Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Agric Food Chem ; 69(19): 5528-5535, 2021 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-33970002

RESUMEN

This work involved a systematic comparison between serum and urine for the monitoring of anabolic androgenic steroids in livestock. Incurred samples were collected over 120 days from crossbred steers treated with intramuscular injections containing boldenone undecylenate. Independent high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) methods were used for the assessment of the respective detection windows, which were larger for serum samples. Both matrices presented adequate performance in terms of long-term stability, assessed using an isochronous approach during 196 days at -20 °C and for five freeze-thaw cycles. The effectiveness of the enzymatic hydrolysis reaction using Helix pomatia juice was also compared. The calculated concentrations in serum samples were not statistically influenced by the deconjugation reaction. On the other hand, urine hydrolysis conditions were studied using a 33 Box-Behnken Design, in which a central point condition led to a satisfactory deconjugation performance. It could be observed that serum exhibited equivalent or better performance than urine for most of the evaluated criteria; thus, its inclusion in the regulatory analysis of boldenone in cattle is supported.


Asunto(s)
Anabolizantes , Espectrometría de Masas en Tándem , Animales , Bovinos , Cromatografía Líquida de Alta Presión , Hidrólisis , Testosterona/análogos & derivados
2.
J Agric Food Chem ; 66(32): 8630-8638, 2018 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-30020779

RESUMEN

In this work, a GC-MS/MS method was developed for the determination of anabolic-agent residues in bovine urine. The optimized sample preparation was as follows: enzymatic hydrolysis by ß-glucuronidase-sulfatase enzyme from Helix pomatia for 16 h at 37.5 °C, liquid-liquid extraction with diethyl ether, solid-phase extraction with HLB and aminopropylsilane cartridges, and microwave-assisted derivatization using 25 µL of MSTFA/NH4I/ethanethiol and full microwave power for 2 min. The method was validated according to Decision 657/2002/EC, Codex Alimentarius, and Manual da Garantia da Qualidade Analítica guidelines. The acceptability criteria for quantitative analysis were met for α-ethinylestradiol, α-nandrolone, ß-estradiol, ß-zearalanol, ß-zearalenol, drostanolone, ethisterone, dienestrol, diethylstilbestrol, hexestrol, megestrol, methyltestosterone, and zearalenone. The analytes α-zearalenol, α-zearalanol, and norethandrolone were validated for qualitative analysis.


Asunto(s)
Anabolizantes/orina , Bovinos/orina , Residuos de Medicamentos/análisis , Cromatografía de Gases y Espectrometría de Masas/métodos , Lactonas/orina , Esteroides/orina , Estilbenos/orina , Espectrometría de Masas en Tándem/métodos , Animales , Límite de Detección , Microondas
3.
Artículo en Inglés | MEDLINE | ID: mdl-22325002

RESUMEN

A quantitative liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous analyses of malachite green (MG), crystal violet (CV) and its major metabolites, leucomalachite green (LMG) and leucocrystal violet (LCV) residues in fish and shrimp samples has been validated. Fish and shrimp samples were extracted with citrate buffer/acetonitrile, and the extracts were purified on strong cation-exchange (SCX) solid-phase extraction (SPE) cartridge. After conversion of LMG into MG using a post column oxidation reactor containing lead (IV) oxide (PbO(2)), the effluents were analysed. Residues were analysed using positive-ion electrospray ionisation (ESI). Identification and quantification of analytes were based on the ion transitions monitored by multiple reaction monitoring (MRM). Validation of the method was carried out in accordance with the Decision 2002/657/EC, which establishes criteria and procedures for the validation of methods. The following parameters were determined: decision limit (CCα), detection capability (CCß), linearity, accuracy, precision, selectivity, specificity and matrix effect. The decision limits (CCα) for MG, LMG, CV and LCV were 0.164, 0.161, 0.248 and 0.860 µg kg(-1). The respective detection capabilities (CCß) were 0.222, 0.218, 0.355 and 1.162 µg kg(-1). Typical recoveries (intermediate precision) in shrimp, for MG, CV, LMG and LCV for 2.0 µg kg(-1) level fortified samples using the optimised procedure were in the range 69%, 97%, 80.3% and 71.8%, respectively. The findings demonstrate the suitability of the method to detect simultaneously MG, CV and its metabolite (LMG and LCV) in fish and shrimp.


Asunto(s)
Cromatografía Liquida/métodos , Residuos de Medicamentos/análisis , Contaminación de Alimentos/análisis , Alimentos Marinos/análisis , Espectrometría de Masas en Tándem/métodos , Animales , Brasil , Peces , Violeta de Genciana/análisis , Límite de Detección , Penaeidae , Colorantes de Rosanilina/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Drogas Veterinarias/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA