Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Anal Biochem ; 523: 17-23, 2017 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-28137603

RESUMEN

In this paper, we developed a fluorescent aptasensor for 17ß-estradiol (E2) determination in aqueous solution using label-free E2-specific aptamer, gold nanoparticles (AuNPs) and Rhodamine B (RhoB) as sensing probe, fluorescent quencher and fluorescent indicator respectively. In the absence of E2, AuNPs were wrapped by E2 aptamer and maintained dispersed in NaCl solution basically. These dispersed AuNPs could effectively impair the originally high fluorescence of RhoB. Contrarily, in the presence of E2, E2 aptamer could specifically combine with E2 to form E2-aptamer complex, so the AuNPs were released by E2 aptamer and aggregated under the influence of NaCl. The aggregated AuNPs have a weak influence on RhoB fluorescence. Therefore, the E2 concentration can be determined by the change of fluorescence intensity of RhoB. This fluorescent assay has a detection limit as low as 0.48 nM, a linear range from 0.48 to 200 nM, and high selectivity over other disrupting chemicals. It was applied to determine E2 in water samples with recoveries in the range of 94.3-111.7%. The fluorescent aptasensor holds great potential for E2 detection in environmental water samples.


Asunto(s)
Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Estradiol/análisis , Fluorescencia , Oro/química , Nanopartículas del Metal/química , Rodaminas/química , Colorantes Fluorescentes/química , Humanos , Límite de Detección
2.
Anal Biochem ; 514: 2-7, 2016 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-27615801

RESUMEN

This paper proposes an aptasensor for progesterone (P4) detection in human serum and urine based on the aggregating behavior of gold nanoparticles (AuNPs) controlled by the interactions among P4-binding aptamer, target P4 and cationic surfactant hexadecyltrimethylammonium bromide (CTAB). The aptamer can form an aptamer-P4 complex with P4, leaving CTAB free to aggregate AuNPs in this aptasensor. Thus, the sensing solution will turn from red (520 nm) to blue (650 nm) in the presence of P4 because P4 aptamers are used up firstly owing to the formation of an aptamer-P4 complex, leaving CTAB free to aggregate AuNPs. However, in the absence of P4, CTAB combines with aptamers so that AuNPs still remain dispersed. Therefore, this assay makes it possible to detect P4 not only by absorbance measurement but also through naked eyes. By monitoring the variation of absorbance and color, a CTAB-induced colorimetric assay for P4 detection was established with a detection limit of 0.89 nM. Besides, the absorbance ratio A650/A520 has a linear correlation with the P4 concentration of 0.89-500 nM. Due to the excellent recoveries in serum and urine, this biosensor has great potential with respect to the visual and instrumental detection of P4 in biological fluids.


Asunto(s)
Técnicas Biosensibles/instrumentación , Colorimetría/métodos , Progesterona/sangre , Progesterona/orina , Aptámeros de Nucleótidos , Técnicas Biosensibles/métodos , Cetrimonio , Compuestos de Cetrimonio/química , Colorimetría/instrumentación , Oro/química , Humanos , Nanopartículas del Metal/química , Sensibilidad y Especificidad , Tensoactivos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...