Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Interv Card Electrophysiol ; 65(3): 643-649, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35804256

RESUMEN

BACKGROUND: Although fluoroless transseptal puncture (TSP) guided by intracardiac echocardiography (ICE) has been used for many years, there are no reports of an accurate site-specific method for TSP in detail, especially about the safety and efficiency of the method. This study aimed to compare the efficacy and safety of TSP guided by three-dimensional ICE using a fluoroless site-specific method with that of the conventional fluoroless method in patients with atrial fibrillation (AF). METHODS: This prospective study included 60 patients with AF scheduled for radiofrequency ablation who were assigned to undergo modified fluoroless site-specific TSP (SS-ICE group, n = 30) or conventional fluoroless TSP (C-ICE group, n = 30). TSP was guided by three-dimensional ICE in both study groups. RESULTS: All fluoroless TSP were performed successfully in both groups. There were no significant differences in patient characteristics, Pre-TSP time (11.3 ± 1.7 min vs. 11.1 ± 1.6 min, P = 0.822) and TSP time (3.4 ± 0.9 min vs. 3.5 ± 1.1 min, P = 0.772) between the SS-ICE group and the C-ICE group. The distance between the actual traversing point and the presetting point in the fossa ovalis was less than 5 mm in 87% of patients (26/30, 3.1 ± 1.2 mm) in the SS-ICE group. There were no TSP-related complications in either group. CONCLUSION: SS-ICE method is a simple, safe, and effective approach for fluoroless site-specific TSP.


Asunto(s)
Ecocardiografía , Humanos , Estudios Prospectivos
2.
Biochem Biophys Res Commun ; 517(1): 8-14, 2019 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-31307785

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is the most common progressive cardiac arrhythmia and is often associated with rapid contraction in both atria and ventricles. The role of atrial energy and metabolic homeostasis in AF progression is under-investigated. OBJECTIVES: To determine the remodeling of energy metabolism during persistent AF and the effect of eplerenone (EPL), an aldosterone inhibitor, on metabolic homeostasis. METHODS: A nonsustained atrial pacing sheep model was developed to simulate the progression of AF from paroxysmal to persistent. Metabolomic and proteomic analyses at termination of the experiment were used to analyze atrial tissues obtained from sheep in sham, sugar pill (SP) and EPL-treated groups. RESULTS: Proteomic analysis indicated that compared to the sham group, in SP group, fatty acid (FA) synthesis, FA oxidation, tricarboxylic acid (TCA) cycle processes and amino acids (AAs) transport and metabolism were reduced, while glycolytic processes were increased. In metabolomic analysis, the levels of intermediate metabolites of the glycolytic pathways, including 2-phosphoglyceric acid (2 PG), 1,3-bisphosphoglyceric acid (1,3 PG), and pyruvate, HBP (uridine diphosphate-N-acetylglucosamine, UDP-GlcNAc), TCA (citrate) and AAs were greater while the levels of the majority of lipid classes, including phosphatidic acid (PA), phosphatidylcholine (PC), phosphatidylglycerol (PG), glycerophosphoglycerophosphates (PGP), glycerophosphoinositols (PI) and glycerophosphoserines (PS), were decreased in the atria of SP group than in those of sham group. EPL-pretreatment decreased the expression of glut4 and increased the content of acylcarnitines and lipids, such as lyso phospholipids, phospholipids and neutral lipids. CONCLUSION: In the metabolic remodeling during AF, glucose and lipid metabolism were up- and down-regulated, respectively, to sustain TCA cycle anaplerosis. EPL partialy reversed the metabolic shifting.


Asunto(s)
Fibrilación Atrial/metabolismo , Metabolismo Energético , Miocardio/metabolismo , Animales , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/patología , Ciclo del Ácido Cítrico/efectos de los fármacos , Modelos Animales de Enfermedad , Metabolismo Energético/efectos de los fármacos , Eplerenona/uso terapéutico , Glucosa/metabolismo , Homeostasis/efectos de los fármacos , Metabolismo de los Lípidos/efectos de los fármacos , Masculino , Redes y Vías Metabólicas/efectos de los fármacos , Antagonistas de Receptores de Mineralocorticoides/uso terapéutico , Miocardio/patología , Ovinos
3.
J Huazhong Univ Sci Technolog Med Sci ; 33(5): 650-655, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24142715

RESUMEN

As new-type powered sheaths are expensive and unavailable, the standard lead extraction techniques remain the mainstay in clinical applications in many countries. The purpose of this study was to re-evaluate the clinical application of the standard lead extraction techniques and equipment, and make some procedural modifications and innovations. In our center, between January 2006 and May 2012, 229 patients (median, 66 years) who underwent lead extraction due to infection and lead malfunction were registered and followed up prospectively with respect to clinical features, reasons for lead extraction, technical characteristics, and clinical prognosis. A total of 440 leads had to be extracted transvenously by using special tools from 229 patients (male, 72.1%). Vegetations ≥1 cm were detected in six patients. Locking Stylets were applied for 398 (90.5%) leads. Telescoping dilator polypropylene sheaths and counter traction technique were used for 202 (45.9%) leads due to lead adhesion, and the mean implant duration of the 202 leads was longer than the other 238 leads (48.9±22.6 vs. 26.6±17.8 months; P <0.01). In addition, modified isolation and snare techniques were used for 56 leads (12.7%). Minor and major procedure-related complications occurred in three (1.3%) and four (1.7%) cases respectively, including one death (0.4%). Severe lead residue occurred in one case. Complete procedural success rate was 96.1% (423/440), and clinical success rate was 98.9% (435/440). The median follow-up period was 18 (1-76) months. No infection- and procedure-related death occurred in our series. Our data demonstrated that high clinical success rate of transvenous lead extraction can be guaranteed by making full use of the standard lead extraction techniques and equipment with individualized modifications.


Asunto(s)
Remoción de Dispositivos/métodos , Marcapaso Artificial , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antibacterianos/uso terapéutico , Niño , Preescolar , Electrodos Implantados , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/cirugía , Resultado del Tratamiento , Adulto Joven
4.
J Geriatr Cardiol ; 10(1): 3-9, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23610567

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillator (ICD) leads might not be extracted especially in developing countries because of the high cost and lack of specialized tools. We aimed to evaluate transvenous extraction of ICD leads using optimized standard techniques. METHODS: We prospectively analyzed clinical characteristics, optimized extraction techniques and the feasibility of extraction for 40 patients (33 males; mean age 47.9 ± 16.1 years) with 42 ICD leads. RESULTS: Complete procedural success rate was 95.2% (40/42), and the clinical success rate was 97.6% (41/42). One ICD lead required cardiothoracic surgery. Minor complications occurred in three cases (7.5%), and no major complications or death occurred. Locking stylets were used to extract most leads (34, 81.0%) and almost half of the leads (20, 47.6%) required mechanical dilatation to free fibrotic adhesions; these leads had been implanted for a longer period of time than the others (43.7 ± 18.2 vs. 18.4 ± 13.4 months, P < 0.05). Three-quarters of the leads (30, 71.4%) were extracted with locking stylets plus manual traction (12, 28.6%), or mechanical dilatation with counter-traction (18, 42.8%) by the superior vena cava approach and one-quarter of the leads (11, 26.2%) were removed by optimized snare techniques using the femoral vein approach. Median extraction time was 20 min (range 2-68 min) per lead. Linear regression analysis showed that the extraction time was significantly correlated with implant duration (r = 0.70, P < 0.001). Median follow-up was 14.5 months (range 1-58 months), no infection, or procedure-related death occurred in our series. CONCLUSIONS: Our optimized procedure for transvenous extraction of ICD leads provides a practical and low-cost method for standard procedures.

5.
Chin Med J (Engl) ; 125(20): 3707-11, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23075729

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) device and coronary sinus (CS) lead extraction are required due to the occurrence of systemic infection, malfunction, or upgrade. Relevant research of CS lead extraction is rare, especially in developing countries because of the high cost and lack of specialized tools. We aimed to evaluate percutaneous extraction of CS leads by modified conventional techniques. METHODS: Of 200 patients referred for lead extraction from January 2007 to June 2011, 24 (12.0%) involved CS leads (24 CS leads). We prospectively analyzed clinical characteristics, optimized extraction techniques and feasibility of extraction. RESULTS: Complete procedural success was achieved in 23 patients (95.8%), and the clinical success in 24 patients (100.0%). The leading indication for CS lead extraction was infection (66.7%). Mean implant duration was (29.5 ± 20.2) months (range, 3 - 78 months). Sixteen CS leads (66.6%) were removed with locking stylets plus manual traction by superior transvenous approach. Mechanical dilatation and counter-traction was required to free fibrotic adhesions and extract 4 CS leads (16.7%), which had longer implant duration than other leads ((62.5 ± 12.3) vs. (22.9 ± 14.1) months, P < 0.05). Another 4 CS (16.7%) leads were removed by modified and innovative snare techniques from femoral vein approach. Median extraction time was 11 minutes (range, 3 - 61 minutes) per CS lead, which had significant correlation with implant duration (r = 0.8, P < 0.001). Sixteen patients (66.6%) were reimplanted with new devices at a median of 7.5 days after extraction. Median followed-up was 23.5 months (range, 8 - 61 months), three patients died due to sudden cardiac death (26 months), heart failure (45 and 57 months, respectively). CONCLUSION: The modified procedure was proved to be practical for percutaneous extraction of CS leads, especially in developing countries lacking expensive powered sheaths.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Seno Coronario/cirugía , Remoción de Dispositivos/métodos , Electrodos Implantados/efectos adversos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...