Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 51
1.
Int J Pediatr Otorhinolaryngol ; 176: 111820, 2024 Jan.
Article En | MEDLINE | ID: mdl-38103308

INTRODUCTION: Paediatric otorrhoea (PO) describes a middle ear infection that results in a perforation of the tympanic membrane and ear discharge, in children and young people (CYP). Prolonged infection may be associated with hearing loss and developmental delay. The current management of paediatric otorrhoea is variable, including non-invasive treatments (conservative, oral antibiotics, topical antibiotics) and surgery, reflecting the lack of a sufficiently strong evidence base. Outcome reporting is fundamental to producing reliable and meaningful evidence to inform best practice. OBJECTIVES: Primary objective: to determine which outcome measures are currently used to evaluate treatment success in studies of non-surgical treatments for paediatric otorrhoea. SECONDARY OBJECTIVES: to identify outcome measurement instruments used in the literature and assess their applicability for use in clinical trials of PO. METHODS: This systematic review was registered with PROSPERO (CRD42023407976). Database searches of EMBASE, MEDLINE and Cochrane was performed on June 6, 2023, covering from Jan 1995 to May 2023. Randomised controlled trials or study protocols involving CYP with PO were included following PRISMA guidelines. Risk of bias was assessed with Cochrane's tool. RESULTS: Of the 377 papers identified, six were included in the systematic review. The primary outcome of five of the studies related to otorrhoea cessation; both time to cessation and proportion recovered at various time points were used as measures. Two measurement instruments were identified: Otitis Media-6 Questionnaire and the Institute for Medical Technology Assessment Productivity Cost Questionnaire. Both were shown to be applicable measurement instruments when used in clinical trials of PO. CONCLUSIONS: To promote homogeneity and facilitate meaningful comparison and combination of studies, we propose that time to cessation of otorrhoea from onset of otorrhoea should be used as the primary outcome in future studies. Further research is needed to establish if this is the most important outcome to children and their caregivers.


Deafness , Ear Diseases , Otitis Media , Child , Humans , Adolescent , Otitis Media/drug therapy , Anti-Bacterial Agents/therapeutic use , Ear Diseases/drug therapy , Treatment Outcome
2.
BMJ Open ; 13(9): e078052, 2023 09 05.
Article En | MEDLINE | ID: mdl-37669838

INTRODUCTION: Paediatric otorrhoea (PO) refers to the leakage of fluid through a perforation in the ear drum, resulting from an infection of the middle ear of a child or young person (CYP). PO frequently results in hearing loss which may lead to developmental delay, restricted communication and reduced educational attainment.Epidemiological information for PO is largely derived from low-income countries. The aim of this study will be to establish the incidence of PO within the UK and to understand the impact of PO on CYP and their families' everyday lives. It will build the foundations for a randomised controlled trial investigating the best antibiotic treatment for PO. METHODS AND ANALYSIS: The study will consist of two work packages. (1) Data from the Clinical Practice Research Datalink (CPRD), January 2005 to July 2021, will be used to determine the incidence of patient presentations with PO to primary care in the UK. It will also explore the current antimicrobial prescribing practice for PO in primary care. (2) Thirty semi-structured interviews will be conducted from 13 July to 31 October 2023 with CYP and their parents/carers to help identify the impact of PO on everyday life, the patient journey and how service users define treatment success. Three medical professional focus groups will be used to understand the current management practice, how treatment success is measured and acceptability to randomise patients. Thematic analysis will be used. ETHICS AND DISSEMINATION: The Health Research Authority, The Health and Social Care Research Ethics Committee (23/NI/0082) and the CPRD's research data governance panel (22_002508) reviewed this study. Results will be disseminated at medical conferences, in peer-reviewed journals and via social media. The study will cocreate a webpage on healthtalk.org, with the Dipex Charity, about PO to ensure members of the public can learn more about the condition. TRIAL REGISTRATION NUMBER: ISRCTN46071200.


Academic Success , Deafness , Humans , Child , Adolescent , Charities , Communication , United Kingdom , Randomized Controlled Trials as Topic
3.
Med Phys ; 43(8): 4700, 2016 Aug.
Article En | MEDLINE | ID: mdl-27487887

PURPOSE: For the first time, MRI-guided radiation therapy systems can acquire cine images to dynamically monitor in-treatment internal organ motion. However, the complex head and neck (H&N) structures and low-contrast/resolution of on-board cine MRI images make automatic motion tracking a very challenging task. In this study, the authors proposed an integrated model-driven method to automatically track the in-treatment motion of the H&N upper airway, a complex and highly deformable region wherein internal motion often occurs in an either voluntary or involuntary manner, from cine MRI images for the analysis of H&N motion patterns. METHODS: Considering the complex H&N structures and ensuring automatic and robust upper airway motion tracking, the authors firstly built a set of linked statistical shapes (including face, face-jaw, and face-jaw-palate) using principal component analysis from clinically approved contours delineated on a set of training data. The linked statistical shapes integrate explicit landmarks and implicit shape representation. Then, a hierarchical model-fitting algorithm was developed to align the linked shapes on the first image frame of a to-be-tracked cine sequence and to localize the upper airway region. Finally, a multifeature level set contour propagation scheme was performed to identify the upper airway shape change, frame-by-frame, on the entire image sequence. The multifeature fitting energy, including the information of intensity variations, edge saliency, curve geometry, and temporal shape continuity, was minimized to capture the details of moving airway boundaries. Sagittal cine MR image sequences acquired from three H&N cancer patients were utilized to demonstrate the performance of the proposed motion tracking method. RESULTS: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 50 randomly selected cine image frames from each patient. The resulting average dice similarity coefficient (93.28% ± 1.46%) and margin error (0.49 ± 0.12 mm) showed good agreement between the automatic and manual results. The comparison with three other deformable model-based segmentation methods illustrated the superior shape tracking performance of the proposed method. Large interpatient variations of swallowing frequency, swallowing duration, and upper airway cross-sectional area were observed from the testing cine image sequences. CONCLUSIONS: The proposed motion tracking method can provide accurate upper airway motion tracking results, and enable automatic and quantitative identification and analysis of in-treatment H&N upper airway motion. By integrating explicit and implicit linked-shape representations within a hierarchical model-fitting process, the proposed tracking method can process complex H&N structures and low-contrast/resolution cine MRI images. Future research will focus on the improvement of method reliability, patient motion pattern analysis for providing more information on patient-specific prediction of structure displacements, and motion effects on dosimetry for better H&N motion management in radiation therapy.


Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/radiotherapy , Magnetic Resonance Imaging, Cine , Models, Biological , Movement , Radiotherapy, Image-Guided/methods , Respiratory System/physiopathology , Female , Head and Neck Neoplasms/physiopathology , Humans , Male , Respiration , Respiratory System/diagnostic imaging
4.
Med Phys ; 42(10): 5828-37, 2015 Oct.
Article En | MEDLINE | ID: mdl-26429257

PURPOSE: To characterize the performance of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy (MR-IGRT) system. METHODS: The imaging performance characterization included four components: ACR (the American College of Radiology) phantom test, spatial integrity, coil signal to noise ratio (SNR) and uniformity, and magnetic field homogeneity. The ACR phantom test was performed in accordance with the ACR phantom test guidance. The spatial integrity test was evaluated using a 40.8 × 40.8 × 40.8 cm(3) spatial integrity phantom. MR and computed tomography (CT) images of the phantom were acquired and coregistered. Objects were identified around the surfaces of 20 and 35 cm diameters of spherical volume (DSVs) on both the MR and CT images. Geometric distortion was quantified using deviation in object location between the MR and CT images. The coil SNR test was performed according to the national electrical manufacturers association (NEMA) standards MS-1 and MS-9. The magnetic field homogeneity test was measured using field camera and spectral peak methods. RESULTS: For the ACR tests, the slice position error was less than 0.10 cm, the slice thickness error was less than 0.05 cm, the resolved high-contrast spatial resolution was 0.09 cm, the resolved low-contrast spokes were more than 25, the image intensity uniformity was above 93%, and the percentage ghosting was less than 0.22%. All were within the ACR recommended specifications. The maximum geometric distortions within the 20 and 35 cm DSVs were 0.10 and 0.18 cm for high spatial resolution three-dimensional images and 0.08 and 0.20 cm for high temporal resolution two dimensional cine images based on the distance-to-phantom-center method. The average SNR was 12.0 for the body coil, 42.9 for the combined torso coil, and 44.0 for the combined head and neck coil. Magnetic field homogeneities at gantry angles of 0°, 30°, 60°, 90°, and 120° were 23.55, 20.43, 18.76, 19.11, and 22.22 ppm, respectively, using the field camera method over the 45 cm DSV. CONCLUSIONS: The onboard imaging unit of the first commercial MR-IGRT system meets ACR, NEMA, and vendor specifications.


Magnetic Resonance Imaging/methods , Radiotherapy, Image-Guided/methods , Humans , Magnetic Fields , Phantoms, Imaging , Quality Control , Signal-To-Noise Ratio
5.
J Appl Clin Med Phys ; 15(3): 4434, 2014 May 08.
Article En | MEDLINE | ID: mdl-24892328

The purpose of this study is to investigate changes in lung tumor internal target volume during stereotactic body radiotherapy treatment (SBRT) using magnetic resonance imaging (MRI). Ten lung cancer patients (13 tumors) undergoing SBRT (48 Gy over four consecutive days) were evaluated. Each patient underwent three lung MRI evaluations: before SBRT (MRI-1), after fraction 3 of SBRT (MRI-3), and three months after completion of SBRT (MRI-3m). Each MRI consisted of T1-weighted images in axial plane through the entire lung. A cone-beam CT (CBCT) was taken before each fraction. On MRI and CBCT taken before fractions 1 and 3, gross tumor volume (GTV) was contoured and differences between the two volumes were compared. Median tumor size on CBCT before fractions1 (CBCT-1) and 3 (CBCT-3) was 8.68 and 11.10 cm3, respectively. In 12 tumors, the GTV was larger on CBCT-3 compared to CBCT-1 (median enlargement, 1.56 cm3). Median tumor size on MRI-1, MRI-3, and MRI-3m was 7.91, 11.60, and 3.33 cm3, respectively. In all patients, the GTV was larger on MRI-3 compared to MRI-1 (median enlargement, 1.54 cm3). In all patients, GTV was smaller on MRI-3m compared to MRI-1 (median shrinkage, 5.44 cm3). On CBCT and MRI, all patients showed enlargement of the GTV during the treatment week of SBRT, except for one patient who showed minimal shrinkage (0.86 cm3). Changes in tumor volume are unpredictable; therefore, motion and breathing must be taken into account during treatment planning, and image-guided methods should be used, when treating with large fraction sizes.


Artifacts , Lung Neoplasms/pathology , Lung Neoplasms/radiotherapy , Magnetic Resonance Imaging/methods , Radiosurgery/methods , Radiotherapy, Image-Guided/methods , Tumor Burden , Female , Humans , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Lung Neoplasms/physiopathology , Male , Middle Aged , Motion , Reproducibility of Results , Respiratory Mechanics , Sensitivity and Specificity , Subtraction Technique
6.
Semin Radiat Oncol ; 24(3): 196-9, 2014 Jul.
Article En | MEDLINE | ID: mdl-24931092

A description of the first commercially available magnetic resonance imaging (MRI)-guided radiation therapy (RT) system is provided. The system consists of a split 0.35-T MR scanner straddling 3 (60)Co heads mounted on a ring gantry, each head equipped with independent doubly focused multileaf collimators. The MR and RT systems share a common isocenter, enabling simultaneous and continuous MRI during RT delivery. An on-couch adaptive RT treatment-planning system and integrated MRI-guided RT control system allow for rapid adaptive planning and beam delivery control based on the visualization of soft tissues. Treatment of patients with this system commenced at Washington University in January 2014.


Magnetic Resonance Imaging/instrumentation , Radiation Oncology/instrumentation , Radiotherapy, Image-Guided/instrumentation , Equipment Design , Humans , Magnetic Resonance Imaging, Interventional , Missouri , Radiotherapy Planning, Computer-Assisted/instrumentation
7.
Am J Clin Oncol ; 35(2): 110-4, 2012 Apr.
Article En | MEDLINE | ID: mdl-21383608

OBJECTIVE: Using 5-bulk-density heterogeneous dose calculation, we investigated whether contrast-enhanced (CE+) computed tomography (CT) will affect dose-calculation accuracy in the thoracic area. METHODS: We analyzed 17 radiation-oncology patients who underwent thoracic CE+ CTs. Full-resolution CT and 5-bulk-density plans were generated using an adaptive convolution algorithm. Bulk densities for air, lung, fat, soft tissue, and bone were applied to regions identified by an isodensity segmentation tool. The population-averaged physical density of each region was calculated and compared with the reference value calculated from 66 noncontrast-enhanced (CE-) thoracic CT images. Using the 5-bulk densities, we created a new plan in which the physical densities of each area were forced to be the same as the CE- reference value, and we compared the dose-volume histograms (DVH). RESULTS: Average physical density for the segmented air, lung, fat, soft tissue, and bone for CE+ were 0.14, 0.29, 0.90, 1.03, and 1.13 g/cm(3), and the reference values for CE- were 0.14, 0.26, 0.89, 1.02, and 1.12 g/cm(3), respectively. In all the cases, the normal-tissue DVH agreed to better than 1%. In 15 cases, DVH of the planning target volume (PTV) agreed to better than 3%. In 2 patients, >3% difference in the PTV dose was observed. CONCLUSIONS: Only 2 patients with a strong injection artifact in the PTV or beam showed >3% discrepancy in the target dose. When using CE+ CT for treatment planning, strong injection artifacts must be excluded.


Artifacts , Contrast Media , Esophageal Neoplasms/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Radiography, Thoracic , Radiotherapy Planning, Computer-Assisted , Tomography, X-Ray Computed , Adult , Aged , Esophageal Neoplasms/radiotherapy , Female , Humans , Lung Neoplasms/radiotherapy , Male , Middle Aged , Radiography, Thoracic/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed/methods
8.
Med Phys ; 38(3): 1313-38, 2011 Mar.
Article En | MEDLINE | ID: mdl-21520843

Intensity modulated radiation therapy (IMRT) poses a number of challenges for properly measuring commissioning data and quality assurance (QA) radiation dose distributions. This report provides a comprehensive overview of how dosimeters, phantoms, and dose distribution analysis techniques should be used to support the commissioning and quality assurance requirements of an IMRT program. The proper applications of each dosimeter are described along with the limitations of each system. Point detectors, arrays, film, and electronic portal imagers are discussed with respect to their proper use, along with potential applications of 3D dosimetry. Regardless of the IMRT technique utilized, some situations require the use of multiple detectors for the acquisition of accurate commissioning data. The overall goal of this task group report is to provide a document that aids the physicist in the proper selection and use of the dosimetry tools available for IMRT QA and to provide a resource for physicists that describes dosimetry measurement techniques for purposes of IMRT commissioning and measurement-based characterization or verification of IMRT treatment plans. This report is not intended to provide a comprehensive review of commissioning and QA procedures for IMRT. Instead, this report focuses on the aspects of metrology, particularly the practical aspects of measurements that are unique to IMRT. The metrology of IMRT concerns the application of measurement instruments and their suitability, calibration, and quality control of measurements. Each of the dosimetry measurement tools has limitations that need to be considered when incorporating them into a commissioning process or a comprehensive QA program. For example, routine quality assurance procedures require the use of robust field dosimetry systems. These often exhibit limitations with respect to spatial resolution or energy response and need to themselves be commissioned against more established dosimeters. A chain of dosimeters, from secondary standards to field instruments, is established to assure the quantitative nature of the tests. This report is intended to describe the characteristics of the components of these systems; dosimeters, phantoms, and dose evaluation algorithms. This work is the report of AAPM Task Group 120.


Radiometry/methods , Radiotherapy, Intensity-Modulated/methods , Humans , Phantoms, Imaging , Quality Control , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/instrumentation , Radiotherapy, Intensity-Modulated/standards
9.
Phys Med Biol ; 55(18): 5467-82, 2010 Sep 21.
Article En | MEDLINE | ID: mdl-20798458

One of the most widely studied problems of the intensity-modulated radiation therapy (IMRT) treatment planning problem is the fluence map optimization (FMO) problem, the problem of determining the amount of radiation intensity, or fluence, of each beamlet in each beam. For a given set of beams, the fluences of the beamlets can drastically affect the quality of the treatment plan, and thus it is critical to obtain good fluence maps for radiation delivery. Although several approaches have been shown to yield good solutions to the FMO problem, these solutions are not guaranteed to be optimal. This shortcoming can be attributed to either optimization model complexity or properties of the algorithms used to solve the optimization model. We present a convex FMO formulation and an interior point algorithm that yields an optimal treatment plan in seconds, making it a viable option for clinical applications.


Algorithms , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Humans , Radiotherapy Dosage
10.
Med Phys ; 37(2): 477-84, 2010 Feb.
Article En | MEDLINE | ID: mdl-20229856

PURPOSE: Accurate modeling of beam profiles is important for precise treatment planning dosimetry. Calculated beam profiles need to precisely replicate profiles measured during machine commissioning. Finite detector size introduces perturbations into the measured profiles, which, in turn, impact the resulting modeled profiles. The authors investigate a method for extracting the unperturbed beam profiles from those measured during linear accelerator commissioning. METHODS: In-plane and cross-plane data were collected for an Elekta Synergy linac at 6 MV using ionization chambers of volume 0.01, 0.04, 0.13, and 0.65 cm3 and a diode of surface area 0.64 mm2. The detectors were orientated with the stem perpendicular to the beam and pointing away from the gantry. Profiles were measured for a 10 x 10 cm2 field at depths ranging from 0.8 to 25.0 cm and SSDs from 90 to 110 cm. Shaping parameters of a Gaussian response function were obtained relative to the Edge detector. The Gaussian function was deconvolved from the measured ionization chamber data. The Edge detector profile was taken as an approximation to the true profile, to which deconvolved data were compared. Data were also collected with CC13 and Edge detectors for additional fields and energies on an Elekta Synergy, Varian Trilogy, and Siemens Oncor linear accelerator and response functions obtained. Response functions were compared as a function of depth, SSD, and detector scan direction. Variations in the shaping parameter were introduced and the effect on the resulting deconvolution profiles assessed. RESULTS: Up to 10% setup dependence in the Gaussian shaping parameter occurred, for each detector for a particular plane. This translated to less than a +/- 0.7 mm variation in the 80%-20% penumbral width. For large volume ionization chambers such as the FC65 Farmer type, where the cavity length to diameter ratio is far from 1, the scan direction produced up to a 40% difference in the shaping parameter between in-plane and cross-plane measurements. This is primarily due to the directional difference in penumbral width measured by the FC65 chamber, which can more than double in profiles obtained with the detector stem parallel compared to perpendicular to the scan direction. For the more symmetric CC13 chamber the variation was only 3% between in-plane and cross-plane measurements. CONCLUSIONS: The authors have shown that the detector response varies with detector type, depth, SSD, and detector scan direction. In-plane vs. cross-plane scanning can require calculation of a direction dependent response function. The effect of a 10% overall variation in the response function, for an ionization chamber, translates to a small deviation in the penumbra from that of the Edge detector measured profile when deconvolved. Due to the uncertainties introduced by deconvolution the Edge detector would be preferable in obtaining an approximation of the true profile, particularly for field sizes where the energy dependence of the diode can be neglected. However, an averaged response function could be utilized to provide a good approximation of the true profile for large ionization chambers and for larger fields for which diode detectors are not recommended.


Particle Accelerators/instrumentation , Radiometry/instrumentation , Radiotherapy, High-Energy/instrumentation , Computer Simulation , Computer-Aided Design , Dose-Response Relationship, Radiation , Equipment Design , Equipment Failure Analysis , Models, Theoretical , Radiation Dosage , Reproducibility of Results , Scattering, Radiation , Sensitivity and Specificity
11.
J Appl Clin Med Phys ; 10(2): 92-103, 2009 Apr 30.
Article En | MEDLINE | ID: mdl-19458588

The aim of this study was to investigate the relative accuracy of megavoltage photon-beam dose calculations employing either 5 bulk densities or independent voxel densities determined by calibration of the CT Houndsfield number. Full-resolution CT and bulk density treatment plans were generated for 70 lung or esophageal cancer tumors (66 cases) using a commercial treatment planning system with an adaptive convolution dose calculation algorithm (Pinnacle3, Philips Medicals Systems). Bulk densities were applied to segmented regions. Individual and population average densities were compared to the full-resolution plan for each case. Monitor units were kept constant and no normalizations were employed. Dose volume histograms (DVH) and dose difference distributions were examined for all cases. The average densities of the segmented air, lung, fat, soft tissue, and bone for the entire set were found to be 0.14, 0.26, 0.89, 1.02, and 1.12 g/cc, respectively. In all cases, the normal tissue DVH agreed to better than 2% in dose. In 62 of 70 target DVHs, agreement to better than 3% in dose was observed. Six cases demonstrated emphysema, one with bullous formations and one with a hiatus hernia having a large volume of gas. They required the additional assignment of density to the emphysemic lung and inflammatory changes to the lung, the regions of collapsed lung, the bullous formations, and the hernia gas. Bulk tissue density dose calculation provides an accurate method of heterogeneous dose calculation. However, patients with advanced emphysema may require high-resolution CT studies for accurate treatment planning.


Dose-Response Relationship, Radiation , Lung Neoplasms/radiotherapy , Adolescent , Adult , Aged , Aged, 80 and over , Esophageal Neoplasms/radiotherapy , Female , Humans , Male , Middle Aged , Radiotherapy Planning, Computer-Assisted , Tomography, X-Ray Computed
12.
Health Aff (Millwood) ; 28(2): 416-27, 2009.
Article En | MEDLINE | ID: mdl-19275998

Building privacy and security protections into health information technology systems will bolster trust in such systems and promote their adoption. The privacy issue, too long seen as a barrier to electronic health information exchange, can be resolved through a comprehensive framework that implements core privacy principles, adopts trusted network design characteristics, and establishes oversight and accountability mechanisms. The public policy challenges of implementing this framework in a complex and evolving environment will require improvements to existing law, new rules for entities outside the traditional health care sector, a more nuanced approach to the role of consent, and stronger enforcement mechanisms.


Confidentiality/legislation & jurisprudence , Electronic Health Records/legislation & jurisprudence , Health Insurance Portability and Accountability Act , Health Records, Personal , Humans , Information Dissemination/legislation & jurisprudence , Privacy/legislation & jurisprudence , United States
13.
J Am Acad Audiol ; 19(1): 5-17, 2008 Jan.
Article En | MEDLINE | ID: mdl-18637406

This study compared the performance of bilingual participants on the English and Spanish versions of the Hearing in Noise Test (HINT). The participants were divided into an early bilingual (EB) group and a late bilingual (LB) group based on age of second-language acquisition. All participants acquired Spanish as their first language (L1) and English as a second language (L2). Care was taken to ensure that all participants demonstrated at least a "good competence level" for self-rated speaking, understanding, reading, and writing skills in both English and Spanish. Results revealed superior performance on the Spanish HINT versus the English HINT in both quiet and in noise for both groups of participants. Significant differences in performance were noted for the EB versus the LB participants. A number of possible explanations for superior performance in L1 are provided, and implications for educating students in their L2 are discussed.


Language Tests , Multilingualism , Speech Perception/physiology , Verbal Learning/physiology , Adolescent , Adult , Age Factors , Child , Female , Hearing , Humans , Male , Noise , Regression Analysis , Students
14.
Phys Med Biol ; 53(12): 3175-88, 2008 Jun 21.
Article En | MEDLINE | ID: mdl-18506074

In this study, we perform a scientific comparative analysis of using (60)Co beams in intensity-modulated radiation therapy (IMRT). In particular, we evaluate the treatment plan quality obtained with (i) 6 MV, 18 MV and (60)Co IMRT; (ii) different numbers of static multileaf collimator (MLC) delivered (60)Co beams and (iii) a helical tomotherapy (60)Co beam geometry. We employ a convex fluence map optimization (FMO) model, which allows for the comparison of plan quality between different beam energies and configurations for a given case. A total of 25 clinical patient cases that each contain volumetric CT studies, primary and secondary delineated targets, and contoured structures were studied: 5 head-and-neck (H&N), 5 prostate, 5 central nervous system (CNS), 5 breast and 5 lung cases. The DICOM plan data were anonymized and exported to the University of Florida optimized radiation therapy (UFORT) treatment planning system. The FMO problem was solved for each case for 5-71 equidistant beams as well as a helical geometry for H&N, prostate, CNS and lung cases, and for 3-7 equidistant beams in the upper hemisphere for breast cases, all with 6 MV, 18 MV and (60)Co dose models. In all cases, 95% of the target volumes received at least the prescribed dose with clinical sparing criteria for critical organs being met for all structures that were not wholly or partially contained within the target volume. Improvements in critical organ sparing were found with an increasing number of equidistant (60)Co beams, yet were marginal above 9 beams for H&N, prostate, CNS and lung. Breast cases produced similar plans for 3-7 beams. A helical (60)Co beam geometry achieved similar plan quality as static plans with 11 equidistant (60)Co beams. Furthermore, 18 MV plans were initially found not to provide the same target coverage as 6 MV and (60)Co plans; however, adjusting the trade-offs in the optimization model allowed equivalent target coverage for 18 MV. For plans with comparable target coverage, critical structure sparing was best achieved with 6 MV beams followed closely by (60)Co beams, with 18 MV beams requiring significantly increased dose to critical structures. In this paper, we report in detail on a representative set of results from these experiments. The results of the investigation demonstrate the potential for IMRT radiotherapy employing commercially available (60)Co sources and a double-focused MLC. Increasing the number of equidistant beams beyond 9 was not observed to significantly improve target coverage or critical organ sparing and static plans were found to produce comparable plans to those obtained using a helical tomotherapy treatment delivery when optimized using the same well-tuned convex FMO model. While previous studies have shown that 18 MV plans are equivalent to 6 MV for prostate IMRT, we found that the 18 MV beams actually required more fluence to provide similar quality target coverage.


Cobalt Radioisotopes/therapeutic use , Radiotherapy, Intensity-Modulated/methods , Breast Neoplasms/radiotherapy , Central Nervous System/pathology , Central Nervous System/radiation effects , Head and Neck Neoplasms/radiotherapy , Humans , Male , Prostatic Neoplasms/radiotherapy , Radiotherapy, High-Energy
15.
Med Phys ; 35(2): 473-9, 2008 Feb.
Article En | MEDLINE | ID: mdl-18383667

We have developed a high resolution, quantitative, two-dimensional optical film scanner for use with a commercial high sensitivity radiochromic film (RCF) for measuring single fraction external-beam radiotherapy dose distributions. The film scanner was designed to eliminate artifacts commonly observed in RCF dosimetry. The scanner employed a stationary light source and detector with a moving antireflective glass film platen attached to a high precision computerized X-Y translation stage. An ultrabright red light emitting diode (LED) with a peak output at 633 nm and full width at half maximum (FWHM) of 16 nm was selected as the scanner light source to match the RCF absorption peak. A dual detector system was created using two silicon photodiode detectors to simultaneously measure incident and transmitted light. The LED light output was focused to a submillimeter (FWHM 0.67 mm) spot size, which was determined from a scanning knife-edge technique for measuring Gaussian optical beams. Data acquisition was performed with a 16-bit A/D card in conjunction with commercial software. The linearity of the measured densities on the scanner was tested using a calibrated neutral-density step filter. Sensitometric curves and three IMRT field scans were acquired with a spatial resolution of 1 mm for both radiographic film and RCF. The results were compared with measurements taken with a commercial diode array under identical delivery conditions. The RCF was rotated by 90 deg and rescanned to study orientation effects. Comparison between the RCF and the diode array measurements using percent dose difference and distance-to-agreement criteria produced average passing rates of 99.0% using 3%/3 mm criteria and 96.7% using 2%/2 mm criteria. The same comparison between the radiographic film and diode array measurements resulted in average passing rates 96.6% and 91.6% for the above two criteria, respectively. No measurable light-scatter or interference scanner artifacts were observed. The RCF rotated by 90 deg showed no measurable orientation effect. A scan of a 15 x 15 cm2 area with 1 mm resolution required 22 min to acquire. The LED densitometer provides an accurate film dosimetry system with 1 mm or better resolution. The scanner eliminates the orientation dependence of RCF dosimetry that was previously reported with commercial flatbed scanners.


Computer Peripherals , Film Dosimetry/instrumentation , Lighting/instrumentation , Photometry/instrumentation , Equipment Design , Equipment Failure Analysis , Film Dosimetry/methods , Photometry/methods , Pilot Projects , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity
16.
Med Phys ; 35(3): 1103-12, 2008 Mar.
Article En | MEDLINE | ID: mdl-18404945

The authors present a comparative study of intensity modulated proton therapy (IMPT) treatment planning employing algorithms of three-dimensional (3D) modulation, and 2.5-dimensional (2.5D) modulation, and intensity modulated distal edge tracking (DET) [A. Lomax, Phys. Med. Biol. 44, 185-205 (1999)] applied to the treatment of head-and-neck cancer radiotherapy. These three approaches were also compared with 6 MV photon intensity modulated radiation therapy (IMRT). All algorithms were implemented in the University of Florida Optimized Radiation Therapy system using a finite sized pencil beam dose model and a convex fluence map optimization model. The 3D IMPT and the DET algorithms showed considerable advantages over the photon IMRT in terms of dose conformity and sparing of organs at risk when the beam number was not constrained. The 2.5D algorithm did not show an advantage over the photon IMRT except in the dose reduction to the distant healthy tissues, which is inherent in proton beam delivery. The influences of proton beam number and pencil beam size on the IMPT plan quality were also studied. Out of 24 cases studied, three cases could be adequately planned with one beam and 12 cases could be adequately planned with two beams, but the dose uniformity was often marginally acceptable. Adding one or two more beams in each case dramatically improved the dose uniformity. The finite pencil beam size had more influence on the plan quality of the 2.5D and DET algorithms than that of the 3D IMPT. To obtain a satisfactory plan quality, a 0.5 cm pencil beam size was required for the 3D IMPT and a 0.3 cm size was required for the 2.5D and the DET algorithms. Delivery of the IMPT plans produced in this study would require a proton beam spot scanning technique that has yet to be developed clinically.


Algorithms , Proton Therapy , Radiotherapy, Intensity-Modulated/methods , Head/radiation effects , Humans , Neck/radiation effects , Radiotherapy Planning, Computer-Assisted
17.
Int J Radiat Oncol Biol Phys ; 71(3): 880-9, 2008 Jul 01.
Article En | MEDLINE | ID: mdl-18440728

PURPOSE: To propose a new measure of target underdose that can be used in the evaluation and optimization of radiotherapy dose distributions. METHODS AND MATERIALS: We compare various formulations of the equivalent uniform dose (EUD) and introduce a modification of existing EUD definitions, which we call tail EUD. Tail EUD is a measure of "cold spots" below the prescription dose in the target dose distribution, using units of gray (Gy). We investigate the mathematical properties of various target EUD concepts, including tail EUD. We apply the tail EUD measure retrospectively to intensity modulated radiation therapy (IMRT) treatment plans from our plan database. We also use tail EUD as an optimization objective in the optimization of prostate, pancreas, and head-and-neck plans. RESULTS: Tail EUD has desirable mathematical properties. In particular, it is convex and it leads to convex level sets (i.e., no local minima) if the EUD from which it is derived is concave. The tail EUD value is correlated with the subjective degree of target coverage. Constraining tail EUDs to a certain level in plan optimization leads to comparable target coverage in different plans and treatment sites. CONCLUSIONS: The newly introduced concept of tail EUD appears to be useful for both plan evaluation and optimization. In addition it can potentially be applied in the design of new clinical protocols.


Algorithms , Models, Biological , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Computer Simulation , Humans , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity
18.
Phys Med Biol ; 52(24): 7333-52, 2007 Dec 21.
Article En | MEDLINE | ID: mdl-18065842

We consider the problem of intensity-modulated radiation therapy (IMRT) treatment planning using direct aperture optimization. While this problem has been relatively well studied in recent years, most approaches employ a heuristic approach to the generation of apertures. In contrast, we use an exact approach that explicitly formulates the fluence map optimization (FMO) problem as a convex optimization problem in terms of all multileaf collimator (MLC) deliverable apertures and their associated intensities. However, the number of deliverable apertures, and therefore the number of decision variables and constraints in the new problem formulation, is typically enormous. To overcome this, we use an iterative approach that employs a subproblem whose optimal solution either provides a suitable aperture to add to a given pool of allowable apertures or concludes that the current solution is optimal. We are able to handle standard consecutiveness, interdigitation and connectedness constraints that may be imposed by the particular MLC system used, as well as jaws-only delivery. Our approach has the additional advantage that it can explicitly account for transmission of dose through the part of an aperture that is blocked by the MLC system, yielding a more precise assessment of the treatment plan than what is possible using a traditional beamlet-based FMO problem. Finally, we develop and test two stopping rules that can be used to identify treatment plans of high clinical quality that are deliverable very efficiently. Tests on clinical head-and-neck cancer cases showed the efficacy of our approach, yielding treatment plans comparable in quality to plans obtained by the traditional method with a reduction of more than 75% in the number of apertures and a reduction of more than 50% in beam-on time, with only a modest increase in computational effort. The results also show that delivery efficiency is very insensitive to the addition of traditional MLC constraints; however, jaws-only treatment requires about a doubling in beam-on time and number of apertures used. Finally, we showed the importance of accounting for transmission effects when assessing or, preferably, optimizing treatment plan quality.


Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Artifacts , Clinical Protocols , Computer Simulation , Dose-Response Relationship, Radiation , Head and Neck Neoplasms/diagnostic imaging , Humans , Numerical Analysis, Computer-Assisted , Phantoms, Imaging , Radiotherapy Dosage , Relative Biological Effectiveness , Reproducibility of Results , Sensitivity and Specificity , Ultrasonography
19.
Phys Med Biol ; 52(19): 5973-84, 2007 Oct 07.
Article En | MEDLINE | ID: mdl-17881813

Optimization of equivalent uniform dose (EUD) in inverse planning for intensity-modulated radiation therapy (IMRT) prevents variation in radiobiological effect between different radiotherapy treatment plans, which is due to variation in the pattern of dose nonuniformity. For instance, the survival fraction of clonogens would be consistent with the prescription when the optimized EUD is equal to the prescribed EUD. One of the problems in the practical implementation of this approach is that the spatial dose distribution in EUD-based inverse planning would be underdetermined because an unlimited number of nonuniform dose distributions can be computed for a prescribed value of EUD. Together with ill-posedness of the underlying integral equation, this may significantly increase the dose nonuniformity. To optimize EUD and keep dose nonuniformity within reasonable limits, we implemented into an EUD-based objective function an additional criterion which ensures the smoothness of beam intensity functions. This approach is similar to the variational regularization technique which was previously studied for the dose-based least-squares optimization. We show that the variational regularization together with the L-curve criterion for the regularization parameter can significantly reduce dose nonuniformity in EUD-based inverse planning.


Algorithms , Models, Biological , Neoplasms/radiotherapy , Quality Assurance, Health Care/methods , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Computer Simulation , Humans , Neoplasms/physiopathology , Quality Control , Radiotherapy Dosage , Relative Biological Effectiveness , Reproducibility of Results , Sensitivity and Specificity , Therapeutic Equivalency
20.
Med Phys ; 34(6): 2228-58, 2007 Jun.
Article En | MEDLINE | ID: mdl-17654924

TG-69 is a task group report of the AAPM on the use of radiographic film for dosimetry. Radiographic films have been used for radiation dosimetry since the discovery of x-rays and have become an integral part of dose verification for both routine quality assurance and for complex treatments such as soft wedges (dynamic and virtual), intensity modulated radiation therapy (IMRT), image guided radiation therapy (IGRT), and small field dosimetry like stereotactic radiosurgery. Film is convenient to use, spatially accurate, and provides a permanent record of the integrated two dimensional dose distributions. However, there are several challenges to obtaining high quality dosimetric results with film, namely, the dependence of optical density on photon energy, field size, depth, film batch sensitivity differences, film orientation, processing conditions, and scanner performance. Prior to the clinical implementation of a film dosimetry program, the film, processor, and scanner need to be tested to characterize them with respect to these variables. Also, the physicist must understand the basic characteristics of all components of film dosimetry systems. The primary mission of this task group report is to provide guidelines for film selection, irradiation, processing, scanning, and interpretation to allow the physicist to accurately and precisely measure dose with film. Additionally, we present the basic principles and characteristics of film, processors, and scanners. Procedural recommendations are made for each of the steps required for film dosimetry and guidance is given regarding expected levels of accuracy. Finally, some clinical applications of film dosimetry are discussed.


Advisory Committees , Film Dosimetry/instrumentation , Film Dosimetry/standards , Radiotherapy, High-Energy/instrumentation , Radiotherapy, High-Energy/standards , Societies, Scientific , Practice Guidelines as Topic
...