Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Chest ; 162(2): 297-308, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35248549

RESUMEN

BACKGROUND: Prostaglandin D2 receptor 2 (DP2) antagonists inhibit prostaglandin D2-induced effects, including recruitment and activation of cells driving asthma pathogenesis. However, challenges identifying target population and end points persist. RESEARCH QUESTION: What is the effect of the DP2 antagonist GB001 on asthma worsening in patients with moderate to severe eosinophilic asthma? STUDY DESIGN AND METHODS: In this phase IIb, randomized, double-blind, placebo-controlled, dose-ranging, parallel-group, multicenter study, GB001 or placebo was added to standard-of-care treatment in patients with moderate to severe asthma with a blood eosinophil count ≥ 250 cells/µL. Patients aged ≥ 18 years to < 75 years received one of four once-daily treatments (GB001 20 mg, 40 mg, or 60 mg or placebo). The primary end point was the proportion of patients who experienced asthma worsening by 24 weeks. Efficacy analyses were performed for the intention-to-treat population and safety analyses for patients who received at least one dose of study treatment. RESULTS: A total of 480 patients were treated. The ORs for asthma worsening for GB001 20 mg, 40 mg, and 60 mg vs placebo were 0.674 (95% CI, 0.398-1.142), 0.677 (95% CI, 0.399-1.149), and 0.651 (95% CI, 0.385-1.100), respectively. Analysis according to baseline blood eosinophil levels and/or fractional exhaled nitric oxide did not show greater treatment effects with higher values. Elevated liver aminotransferase levels and adverse events leading to discontinuation were more frequent for GB001 60 mg than with placebo, GB001 20 mg, and GB001 40 mg. INTERPRETATION: Although GB001 did not significantly reduce the odds of asthma worsening, reductions favoring GB001 were observed. Treatment effects were consistent regardless of high/low type 2 phenotype. The overall safety profile was acceptable, although GB001 60 mg was associated with risk of liver injury. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT03683576; URL: www. CLINICALTRIALS: gov.


Asunto(s)
Antiasmáticos , Asma , Eosinofilia Pulmonar , Antiasmáticos/uso terapéutico , Anticuerpos Monoclonales Humanizados/uso terapéutico , Asma/complicaciones , Progresión de la Enfermedad , Método Doble Ciego , Quimioterapia Combinada , Humanos , Prostaglandinas/uso terapéutico , Eosinofilia Pulmonar/inducido químicamente , Resultado del Tratamiento
2.
Clin Exp Allergy ; 50(2): 189-197, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31659803

RESUMEN

BACKGROUND: GB001 is an oral antagonist of the prostaglandin D2 receptor that may inhibit recruitment and activation of airway eosinophils, reducing airway inflammation. OBJECTIVE: To assess GB001 safety, efficacy and pharmacokinetics from a Phase 2 study and explore the association between type 2 biomarkers (fractional exhaled nitric oxide and blood eosinophils) and asthma control markers following GB001 administration. METHODS: A randomized, placebo-controlled, double-blind study evaluating 36 patients with mild-to-moderate atopic asthma. Patients receiving fluticasone propionate ≤500 mcg/day or equivalent were randomized (2:1) to GB001 (30 mg) or placebo once daily for 28 days. Safety, pharmacokinetics, forced expiratory volume in 1 second, asthma control questionnaire and rescue medication use were assessed. Clinical outcomes were analysed post hoc by baseline fractional exhaled nitric oxide (<35 and ≥35 ppb) and blood eosinophil (<250 and ≥250 cells/µL) subgroups. RESULTS: GB001 was well tolerated and rapidly absorbed with a 14.5-hour terminal half-life. Overall, GB001 demonstrated greater improvement relative to placebo in forced expiratory volume in 1 second at Day 28 (102 mL [95% CI: -110, 314]). Greater effects on forced expiratory volume in 1 second were observed in the high baseline fractional exhaled nitric oxide and blood eosinophil subgroups (207 mL [95% CI: -283, 698];133 mL [95% CI: -422, 687], respectively). These effects were observed as early as Day 2 (229 mL [95% CI: -170, 628]; 163 mL [95% CI: -223, 550] for the high baseline fractional exhaled nitric oxide and blood eosinophil subgroups, respectively) and were sustained through treatment completion. CONCLUSION AND CLINICAL RELEVANCE: GB001 was well tolerated, with the estimated half-life supporting once-daily (QD) dosing. GB001 may have a rapid and sustained effect on lung function, particularly in patients with type 2 phenotype. Further studies are needed to confirm these findings.


Asunto(s)
Antiasmáticos , Asma , Receptores Inmunológicos/antagonistas & inhibidores , Receptores de Prostaglandina/antagonistas & inhibidores , Adolescente , Adulto , Antiasmáticos/administración & dosificación , Antiasmáticos/efectos adversos , Antiasmáticos/farmacocinética , Asma/tratamiento farmacológico , Asma/inmunología , Asma/patología , Biomarcadores , Pruebas Respiratorias , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Receptores Inmunológicos/inmunología , Receptores de Prostaglandina/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...