Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Dermatol Surg ; 50(1): 62-68, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37815475

RESUMEN

BACKGROUND: Needle-free hyaluronic acid (HA) jet injectors are gaining popularity for rejuvenation treatment. The devices are widely available online and are used for self-injection or in beauty salons by nonphysicians. However, little is known about their performance and safety. OBJECTIVE: To explore the injection efficiency and cutaneous biodistribution patterns administered with home-use compared with medical jet injectors and to assess safety aspects. MATERIALS AND METHODS: The authors injected HA into ex vivo human skin with 4 home-use and 2 medical injectors. The intracutaneous dose of HA was calculated, and the cutaneous biodistribution of HA was assessed using a 3-dimensional Fluorescent Imaging Cryomicrotome System (3D-FICS). Safety aspects were evaluated based on the presence of a manual, CE (conformité européenne) mark, and sterility. RESULTS: The intracutaneous dose delivered by the home-use injectors was markedly lower compared with the medical injectors. 3D imaging for home-use injectors showed superficial epidermal distribution with low distribution volumes. For medical injectors, volumes were substantially larger and mainly middermal. All evaluated safety aspects were lacking. CONCLUSION: Results of this study suggest that the specific combinations of home-use injectors and HA used in this study are unreliable and unsafe, which casts doubts on the performance of these treatments in general.


Asunto(s)
Ácido Hialurónico , Piel , Humanos , Ácido Hialurónico/efectos adversos , Ácido Hialurónico/metabolismo , Inyecciones a Chorro/métodos , Distribución Tisular , Piel/metabolismo , Administración Cutánea
2.
J Biomed Opt ; 22(8): 1-9, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28822141

RESUMEN

Patient morbidity and mortality due to hemodynamic complications are a major problem in surgery. Optical techniques can image blood flow in real-time and high-resolution, thereby enabling perfusion monitoring intraoperatively. We tested the feasibility and validity of laser speckle contrast imaging (LSCI), optical coherence tomography (OCT), and sidestream dark-field microscopy (SDF) for perfusion diagnostics in a phantom model using whole blood. Microvessels with diameters of 50, 100, and 400 µm were constructed in a scattering phantom. Perfusion was simulated by pumping heparinized human whole blood at five velocities (0 to 20 mm/s). Vessel diameter and blood flow velocity were assessed with LSCI, OCT, and SDF. Quantification of vessel diameter was feasible with OCT and SDF. LSCI could only visualize the 400-µm vessel, perfusion units scaled nonlinearly with blood velocity. OCT could assess blood flow velocity in terms of inverse OCT speckle decorrelation time. SDF was not feasible to measure blood flow; however, for diluted blood the measurements were linear with the input velocity up to 1 mm/s. LSCI, OCT, and SDF were feasible to visualize blood flow. Validated blood flow velocity measurements intraoperatively in the desired parameter (mL·min-1·g-1) remain challenging.


Asunto(s)
Microscopía/métodos , Imagen Óptica/métodos , Tomografía de Coherencia Óptica/métodos , Velocidad del Flujo Sanguíneo , Humanos , Imagen de Perfusión , Flujo Sanguíneo Regional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA