Persona de Mediana Edad , Anciano , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/cirugía , Grado de Desobstrucción Vascular , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Stents , Paclitaxel
11.
J Cardiovasc Dev Dis ; 10(3)2023 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-36975890

RESUMEN

BACKGROUND: Through its helical centreline geometry, the BioMimics 3D vascular stent system is designed for the mobile femoropopliteal region, aiming to improve long-term patency and the risk of stent fractures. METHODS: MIMICS 3D is a prospective, European, multi-centre, observational registry to evaluate the BioMimics 3D stent in a real-world population through 3 years. A propensity-matched comparison was performed to investigate the effect of the additional use of drug-coated balloons (DCB). RESULTS: The MIMICS 3D registry enrolled 507 patients (518 lesion, length 125.9 ± 91.0 mm). At 3 years, the overall survival was 85.2%, freedom from major amputation 98.5%, freedom from clinically driven target lesion revascularisation 78.0%, and primary patency 70.2%. The propensity-matched cohort included 195 patients in each cohort. At 3-year follow-up, there was no statistically significant difference in clinical outcomes, such as overall survival (87.9% in the DCB vs. 85.1% in the no DCB group), freedom from major amputation (99.4% vs. 97.2%), clinically driven TLR (76.4% vs. 80.3%), and primary patency (68.5% vs. 74.4%). CONCLUSION: The MIMICS 3D registry showed good 3-year outcomes of the BioMimics 3D stent in femoropopliteal lesions, demonstrating the safety and performance of this device under real-world conditions, whether used alone or in combination with a DCB.

12.
Cardiovasc Intervent Radiol ; 45(12): 1855-1859, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36058996

RESUMEN

PURPOSE: Although effectiveness and safety of many different paclitaxel coated balloons in the treatment of peripheral arterial disease (PAD) are extensively studied, there is a lack of direct head-to-head comparison studies. To meet this need and to avoid potential "class-effects", the BIOPACT was set up. The purpose is to demonstrate the safety and efficacy of the Passeo-18 Lux DCB (Biotronik) for treatment of patients with symptomatic PAD due to femoropopliteal lesions. METHODS: 302 patients are randomized in a 1:1 manner to treatment with either the Passeo-18 Lux DCB or the IN.PACT Admiral DCB (Medtronic) for testing of a formal non-inferiority hypothesis. The participants will be followed for 5 years. The primary efficacy endpoint is freedom from clinically-driven target lesion revascularization (CD-TLR) at 12 months, defined as any re-intervention at the target lesion due to symptoms, drop of ankle brachial index (ABI) > 20% or > 0.15 compared to post-procedural ABI. Primary safety endpoint is a composite of freedom from device/procedure-related death through 30 days post-index procedure, freedom from major target limb amputation and clinically-driven target vessel revascularization (CD-TVR) through 12 months post-index procedure. Secondary endpoints can be found at clinicaltrials.gov, ID NCT03884257. DISCUSSION: As full enrolment was reached by the beginning of September, the investigators expect complete analysis of the primary endpoints by the end of 2022; Meanwhile preliminary results will be disclosed during 2022. As in terms of randomized head-to-head efficacy and safety analysis, this study on paclitaxel coated balloons may provide additional information to clinicians and healthcare providers. Trial registration ClinicalTrials.gov ID: NCT03884257 LEVEL OF EVIDENCE: Level 2, Randomized trial.


Asunto(s)
Angioplastia de Balón , Enfermedad Arterial Periférica , Humanos , Arteria Poplítea/diagnóstico por imagen , Angioplastia de Balón/efectos adversos , Materiales Biocompatibles Revestidos , Grado de Desobstrucción Vascular , Factores de Tiempo , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/patología , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Paclitaxel/efectos adversos , Resultado del Tratamiento
13.
Surg Technol Int ; 422022 12 30.
Artículo en Inglés | MEDLINE | ID: mdl-36602184

RESUMEN

A thyroglossal duct cyst (TGDC) is the result of incomplete degeneration of the thyroglossal duct during gestation. It is the most common type of congenital cyst of the neck, and is usually seen in children. The tumor mostly appears at the midline of the neck and generally causes no symptoms, but the mass typically moves when the patient swallows. We present the unusual case of a 50-year-old man with a large cervical mass lateralized on the right side of the neck. There was no association between swallowing and movement of the mass. Clinical examination and computed tomography (CT) suggested a lymphangioma or cystic hygroma. Surgical resection showed a large cyst of 71 x 40 x 52 mm with no attachment to the hyoid bone and no invasion in blood vessels or other surrounding tissue. Histopathological investigation led to a diagnosis of TGDC.

15.
Cardiovasc Intervent Radiol ; 44(5): 689-697, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33367944

RESUMEN

PURPOSE: Ambulatory peripheral vascular interventions have been steadily increasing. In ambulatory procedures, 4F devices might be particularly useful having the potential to reduce access-site complications; however, further evidence on their safety and efficacy is needed. MATERIALS AND METHODS: BIO4AMB is a prospective, non-randomized mulitcentre, non-inferiority trial conducted in 35 centres in Europe and Australia comparing the use of 4F- and 6F-compatible devices. The main exclusion criteria included an American Society of Anaesthesiologists class ≥ 4, coagulation disorders, or social isolation. The primary endpoint was access-site complications within 30 days. RESULTS: The 4F group enrolled 390 patients and the 6F group 404 patients. Baseline characteristics were similar between the groups. Vascular closure devices were used in 7.7% (4F group) and 87.6% (6F group) of patients. Patients with vascular closure device use in the 4F group were subsequently excluded from the primary analysis, resulting in 361 patients in the 4F group. Time to haemostasis was longer for the 4F group, but the total procedure time was shorter (13.2 ± 18.8 vs. 6.4 ± 8.9 min, p < 0.0001, and 39.1 ± 25.2 vs. 46.4 ± 27.6 min, p < 0.0001). Discharge on the day of the procedure was possible in 95.0% (4F group) and 94.6% (6F group) of patients. Access-site complications were similar between the groups (2.8% and 3.2%) and included predominantly groin haematomas and pseudoaneurysms. Major adverse events through 30 days occurred in 1.7% and 2.0%, respectively. CONCLUSIONS: Ambulatory peripheral vascular interventions are feasible and safe. The use of 4F devices resulted in similar outcomes compared to that of 6F devices.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Arteria Femoral/cirugía , Técnicas Hemostáticas/instrumentación , Dispositivos de Cierre Vascular , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento
16.
J Cardiovasc Surg (Torino) ; 61(5): 617-625, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33231029

RESUMEN

BACKGROUND: This clinical trial aims to evaluate the outcome (up to 24-months) of the treatment of in-stent restenotic or reoccluded lesions in the femoropopliteal arteries, by comparing the treatment of the GORE® VIABAHN® Endoprosthesis with PROPATEN Bioactive Surface (W. L. Gore & Associates, Flagstaff, AZ, USA) with a standard PTA treatment. The primary effectiveness endpoint of the study is the primary patency at 12 months, defined as no evidence of restenosis or occlusion within the originally treated lesion based on color-flow duplex ultrasound (PSVR≤2.5) and without target lesion revascularization (TLR) within 12 months. The primary safety endpoint is the proportion of subjects who experience serious device-related adverse events within 30 days postprocedure. METHODS: A total of 83 patients meeting inclusion and exclusion criteria have been enrolled in this prospective, randomized, multicenter, controlled study in 7 sites between June 2010 and February 2012. Patients with an in-stent restenosis lesion in the femoropopliteal region and a Rutherford classification from 2 to 5 could be enrolled. After screening, the patient was randomized to either treatment with the GORE® VIABAHN® Endoprosthesis with PROPATEN Bioactive Surface or treatment with a standard PTA balloon. After the index procedure, follow-up visits at 1 month, 6 months, 12 months and 24 months were required. A color flow Doppler ultrasound was performed on all follow-up visits and a quantitative vascular angiography at the 12-month follow-up visit. RESULTS: In the VIABAHN® group, 39 patients (74.4% male; mean age 67.69±9.77 years) were enrolled and in the PTA group, 44 patients (72.7% male; mean age 68.98±9.71 years) were enrolled, which is comparable for both treatment groups. In the VIABAHN® group, 34 (87.2%) patients presented with claudication (Rutherford 2 and 3) and 5 (12.8%) patients had critical limb ischemia (Rutherford 4 and 5). In the PTA group, 36 (81.8%) patients were claudicants (Rutherford 2 and 3) and 8 (18.2%) presented with critical limb ischemia (Rutherford 4 and 5). The 12-month primary patency rates were 74.8% for the VIABAHN® group and 28.0% for the PTA group (P<0.001). No patients were reported to have device-related serious adverse events within 30 days postprocedure. The primary patency rate for the 24-month follow-up was 58.40% in the Viabahn group and 11.60% in the PTA group (P<0.001). CONCLUSIONS: The treatment of femoropopliteal in-stent restenosis with a VIABAHN® Endoprosthesis shows significantly better results than the treatment with a standard PTA balloon. This demonstrates that the use of the VIABAHN® Endoprosthesis is a very promising tool for the treatment of complex in-stent restenosis.


Asunto(s)
Angioplastia de Balón/instrumentación , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Arteria Femoral/cirugía , Enfermedad Arterial Periférica/terapia , Stents , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Bélgica , Implantación de Prótesis Vascular/efectos adversos , Constricción Patológica , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Alemania , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Estudios Prospectivos , Recurrencia , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
17.
J Endovasc Ther ; 27(6): 936-945, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32873131

RESUMEN

PURPOSE: To report the outcomes after treating stenotic or occluded femoropopliteal lesions with a drug-coated balloon (DCB) followed by the implantation of a thin-strut self-expanding bare metal stent in the BIOLUX 4EVER trial (ClinicalTrials.gov identifier NCT02211664). MATERIALS AND METHODS: The prospective, multicenter, physician-initiated BIOLUX 4-EVER trial was conducted at 5 centers in Belgium and enrolled 120 patients (mean age 70.9±10.5 years; 79 men) with symptomatic stenotic or occluded de novo femoropopliteal lesions. A fifth of the patients had diabetes mellitus and nearly half had previous peripheral artery interventions. The lesions were a mean 83.3±49.5 mm long with a mean reference vessel diameter of 5.26±0.59 mm. Lesions were treated with a Passeo-18 Lux DCB followed by the implantation of a Pulsar-18 bare metal stent. Follow-up visits were conducted at 1, 6, 12, and 24 months postprocedure; the main outcome was primary patency at 12 months. RESULTS: Technical success was obtained in all patients. Primary patency was observed in 89.9% of patients (95% CI 84.0% to 95.8%) at 12 months and in 83.5% at 24 months (95% CI 89.9% to 97.3%), and freedom from target lesion revascularization was 93.6% (95% CI 89.9% to 97.3%) and 86.1% (95% CI 79.9% to 92.3%), respectively. Ten patients died throughout the course of the trial (90.7% survival at 24 months), all of noncardiovascular causes. The ankle-brachial index improved from 0.68±0.09 at baseline to 0.93±0.11 and 0.93±0.12 at 12- and 24-month follow-up visits (p<0.001). An improvement of at least 1 Rutherford category was observed in 91 of 94 patients (96.8%) at 12 months and 78 of 83 patients (93.4%) at 24 months (p<0.001). CONCLUSION: The combination of a Passeo-18 Lux DCB followed by a Pulsar-18 stent implantation produced safe and effective outcomes in the treatment of femoropopliteal lesions at up to 24 months. Adding paclitaxel to the bare nitinol stent platform by predilating with a Passeo-18 Lux DCB seems to increase efficacy at 1 and 2 years compared with the use of bare metal stents only, which were investigated in the precursor 4-EVER study.


Asunto(s)
Angioplastia de Balón , Arteria Femoral/cirugía , Enfermedad Arterial Periférica , Preparaciones Farmacéuticas , Stents , Anciano , Anciano de 80 o más Años , Aleaciones , Angioplastia de Balón/efectos adversos , Bélgica , Materiales Biocompatibles Revestidos , Femenino , Arteria Femoral/patología , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/uso terapéutico , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/cirugía , Arteria Poplítea/diagnóstico por imagen , Estudios Prospectivos , Resultado del Tratamiento , Grado de Desobstrucción Vascular
18.
JACC Cardiovasc Interv ; 13(14): 1709-1715, 2020 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-32703595

RESUMEN

OBJECTIVES: This study sought to evaluate 1-year safety and efficacy of dual-layered mesh-covered carotid stent systems (DLS) for carotid artery stenting (CAS). BACKGROUND: Small clinical studies evaluating 1-year outcomes of CAS performed with 2 available DLS, Roadsaver (RS) (Terumo Corp., Tokyo, Japan) and CGuard (CG) (InspireMD, Boston, Massachusetts), have been published. METHODS: The authors performed an individual patient-level meta-analysis including studies enrolling more than 100 CAS with DLS. The primary endpoint was the death and stroke rate; secondary endpoints were restenosis and in-stent thrombosis rates at 1 year. RESULTS: Patients were divided into 2 groups according to DLS (RS n = 250; CG n = 306). At 1 year, 11 patients died (1.97%), 7 patients in the group RS (2.8%) and 4 patients in the CG one (1.31%); and 10 strokes occurred, 4 in the group RS (1.6%) and 6 in the CG one (1.96%). Overall death and stroke rate was 3.77% (n = 21), 11 events in the group RS group (4.4%) and 10 in the CG group (3.27%). Symptomatic status was the only predictor of death and or stroke. At 1 year, restenosis occurred in 12 patients (2.1%), 10 in the group RS (4%) and 2 in the CG one (0.65%) (p = 0.007). In-stent thrombosis occurred in 1 patient (0.18%) in the CG group (0.32%). RS use was the only independent predictor of restenosis. CONCLUSIONS: This study suggests that DLS use for CAS is associated with a low 1-year death and stroke rate, and the specific DLS stent used could affect the restenosis rate.


Asunto(s)
Angioplastia/instrumentación , Estenosis Carotídea/terapia , Stents , Anciano , Anciano de 80 o más Años , Angioplastia/efectos adversos , Angioplastia/mortalidad , Estenosis Carotídea/complicaciones , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/mortalidad , Bases de Datos Factuales , Femenino , Humanos , Masculino , Diseño de Prótesis , Recurrencia , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
19.
J Cardiovasc Surg (Torino) ; 61(4): 471-477, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32241092

RESUMEN

BACKGROUND: The aim of this study is to investigate the efficacy of the paclitaxel-eluting Legflow balloon catheter in the treatment of "real-world" long and complex femoropopliteal lesions. METHODS: The REFLOW study was a prospective, multi-national, non-randomized, single arm study evaluating the safety and efficacy of the Legflow paclitaxel-eluting balloon dilatation catheter in the treatment of stenotic or occlusive lesions >150 mm long in the femoropopliteal arteries of symptomatic patients (Rutherford 2-5). A total of 120 study subjects were enrolled in a period of 30 months, between October 2015 and May 2018. The mean age was 71.1 years and 79 patients were men (65.8%). Mean lesion length was 216.1 mm. 45.0% of the lesions were occluded, whereas 55.0% were stenotic. Primary endpoint was primary patency at 12 months, defined as absence of a hemodynamically significant stenosis on duplex ultrasound (systolic velocity ratio no greater than 2.4) at the target lesion and without TLR within 12 months. RESULTS: Technical and procedural success (<30.0% residual angiographic stenosis without major complications) was achieved in all 120 cases (100.0%). Primary patency was 84.6% at 6 months and 71.1% at 1 year. Freedom from TLR was 79.9% at 1 year. CONCLUSIONS: If longer term follow-up confirms there is no safety-concern on these paclitaxel device, the excellent results of the newer drug-eluting devices, and the Legflow paclitaxel-eluting balloon in particular, is a valid and effective alternative to treat long and complex "real-world" femoropopliteal lesions.


Asunto(s)
Angioplastia de Balón/instrumentación , Arteriopatías Oclusivas/terapia , Stents Liberadores de Fármacos , Arteria Femoral , Paclitaxel/administración & dosificación , Arteria Poplítea , Adulto , Anciano , Anciano de 80 o más Años , Angiografía , Arteriopatías Oclusivas/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Grado de Desobstrucción Vascular
20.
J Endovasc Ther ; 27(2): 287-295, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31997715

RESUMEN

Purpose: To report the 12-month results of a multicenter, prospective, randomized controlled trial to determine if the ZILVER PTX paclitaxel-eluting stent was noninferior in terms of safety and efficacy compared with surgical bypass. Materials and Methods: This is a study in symptomatic TransAtlantic Inter-Society Consensus (TASC) C and D femoropopliteal lesions comparing endovascular ZILVER PTX stenting vs surgical bypass surgery using a prosthetic graft (ClinicalTrials.gov identifier NCT01952457). Between October 2013 and July 2017, 220 patients (mean age 68.6±10.5 years; 159 men) were enrolled and randomized to the ZILVER PTX treatment group (113, 51.4%) or the bypass treatment group (107, 48.6%). Most of the lesions were occlusions (208, 94.5%); the mean lesion length was 247.1±69.3 mm. The primary outcome measure was primary patency at 12 months, defined as no evidence of binary restenosis or occlusion within the target lesion or bypass graft based on a duplex-derived peak systolic velocity ratio <2.4 and no clinically-driven target lesion revascularization (TLR) in endovascular cases or reintervention to restore flow in the bypass. Results: The estimated 12-month primary patency rate was 74.5% (95% CI 66.3% to 82.7%) for the ZILVER PTX group vs 72.5% (95% CI 63.7% to 81.3%) for the bypass arm (p=0.998). Freedom from TLR at 12 months was 80.9% (95% CI 73.3% to 88.5%) for the ZILVER PTX group vs 76.2% (95% CI 68.0% to 84.4%) for the bypass group (p=0.471). The 30-day complication rate was significantly lower in the ZILVER PTX group (4.4% vs 11.3%, p=0.004). Also, procedure time and hospital stay were significantly shorter in the ZILVER PTX group (p<0.001 for both). Conclusion: With noninferior patency results, a lower complication rate, and shorter procedures and hospital stays, paclitaxel-eluting stenting might become a recommended treatment for long TASC C and D femoropopliteal lesions.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Stents Liberadores de Fármacos , Procedimientos Endovasculares/instrumentación , Arteria Femoral/cirugía , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/terapia , Arteria Poplítea/cirugía , Anciano , Anciano de 80 o más Años , Implantación de Prótesis Vascular/efectos adversos , Brasil , Fármacos Cardiovasculares/uso terapéutico , Procedimientos Endovasculares/efectos adversos , Europa (Continente) , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Estudios Prospectivos , Diseño de Prótesis , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...