Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
J Zoo Wildl Med ; 54(3): 455-463, 2023 Oct.
Article En | MEDLINE | ID: mdl-37817611

Sable antelope (Hippotragus niger), a large, dominant species, often require chemical immobilization for captive management. Despite several recorded protocols, limited objective or subjective data are available to guide chemical immobilization of this species. This study retrospectively compared immobilization drug combinations of carfentanil-xylazine (CX), thiafentanil-xylazine (TX), etorphine-xylazine (EX), carfentanil-acepromazine (CA), and butorphanol-azaperone-medetomidine (BAM) for healthy sable antelope at one institution. Clinically applicable physiologic measures, subjective ratings, and timing of anesthetic milestones of 161 events for 107 individuals revealed the following statistically significant findings (P < 0.05). Induction ratings were best for TX, highest degree of muscle relaxation occurred with BAM and TX, and anesthetic ratings were best for TX and EX. Time to recovery was longest and complications 2.56 times more likely with CX. Time to recumbency was shortest in TX. Heart rate was highest in CA and lowest in BAM. For immobilization procedures, this study suggests TX would be the preferred combination for H. niger. However, all drug combinations evaluated can be used successfully to immobilize H. niger, and certain combinations may be situationally preferred based on desired muscle relaxation, expected induction or recovery times, or anticipated procedure length.


Anesthetics , Antelopes , Mustelidae , Humans , Animals , Hypnotics and Sedatives/pharmacology , Xylazine/pharmacology , Retrospective Studies , Niger , Immobilization/veterinary , Immobilization/methods , Azaperone/pharmacology , Medetomidine/pharmacology , Butorphanol/pharmacology , Etorphine , Drug Combinations
2.
Disabil Rehabil Assist Technol ; 12(8): 852-856, 2017 11.
Article En | MEDLINE | ID: mdl-28100094

Wheelchair durability and maintenance condition are key factors of wheelchair function. Durability studies done with double drum and drop testers, although valuable, do not perfectly imitate conditions of use. Durability may be harvested from clinical records; however, these may be inconsistent because protocols for recording information differ from place to place. Wheelchair professionals with several years of experience often develop a good eye for wheelchair maintenance condition. The Wheelchair Components Questionnaire for Condition (WCQc) was developed as a professional report questionnaire to provide data specifically on the maintenance condition of a wheelchair. The goal of this study was to obtain preliminary test-retest reliability and internal consistency for the WCQc. Participants were a convenience sample of wheelchair professionals who self-reported more than two years' of wheelchair experience, and completed the WCQc on the same wheelchair twice. Results indicated preliminary reliability and internal consistency for domain related questions and the entire questionnaire. Implications for rehabilitation The WCQc, if administered routinely at regular intervals, can be used to monitor wheelchair condition and alert users and health professionals about the need for repair or replacement. The WCQc is not difficult to use, making early monitoring for wear or damage more feasible. The earlier a tool can detect need for maintenance, the higher likelihood that appropriate measures may be employed in a timely fashion to maximize the overall durability of wheelchairs and minimize clinical complications. Keeping wheelchairs appropriately maintained allows users to minimize effort expended when using them, and maximize their function. It also lowers the risk of injury due to component failure. When assessing groups of similar wheelchairs, organizations involved in funding wheelchairs can use data from the WCQc to make purchase decisions based on durability, and manufacturers can use WCQc data for responsive design change.


Equipment Failure , Health Personnel/standards , Maintenance , Surveys and Questionnaires/standards , Wheelchairs , Equipment Design , Humans , Reproducibility of Results
...