Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Sports Act Living ; 6: 1282214, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38344127

RESUMEN

Introduction: The application of muscle force is a determinant of football success as it is inherent to the motor control and sport. The aims of this study are: (1) to describe force variables Isometric Maximal Force (IMF), Concentric Peak Force (CPPF), and Dynamic Strength Index (DSI) in football goalkeepers from different age groups; (2) to compare these variables' behavior between those groups. Methods: The sample was formed by 19 youth players (15.97 ± 1.55 years old) from a first-division Brazilian football team. The CPPF and IMF variables were obtained through the Countermovement jump and isometric squat tests, respectively. For data collection, a force plate (Cefise, Brazil) was used with an acquisition frequency of 600 Hz and mono-axial. The DSI was calculated using the ratio between CPPF and IMF. For data analysis, the sample was separated into clusters by age. After the grouping, a descriptive analysis of the data and a comparison between the groups with p < 0.05. Results: The sample was grouped into three groups (GA, GB, and GC) and one of the individuals did not enter the group, totaling 18 individuals in the analyzed sample. The comparison between the ages of the groups showed a significant difference and small and moderate effect size (ES), validating the cluster strategy. The CPPF and IMF variables showed increased values according to chronological age. CPPF showed a significant difference between GA-GB, (ES = very large) GA-GC (ES = very large), and GB-GC (ES = moderate). The IMF variable had significant differences between GA-GB (ES = moderate) and GA-GC (ES = very large). However, DSI showed significant differences only between GA GB (ES = small) and GB-GC (ES = very large). Conclusions: The CPPF and IMF variables had constant increases and distinct values with an increase according to age, and this did not occur for DSI. The difference between CPPF and IMF compared to DSI bring to light the variability in dynamics and proportionality between muscular force in the concentric phase and maximal force in the isometric regime during the developmental process over chronological age in soccer goalkeepers.

2.
Physiol Meas ; 36(6): 1245-59, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26009486

RESUMEN

Electrical impedance tomography (EIT) could provide images of fast neural activity in the adult human brain with a resolution of 1 ms and 1 mm by imaging impedance changes which occur as ion channels open during neuronal depolarization. The largest changes occur at dc and decrease rapidly over 100 Hz. Evoked potentials occur in this bandwidth and may cause artefactual apparent impedance changes if altered by the impedance measuring current. These were characterized during the compound action potential in the walking leg nerves of Cancer pagurus, placed on Ag/AgCl hook electrodes, to identify how to avoid artefactual changes during brain EIT. Artefact-free impedance changes (δZ) decreased with frequency from -0.045 ± 0.01% at 225 Hz to -0.02 ± 0.01% at 1025 Hz (mean ± 1 SD, n = 24 in 12 nerves) which matched changes predicted by a finite element model. Artefactual δZ reached c.300% and 50% of the genuine membrane impedance change at 225 Hz and 600 Hz respectively but decreased with frequency of the applied current and was negligible above 1 kHz. The proportional amplitude (δZ (%)) of the artefact did not vary significantly with the amplitude of injected current of 5-20 µA pp. but decreased significantly from -0.09 ± 0.024 to -0.03 ± 0.023% with phase of 0 to 45°. For fast neural EIT of evoked activity in the brain, artefacts may arise with applied current of >10 µA. Independence of δZ with respect to phase but not the amplitude of applied current controls for them; they can be minimized by randomizing the phase of the applied measuring current and excluded by recording at >1 kHz.


Asunto(s)
Potenciales de Acción , Artefactos , Encéfalo/citología , Tomografía/métodos , Membrana Celular/metabolismo , Capacidad Eléctrica , Impedancia Eléctrica , Electrodos , Tomografía/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...