1.
Forensic Sci Int ; 361: 112153, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39029141

RESUMEN

This study aimed to identify if biological material could be detected on the opposite side to deposition on fabric by commonly used presumptive and/or secondary tests. Additionally, this study aimed to ascertain if there is a difference in the DNA quantity and quality from samples obtained from both sides of the same substrate: cotton, polyester, denim, or combined viscose and polyester swatches. Blood, semen, or saliva (25 µL) was deposited on one side of 5 replicates of each fabric type and left for 24 h. Blood swatches were tested using Hemastix® and the ABACard® HemaTrace® immunoassay, semen swatches were tested using acid phosphatase (AP) reagent, the ABACard® p30® immunoassay and hematoxylin and eosin staining, and saliva swatches were tested using Phadebas® paper and the RSID-Saliva™ immunoassay. Both sides of each swatch were separately wet/dry swabbed and subjected to DNA analysis. Blood was able to be detected on the underside of all fabrics using both tests. Semen was able to be detected on the underside of swatches using the presumptive AP test but not p30®, and sperm was rarely observed. Saliva was able to be detected by RSID-Saliva™ but not Phadebas® paper when the underside of swatches were tested. Across all biological materials, DNA was able to be recovered from the top side of all 60 swatches. For the underside, DNA was able to be recovered from 54 swatches. Of the 6 swatches that DNA was unable to be recovered from, one sample was from semen and the rest were from saliva. This study has demonstrated that DNA and components of interest in forensically relevant biological material can be recovered from the opposite side to where it was originally deposited, and that observing biological material and/or DNA on one side of fabric does not definitively indicate direct deposition on that side.


Asunto(s)
Dermatoglifia del ADN , ADN , Saliva , Semen , Textiles , Saliva/química , Semen/química , Humanos , Masculino , Proyectos Piloto , ADN/análisis , Inmunoensayo , Sangre , Manchas de Sangre , Fosfatasa Ácida/análisis , Vestuario
2.
Forensic Sci Int ; 361: 112085, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38850619

RESUMEN

Previous studies have shown that environmental DNA (eDNA) from human sources can be recovered from natural bodies of water, and the generation of DNA profiles from such environmental samples may assist in forensic investigations. However, fundamental knowledge gaps exist around the factors influencing the probability of detecting human eDNA and the design of optimal sampling protocols. One of these is understanding the particle sizes eDNA signals are most strongly associated with and the most appropriate filter size needed for efficiently capturing eDNA particles. This study assessed the amount of mitochondrial eDNA associated with different particle sizes from human blood and skin cells recovered from freshwater samples. Samples (300 mL) were taken from experimental 10 L tanks of freshwater spiked with 50 µL of human blood or skin cells deposited by vigorously rubbing hands together for two minutes in freshwater. Subsamples were collected by passing 250 mL of experimental water sample through six different filter pore sizes (from 0.1 to 8 µm). This process was repeated at four time intervals after spiking over 72 hours to assess if the particle size of the amount of eDNA recovered changes as the eDNA degrades. Using a human-specific quantitative polymerase chain reaction (qPCR) assay targeting the HV1 mitochondrial gene region, the total amount of mitochondrial eDNA associated with different particle size fractions was determined. In the case of human blood, at 0 h, the 0.45 µm filter pore size captured the greatest amount of mitochondrial eDNA, capturing 42 % of the eDNA detected. The pattern then changed after 48 h, with the 5 µm filter pore size capturing the greatest amount of eDNA (67 %), and 81 % of eDNA at 72 h. Notably, a ten-fold dilution proved to be a valuable strategy for enhancing eDNA recovery from the 8 µm filter at all time points, primarily due to the PCR inhibition observed in hemoglobin. For human skin cells, the greatest amounts of eDNA were recovered from the 8 µm filter pore size and were consistent through time (capturing 37 %, 56 %, and 88 % of eDNA at 0 hours, 48 hours, and 72 hours respectively). There is a clear variation in the amount of eDNA recovered between different cell types, and in some forensic scenarios, there is likely to be a mix of cell types present. These results suggest it would be best to use a 5 µm filter pore size to capture human blood and an 8 µm filter pore size to capture human skin cells to maximize DNA recovery from freshwater samples. Depending on the cell type contributing to the eDNA, a combination of different filter pore sizes may be employed to optimize the recovery of human DNA from water samples. This study provides the groundwork for optimizing a strategy for the efficient recovery of human eDNA from aquatic environments, paving the way for its broader application in forensic and environmental sciences.


Asunto(s)
ADN Ambiental , ADN Mitocondrial , Agua Dulce , Tamaño de la Partícula , Humanos , Piel/química , Manejo de Especímenes/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa , Dermatoglifia del ADN/métodos , Filtración
3.
Forensic Sci Int ; 360: 112046, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38718526

RESUMEN

Research into the recovery of DNA from illicit drug samples has shown it is possible to get forensically useful profiles from such substrates. However, it is not yet known if the different physical states that drugs can be found in influences the quantity and quality of DNA that can be recovered or what is the best sampling method to adopt for powdered samples. This research used acetaminophen in four different states - large crystalline, powder, in solution, or residue - to determine the efficacy of current DNA technology in recovery and analysis of the resulting sample. Five replicates of each were prepared. Human blood was deposited on or mixed with the drug and left for 1 hour. The surface of the drug was sampled by wet/dry swabbing (where appropriate), or the entire sample was deposited in a tube, and the DNA then extracted using DNA-IQ™. The amount of DNA recovered (ng), degradation index, number of PCR cycles (Ct) required for the IPC to reach threshold, number of alleles in the DNA profile and average peak height (APH) were assessed. All samples, irrespective of the physical state they were collected from, returned full DNA profiles that corresponded to the DNA profile of the blood donor, with no degradation or inhibition detected. It was also found the wet/dry swabbing method returned higher levels of DNA than inclusion of the entire sample into the tube for powdered acetaminophen and the appropriate method to use will be dependent on casework circumstances. The findings of this research further develops our understanding of the recovery of DNA from drugs, and supports the need for further investigation to understand under what conditions DNA can be recovered from illicit substances.


Asunto(s)
Acetaminofén , Dermatoglifia del ADN , ADN , Reacción en Cadena de la Polimerasa , Manejo de Especímenes , Acetaminofén/sangre , Humanos , ADN/aislamiento & purificación , Manejo de Especímenes/métodos , Dermatoglifia del ADN/métodos , Polvos , Repeticiones de Microsatélite , Analgésicos no Narcóticos , Degradación Necrótica del ADN
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA