Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Zhongguo Xue Xi Chong Bing Fang Zhi Za Zhi ; 34(4): 396-399, 2021 Dec 23.
Artículo en Chino | MEDLINE | ID: mdl-36116930

RESUMEN

OBJECTIVE: To evaluate the molluscicidal effect of 50% wettable powder of niclosamide ethanolamine salt (WPNES) against Oncomelania hupensis on the soil surface and inside the soil layer by immersion method in winter. METHODS: O. hupensis snails were placed on the soil surface and 2, 5 cm and 10 cm under the soil layer outdoors in winter, and then immersed in 50% WPNES at concentrations of 1 mg/L and 2 mg/L for 1, 3 d and 7 d, while dechlorinated water served as controls. Snail mortality was observed following immersion with 50% WPNES on the soil surface and inside the soil layer. RESULTS: Following immersion with 50% WPNES at concentrations of 2 mg/L and 1 mg/L outdoors in winter, the 3-day corrected snail mortality rates were 98.0% and 76.0% on the soil surface, and the 7-day corrected snail mortality rate was both 100.0%. Following immersion with 50% WPNES at concentrations of 2 mg/L and 1 mg/L outdoors in winter, the 7-day corrected snail mortality rates were 95.5% and 85.6% 2 cm below the soil layer, 66.0% and 6.4% 5 cm below the soil layer. However, the 7-day snail mortality rate swere comparable between the 50% WPNES treatment group (at 2 mg/L and 1 mg/L) and controls 10 cm below the soil layer (both P > 0.05). CONCLUSIONS: Immersion of 50% WPNES at a concentration of 2 mg/L for 7 days presents a high molluscicidal efficacy against O. hupensis on the soil surface and 5 cm within the soil layers in winter.


Asunto(s)
Moluscocidas , Niclosamida , Animales , Etanolamina/farmacología , Etanolaminas/farmacología , Inmersión , Moluscocidas/farmacología , Niclosamida/farmacología , Polvos/farmacología , Caracoles , Suelo , Agua
2.
Rev Sci Instrum ; 87(11): 11D434, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910562

RESUMEN

The foil resistive bolometer diagnostic on experimental advanced superconducting tokamak has been upgraded partly with a new generation of detectors. The new detectors have faster response time. However, the microwave interference is still a serious issue for the bolometer system. The system response to microwave is tested, and the test results show that the closed Wheatstone bridge circuit in the detector is the most sensitive component to high power microwave field. Simulation results of microwave transmission by the high frequency structure simulator software and shielding design are also presented.

3.
Rev Sci Instrum ; 87(11): 11D616, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910316

RESUMEN

Volume recombination plays an important role towards plasma detachment for magnetically confined fusion devices. High quantum number states of the Balmer series of deuterium are used to study recombination. On EAST (Experimental Advanced Superconducting Tokamak), two visible spectroscopic measurements are applied for the upper/lower divertor with 13 channels, respectively. Both systems are coupled with Princeton Instruments ProEM EMCCD 1024B camera: one is equipped on an Acton SP2750 spectrometer, which has a high spectral resolution ∼0.0049 nm with 2400 gr/mm grating to measure the Dα(Hα) spectral line and with 1200 gr/mm grating to measure deuterium molecular Fulcher band emissions and another is equipped on IsoPlane SCT320 using 600 gr/mm to measure high-n Balmer series emission lines, allowing us to study volume recombination on EAST and to obtain the related line averaged plasma parameters (Te, ne) during EAST detached phases. This paper will present the details of the measurements and the characteristics of deuterium Balmer series line emissions during density ramp-up L-mode USN plasma on EAST.

5.
Phys Rev Lett ; 114(5): 055001, 2015 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-25699449

RESUMEN

A critical challenge facing the basic long-pulse high-confinement operation scenario (H mode) for ITER is to control a magnetohydrodynamic (MHD) instability, known as the edge localized mode (ELM), which leads to cyclical high peak heat and particle fluxes at the plasma facing components. A breakthrough is made in the Experimental Advanced Superconducting Tokamak in achieving a new steady-state H mode without the presence of ELMs for a duration exceeding hundreds of energy confinement times, by using a novel technique of continuous real-time injection of a lithium (Li) aerosol into the edge plasma. The steady-state ELM-free H mode is accompanied by a strong edge coherent MHD mode (ECM) at a frequency of 35-40 kHz with a poloidal wavelength of 10.2 cm in the ion diamagnetic drift direction, providing continuous heat and particle exhaust, thus preventing the transient heat deposition on plasma facing components and impurity accumulation in the confined plasma. It is truly remarkable that Li injection appears to promote the growth of the ECM, owing to the increase in Li concentration and hence collisionality at the edge, as predicted by GYRO simulations. This new steady-state ELM-free H-mode regime, enabled by real-time Li injection, may open a new avenue for next-step fusion development.

6.
Rev Sci Instrum ; 86(12): 123512, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26724032

RESUMEN

A multi-energy soft x-ray (ME-SXR) diagnostic has been built for electron temperature profile in the edge plasma region in Experimental Advanced Superconducting Tokamak (EAST) after two rounds of campaigns. Originally, five preamplifiers were mounted inside the EAST vacuum vessel chamber attached to five vertically stacked compact diode arrays. A custom mechanical structure was designed to protect the detectors and electronics under constraints of the tangential field of view for plasma edge and the allocation of space. In the next experiment, the mechanical structure was redesigned with a barrel structure to absolutely isolate it from the vacuum vessel. Multiple shielding structures were mounted at the pinhole head to protect the metal foils from lithium coating. The pre-amplifiers were moved to the outside of the vacuum chamber to avoid introducing interference. Twisted copper cooling tube was embedded into the back-shell near the diode to limit the temperature of the preamplifiers and diode arrays during vacuum vessel baking when the temperature reached 150 °C. Electron temperature profiles were reconstructed from ME-SXR measurements using neural networks.

7.
Rev Sci Instrum ; 83(9): 093501, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23025621

RESUMEN

The resistive bolometer system has been successfully employed on experimental advanced superconducting tokamak for the first time to measure the radiated power of plasma. The bolometer detectors are based on 4 µm thick Pt absorbers deposited on 1.5 µm thick SiN membranes. The system consists of 3 cameras with a total of 48 channels. The detector and the system setup are described in detail. The detector calibration and typical measurement results are presented as well.

8.
Rev Sci Instrum ; 81(6): 063501, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20590235

RESUMEN

An assembly of soft x-ray pulse height analyzer system, based on silicon drift detector (SDD), has been successfully established on the experimental advanced superconducting tokamak (EAST) to measure the spectrum of soft x-ray emission (E=1-20 keV). The system, including one 15-channel SDD linear array, is installed on EAST horizontal port C. The time-resolved radial profiles of electron temperature and K(alpha) intensities of metallic impurities have been obtained with a spatial resolution of around 7 cm during a single discharge. It was found that the electron temperatures derived from the system are in good agreement with the values from Thomson scattering measurements. The system can also be applied to the measurement of the long pulse discharge for EAST. The diagnostic system is introduced and some typical experimental results obtained from the system are also presented.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...