Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Gut ; 60(5): 658-65, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21266723

RESUMEN

OBJECTIVE: Reports on the accuracy of computed tomographic colonography (CTC) mainly involve series from expert institutions. The aims of this study were to assess CTC accuracy in a nationwide population and to relate it to radiologist performance in their initial training. DESIGN: Nationwide multicentre trial. SETTING: Twenty-eight radiologists, working in 26 mostly academic clinical units, were involved in the study after having attended a formal specialised 2-day training session on CTC. They worked through a training set of 52 cases with automatic feedback after an attempt at each case. PATIENTS: The study enrolled 845 patients with average and high risk of colorectal cancer, 737 of whom had both complete CTC and videocolonoscopy data, which constituted the dataset. INTERVENTIONS: Patients underwent same-day CTC followed by videocolonoscopy with segmental unblinding of CTC results. MAIN OUTCOME MEASURES: Sensitivity, specificity and positive and negative predictive values for detection of polyps ≥ 6 mm in per-patient and per-lesion analyses of CTC without computer-aided detection. RESULTS: Sensitivity, specificity and positive and negative predictive values for patients with polyps ≥ 6 mm were 69% (95% CI 61% to 77%), 91% (95% CI 89% to 94%), 67% (95% CI 59% to 74%) and 92% (95% CI 90% to 94%), respectively. Univariate analysis showed that the detection rate for polyps ≥ 6 mm was linked to neither radiologist case volume nor number of polyps, but was related to sensitivity achieved in the training set. Pooled sensitivity was 72% (95% CI 63% to 80%) versus 51% (95% CI 40% to 60%) for radiologists achieving above and below median sensitivity in the training set (61%), respectively. Multivariate analysis showed that sensitivity for polyps ≥ 6 mm in the training set was the only remaining significant predictive factor for subsequent performance. CONCLUSIONS: Radiologist sensitivity CTC for detection of polyps ≥ 6 mm in training was the sole independent predictor for subsequent sensitivity in detection of such polyps.


Asunto(s)
Competencia Clínica , Colonografía Tomográfica Computarizada/normas , Neoplasias Colorrectales/diagnóstico por imagen , Radiología/normas , Anciano , Pólipos del Colon/diagnóstico , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/patología , Colonografía Tomográfica Computarizada/métodos , Colonoscopía , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/patología , Educación Médica Continua/métodos , Métodos Epidemiológicos , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Sangre Oculta , Radiología/educación , Grabación en Video
3.
J Radiol ; 90(1 Pt 2): 109-22, 2009 Jan.
Artículo en Francés | MEDLINE | ID: mdl-19212279

RESUMEN

The recent introduction of high-end ultrasound equipment combined with recent contrast agents provides marked improvements in the characterization of focal liver lesions as previously reported by monocentric studies. The aim of the present study was to evaluate the diagnostic performance of Contrast-Enhanced Ultrasonography (CEUS) using SonoVue as well as its medico-economic value for characterization of focal liver lesions. These nodules were not characterized on previous CT or conventional sonography. This prospective multicentric study conducted in 15 French centres found diagnostic performances similar to those reported for CT and MRI, with a concordance rate of 84.5%, sensitivity greater than 80% and specificity greater than 90% for all types of lesions. Higher acceptance was found for CEUS compared to other imaging modalities. Economical assessment based on examination reimbursment and contrast agent cost showed a lower cost for contrast ultrasound versus CT and MRI. This French multicentric study confirmed the high diagnostic value of CEUS for focal liver lesion characterization and demonstrated a lower economical impact compared to other imaging modalities such as CT and MRI.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Hiperplasia Nodular Focal/diagnóstico por imagen , Hemangioma/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Fosfolípidos , Hexafluoruro de Azufre , Ultrasonografía/métodos , Adolescente , Adulto , Biopsia , Carcinoma Hepatocelular/diagnóstico , Intervalos de Confianza , Interpretación Estadística de Datos , Diagnóstico Diferencial , Hiperplasia Nodular Focal/diagnóstico , Francia , Humanos , Hígado/patología , Hepatopatías/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/secundario , Imagen por Resonancia Magnética/economía , Imagen por Resonancia Magnética/métodos , Selección de Paciente , Estudios Prospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/economía , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía/economía
4.
Fetal Diagn Ther ; 20(4): 262-5, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15980637

RESUMEN

We report the 1st confirmed case of an extradural hematoma diagnosed in utero by ultrasonography and magnetic resonance imaging at 31 weeks' gestation. No signs of intracranial hemorrhage were found. During pregnancy, the expecting mother suffered from sustained cough, and a blood sample test revealed acute pertussis. The presence of fetal hydrocephaly, brain parenchymal deviation, and other abnormalities suggested a poor outcome, and based on these findings pregnancy termination was recommended and carried out. Postmortem examination confirmed the diagnosis of an extradural hematoma in the posterior fossa.


Asunto(s)
Enfermedades Fetales/diagnóstico por imagen , Enfermedades Fetales/patología , Hematoma Epidural Craneal/diagnóstico por imagen , Hematoma Epidural Craneal/patología , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética , Embarazo , Pronóstico , Ultrasonografía Prenatal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA