Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 17 de 17
1.
Materials (Basel) ; 16(11)2023 Jun 01.
Article En | MEDLINE | ID: mdl-37297263

Over the past few years, alternative power supplies to either supplement or replace batteries for electronic textile and wearable applications have been sought, with the development of wearable solar energy harvesting systems gaining significant interest. In a previous publication the authors reported a novel concept to craft a yarn capable of harvesting solar energy by embedding miniature solar cells within the fibers of a yarn (solar electronic yarns). The aim of this publication is to report the development of a large-area textile solar panel. This study first characterized the solar electronic yarns, and then analyzed the solar electronic yarns once woven into double cloth woven textiles; as part of this study, the effect of different numbers of covering warp yarns on the performance of the embedded solar cells was explored. Finally, a larger woven textile solar panel (510 mm × 270 mm) was constructed and tested under different light intensities. It was observed that a PMAX = 335.3 ± 22.4 mW of energy could be harvested on a sunny day (under 99,000 lux lighting conditions).

2.
Materials (Basel) ; 16(5)2023 Feb 25.
Article En | MEDLINE | ID: mdl-36903036

Falls can be detrimental to the quality of life of older people, and therefore the ability to detect falls is beneficial, especially if the person is living alone and has injured themselves. In addition, detecting near falls (when a person is imbalanced or stumbles) has the potential to prevent a fall from occurring. This work focused on the design and engineering of a wearable electronic textile device to monitor falls and near-falls and used a machine learning algorithm to assist in the interpretation of the data. A key driver behind the study was to create a comfortable device that people would be willing to wear. A pair of over-socks incorporating a single motion sensing electronic yarn each were designed. The over-socks were used in a trial involving 13 participants. The participants performed three types of activities of daily living (ADLs), three types of falls onto a crash mat, and one type of near-fall. The trail data was visually analyzed for patterns, and a machine learning algorithm was used to classify the data. The developed over-socks combined with the use of a bidirectional long short-term memory (Bi-LSTM) network have been shown to be able to differentiate between three different ADLs and three different falls with an accuracy of 85.7%, ADLs and falls with an accuracy of 99.4%, and ADLs, falls, and stumbles (near-falls) with an accuracy of 94.2%. In addition, results showed that the motion sensing E-yarn only needs to be present in one over-sock.

3.
Technol Health Care ; 30(3): 713-724, 2022.
Article En | MEDLINE | ID: mdl-34542047

BACKGROUND: Electromyographic systems are widely used in scientific and clinical practice. The reproducibility and reliability of these measures are crucial when conducting scientific research and collecting experimental data. OBJECTIVE: To test the reliability of surface electromyography signals from both the Flexor Digitorum Superficialis (FDS) and Extensor Carpi Radialis Brevis (ECRB) muscles of both the left and right arms during an individual, static multi-planar maximum voluntary contraction handgrip task using the Myon 320 system (Myon AG, Switzerland). METHODS: Eight right-handed male participants performed two maximal handgrip tests in five separate wrist positions using both hands. Muscle activity was recorded from both forearms. Reliability was measured using the Standard Error of Measurement (SEM), Coefficient of Variation (CV) and Intra-class correlation coefficients. Wrist joint position correlations within and between the FDS and ECRB muscle activities were also analysed. RESULTS: Absolute reliability was shown across all positions for both hands with CV and SEM recorded at below 10%. The output measures indicate that the Myon 320 system (Myon AG, Switzerland) produces good to fair reliability when assessing forearm muscle activity. Correlations in the left FDS muscles were negative. Correlations between the left ECRB and left FDS muscles were variable but positive between the right ECRB and right FDS muscles. CONCLUSIONS: The data sets retrieved from all participants were reliably evaluated. Wrist position correlations within and between the FDS and ECRB muscles may have been influenced by hand dominance. The findings demonstrate that the methods and systems outlined in this study can be used reliably in future research.


Forearm , Hand Strength , Electromyography/methods , Forearm/physiology , Hand Strength/physiology , Humans , Male , Muscle Contraction/physiology , Muscle, Skeletal/physiology , Pilot Projects , Reproducibility of Results , Wrist/physiology , Wrist Joint
4.
Appl Bionics Biomech ; 2021: 1232468, 2021.
Article En | MEDLINE | ID: mdl-34589138

There is limited research on the biomechanical assessment of the lower limb joints in relation to dynamic movements that occur at the hip, knee, and ankle joints when performing dorsiflexion (DF) and plantarflexion (PF) among males and females. This study investigated the differences in joint angles (including range of motion (ROM)) and forces (including moments) between the left and right limbs at the ankle, knee, and hip joints during dynamic DF and PF movements in both males and females. Using a general linear model employing multivariate analysis in relation to the joint angle, ROM, force, and moment datasets, the results revealed significant main effects for gender, sidedness, phases, and foot position with respect to joint angles. Weak correlations were observed between measured biomechanical variables. These results provide insightful information for clinicians and biomechanists that relate to lower limb exercise interventions and modelling efficacy standpoints.

5.
Healthcare (Basel) ; 9(4)2021 Apr 14.
Article En | MEDLINE | ID: mdl-33919959

Only a small number of muscle activation patterns from lower limbs have been reported and simultaneous muscle activation from several lower limb muscles have not yet been investigated. The purpose of this study was to examine any gender differences in surface electromyography (EMG) activity from six recorded lower limb muscles of the dominant limb at baseline (i.e., with the foot placed flat on the floor and in the neutral position), and during concentric and eccentric phases when performing a heel raise task. In total, 10 females and 10 males performed a standing heel raise task comprising of three continuous phases: baseline, unloading (concentric muscle action), and loading (eccentric muscle action) phases. Muscle activation from six muscles (gastrocnemius medialis, gastrocnemius lateralis, soleus, tibialis anterior, peroneus longus, and peroneus brevis) were measured using the Myon 320 EMG System. Root mean squared values of each muscle were calculated for each phase. Descriptive and inferential statistics were incorporated into the study. Statistically significant p values were set at 0.05. The results showed no significant differences between baseline, concentric, and eccentric phases with respect to each of the muscles investigated. Except for the gastrocnemius medialis at baseline and concentric phases, no significant differences were observed between genders or contractions. The data suggests that gender does not significantly influence the eccentric phase during the standing heel raise task.

6.
Sensors (Basel) ; 21(8)2021 Apr 15.
Article En | MEDLINE | ID: mdl-33920830

Overexposure to hand transmitted vibrations (HTVs) from prolonged use of vibrating power tools can result in severe injuries. By monitoring the exposure of a worker to HTVs, overexposure, and injury, can be mitigated. An ideal HTV-monitoring system would measure vibration were it enters the body, which for many power tools will be the palm and fingers, however this is difficult to achieve using conventional transducers as they will affect the comfort of the user and subsequently alter the way that the tool is held. By embedding a transducer within the core of a textile yarn, that can be used to produce a glove, vibration can be monitored close to where it enters the body without compromising the comfort of the user. This work presents a vibration-sensing electronic yarn that was created by embedding a commercially available accelerometer within the structure of a yarn. These yarns were subsequently used to produce a vibration-sensing glove. The purpose of this study is to characterize the response of the embedded accelerometer over a range of relevant frequencies and vibration amplitudes at each stage of the electronic yarn's manufacture to understand how the yarn structure influences the sensors response. The vibration-sensing electronic yarn was subsequently incorporated into a fabric sample and characterized. Finally, four vibration-sensing electronic yarns were used to produce a vibration-sensing glove that is capable of monitoring vibration at the palm and index finger.


Textiles , Vibration , Electronics , Gloves, Protective , Hand
7.
Sensors (Basel) ; 20(20)2020 Oct 21.
Article En | MEDLINE | ID: mdl-33096633

An increased use in wearable, mobile, and electronic textile sensing devices has led to a desire to keep these devices continuously powered without the need for frequent recharging or bulky energy storage. To achieve this, many have proposed integrating energy harvesting capabilities into clothing: solar energy harvesting has been one of the most investigated avenues for this due to the abundance of solar energy and maturity of photovoltaic technologies. This review provides a comprehensive, contemporary, and accessible overview of electronic textiles that are capable of harvesting solar energy. The review focusses on the suitability of the textile-based energy harvesting devices for wearable applications. While multiple methods have been employed to integrate solar energy harvesting with textiles, there are only a few examples that have led to devices with textile properties.

8.
Sensors (Basel) ; 20(20)2020 Oct 12.
Article En | MEDLINE | ID: mdl-33053873

The aim of the publication is to report the accuracy, repeatability and the linearity of three commercially available interface pressure measurement systems employed in the treatment of venous disease. The advances in the treatment and management of chronic venous disease by compression therapy have led to considerable research interest in interface pressure measurement systems capable of measuring low-pressure ranges (10-60 mmHg). The application of a graduated pressure profile is key for the treatment of chronic venous disease which is achieved by using compression bandages or stockings; the required pressure profiles are defined in standards (BSI, RAL-GZ, or AFNOR) for different conditions. However, achieving the recommended pressure levels and its accuracy is still deemed to be a challenge. Thus, it is vital to choose a suitable pressure measurement system with high accuracy of interface pressure. The authors investigated the sensing performance of three commercially available different pressure sensors: two pneumatic based (AMI and PicoPress®) and one piezoresistive (FlexiForce®) pressure sensors, with extensive experimental work on their performance in terms of linearity, repeatability, and accuracy. Both pneumatic based pressure measurement systems have shown higher accuracy in comparison to the flexible piezoresistive pressure sensors.


Vascular Diseases , Chronic Disease , Equipment Design , Humans , Pressure , Vascular Diseases/diagnosis , Veins
9.
Materials (Basel) ; 13(5)2020 Mar 09.
Article En | MEDLINE | ID: mdl-32182823

Electronically active yarn (E-yarn) pioneered by the Advanced Textiles Research Group of Nottingham Trent University contains a fine conductive copper wire soldered onto a package die, micro-electro-mechanical systems device or flexible circuit. The die or circuit is then held within a protective polymer packaging (micro-pod) and the ensemble is inserted into a textile sheath, forming a flexible yarn with electronic functionality such as sensing or illumination. It is vital to be able to wash E-yarns, so that the textiles into which they are incorporated can be treated as normal consumer products. The wash durability of E-yarns is summarized in this publication. Wash tests followed a modified version of BS EN ISO 6330:2012 procedure 4N. It was observed that E-yarns containing only a fine multi-strand copper wire survived 25 cycles of machine washing and line drying; and between 5 and 15 cycles of machine washing followed by tumble-drying. Four out of five temperature sensing E-yarns (crafted with thermistors) and single pairs of LEDs within E-yarns functioned correctly after 25 cycles of machine washing and line drying. E-yarns that required larger micro-pods (i.e., 4 mm diameter or 9 mm length) were less resilient to washing. Only one out of five acoustic sensing E-yarns (4 mm diameter micro-pod) operated correctly after 20 cycles of washing with either line drying or tumble-drying. Creating an E-yarn with an embedded flexible circuit populated with components also required a relatively large micro-pod (diameter 0.93 mm, length 9.23 mm). Only one embedded circuit functioned after 25 cycles of washing and line drying. The tests showed that E-yarns are suitable for inclusion in textiles that require washing, with some limitations when larger micro-pods were used. Reduction in the circuit's size and therefore the size of the micro-pod, may increase wash resilience.

10.
Polymers (Basel) ; 12(1)2020 Jan 07.
Article En | MEDLINE | ID: mdl-31936039

This paper presents the fundamental research of design, development, and evaluation of an active compression system consisting of silicone based inflatable mini-bladders, which could be used in applying radial pressure for the treatment of venous disease. The use of mini-bladders will nullify the effect of radius of curvature and provide a higher resolution to the pressure distribution. They are designed with two elastomeric layers and inflation is limited only to one side. The mini-bladders apply a radial force onto the treated surface when inflated, and the pressure inside mini-bladders could be measured using the concept of back pressure, which provides the flexibility to inflate mini-bladders to a predefined pressure. The 3-D deformation profile of the mini-bladders was analysed using finite element method (FEM) and FEM simulations were validated with experimental data, which showed good agreement within pressure region required for the treatment of venous disease. Finally, the pressure transmission characteristics of mini-bladders were evaluated on a biofidellic lower leg surrogate and the results have shown that the mini-bladders could apply a uniform pressure irrespective of the location on the leg with a 60%-70% of inlet pressure successfully transmitted onto the leg surface, while 40%-50% was available after the fat layers.

11.
Sensors (Basel) ; 20(1)2019 Dec 21.
Article En | MEDLINE | ID: mdl-31877742

Textiles enhanced with thin-film flexible sensors are well-suited for unobtrusive monitoring of skin parameters due to the sensors' high conformability. These sensors can be damaged if they are attached to the surface of the textile, also affecting the textiles' aesthetics and feel. We investigate the effect of embedding flexible temperature sensors within textile yarns, which adds a layer of protection to the sensor. Industrial yarn manufacturing techniques including knit braiding, braiding, and double covering were utilised to identify an appropriate incorporation technique. The thermal time constants recorded by all three sensing yarns was <10 s. Simultaneously, effective sensitivity only decreased by a maximum of 14% compared to the uncovered sensor. This is due to the sensor being positioned within the yarn instead of being in direct contact with the measured surface. These sensor yarns were not affected by bending and produced repeatable measurements. The double covering method was observed to have the least impact on the sensors' performance due to the yarn's smaller dimensions. Finally, a sensing yarn was incorporated in an armband and used to measure changes in skin temperature. The demonstrated textile integration techniques for flexible sensors using industrial yarn manufacturing processes enable large-scale smart textile fabrication.

12.
Materials (Basel) ; 12(22)2019 Nov 06.
Article En | MEDLINE | ID: mdl-31698723

Silicone-based elastomers saturated with embedded, short-strand fibres are used for their ability to mimic the aesthetic qualities of skin in clinical and theatrical maxillofacial appliance design. Well-known to prostheses fabricators and technicians, the mechanical impact of fibre addition on elastomeric behaviour endures as tacit, embodied knowledge of the craft, almost unknown in the literature. To examine mechanical changes caused by fibre addition, 100 modified polydimethylsiloxane (PDMS) elastomeric compounds containing incremental amounts of loose polyester fibres were prepared and examined in a variety of mechanical tests. It was found that elasticity and strain percentage at breaking point was reduced by increasing fibre content, but Young's modulus and ultimate tensile strength (UTS) increased. As fibre content was increased, strain hardening was seen at low strain rates, but exaggerated plastic deformation at high strain rates. PDMS hardness increased by 5 degrees of hardness (Shore-00 scale) for every additional percentage of fibres added and a strong positive linear coefficient (0.993 and 0.995) was identified to reach the hardness values given in the literature for living human skin. The apparent reorienting of loose fibres in the PDMS interrupts and absorbs stress during the loading process similar to the organic response to soft tissue loading, except in extension.

13.
Sci Rep ; 8(1): 16205, 2018 11 01.
Article En | MEDLINE | ID: mdl-30385876

A novel photodiode-embedded yarn has been presented and characterized for the first time, offering new possibilities for applications including monitoring body vital signs (including heart rate, blood oxygen and skin temperature) and environmental conditions (light, humidity and ultraviolet radiation). To create an E-Textile integrated with electronic devices that is comfortable, conformal, aesthetically pleasing and washable, electronic components are best integrated within the structure of a textile fabric in yarn form. The device is first encapsulated within a protective clear resin micro-pod before being covered in a fibrous sheath. The resin micro-pod and covering fibres have a significant effect on the nature of light received by the photoactive region of the device. This work characterised the effects of both encapsulating photodiodes within resin micro-pods and covering the micro-pod with a fibrous sheath on the opto-electronic parameters. A theoretical model is presented to provide an estimate for these effects and validated experimentally using two photodiode types and a range of different resin micro-pods. This knowledge may have wider applications to other devices with small-scale opto-electronic components. Wash tests confirmed that the yarns could survive multiple machine wash and drying cycles without deterioration in performance.

14.
Sensors (Basel) ; 18(7)2018 Jul 21.
Article En | MEDLINE | ID: mdl-30037070

In medicine, temperature changes can indicate important underlying pathologies such as wound infection. While thermographs for the detection of wound infection exist, a textile substrate offers a preferable solution to the designs that exist in the literature, as a textile is very comfortable to wear. This work presents a fully textile, wearable, thermograph created using temperature-sensing yarns. As described in earlier work, temperature-sensing yarns are constructed by encapsulating an off-the-shelf thermistor into a polymer resin micro-pod and then embedding this within the fibres of a yarn. This process creates a temperature-sensing yarn that is conformal, drapeable, mechanically resilient, and washable. This work first explored a refined yarn design and characterised its accuracy to take absolute temperature measurements. The influence of contact errors with the refined yarns was explored seeing a 0.24 ± 0.03 measurement error when the yarn was held just 0.5 mm away from the surface being measured. Subsequently, yarns were used to create a thermograph. This work characterises the operation of the thermograph under a variety of simulated conditions to better understand the functionality of this type of textile temperature sensor. Ambient temperature, insulating material, humidity, moisture, bending, compression and stretch were all explored. This work is an expansion of an article published in The 4th International Conference on Sensor and Applications.


Textiles , Thermography/instrumentation , Wearable Electronic Devices , Humans , Humidity , Polymers , Temperature
15.
Sensors (Basel) ; 18(5)2018 May 17.
Article En | MEDLINE | ID: mdl-29772756

Overexposure to high levels of noise can cause permanent hearing disorders, which have a significant adverse effect on the quality of life of those affected. Injury due to noise can affect people in a variety of careers including construction workers, factory workers, and members of the armed forces. By monitoring the noise exposure of workers, overexposure can be avoided and suitable protective equipment can be provided. This work focused on the creation of a noise dosimeter suitable for use by members of the armed forces, where a discrete dosimeter was integrated into a textile helmet cover. In this way the sensing elements could be incorporated very close to the ears, providing a highly representative indication of the sound level entering the body, and also creating a device that would not interfere with military activities. This was achieved by utilising commercial microelectromechanical system microphones integrated within the fibres of yarn to create an acoustic sensing yarn. The acoustic sensing yarns were fully characterised over a range of relevant sound levels and frequencies at each stage in the yarn production process. The yarns were ultimately integrated into a knitted helmet cover to create a functional acoustic sensing helmet cover prototype.


Health Surveys/methods , Military Personnel , Sound , Head Protective Devices , Health Surveys/instrumentation , Humans , Micro-Electrical-Mechanical Systems , Occupational Diseases/diagnosis , Tinnitus/diagnosis
16.
Sensors (Basel) ; 17(8)2017 Aug 05.
Article En | MEDLINE | ID: mdl-28783067

Textiles provide an ideal structure for embedding sensors for medical devices. Skin temperature measurement is one area in which a sensor textile could be particularly beneficial; pathological skin is normally very sensitive, making the comfort of anything placed on that skin paramount. Skin temperature is an important parameter to measure for a number of medical applications, including for the early detection of diabetic foot ulcer formation. To this end an electronic temperature-sensor yarn was developed by embedding a commercially available thermistor chip into the fibres of a yarn, which can be used to produce a textile or a garment. As part of this process a resin was used to encapsulate the thermistor. This protects the thermistor from mechanical and chemical stresses, and also allows the sensing yarn to be washed. Building off preliminary work, the behaviour and performance of an encapsulated thermistor has been characterised to determine the effect of encapsulation on the step response time and absolute temperature measurements. Over the temperature range of interest only a minimal effect was observed, with step response times varying between 0.01-0.35 s. A general solution is presented for the heat transfer coefficient compared to size of the micro-pod formed by the encapsulation of the thermistor. Finally, a prototype temperature-sensing sock was produced using a network of sensing yarns as a demonstrator of a system that could warn of impending ulcer formation in diabetic patients.


Textiles
17.
J Neuroeng Rehabil ; 8: 32, 2011 May 27.
Article En | MEDLINE | ID: mdl-21619570

BACKGROUND: Textile-based transducers are an emerging technology in which piezo-resistive properties of materials are used to measure an applied strain. By incorporating these sensors into a sock, this technology offers the potential to detect critical events during the stance phase of the gait cycle. This could prove useful in several applications, such as functional electrical stimulation (FES) systems to assist gait. METHODS: We investigated the output of a knitted resistive strain sensor during walking and sought to determine the degree of similarity between the sensor output and the ankle angle in the sagittal plane. In addition, we investigated whether it would be possible to predict three key gait events, heel strike, heel lift and toe off, with a relatively straight-forward algorithm. This worked by predicting gait events to occur at fixed time offsets from specific peaks in the sensor signal. RESULTS: Our results showed that, for all subjects, the sensor output exhibited the same general characteristics as the ankle joint angle. However, there were large between-subjects differences in the degree of similarity between the two curves. Despite this variability, it was possible to accurately predict gait events using a simple algorithm. This algorithm displayed high levels of trial-to-trial repeatability. CONCLUSIONS: This study demonstrates the potential of using textile-based transducers in future devices that provide active gait assistance.


Ankle Joint/physiology , Foot/physiology , Gait/physiology , Textiles , Algorithms , Ankle Joint/anatomy & histology , Biomechanical Phenomena , Calibration , Data Interpretation, Statistical , Electric Conductivity , Electric Stimulation , Foot/anatomy & histology , Heel/anatomy & histology , Heel/physiology , Humans , Leg/anatomy & histology , Leg/physiology , Toes/anatomy & histology , Toes/physiology , Transducers , Walking/physiology
...