Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
2.
Magn Reson Imaging ; 76: 108-115, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33220450

RESUMEN

Brain vascular damage accumulate in aging and often manifest as white matter hyperintensities (WMHs) on MRI. Despite increased interest in automated methods to segment WMHs, a gold standard has not been achieved and their longitudinal reproducibility has been poorly investigated. The aim of present work is to evaluate accuracy and reproducibility of two freely available segmentation algorithms. A harmonized MRI protocol was implemented in 3T-scanners across 13 European sites, each scanning five volunteers twice (test-retest) using 2D-FLAIR. Automated segmentation was performed using Lesion segmentation tool algorithms (LST): the Lesion growth algorithm (LGA) in SPM8 and 12 and the Lesion prediction algorithm (LPA). To assess reproducibility, we applied the LST longitudinal pipeline to the LGA and LPA outputs for both the test and retest scans. We evaluated volumetric and spatial accuracy comparing LGA and LPA with manual tracing, and for reproducibility the test versus retest. Median volume difference between automated WMH and manual segmentations (mL) was -0.22[IQR = 0.50] for LGA-SPM8, -0.12[0.57] for LGA-SPM12, -0.09[0.53] for LPA, while the spatial accuracy (Dice Coefficient) was 0.29[0.31], 0.33[0.26] and 0.41[0.23], respectively. The reproducibility analysis showed a median reproducibility error of 20%[IQR = 41] for LGA-SPM8, 14% [31] for LGA-SPM12 and 10% [27] with the LPA cross-sectional pipeline. Applying the LST longitudinal pipeline, the reproducibility errors were considerably reduced (LGA: 0%[IQR = 0], p < 0.001; LPA: 0% [3], p < 0.001) compared to those derived using the cross-sectional algorithms. The DC using the longitudinal pipeline was excellent (median = 1) for LGA [IQR = 0] and LPA [0.02]. LST algorithms showed moderate accuracy and good reproducibility. Therefore, it can be used as a reliable cross-sectional and longitudinal tool in multi-site studies.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Sustancia Blanca/diagnóstico por imagen , Adulto , Envejecimiento , Algoritmos , Automatización , Estudios Transversales , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sustancia Blanca/patología
3.
Neuroimage ; 218: 116932, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32416226

RESUMEN

BACKGROUND: The amygdala and the hippocampus are two limbic structures that play a critical role in cognition and behavior, however their manual segmentation and that of their smaller nuclei/subfields in multicenter datasets is time consuming and difficult due to the low contrast of standard MRI. Here, we assessed the reliability of the automated segmentation of amygdalar nuclei and hippocampal subfields across sites and vendors using FreeSurfer in two independent cohorts of older and younger healthy adults. METHODS: Sixty-five healthy older (cohort 1) and 68 younger subjects (cohort 2), from the PharmaCog and CoRR consortia, underwent repeated 3D-T1 MRI (interval 1-90 days). Segmentation was performed using FreeSurfer v6.0. Reliability was assessed using volume reproducibility error (ε) and spatial overlapping coefficient (DICE) between test and retest session. RESULTS: Significant MRI site and vendor effects (p â€‹< â€‹.05) were found in a few subfields/nuclei for the ε, while extensive effects were found for the DICE score of most subfields/nuclei. Reliability was strongly influenced by volume, as ε correlated negatively and DICE correlated positively with volume size of structures (absolute value of Spearman's r correlations >0.43, p â€‹< â€‹1.39E-36). In particular, volumes larger than 200 â€‹mm3 (for amygdalar nuclei) and 300 â€‹mm3 (for hippocampal subfields, except for molecular layer) had the best test-retest reproducibility (ε â€‹< â€‹5% and DICE â€‹> â€‹0.80). CONCLUSION: Our results support the use of volumetric measures of larger amygdalar nuclei and hippocampal subfields in multisite MRI studies. These measures could be useful for disease tracking and assessment of efficacy in drug trials.


Asunto(s)
Amígdala del Cerebelo/anatomía & histología , Hipocampo/anatomía & histología , Procesamiento de Imagen Asistido por Computador/normas , Neuroimagen/normas , Programas Informáticos , Adulto , Anciano , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Masculino , Persona de Mediana Edad , Neuroimagen/métodos , Reproducibilidad de los Resultados
4.
Injury ; 50(8): 1464-1469, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31387739

RESUMEN

PURPOSE: The triangular fibrocartilage complex is one of the most important stabilizers of the wrist and a defect in its anatomical structure is a possible cause of ulnar sided wrist pain. The aim of this study is to compare the diagnostic accuracy between conventional MRI and MR arthrography (MRA) in the depiction of triangular fibrocartilage complex (TFCC) tears. METHODS-MATERIALS: A total of 60 patients with clinical findings that suggested TFCC tears underwent wrist MRI and MRA. All the MRI and MRA results were compared with the arthroscopic findings. RESULTS: 40 tears were confirmed by arthroscopy. 38/40 tears were identified by MRA while MRI identified 26/40 tears. There were also 8 false positives and 13 false negative results identified by MRI. Two false negative results were identified by MRA. No false positive results were identified. CONCLUSION: MR arthrography is more sensitive and specific method in terms of the diagnosis of TFCC tears compared to conventional wrist MRI. There was no difference in the diagnostic accuracy between wrist arthroscopy and MRA.


Asunto(s)
Artrografía , Ligamentos/diagnóstico por imagen , Imagen por Resonancia Magnética , Fibrocartílago Triangular/diagnóstico por imagen , Traumatismos de la Muñeca/diagnóstico por imagen , Adolescente , Adulto , Artroscopía , Femenino , Humanos , Ligamentos/lesiones , Ligamentos/patología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Fibrocartílago Triangular/lesiones , Fibrocartílago Triangular/patología , Traumatismos de la Muñeca/patología , Adulto Joven
5.
IEEE J Biomed Health Inform ; 23(3): 923-930, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30561355

RESUMEN

Deep learning (DL) architectures have opened new horizons in medical image analysis attaining unprecedented performance in tasks such as tissue classification and segmentation as well as prediction of several clinical outcomes. In this paper, we propose and evaluate a novel three-dimensional (3-D) convolutional neural network (CNN) designed for tissue classification in medical imaging and applied for discriminating between primary and metastatic liver tumors from diffusion weighted MRI (DW-MRI) data. The proposed network consists of four consecutive strided 3-D convolutional layers with 3 × 3 × 3 kernel size and rectified linear unit (ReLU) as activation function, followed by a fully connected layer with 2048 neurons and a Softmax layer for binary classification. A dataset comprising 130 DW-MRI scans was used for the training and validation of the network. To the best of our knowledge this is the first DL solution for the specific clinical problem and the first 3-D CNN for cancer classification operating directly on whole 3-D tomographic data without the need of any preprocessing step such as region cropping, annotating, or detecting regions of interest. The classification performance results, 83% (3-D) versus 69.6% and 65.2% (2-D), demonstrated significant tissue classification accuracy improvement compared to two 2-D CNNs of different architectures also designed for the specific clinical problem with the same dataset. These results suggest that the proposed 3-D CNN architecture can bring significant benefit in DW-MRI liver discrimination and potentially, in numerous other tissue classification problems based on tomographic data, especially in size-limited, disease-specific clinical datasets.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Neoplasias Hepáticas , Imagen por Resonancia Magnética/métodos , Redes Neurales de la Computación , Aprendizaje Profundo , Humanos , Neoplasias Hepáticas/clasificación , Neoplasias Hepáticas/diagnóstico por imagen
6.
Hum Brain Mapp ; 38(1): 12-26, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27519630

RESUMEN

Free water elimination (FWE) in brain diffusion MRI has been shown to improve tissue specificity in human white matter characterization both in health and in disease. Relative to the classical diffusion tensor imaging (DTI) model, FWE is also expected to increase sensitivity to microstructural changes in longitudinal studies. However, it is not clear if these two models differ in their test-retest reproducibility. This study compares a bi-tensor model for FWE with DTI by extending a previous longitudinal-reproducibility 3T multisite study (10 sites, 7 different scanner models) of 50 healthy elderly participants (55-80 years old) scanned in two sessions at least 1 week apart. We computed the reproducibility of commonly used DTI metrics (FA: fractional anisotropy, MD: mean diffusivity, RD: radial diffusivity, and AXD: axial diffusivity), derived either using a DTI model or a FWE model. The DTI metrics were evaluated over 48 white-matter regions of the JHU-ICBM-DTI-81 white-matter labels atlas, and reproducibility errors were assessed. We found that relative to the DTI model, FWE significantly reduced reproducibility errors in most areas tested. In particular, for the FA and MD metrics, there was an average reduction of approximately 1% in the reproducibility error. The reproducibility scores did not significantly differ across sites. This study shows that FWE improves sensitivity and is thus promising for clinical applications, with the potential to identify more subtle changes. The increased reproducibility allows for smaller sample size or shorter trials in studies evaluating biomarkers of disease progression or treatment effects. Hum Brain Mapp 38:12-26, 2017. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Envejecimiento , Encéfalo/diagnóstico por imagen , Imagen de Difusión Tensora , Agua/metabolismo , Anciano , Anciano de 80 o más Años , Anisotropía , Femenino , Voluntarios Sanos , Humanos , Imagenología Tridimensional , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sustancia Blanca/diagnóstico por imagen
7.
J Cancer ; 7(6): 730-5, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27076855

RESUMEN

PURPOSE: Diffusion Weighted Imaging is an established diagnostic tool for accurate differential diagnosis between benign and malignant liver lesions. The aim of our study was to evaluate the role of Histogram Analysis of ADC quantification in determining the histological diagnosis as well as the grade of malignant liver tumours. To our knowledge, there is no study evaluating the role of Histogram Analysis of ADC quantification in determining the histological diagnosis as well as the grade of malignant liver tumours. METHODS: During five years, 115 patients with known liver lesions underwent Diffusion Weighted Imaging in 3Tesla MR scanner prior to core needle biopsy. Histogram analyses of ADC in regions of interest were drawn and were correlated with biopsy histological diagnosis and grading. RESULTS: Histogram analysis of ADC values shows that 5th and 30th percentile parameters have statistically significant potency of discrimination between primary and secondary lesions groups (p values 0.0036 and 0.0125 respectively). Skewness of the histogram can help discriminate between good and poor differentiated (p value 0.17). Discrimination between primary malignancy site in metastases failed for the present number of patients in each subgroup. CONCLUSION: Statistical parameters reflecting the shape of the left side of the ADC histogram can be useful for discriminating between primary and secondary lesions and also between well differentiated versus moderate or poor. For the secondary malignancies, they failed to predict the original site of tumour.

8.
Hum Brain Mapp ; 37(6): 2114-32, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26990928

RESUMEN

Understanding how to reduce the influence of physiological noise in resting state fMRI data is important for the interpretation of functional brain connectivity. Limited data is currently available to assess the performance of physiological noise correction techniques, in particular when evaluating longitudinal changes in the default mode network (DMN) of healthy elderly participants. In this 3T harmonized multisite fMRI study, we investigated how different retrospective physiological noise correction (rPNC) methods influence the within-site test-retest reliability and the across-site reproducibility consistency of DMN-derived measurements across 13 MRI sites. Elderly participants were scanned twice at least a week apart (five participants per site). The rPNC methods were: none (NPC), Tissue-based regression, PESTICA and FSL-FIX. The DMN at the single subject level was robustly identified using ICA methods in all rPNC conditions. The methods significantly affected the mean z-scores and, albeit less markedly, the cluster-size in the DMN; in particular, FSL-FIX tended to increase the DMN z-scores compared to others. Within-site test-retest reliability was consistent across sites, with no differences across rPNC methods. The absolute percent errors were in the range of 5-11% for DMN z-scores and cluster-size reliability. DMN pattern overlap was in the range 60-65%. In particular, no rPNC method showed a significant reliability improvement relative to NPC. However, FSL-FIX and Tissue-based physiological correction methods showed both similar and significant improvements of reproducibility consistency across the consortium (ICC = 0.67) for the DMN z-scores relative to NPC. Overall these findings support the use of rPNC methods like tissue-based or FSL-FIX to characterize multisite longitudinal changes of intrinsic functional connectivity. Hum Brain Mapp 37:2114-2132, 2016. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Mapeo Encefálico , Encéfalo/fisiología , Imagen por Resonancia Magnética , Anciano , Mapeo Encefálico/métodos , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Vías Nerviosas/fisiología , Análisis de Regresión , Reproducibilidad de los Resultados , Descanso , Estudios Retrospectivos
9.
Neuroimage ; 124(Pt A): 442-454, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26163799

RESUMEN

To date, limited data are available regarding the inter-site consistency of test-retest reproducibility of functional connectivity measurements, in particular with regard to integrity of the Default Mode Network (DMN) in elderly participants. We implemented a harmonized resting-state fMRI protocol on 13 clinical scanners at 3.0T using vendor-provided sequences. Each site scanned a group of 5 healthy elderly participants twice, at least a week apart. We evaluated inter-site differences and test-retest reproducibility of both temporal signal-to-noise ratio (tSNR) and functional connectivity measurements derived from: i) seed-based analysis (SBA) with seed in the posterior cingulate cortex (PCC), ii) group independent component analysis (ICA) separately for each site (site ICA), and iii) consortium ICA, with group ICA across the whole consortium. Despite protocol harmonization, significant and quantitatively important inter-site differences remained in the tSNR of resting-state fMRI data; these were plausibly driven by hardware and pulse sequence differences across scanners which could not be harmonized. Nevertheless, the tSNR test-retest reproducibility in the consortium was high (ICC=0.81). The DMN was consistently extracted across all sites and analysis methods. While significant inter-site differences in connectivity scores were found, there were no differences in the associated test-retest error. Overall, ICA measurements were more reliable than PCC-SBA, with site ICA showing higher reproducibility than consortium ICA. Across the DMN nodes, the PCC yielded the most reliable measurements (≈4% test-retest error, ICC=0.85), the medial frontal cortex the least reliable (≈12%, ICC=0.82) and the lateral parietal cortices were in between (site ICA). Altogether these findings support usage of harmonized multisite studies of resting-state functional connectivity to characterize longitudinal effects in studies that assess disease progression and treatment response.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/fisiología , Giro del Cíngulo/fisiología , Imagen por Resonancia Magnética/métodos , Anciano , Anciano de 80 o más Años , Artefactos , Interpretación Estadística de Datos , Humanos , Estudios Longitudinales , Persona de Mediana Edad , Vías Nerviosas/fisiología , Reproducibilidad de los Resultados , Relación Señal-Ruido
10.
Hum Brain Mapp ; 36(9): 3516-27, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26043939

RESUMEN

Recently, there has been an increased interest in the use of automatically segmented subfields of the human hippocampal formation derived from magnetic resonance imaging (MRI). However, little is known about the test-retest reproducibility of such measures, particularly in the context of multisite studies. Here, we report the reproducibility of automated Freesurfer hippocampal subfields segmentations in 65 healthy elderly enrolled in a consortium of 13 3T MRI sites (five subjects per site). Participants were scanned in two sessions (test and retest) at least one week apart. Each session included two anatomical 3D T1 MRI acquisitions harmonized in the consortium. We evaluated the test-retest reproducibility of subfields segmentation (i) to assess the effects of averaging two within-session T1 images and (ii) to compare subfields with whole hippocampus volume and spatial reliability. We found that within-session averaging of two T1 images significantly improved the reproducibility of all hippocampal subfields but not that of the whole hippocampus. Volumetric and spatial reproducibility across MRI sites were very good for the whole hippocampus, CA2-3, CA4-dentate gyrus (DG), subiculum (reproducibility error∼2% and DICE > 0.90), good for CA1 and presubiculum (reproducibility error ∼ 5% and DICE ∼ 0.90), and poorer for fimbria and hippocampal fissure (reproducibility error ∼ 15% and DICE < 0.80). Spearman's correlations confirmed that test-retest reproducibility improved with volume size. Despite considerable differences of MRI scanner configurations, we found consistent hippocampal subfields volumes estimation. CA2-3, CA4-DG, and sub-CA1 (subiculum, presubiculum, and CA1 pooled together) gave test-retest reproducibility similar to the whole hippocampus. Our findings suggest that the larger hippocampal subfields volume may be reliable longitudinal markers in multisite studies.


Asunto(s)
Envejecimiento/patología , Hipocampo/anatomía & histología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Anciano , Europa (Continente) , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Reproducibilidad de los Resultados , Programas Informáticos
11.
Ann Gastroenterol ; 28(1): 118-123, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25608776

RESUMEN

BACKGROUND: Limited data are available regarding the role of magnetic resonance imaging (MRI), particularly the new generation 3 Tesla technology, and especially diffusion-weighted imaging (DWI) in predicting liver fibrosis. The aim of our pilot study was to assess the clinical performance of the apparent diffusion coefficient (ADC) of liver parenchyma for the assessment of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). METHODS: 18 patients with biopsy-proven NAFLD underwent DWI with 3 Tesla MRI. DWI was performed with single-shot echo-planar technique at b values of 0-500 and 0-1000 s/mm2. ADC was measured in four locations in the liver and the mean ADC value was used for analysis. Staging of fibrosis was performed according to the METAVIR system. RESULTS: The median age of patients was 52 years (range 23-73). The distribution of patients in different fibrosis stages was: 0 (n=1), 1 (n=7), 2 (n=1), 3 (n=5), 4 (n=4). Fibrosis stage was poorly associated with ADC at b value of 0-500 s/mm2 (r= -0.30, P=0.27). However it was significantly associated with ADC at b value of 0-1000 s/mm2 (r= -0.57, P=0.01). For this b value (0-1000 s/mm2) the area under receiver-operating characteristic curve was 0.93 for fibrosis stage ≥3 and the optimal ADC cut-off value was 1.16 ×10-3 mm2/s. CONCLUSION: 3 Tesla DWI can possibly predict the presence of advanced fibrosis in patients with NAFLD.

12.
Surg Oncol Clin N Am ; 23(4): 629-84, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25246045

RESUMEN

Neuroimaging plays a crucial role in diagnosis of brain tumors and in the decision-making process for therapy. Functional imaging techniques can reflect cellular density (diffusion imaging), capillary density (perfusion techniques), and tissue biochemistry (magnetic resonance [MR] spectroscopy). In addition, cortical activation imaging (functional MR imaging) can identify various loci of eloquent cerebral cortical function. Combining these new tools can increase diagnostic specificity and confidence. Familiarity with conventional and advanced imaging findings facilitates accurate diagnosis, differentiation from other processes, and optimal patient treatment. This article is a practical synopsis of pathologic, clinical, and imaging spectra of most common brain tumors.


Asunto(s)
Neoplasias Encefálicas/diagnóstico , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Tumores Neuroectodérmicos/diagnóstico , Neuroimagen/métodos , Neoplasias Encefálicas/epidemiología , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/terapia , Medios de Contraste , Imagen de Difusión por Resonancia Magnética , Humanos , Imagen Multimodal , Tumores Neuroectodérmicos/epidemiología , Tumores Neuroectodérmicos/terapia , Imagen de Perfusión , Tomografía Computarizada por Rayos X
13.
Neuroimage ; 101: 390-403, 2014 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-25026156

RESUMEN

Large-scale longitudinal neuroimaging studies with diffusion imaging techniques are necessary to test and validate models of white matter neurophysiological processes that change in time, both in healthy and diseased brains. The predictive power of such longitudinal models will always be limited by the reproducibility of repeated measures acquired during different sessions. At present, there is limited quantitative knowledge about the across-session reproducibility of standard diffusion metrics in 3T multi-centric studies on subjects in stable conditions, in particular when using tract based spatial statistics and with elderly people. In this study we implemented a multi-site brain diffusion protocol in 10 clinical 3T MRI sites distributed across 4 countries in Europe (Italy, Germany, France and Greece) using vendor provided sequences from Siemens (Allegra, Trio Tim, Verio, Skyra, Biograph mMR), Philips (Achieva) and GE (HDxt) scanners. We acquired DTI data (2 × 2 × 2 mm(3), b = 700 s/mm(2), 5 b0 and 30 diffusion weighted volumes) of a group of healthy stable elderly subjects (5 subjects per site) in two separate sessions at least a week apart. For each subject and session four scalar diffusion metrics were considered: fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD) and axial (AD) diffusivity. The diffusion metrics from multiple subjects and sessions at each site were aligned to their common white matter skeleton using tract-based spatial statistics. The reproducibility at each MRI site was examined by looking at group averages of absolute changes relative to the mean (%) on various parameters: i) reproducibility of the signal-to-noise ratio (SNR) of the b0 images in centrum semiovale, ii) full brain test-retest differences of the diffusion metric maps on the white matter skeleton, iii) reproducibility of the diffusion metrics on atlas-based white matter ROIs on the white matter skeleton. Despite the differences of MRI scanner configurations across sites (vendors, models, RF coils and acquisition sequences) we found good and consistent test-retest reproducibility. White matter b0 SNR reproducibility was on average 7 ± 1% with no significant MRI site effects. Whole brain analysis resulted in no significant test-retest differences at any of the sites with any of the DTI metrics. The atlas-based ROI analysis showed that the mean reproducibility errors largely remained in the 2-4% range for FA and AD and 2-6% for MD and RD, averaged across ROIs. Our results show reproducibility values comparable to those reported in studies using a smaller number of MRI scanners, slightly different DTI protocols and mostly younger populations. We therefore show that the acquisition and analysis protocols used are appropriate for multi-site experimental scenarios.


Asunto(s)
Imagen de Difusión Tensora/normas , Sustancia Blanca/anatomía & histología , Anciano , Anciano de 80 o más Años , Imagen de Difusión Tensora/instrumentación , Imagen de Difusión Tensora/métodos , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
14.
Insights Imaging ; 5(3): 387-402, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24789122

RESUMEN

BACKGROUND: Pilocytic astrocytoma can be challenging to diagnose. METHODS: Its clinical presentations can differ, directly related to its size and location, and are relatively unreliable. Similarly, imaging findings also vary with the location of the pilocytic astrocytoma. RESULTS: This review provides an overview of the different imaging findings regarding pilocytic astrocytomas using both conventional and advanced magnetic resonance imaging sequences according to tumour location; the findings are strongly related to the tumour's tendency to infiltrate surrounding structures, being able to carry out gross total resection, and finally the prognosis. CONCLUSIONS: Knowledge of these imaging manifestations of pilocytic astrocytoma may be helpful to arrive at an accurate diagnosis. TEACHING POINTS: • To recognise the various imaging findings of pilocytic astrocytoma on both conventional and advanced magnetic resonance imaging sequences. • To identify the characteristic imaging findings according to tumour location. • To discuss the relevant differential diagnoses of pilocytic astrocytoma in each tumour location.

15.
Hellenic J Cardiol ; 54(5): 408-12, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24100187

RESUMEN

Left atrial appendage (LAA) occlusion has been introduced into clinical practice as a valuable alternative to oral anticoagulation for stroke prevention in patients with non-valvular atrial fibrillation. In this case presentation we describe the first LAA occlusion in Greece using the Amplatzer Amulet device. We also briefly discuss issues related to procedural safety and multimodality imaging for LAA occlusion.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Anciano , Fibrilación Atrial/complicaciones , Grecia , Humanos , Masculino , Accidente Cerebrovascular/cirugía , Resultado del Tratamiento
16.
BMJ Case Rep ; 20132013 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-24051144

RESUMEN

Brain irradiation has several well-known long-term side effects, including radiation-induced neoplasms and vasculopathy. In this case report, we describe an extremely rare case of meningioma and 15 cavernomas developing in a 29-year-old man, 19 years after cranial irradiation for posterior cranial fossa medulloblastoma. To our knowledge, this is the first case of a radiation-induced meningioma accompanied by this many radiation-induced cavernous angiomas.


Asunto(s)
Neoplasias Cerebelosas/radioterapia , Hemangioma Cavernoso del Sistema Nervioso Central/etiología , Meduloblastoma/radioterapia , Neoplasias Meníngeas/etiología , Meningioma/etiología , Neoplasias Inducidas por Radiación/diagnóstico , Adulto , Neoplasias Cerebelosas/cirugía , Diagnóstico Diferencial , Estudios de Seguimiento , Hemangioma Cavernoso del Sistema Nervioso Central/diagnóstico , Hemangioma Cavernoso del Sistema Nervioso Central/cirugía , Humanos , Imagen por Resonancia Magnética , Masculino , Meduloblastoma/cirugía , Neoplasias Meníngeas/diagnóstico , Neoplasias Meníngeas/cirugía , Meningioma/diagnóstico , Meningioma/cirugía , Neoplasias Inducidas por Radiación/cirugía , Procedimientos Neuroquirúrgicos
17.
Insights Imaging ; 4(2): 157-62, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23397520

RESUMEN

OBJECTIVE: To evaluate the diagnostic performance of magnetic resonance (MR) arthrography of the shoulder in the diagnosis of anteroinferior labrum lesions, using arthroscopy as the reference standard and to classify these lesions. METHODS: Institutional review board approval was obtained. The study population included 59 consecutive patients with history and clinical diagnosis of acute or chronic anterior shoulder instability. A total of 62 MR arthrograms were performed, since three patients had undergone a bilateral procedure. Arthroscopy, which was performed within a mean of 3 months (range 2-5 months) after MR arthrography, was used as the reference standard. Sensitivity, specificity, accuracy, positive and negative predictive values were then calculated. RESULTS: MR arthrography showed a sensitivity of 96 % and a specificity of 80 % for the overall detection of anteroinferior labrum abnormalities. The diagnostic accuracy was 95 % and the positive and negative predictive values were 98 % and 66 % respectively. Ten lesions were non-classifiable on surgery, of which eight were non classifiable on MR arthrography also. CONCLUSIONS: MR arthrography is highly accurate for the detection and classification of shoulder anteroinferior labrum lesions. Shoulder surgeons can confidently rely on this method to determine which patients will benefit from arthroscopy. MAIN MESSAGES: • MR arthrography is accurate for the detection and classification of shoulder labrum lesions. • MR arthrography is a valuable tool for the preoperative planning in acute or chronic instability. • Shoulder surgeons can rely on this method to determine which patients will benefit from arthroscopy.

20.
J Neurol Surg A Cent Eur Neurosurg ; 73(4): 199-203, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22585563

RESUMEN

The authors report the results of a retrospective study about computed tomography (CT)-guided percutaneous vertebral biopsies in 79 cases (44 males and 35 females, aged from 6 to 84 years old). Five biopsies were performed at the cervical level, 31 at the thoracic, 30 at the lumbar, and 13 at the sacrum. A diagnosis was obtained in 75 out of the 79 patients. Diagnostic yield was 95%, and diagnostic accuracy was 97.3%. Core needle biopsy under CT guidance for spinal lesions is a fast, relatively simple, minimally invasive, and low-cost method, with high levels of diagnostic accuracy and few complications. It plays a major role in the correct diagnosis and therapeutic planning. CT guidance allows safe and accurate biopsy of osseous lesions throughout the spine, obviating invasive open biopsy in most cases.


Asunto(s)
Biopsia con Aguja Gruesa/métodos , Enfermedades de la Columna Vertebral/patología , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Contraindicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Traumatismos de la Médula Espinal/diagnóstico , Traumatismos de la Médula Espinal/patología , Traumatismos de la Médula Espinal/cirugía , Enfermedades de la Columna Vertebral/diagnóstico , Neoplasias de la Columna Vertebral/patología , Neoplasias de la Columna Vertebral/secundario , Neoplasias de la Columna Vertebral/cirugía , Columna Vertebral/patología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA