Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 10 de 10
1.
Biosens Bioelectron ; 260: 116446, 2024 Sep 15.
Article En | MEDLINE | ID: mdl-38820722

Understanding brain function is essential for advancing our comprehension of human cognition, behavior, and neurological disorders. Magnetic resonance imaging (MRI) stands out as a powerful tool for exploring brain function, providing detailed insights into its structure and physiology. Combining MRI technology with electrophysiological recording system can enhance the comprehension of brain functionality through synergistic effects. However, the integration of neural implants with MRI technology presents challenges because of its strong electromagnetic (EM) energy during MRI scans. Therefore, MRI-compatible neural implants should facilitate detailed investigation of neural activities and brain functions in real-time in high resolution, without compromising patient safety and imaging quality. Here, we introduce the fully MRI-compatible monolayer open-mesh pristine PEDOT:PSS neural interface. This approach addresses the challenges encountered while using traditional metal-based electrodes in the MRI environment such as induced heat or imaging artifacts. PEDOT:PSS has a diamagnetic property with low electrical conductivity and negative magnetic susceptibility similar to human tissues. Furthermore, by adopting the optimized open-mesh structure, the induced currents generated by EM energy are significantly diminished, leading to optimized MRI compatibility. Through simulations and experiments, our PEDOT:PSS-based open-mesh electrodes showed improved performance in reducing heat generation and eliminating imaging artifacts in an MRI environment. The electrophysiological recording capability was also validated by measuring the local field potential (LFP) from the somatosensory cortex with an in vivo experiment. The development of neural implants with maximized MRI compatibility indicates the possibility of potential tools for future neural diagnostics.


Brain , Magnetic Resonance Imaging , Polymers , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Brain/physiology , Humans , Animals , Polymers/chemistry , Biosensing Techniques/methods , Polystyrenes/chemistry , Electrodes, Implanted , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Thiophenes/chemistry , Equipment Design , Electric Conductivity
2.
Adv Sci (Weinh) ; 11(15): e2303403, 2024 Apr.
Article En | MEDLINE | ID: mdl-38348559

Communication with hand gestures plays a significant role in human-computer interaction by providing an intuitive and natural way for humans to communicate with machines. Ultrasound-based devices have shown promising results in contactless hand gesture recognition without requiring physical contact. However, it is challenging to fabricate a densely packed wearable ultrasound array. Here, a stretchable ultrasound array is demonstrated with closely packed transducer elements fabricated using surface charge engineering between pre-charged 1-3 Lead Zirconate Titanate (PZT) composite and thin polyimide film without using a microscope. The array exhibits excellent ultrasound properties with a wide bandwidth (≈57.1%) and high electromechanical coefficient (≈0.75). The ultrasound array can decipher gestures up to 10 cm in distance by using a contactless triboelectric module and identify materials from the time constant of the exponentially decaying impedance based on their triboelectric properties by utilizing the electrostatic induction phase. The newly proposed metric of the areal-time constant is material-specific and decreases monotonically from a highly positive human body (1.13 m2 s) to negatively charged polydimethylsiloxane (PDMS) (0.02 m2 s) in the triboelectric series. The capability of the closely packed ultrasound array to detect material along with hand gesture interpretation provides an additional dimension in the next-generation human-robot interaction.


Engineering , Gestures , Humans , Ultrasonography , Electric Impedance
3.
Chem Eng J ; 4652023 Jun 01.
Article En | MEDLINE | ID: mdl-37484163

Wearable electronics with applications in healthcare, human-machine interfaces, and robotics often explore complex manufacturing procedures and are not disposable. Although the use of conductive pencil patterns on cellulose paper provides inexpensive, disposable sensors, they have limited stretchability and are easily affected by variations in the ambient environment. This work presents the combination of pencil-on-paper with the hydrophobic fumed SiO2 (Hf-SiO2) coating and stretchable kirigami structures from laser cutting to prepare a superhydrophobic, stretchable pencil-on-paper multifunctional sensing platform. The resulting sensor exhibits a large response to NO2 gas at elevated temperature from self-heating, which is minimally affected by the variations in the ambient temperature and relative humidity, as well as mechanical deformations such as bending and stretching states. The integrated temperature sensor and electrodes with the sensing platform can accurately detect temperature and electrophysiological signals to alert for adverse thermal effects and cardiopulmonary diseases. The thermal therapy and electrical stimulation provided by the platform can also deliver effective means to battle against inflammation/infection and treat chronic wounds. The superhydrophobic pencil-onpaper multifunctional device platform provides a low-cost, disposable solution to disease diagnostic confirmation and early treatment for personal and population health.

5.
Nat Commun ; 14(1): 2907, 2023 Jun 01.
Article En | MEDLINE | ID: mdl-37264026

Despite the extensive developments of flexible capacitive pressure sensors, it is still elusive to simultaneously achieve excellent linearity over a broad pressure range, high sensitivity, and ultrahigh pressure resolution under large pressure preloads. Here, we present a programmable fabrication method for microstructures to integrate an ultrathin ionic layer. The resulting optimized sensor exhibits a sensitivity of 33.7 kPa-1 over a linear range of 1700 kPa, a detection limit of 0.36 Pa, and a pressure resolution of 0.00725% under the pressure of 2000 kPa. Taken together with rapid response/recovery and excellent repeatability, the sensor is applied to subtle pulse detection, interactive robotic hand, and ultrahigh-resolution smart weight scale/chair. The proposed fabrication approaches and design toolkit from this work can also be leveraged to easily tune the pressure sensor performance for varying target applications and open up opportunities to create other iontronic sensors.

6.
Small ; 19(39): e2302597, 2023 Sep.
Article En | MEDLINE | ID: mdl-37246255

Ultrathin crystalline silicon is widely used as an active material for high-performance, flexible, and stretchable electronics, from simple passive and active components to complex integrated circuits, due to its excellent electrical and mechanical properties. However, in contrast to conventional silicon wafer-based devices, ultrathin crystalline silicon-based electronics require an expensive and rather complicated fabrication process. Although silicon-on-insulator (SOI) wafers are commonly used to obtain a single layer of crystalline silicon, they are costly and difficult to process. Therefore, as an alternative to SOI wafers-based thin layers, here, a simple transfer method is proposed for printing ultrathin multiple crystalline silicon sheets with thicknesses between 300 nm to 13 µm and high areal density (>90%) from a single mother wafer. Theoretically, the silicon nano/micro membrane can be generated until the mother wafer is completely consumed. In addition, the electronic applications of silicon membranes are successfully demonstrated through the fabrication of a flexible solar cell and flexible NMOS transistor arrays.

7.
Nanoscale ; 15(9): 4236-4249, 2023 Mar 02.
Article En | MEDLINE | ID: mdl-36688506

Transient electronic devices have shown promising applications in hardware security and medical implants with diagnosing therapeutics capabilities since their inception. Control of the device transience allows the device to "dissolve at will" after its functional operation, leading to the development of on-demand transient electronics. This review discusses the recent developments and advantages of triggering strategies (e.g., electrical, thermal, ultrasound, and optical) for controlling the degradation of on-demand transient electronics. We also summarize bioresorbable sensors for medical diagnoses, including representative applications in electrophysiology and neurochemical sensing. Along with the profound advancements in medical diagnosis, the commencement of therapeutic systems such as electrical stimulation and drug delivery for the biomedical or medical implant community has also been discussed. However, implementing a transient electronic system in real healthcare infrastructure is still in its infancy. Many critical challenges still need to be addressed, including strategies to decouple multimodal sensing signals, dissolution selectivity in the presence of multiple stimuli, and a complete sensing-stimulation closed-loop system. Therefore, the review discusses future opportunities in transient decoupling sensors and robust transient devices, which are selective to a particular stimulus and act as hardware-based passwords. Recent advancements in closed-loop controller-enabled electronics have also been analyzed for future opportunities of using data-driven artificial intelligence-powered controllers in fully closed-loop transient systems.


Artificial Intelligence , Electronics , Prostheses and Implants , Electric Power Supplies , Drug Delivery Systems
8.
Adv Mater ; 35(14): e2210322, 2023 Apr.
Article En | MEDLINE | ID: mdl-36656071

Monitoring nitrogen utilization efficiency and soil temperature in agricultural systems for timely intervention is essential for crop health with reduced environmental pollution. Herein, this work presents a high-performance multi-parameter sensor based on vanadium oxide (VOX )-doped laser-induced graphene (LIG) foam to completely decouple nitrogen oxides (NOX ) and temperature. The highly porous 3D VOX -doped LIG foam composite is readily obtained by laser scribing vanadium sulfide (V5 S8 )-doped block copolymer and phenolic resin self-assembled films. The heterojunction formed at the LIG/VOX interface provides the sensor with enhanced response to NOX and an ultralow limit of detection of 3 ppb (theoretical estimate of 451 ppt) at room temperature. The sensor also exhibits a wide detection range, fast response/recovery, good selectivity, and stability over 16 days. Meanwhile, the sensor can accurately detect temperature over a wide linear range of 10-110 °C. The encapsulation of the sensor with a soft membrane further allows for temperature sensing without being affected by NOX . The unencapsulated sensor operated at elevated temperature removes the influences of relative humidity and temperature variations for accurate NOX measurements. The capability to decouple nitrogen loss and soil temperature paves the way for the development of future multimodal decoupled electronics for precision agriculture and health monitoring.

9.
Nano Lett ; 23(4): 1252-1260, 2023 02 22.
Article En | MEDLINE | ID: mdl-36584409

Although flexible humidity sensors are essential for human health monitoring, it is still challenging to achieve high sensitivity and easy disposal with simple, low-cost fabrication processes. This study presents the design and fabrication of highly reliable hand-drawn interdigital electrodes from pencil-on-paper treated with NaCl solution for highly sensitive hydration sensors working over a wide range of relative humidity (RH) levels from 5.6% to 90%. The applications of the resulting flexible humidity sensor go beyond the monitoring of respiratory rate and proximity to characterizations of human skin types and evaluations of skin barrier functions through insensible sweat measurements. The sensor array can also be integrated with a diaper to result in smart diapers to alert for an early diaper change. The design and fabrication strategies presented in this work could also be leveraged for the development of wearable, self-powered, and recyclable sensors and actuators in the future.


Wearable Electronic Devices , Humans , Sodium Chloride , Humidity , Skin , Sweat
10.
Adv Funct Mater ; 33(52)2023 Dec 22.
Article En | MEDLINE | ID: mdl-38525448

Although increasing efforts have been devoted to the development of non-invasive wearable or stretchable electrochemical sweat sensors for monitoring physiological and metabolic information, most of them still suffer from poor stability and specificity over time and fluctuating temperatures. This study reports the design and fabrication of a long-term stable and highly sensitive flexible electrochemical sensor based on nanocomposite-modified porous graphene by simple and facile laser treatment for detecting biomarkers such as glucose in sweat. The laser-reduced and patterned stable conductive nanocomposite on the porous graphene electrode provides the resulting glucose sensor with an excellent sensitivity of 1317.69 µAmM-1cm-2 with an ultra-low limit of detection (LOD) of 0.079 µM. The sensor can also detect pH and exhibit extraordinary stability to maintain more than 91% sensitivity over 21 days in ambient conditions. Taken together with a temperature sensor based on the same material system, the dual glucose and pH sensor integrated with a flexible microfluidic sweat sampling network further results in accurate continuous on-body glucose detection calibrated by the simultaneously measured pH and temperature. The low-cost, highly sensitive, and long-term stable platform could facilitate and pave the way for the early identification and continuous monitoring of different biomarkers for non-invasive disease diagnosis and treatment evaluation.

...