Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 35
1.
J Neurosurg ; : 1-8, 2024 May 03.
Article En | MEDLINE | ID: mdl-38701528

OBJECTIVE: This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS: A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS: The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS: The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.

2.
J Neurointerv Surg ; 2024 Apr 12.
Article En | MEDLINE | ID: mdl-38609175

This review focuses on the often-neglected long-term neuropsychiatric consequences of aneurysmal subarachnoid hemorrhage (aSAH), beyond traditional randomized trial outcomes of mortality and retreatment. While current guidelines recommend screening for these sequalae, it may not be routinely practiced. This review will underscore the prevalence and management of common neuropsychiatric sequalae, including anxiety, depression, cognitive dysfunction, headaches, seizures, and sexual dysfunction, all of which can significantly impact the quality of life of survivors of aSAH. We emphasize the critical role neurointerventionalists can play by going beyond the customary practice of radiological monitoring for treated aneurysms by screening for and helping guide management of these common neuropsychiatric complications.

3.
J Neurointerv Surg ; 2024 Mar 21.
Article En | MEDLINE | ID: mdl-38453461

BACKGROUND: Limited research exists regarding the impact of neuroimaging on endovascular thrombectomy (EVT) decisions for late-window cases of large vessel occlusion (LVO) stroke. OBJECTIVE: T0 assess whether perfusion CT imaging: (1) alters the proportion of recommendations for EVT, and (2) enhances the reliability of EVT decision-making compared with non-contrast CT and CT angiography. METHODS: We conducted a survey using 30 patients drawn from an institutional database of 3144 acute stroke cases. These were presented to 29 Canadian physicians with and without perfusion imaging. We used non-overlapping 95% confidence intervals and difference in agreement classification as criteria to suggest a difference between the Gwet AC1 statistics (κG). RESULTS: The percentage of EVT recommendations differed by 1.1% with or without perfusion imaging. Individual decisions changed in 21.4% of cases (11.3% against EVT and 10.1% in favor). Inter-rater agreement (κG) among the 29 raters was similar between non-perfusion and perfusion CT neuroimaging (κG=0.487; 95% CI 0.327 to 0.647 and κG=0.552; 95% CI 0.430 to 0.675). The 95% CIs overlapped with moderate agreement in both. Intra-rater agreement exhibited overlapping 95% CIs for all 28 raters. κG was either substantial or excellent (0.81-1) for 71.4% (20/28) of raters in both groups. CONCLUSIONS: Despite the minimal difference in overall EVT recommendations with either neuroimaging protocol one in five decisions changed with perfusion imaging. Regarding agreement we found that the use of automated CT perfusion images does not significantly impact the reliability of EVT decisions for patients with late-window LVO.

4.
Neuroradiology ; 66(4): 631-641, 2024 Apr.
Article En | MEDLINE | ID: mdl-38381145

PURPOSE: Our purpose was to assess the efficacy and safety of the pRESET LITE stent retriever (Phenox, Bochum, Germany), designed for medium vessel occlusion (MeVO) in acute ischemic stroke (AIS) patients with a primary MeVO. METHODS: We performed a retrospective analysis of the MAD MT Consortium, an integration of prospectively maintained databases at 37 academic institutions in Europe, North America, and Asia, of AIS patients who underwent mechanical thrombectomy with the pRESET LITE stent retriever for a primary MeVO. We subcategorized occlusions into proximal MeVOs (segments A1, M2, and P1) vs. distal MeVOs/DMVO (segments A2, M3-M4, and P2). We reviewed patient and procedural characteristics, as well as angiographic and clinical outcomes. RESULTS: Between September 2016 and December 2021, 227 patients were included (50% female, median age 78 [65-84] years), of whom 161 (71%) suffered proximal MeVO and 66 (29%) distal MeVO. Using a combined approach in 96% of cases, successful reperfusion of the target vessel (mTICI 2b/2c/3) was attained in 85% of proximal MeVO and 97% of DMVO, with a median of 2 passes (IQR: 1-3) overall. Periprocedural complications rate was 7%. Control CT at day 1 post-MT revealed a hemorrhagic transformation in 63 (39%) patients with proximal MeVO and 24 (36%) patients with DMVO, with ECASS-PH type hemorrhagic transformations occurring in 3 (1%) patients. After 3 months, 58% of all MeVO and 63% of DMVO patients demonstrated a favorable outcome (mRS 0-2). CONCLUSION: Mechanical thrombectomy using the pRESET LITE in a combined approach with an aspiration catheter appears effective for primary medium vessel occlusions across several centers and physicians.


Brain Ischemia , Endovascular Procedures , Ischemic Stroke , Stroke , Aged , Female , Humans , Male , Brain Ischemia/complications , Ischemic Stroke/etiology , Retrospective Studies , Stents , Stroke/etiology , Thrombectomy , Treatment Outcome , Aged, 80 and over
6.
PLoS One ; 19(1): e0297520, 2024.
Article En | MEDLINE | ID: mdl-38289912

BACKGROUND: Guidelines recommend the use of perfusion computed tomography (CT) to identify emergent large vessel ischemic stroke (ELVIS) patients who are likely to benefit from endovascular thrombectomy (EVT) if they present within 6-24 hour (late window) of stroke onset. We aim to determine if the interrater and intrarater reliability among physicians when recommending EVT is significantly different when perfusion CT or non-perfusion CT is reviewed. METHODS: A total of 30 non-consecutive patients will be selected from our institutional database comprising 3144 cranial CT scans performed for acute stroke symptoms January 2018 to August 2022. The clinical and radiologic data of the 30 patients will be presented in random order to a group of 29 physicians in two separate sessions at least three weeks apart. In each session, the physicians will evaluate each patient once with automated perfusion images and once without. We will use non-overlapping 95% confidence intervals and difference in agreement classification as criteria to suggest a difference between the Gwet AC1 statistics (κG). DISCUSSION: The results obtained from this study, combined with the clinical outcomes data of patients categorized through the two imaging techniques and a cost-effectiveness analysis, will offer a comprehensive evaluation of the clinical utility of perfusion CT neuroimaging. Should there be no significant disparity in the reliability of decisions made by clinicians using the two neuroimaging protocols, it may be necessary to revise existing recommendations regarding neuroimaging in the later time window to align with these findings.


Brain Ischemia , Endovascular Procedures , Ischemic Stroke , Stroke , Humans , Brain Ischemia/diagnostic imaging , Brain Ischemia/therapy , Clinical Decision-Making , Endovascular Procedures/methods , Perfusion , Reproducibility of Results , Retrospective Studies , Stroke/diagnostic imaging , Stroke/therapy , Thrombectomy/methods , Treatment Outcome , Uncertainty
7.
Eur Stroke J ; 9(1): 114-123, 2024 Mar.
Article En | MEDLINE | ID: mdl-37885243

INTRODUCTION: First pass effect (FPE), achievement of complete recanalization (mTICI 2c/3) with a single pass, is a significant predictor of favorable outcomes for endovascular treatment (EVT) in large vessel occlusion stroke (LVO). However, data concerning the impact on functional outcomes and predictors of FPE in medium vessel occlusions (MeVO) are scarce. PATIENTS AND METHODS: We conducted an international retrospective study on MeVO cases. Multivariable logistic modeling was used to establish independent predictors of FPE. Clinical and safety outcomes were compared between the two study groups (FPE vs non-FPE) using logistic regression models. Good outcome was defined as modified Rankin Scale 0-2 at 3 months. RESULTS: Eight hundred thirty-six patients with a final mTICI ⩾ 2b were included in this analysis. FPE was observed in 302 patients (36.1%). In multivariable analysis, hypertension (aOR 1.55, 95% CI 1.10-2.20) and lower baseline NIHSS score (aOR 0.95, 95% CI 0.93-0.97) were independently associated with an FPE. Good outcomes were more common in the FPE versus non-FPE group (72.8% vs 52.8%), and FPE was independently associated with favorable outcome (aOR 2.20, 95% CI 1.59-3.05). 90-day mortality and intracranial hemorrhage (ICH) were significantly lower in the FPE group, 0.43 (95% CI, 0.25-0.72) and 0.55 (95% CI, 0.39-0.77), respectively. CONCLUSION: Over 2/3 of patients with MeVOs and FPE in our cohort had a favorable outcome at 90 days. FPE is independently associated with favorable outcomes, it may reduce the risk of any intracranial hemorrhage, and 3-month mortality.


Brain Ischemia , Stroke , Humans , Brain Ischemia/therapy , Retrospective Studies , Thrombectomy , Treatment Outcome , Intracranial Hemorrhages/etiology
8.
J Neurosurg ; 140(4): 1071-1079, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-37862717

OBJECTIVE: The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS: The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS: The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS: This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.


Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Treatment Outcome , Retrospective Studies , Stents
10.
Neuroradiology ; 65(9): 1353-1361, 2023 Sep.
Article En | MEDLINE | ID: mdl-37480480

PURPOSE: Middle cerebral aneurysms were underrepresented in the two largest trials (BRAT and ISAT) for the treatment of ruptured intracranial aneurysms. Recent institutional series addressing the choice between endovascular or open repair for this subset of aneurysms are few and have not yielded a definitive conclusion. We compare clinical outcomes of patients presenting with acute subarachnoid hemorrhage from ruptured middle cerebral artery aneurysms undergoing either open or endovascular repair. METHODS: We conducted a retrospective review of 138 consecutive patients with ruptured middle cerebral artery aneurysms admitted into our institution from January 2008 to March 2019 to compare endovascular and open surgical outcomes. RESULTS: Of the ruptured middle cerebral artery aneurysms, 57 underwent endovascular repair while 81 were treated with open surgery. Over the study period, there was a notable shift in practice toward more frequent endovascular treatment of ruptured MCA aneurysms (31% in 2008 vs. 91% in 2018). At discharge (49.1% vs 29.6%; p = .002) and at 6 months (84.3% vs 58.6%; p = 0.003), patients who underwent endovascular repair had a higher proportion of patients with good clinical outcomes (mRS 0-2) compared to those undergoing open surgery. Long-term follow-up data (endovascular 54.9 ± 37.9 months vs clipping 18.6 ± 13.4 months) showed no difference in rebleeding (1.8% vs 3.7%, p = 0.642) and retreatment (5.3% vs 3.7%, p = 0.691) in both groups. CONCLUSION: Our series suggests equipoise in the treatment of ruptured middle cerebral artery aneurysms and demonstrates endovascular repair as a potentially feasible treatment strategy. Future randomized trials could clarify the roles of these treatment modalities.


Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Subarachnoid Hemorrhage , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Intracranial Aneurysm/etiology , Treatment Outcome , Subarachnoid Hemorrhage/diagnostic imaging , Subarachnoid Hemorrhage/surgery , Subarachnoid Hemorrhage/etiology , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/surgery , Aneurysm, Ruptured/etiology , Embolization, Therapeutic/adverse effects , Retrospective Studies
11.
Transl Stroke Res ; 2023 May 11.
Article En | MEDLINE | ID: mdl-37165289

The Woven EndoBridge (WEB) device has been widely used to treat intracranial wide neck bifurcation aneurysms. Initial studies have demonstrated that approximately 90% of patients have same or improved long-term aneurysm occlusion after the initial 6-month follow up. The aim of this study is to assess the long-term follow-up in aneurysms that have achieved complete occlusion at 6 months. We also compared the predictive value of different imaging modalities used. This is an analysis of a prospectively maintained database across 13 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB device who achieved complete occlusion at first follow-up and had available long-term follow-up. A total of 95 patients with a mean age of 61.6 ± 11.9 years were studied. The mean neck diameter and height were 3.9 ± 1.3 mm and 6.0 ± 1.8 mm, respectively. The mean time to first and last follow-up was 5.4 ± 1.8 and 14.1 ± 12.9 months, respectively. Out of all the aneurysms that were completely occluded at 6 months, 84 (90.3%) showed complete occlusion at the final follow-up, and 11(11.5%) patients did not achieve complete occlusion. The positive predictive value (PPV) of complete occlusion at first follow was 88.4%. Importantly, this did not differ between digital subtraction angiography (DSA), magnetic resonance angiography (MRA), or computed tomography angiography (CTA). This study underlines the importance of repeat imaging in patients treated with the WEB device even if complete occlusion is achieved short term. Follow-up can be performed using DSA, MRA or CTA with no difference in positive predictive value.

12.
Neuroradiol J ; 36(6): 686-692, 2023 Dec.
Article En | MEDLINE | ID: mdl-37211821

BACKGROUND: Timely restoration of cerebral blood flow using reperfusion therapy is the most effective maneuver for salvaging penumbra. We re-evaluated the previously described PROTECT (PRoximal balloon Occlusion TogEther with direCt Thrombus aspiration during stent retriever thrombectomy) Plus technique at a tertiary comprehensive stroke center. METHODS: We retrospectively analyzed all patients who underwent mechanical thrombectomy with stentrievers between May 2011 and April 2020. Patients were divided between those who underwent PROTECT Plus and those who did not (proximal balloon occlusion with stent retriever only). We compared the groups in terms of reperfusion, groin to reperfusion time, symptomatic intracranial hemorrhage (sICH), modified Rankin Scale (mRS) score at discharge. RESULTS: Within the study period, 167 (71.4%) PROTECT Plus and 67 (28.6%) non-PROTECT patients which met our inclusion criteria. There was no statistically significant difference in the number of patients with successful reperfusion (mTICI >2b) between the techniques (85.0% vs 82.1%; p = 0.58). The PROTECT Plus group had lower rates of mRS ≤2 at discharge (40.1% vs 57.6%; p = 0.016). The rate of sICH was comparable (p = 0.35) between the PROTECT Plus group (7.2%) and the non-PROTECT group (3.0%). CONCLUSION: The PROTECT Plus technique using a BGC, a distal reperfusion catheter and stent retriever is feasible for recanalization of large vessel occlusions. Successful recanalization, first-pass recanalization and complication rates are similar between PROTECT Plus and non-PROTECT stent retriever techniques. This study adds to an existing body of literature detailing techniques that use both a stent retriever and a distal reperfusion catheter to maximize recanalization for patients with large vessel occlusions.


Balloon Occlusion , Brain Ischemia , Stroke , Thrombosis , Humans , Brain Ischemia/therapy , Retrospective Studies , Stroke/surgery , Intracranial Hemorrhages , Thrombectomy/methods , Stents , Treatment Outcome
13.
J Neurointerv Surg ; 15(9): 844-850, 2023 Sep.
Article En | MEDLINE | ID: mdl-35868856

BACKGROUND: The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. METHODS: Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. RESULTS: The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. CONCLUSION: There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.


Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Treatment Outcome , Endovascular Procedures/methods , Retrospective Studies , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/surgery , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Embolization, Therapeutic/methods
14.
J Neurointerv Surg ; 15(6): 558-565, 2023 Jun.
Article En | MEDLINE | ID: mdl-35483912

BACKGROUND: The Woven EndoBridge (WEB) device has Food and Drug Administration approval for treatment of wide-necked intracranial bifurcation aneurysms. The WEB device has been shown to result in adequate occlusion in bifurcation aneurysms overall, but its usefulness in the individual bifurcation locations has been evaluated separately only in few case series, which were limited by small sample sizes. OBJECTIVE: To compare angiographic and clinical outcomes after treatment of bifurcation aneurysms at various locations, including anterior communicating artery (AComA), anterior cerebral artery (ACA) bifurcation distal to AComA, basilar tip, internal carotid artery (ICA) bifurcation, and middle cerebral artery (MCA) bifurcation aneurysms using the WEB device. METHODS: A retrospective cohort analysis was conducted at 22 academic institutions worldwide to compare treatment outcomes of patients with intracranial bifurcation aneurysms using the WEB device. Data include patient and aneurysm characteristics, procedural details, angiographic and functional outcomes, and complications. RESULTS: A total of 572 aneurysms were included. MCA (36%), AComA (35.7%), and basilar tip (18.9%) aneurysms were most common. The rate of adequate aneurysm occlusion was significantly higher for basilar tip (91.6%) and ICA bifurcation (96.7%) aneurysms and lower for ACA bifurcation (71.4%) and AComA (80.6%) aneurysms (p=0.04). CONCLUSION: To our knowledge, this is the most extensive study to date that compares the treatment of different intracranial bifurcation aneurysms using the WEB device. Basilar tip and ICA bifurcation aneurysms showed significantly higher rates of aneurysm occlusion than other locations.


Carotid Artery Diseases , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Retrospective Studies , Treatment Outcome , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Carotid Artery Diseases/therapy
15.
J Neurointerv Surg ; 15(5): 461-464, 2023 May.
Article En | MEDLINE | ID: mdl-35545426

BACKGROUND: The endovascular clip system (eCLIPs) is a novel device with both neck bridging and flow-diversion properties that make it suitable for the treatment of wide-necked bifurcation aneurysms. OBJECTIVE: To describe the clinical and radiologic outcomes of the eCLIPs device, including the first-in-man use of the latest version of the device. METHODS: This is a retrospective case series on all the wide-necked bifurcation aneurysms treated with the eCLIPs device in our center. The immediate and latest radiologic and clinical outcomes were assessed. RESULTS: The device was successfully implanted in 12 of 13 patients. After a median follow-up period of 19 months (range 3-64 months), all patients with available data (11/12) had a good radiologic outcome (modified Raymond-Roy classification scores of 1 or 2). Two patients (18.2%) underwent re-treatment with simple coiling through the device. One of these had a subarachnoid hemorrhage prior to re-treatment. There were no major complications (death or permanent neurologic deficits) associated with use of the device. CONCLUSION: Our series demonstrates occlusion rates that are similar to those of standard stent-assisted coiling and intrasaccular flow diversion for wide-necked bifurcation aneurysms. Larger registry-based studies are necessary to support our findings.


Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Treatment Outcome , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Retrospective Studies , Stents , Surgical Instruments
16.
Transl Stroke Res ; 14(4): 455-464, 2023 08.
Article En | MEDLINE | ID: mdl-36066701

Several studies have shown promising outcomes of the Woven EndoBridge (WEB) device for the treatment of wide-necked intracranial bifurcation aneurysms. This is a multicenter study attempts to explore the changes in trends and treatment outcomes over time for WEB embolization of intracranial aneurysms. The WorldWideWEB consortium is a retrospective multicenter collaboration of data from international centers spanning from January 2011 and June 2021, with no limitations on aneurysm location or rupture status. Both bifurcation and sidewall aneurysms were included. These patients were stratified based on treatment year into five treatment intervals: 2011-2015 (N = 66), 2016-2017 (N = 77), 2018 (N = 66), 2019 (N = 300), and 2020-2021 (N = 173). Patient characteristics and angiographic and clinical outcomes were compared between these time intervals. This study comprised 671 patients (median age 61.4 years; 71.2% female) with 682 intracranial aneurysms. Over time, we observed an increasing tendency to treat patients presenting with ruptured aneurysms and aneurysms with smaller neck, diameter, and dome widths. Furthermore, we observed a trend towards more off-label use of the WEB for sidewall aneurysms and increased adoption of transradial access for WEB deployment. Moreover, the proportion of patients with adequate WEB occlusion immediately and at last follow-up was significantly higher in more recent year cohorts, as well as lower rates of compaction and retreatment. Mortality and complications did not differ over time. This learning curve study suggests improved experience using the WEB for the treatment of intracranial aneurysms and has yielded higher rates of adequate occlusion over time.


Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Female , Middle Aged , Male , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Treatment Outcome , Retrospective Studies
18.
Radiology ; 304(2): 372-382, 2022 08.
Article En | MEDLINE | ID: mdl-35438564

Background The Woven EndoBridge (WEB) device was explicitly designed for wide-neck intracranial bifurcation aneurysms. Small-scale reports have evaluated the off-label use of WEB devices for the treatment of sidewall aneurysms, with promising outcomes. Purpose To compare the angiographic and clinical outcomes of the WEB device for the treatment of sidewall aneurysms compared with the treatment of bifurcation aneurysms. Materials and Methods A retrospective review of the WorldWideWEB Consortium, a synthesis of retrospective databases spanning from January 2011 to June 2021 at 22 academic institutions in North America, South America, and Europe, was performed to identify patients with intracranial aneurysms treated with the WEB device. Characteristics and outcomes were compared between bifurcation and sidewall aneurysms. Propensity score matching (PSM) was used to match by age, pretreatment ordinal modified Rankin Scale score, ruptured aneurysms, location of aneurysm, multiple aneurysms, prior treatment, neck, height, dome width, daughter sac, and incorporated branch. Results A total of 683 intracranial aneurysms were treated using the WEB device in 671 patients (median age, 61 years [IQR, 53-68 years]; male-to-female ratio, 1:2.5). Of those, 572 were bifurcation aneurysms and 111 were sidewall aneurysms. PSM was performed, resulting in 91 bifurcation and sidewall aneurysms pairs. No significant difference was observed in occlusion status at last follow-up, deployment success, or complication rates between the two groups. Conclusion No significantly different outcomes were observed following the off-label use of the Woven EndoBridge, or WEB, device for treatment of sidewall aneurysms compared with bifurcation aneurysms. The correct characterization of the sidewall aneurysm location, neck angle, and size is crucial for successful treatment and lower retreatment rate. © RSNA, 2022 See also the editorial by Hetts in this issue.


Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Aneurysm, Ruptured/therapy , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Female , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Male , Middle Aged , Retrospective Studies , Treatment Outcome
19.
Eur Radiol ; 32(9): 6126-6135, 2022 Sep.
Article En | MEDLINE | ID: mdl-35348859

OBJECTIVES: We evaluated whether clinicians agree in the detection of non-contrast CT markers of intracerebral hemorrhage (ICH) expansion. METHODS: From our local dataset, we randomly sampled 60 patients diagnosed with spontaneous ICH. Fifteen physicians and trainees (Stroke Neurology, Interventional and Diagnostic Neuroradiology) were trained to identify six density (Barras density, black hole, blend, hypodensity, fluid level, swirl) and three shape (Barras shape, island, satellite) expansion markers, using standardized definitions. Thirteen raters performed a second assessment. Inter- and intra-rater agreement were measured using Gwet's AC1, with a coefficient > 0.60 indicating substantial to almost perfect agreement. RESULTS: Almost perfect inter-rater agreement was observed for the swirl (0.85, 95% CI: 0.78-0.90) and fluid level (0.84, 95% CI: 0.76-0.90) markers, while the hypodensity (0.67, 95% CI: 0.56-0.76) and blend (0.62, 95% CI: 0.51-0.71) markers showed substantial agreement. Inter-rater agreement was otherwise moderate, and comparable between density and shape markers. Inter-rater agreement was lower for the three markers that require the rater to identify one specific axial slice (Barras density, Barras shape, island: 0.46, 95% CI: 0.40-0.52 versus others: 0.60, 95% CI: 0.56-0.63). Inter-observer agreement did not differ when stratified for raters' experience, hematoma location, volume, or anticoagulation status. Intra-rater agreement was substantial to almost perfect for all but the black hole marker. CONCLUSION: In a large sample of raters with different backgrounds and expertise levels, only four of nine non-contrast CT markers of ICH expansion showed substantial to almost perfect inter-rater agreement. KEY POINTS: • In a sample of 15 raters and 60 patients, only four of nine non-contrast CT markers of ICH expansion showed substantial to almost perfect inter-rater agreement (Gwet's AC1> 0.60). • Intra-rater agreement was substantial to almost perfect for eight of nine hematoma expansion markers. • Only the blend, fluid level, and swirl markers achieved substantial to almost perfect agreement across all three measures of reliability (inter-rater agreement, intra-rater agreement, agreement with the results of a reference reading).


Cerebral Hemorrhage , Stroke , Biomarkers , Cerebral Hemorrhage/diagnostic imaging , Hematoma/diagnostic imaging , Humans , Observer Variation , Reproducibility of Results , Tomography, X-Ray Computed
20.
J Neurosurg ; : 1-8, 2022 Feb 04.
Article En | MEDLINE | ID: mdl-35120326

OBJECTIVE: Transradial access (TRA) is commonly utilized in neurointerventional procedures. This study compared the technical and clinical outcomes of the use of TRA versus those of transfemoral access (TFA) for intracranial aneurysm embolization with the Woven EndoBridge (WEB) device. METHODS: This is a secondary analysis of the Worldwide WEB Consortium, which comprises multicenter data related to adult patients with intracranial aneurysms who were managed with the WEB device. These aneurysms were categorized into two groups: those who were treated with TRA or TFA. Patient and aneurysm characteristics and technical and clinical outcomes were compared between groups. Propensity score matching (PSM) was used to match groups according to the following baseline characteristics: age, sex, subarachnoid hemorrhage, aneurysm location, bifurcation aneurysm, aneurysm with incorporated branch, neck width, aspect ratio, dome width, and elapsed time since the last follow-up imaging evaluation. RESULTS: This study included 682 intracranial aneurysms (median [interquartile range] age 61.3 [53.0-68.0] years), of which 561 were treated with TFA and 121 with TRA. PSM resulted in 65 matched pairs. After PSM, both groups had similar characteristics, angiographic and functional outcomes, and rates of retreatment, thromboembolic and hemorrhagic complications, and death. TFA was associated with longer procedure length (median 96.5 minutes vs 72.0 minutes, p = 0.006) and fluoroscopy time (28.2 minutes vs 24.8 minutes, p = 0.037) as compared with TRA. On the other hand, deployment issues were more common in those treated with TRA, but none resulted in permanent complications. CONCLUSIONS: TRA has comparable outcomes, with shorter procedure and fluoroscopy time, to TFA for aneurysm embolization with the WEB device.

...