Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS One ; 19(5): e0301624, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38713678

RESUMEN

Salmonella enterica serovar Typhi (S. Typhi) is the causative agent of Typhoid fever. Blood culture is the gold standard for clinical diagnosis, but this is often difficult to employ in resource limited settings. Environmental surveillance of waste-impacted waters is a promising supplement to clinical surveillance, however validating methods is challenging in regions where S. Typhi concentrations are low. To evaluate existing S. Typhi environmental surveillance methods, a novel process control organism (PCO) was created as a biosafe surrogate. Using a previous described qPCR assay, a modified PCR amplicon for the staG gene was cloned into E. coli. We developed a target region that was recognized by the Typhoid primers in addition to a non-coding internal probe sequence. A multiplex qPCR reaction was developed that differentiates between the typhoid and control targets, with no cross-reactivity or inhibition of the two probes. The PCO was shown to mimic S. Typhi in lab-based experiments with concentration methods using primary wastewater: filter cartridge, recirculating Moore swabs, membrane filtration, and differential centrifugation. Across all methods, the PCO seeded at 10 CFU/mL and 100 CFU/mL was detected in 100% of replicates. The PCO is detected at similar quantification cycle (Cq) values across all methods at 10 CFU/mL (Average = 32.4, STDEV = 1.62). The PCO was also seeded into wastewater at collection sites in Vellore (India) and Blantyre (Malawi) where S. Typhi is endemic. All methods tested in both countries were positive for the seeded PCO. The PCO is an effective way to validate performance of environmental surveillance methods targeting S. Typhi in surface water.


Asunto(s)
Monitoreo del Ambiente , Escherichia coli , Salmonella typhi , Salmonella typhi/genética , Salmonella typhi/aislamiento & purificación , Escherichia coli/genética , Escherichia coli/aislamiento & purificación , Monitoreo del Ambiente/métodos , Aguas Residuales/microbiología , Fiebre Tifoidea/microbiología , Fiebre Tifoidea/epidemiología , Fiebre Tifoidea/diagnóstico , Fiebre Tifoidea/prevención & control , Humanos , Microbiología del Agua
2.
Am J Trop Med Hyg ; 108(3): 482-491, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36746655

RESUMEN

Salmonella enterica serovar (Salmonella Typhi) is the causative bacterial agent of typhoid fever. Environmental surveillance of wastewater and wastewater-impacted surface waters has proven effective in monitoring various pathogens and has recently been applied to Salmonella Typhi. This study evaluated eight sample collection and concentration methods with 12 variations currently being developed and used for Salmonella Typhi surveillance globally to better understand the performance of each method based on its ability to detect Salmonella Typhi and its feasibility. Salmonella Typhi strains Ty21a and Ty2 were seeded to influent wastewater at known concentrations to evaluate the following methods: grab sampling using electropositive filters, centrifugation, direct enrichment, or membrane filtration and trap sampling using Moore swabs. Concentrated samples underwent nucleic acid extraction and were detected and/or quantified via quantitative polymerase chain reaction (qPCR). Results suggest that all methods tested can be successful at concentrating Salmonella Typhi for subsequent detection by qPCR, although each method has its own strengths and weaknesses, including the Salmonella Typhi concentration it is best suited for, with a range of positive detections observed as low as 0.1-0.001 colony-forming units (CFU) Ty21a/mL and 0.01 CFU Ty2/mL. These factors should be considered when identifying a method for environmental surveillance and will greatly depend on the use case planned.


Asunto(s)
Salmonella enterica , Fiebre Tifoidea , Humanos , Salmonella typhi , Aguas Residuales , Fiebre Tifoidea/microbiología
3.
Sci Total Environ ; 760: 144215, 2021 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-33340739

RESUMEN

Wastewater1 surveillance of SARS-CoV-2 may be a useful supplement to clinical surveillance as it is shed in feces, there are many asymptomatic cases, and diagnostic testing can have capacity limitations and extended time to results. Although numerous studies have utilized wastewater surveillance for SARS-CoV-2, the methods used were developed and/or standardized for other pathogens. This study evaluates multiple methods for concentration and recovery of SARS-CoV-2 and seeded human coronavirus OC43 from municipal primary wastewater and/or sludge from the Greater Seattle Area (March-July 2020). Methods evaluated include the bag-mediated filtration system (BMFS), with and without Vertrel™ extraction, skimmed milk flocculation, with and without Vertrel™ extraction, polyethylene glycol (PEG) precipitation, ultrafiltration, and sludge extraction. Total RNA was extracted from wastewater concentrates and analyzed for SARS-CoV-2 and OC43 with RT-qPCR. Skimmed milk flocculation without Vertrel™ extraction performed consistently over time and between treatment plants in Seattle-area wastewater with the lowest average OC43 Cq value and smallest variability (24.3; 95% CI: 23.8-24.9), most frequent SARS-CoV-2 detection (48.8% of sampling events), and highest average OC43 percent recovery (9.1%; 95% CI: 6.2-11.9%). Skimmed milk flocculation is also beneficial because it is feasible in low-resource settings. While the BMFS had the highest average volume assayed of 11.9 mL (95% CI: 10.7-13.1 mL), the average OC43 percent recovery was low (0.7%; 95% CI: 0.4-1.0%). Ultrafiltration and PEG precipitation had low average OC43 percent recoveries of 1.0% (95% CI: 0.5-1.6%) and 3.2% (95% CI: 1.3-5.1%), respectively. The slopes and efficiency for the SARS-CoV-2 standard curves were not consistent over time, confirming the need to include a standard curve each run rather than using a single curve for multiple plates. Results suggest that the concentration and detection methods used must be validated for the specific water matrix using a recovery control to assess performance over time.


Asunto(s)
COVID-19 , Aguas Residuales , Monitoreo del Ambiente , Humanos , SARS-CoV-2 , Aguas del Alcantarillado
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...